IEC 60384-4:1998/AMD1:2000
(Amendment)Amendment 1 - Fixed capacitors for use in electronic equipment - Part 4: Sectional specification: Aluminium electrolytic capacitors with solid and non-solid electrolyte
Amendment 1 - Fixed capacitors for use in electronic equipment - Part 4: Sectional specification: Aluminium electrolytic capacitors with solid and non-solid electrolyte
General Information
Relations
Buy Standard
Standards Content (Sample)
INTERNATIONAL IEC
STANDARD
60384-4
QC 300300
AMENDMENT 1
2000-03
Amendment 1
Fixed capacitors for use in electronic equipment –
Part 4:
Sectional specification:
Aluminium electrolytic capacitors with solid
and non-solid electrolyte
Amendement 1
Condensateurs fixes utilisés dans les
équipements électroniques –
Partie 4:
Spécification intermédiaire:
Condensateurs électrolytiques à l'aluminium à
électrolyte solide et non solide
IEC 2000 Copyright - all rights reserved
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
Commission Electrotechnique Internationale
PRICE CODE
C
International Electrotechnical Commission
For price, see current catalogue
– 2 – 60384-4 Amend. 1 © IEC:2000(E)
FOREWORD
This amendment has been prepared by IEC technical committee 40: Capacitors and resistors
for electronic equipment.
The text of this amendment is based on the following documents:
FDIS Report on voting
40/1122/FDIS 40/1168/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of the base publication and its amendments will
remain unchanged until 2003. At this date, the publication will be:
reconfirmed;
withdrawn;
replaced by a revised edition, or
amended.
––––––––––
Page 25
Table 2 – Test schedule for Qualification Approval
Replace, on page 35, under Group 4A, 4.14 Surge, in column “Conditions of test”, the existing
text:
Duration of charge: 30 s
Duration of discharge: 5 min 30 s
by
Duration of charge: 30 s
Duration of non-load: 5 min 30 s
Replace, on page 37, under Group 4B, 4.15 Reverse voltage, in column “Conditions of test”,
the existing text:
Duration: 125 h at upper category temperature with:
a) for solid electrolyte capacitors: a direct voltage of 0,15 U in reverse polarity direction or
c
b) for non-solid electrolyte capacitors: the voltage given in the detai
...
Questions, Comments and Discussion