IEC 60079-11:2023/ISH3:2024
(Main)Interpretation sheet 3 - Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
Interpretation sheet 3 - Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
Feuille d'interprétation 3 - Atmosphères explosives - Partie 11: Protection de l’appareil par sécurité intrinsèque "i"
General Information
- Status
- Published
- Publication Date
- 20-Aug-2024
- Technical Committee
- SC 31G - Intrinsically-safe apparatus
- Current Stage
- PPUB - Publication issued
- Start Date
- 21-Aug-2024
- Completion Date
- 20-Sep-2024
Relations
- Revised
IEC 60079-11:2023 - Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" - Effective Date
- 12-Apr-2024
Frequently Asked Questions
IEC 60079-11:2023/ISH3:2024 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Interpretation sheet 3 - Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"". This standard covers: Interpretation sheet 3 - Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
Interpretation sheet 3 - Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-11:2023/ISH3:2024 is classified under the following ICS (International Classification for Standards) categories: 29.260.20 - Electrical apparatus for explosive atmospheres. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 60079-11:2023/ISH3:2024 has the following relationships with other standards: It is inter standard links to IEC 60079-11:2023. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
You can purchase IEC 60079-11:2023/ISH3:2024 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of IEC standards.
Standards Content (Sample)
© IEC 2024
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
IEC 60079-11
Edition 7.0 2023-01
EXPLOSIVE ATMOSPHERES –
Part 11: Equipment protection by intrinsic safety “i”
INTERPRETATION SHEET 3
This interpretation sheet has been prepared by subcommittee 31G: Intrinsically-safe apparatus,
of IEC technical committee 31: Explosive atmospheres.
The text of this interpretation sheet is based on the following documents:
DISH Report on voting
31G/400/DISH 31G/403/RVDISH
Full information on the voting for the approval of this interpretation sheet can be found in the
report on voting indicated in the above table.
___________
IEC 60079-11 Edition 7.0 2023
EXPLOSIVE ATMOSPHERES – Part 11: Equipment protection by intrinsic safety “i”
Background
Devices which read from memory during operation are clearly programmable components and
need to be considered according to 7.7.8. IEC 60079-11 is not clear whether a component which
only reads from memory or internal registers during initialisation – such as a digital
potentiometer – is a programmable component according to 7.7.8 or a simpler semiconductor
which can be considered according to 7.7.2.
Question
Can a digital potentiometer (or other s
...










Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...