IEC 60335-2-23
(Fifth edition – 2003)
Household and similar electrical appliances – Safety –
Part 2-23: Particular requirements for appliances for skin or hair care
CORRIGENDUM 1
Pa
...
This May Also Interest You
IEC 60335-2-27:2024 is available as IEC 60335-2-27:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60335-2-27:2024 deals with the safety of electrical appliances incorporating emitters for exposing the skin to optical radiation (wavelength 100 nm to 1 mm), for household and similar use, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances including direct current (DC) supplied appliances and battery-operated appliances. As far as practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons using the appliances in tanning salons, beauty parlours and similar premises or at home. However, in general, it does not take into account
- persons (including children) whose physical, sensory or mental capabilities; or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction;
- children playing with the appliance.
Attention is drawn to the fact that
- for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary;
- in many countries, additional requirements are specified by the national health authorities, the national authorities responsible for the protection of labour and similar authorities.
This standard does not apply to
- appliances for skin or hair care (IEC 60335-2-23);
- sauna heating appliances and infrared cabins (IEC 60335-2-53);
- cosmetic and beauty care appliances incorporating lasers and intense light sources (IEC 60335-2-113);
- appliances for medical purposes (IEC 60601);
- appliances that use UV radiation for purposes other than tanning the skin;
- appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas).
This seventh edition cancels and replaces the sixth edition published in 2019. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment with IEC 60335-1:2020;
b) modification or conversion of some notes to normative text (Clause 1, 7.1);
c) clarification of product risk and liability (7.1);
d) modification of Annex DD as a normative annex, and modification of relevant text (7.12, Annex DD);
e) clarification of requirement for product use links provided (7.12.9);
f) clarification of the application of test probe 18 for appliances for use in tanning salons, beauty parlours and similar premises (8.1.1, 20.2);
g) introduction of accessible surface temperature limits (Clause 11);
h) removal of redundancy between 22.113 and 22.114;
i) clarification that 32.2 is not applicable for UV emitted for the tanning function of the appliance.
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments unless that edition precludes it; in that case, the latest edition that does not preclude it is used. It was established on the basis of the sixth edition (2020) of that standard.
- Standard127 pagesEnglish languagesale 15% off
- Standard314 pagesEnglish languagesale 15% off
- Standard82 pagesEnglish and French languagesale 15% off
IEC 60335-2-8:2022 deals with the safety of electric shavers, hair clippers, epilators, appliances used for manicure and pedicure and similar appliances intended for household and similar purposes, their rated voltage being not more than 250 V, including direct current (DC) supplied appliances and battery-operated appliances.
Appliances not intended for normal household use, but which nevertheless possibly pose a source of danger to the public, such as appliances intended to be used by laymen in shops and on farms, are within the scope of this standard. Examples of such appliances are animal shearers.
As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account
– persons (including children) whose physical, sensory or mental capabilities; or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction;
– children playing with the appliance.
Attention is drawn to the fact that
– for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary;
– in many countries additional requirements are specified by national health authorities, national authorities responsible for the protection of labour and similar authorities.
This standard does not apply to
– appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas);
– massage appliances (IEC 60335-2-32);
– beauty care appliances incorporating lasers and intense light sources (IEC 60335-2-113);
– skin beauty care appliances (IEC 60335-2-115);
– appliances for medical purposes (IEC 60601).
This seventh edition cancels and replaces the sixth edition published in 2012, Amendment 1:2015 and Amendment 2:2018. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment with IEC 60335-1:2020;
b) conversion of some notes to normative text (Clause 1, 3.1.9, 19.10, 20.1, 22.103);
c) clarification of holding the appliance with negligible effect on normal operation (3.1.9);
d) addition of requirements for detachable power supply parts (6.2, 21.102, 21.103, 24.2);
e) allowance to waive instructions relating to hot blades on animal shearers and commercial animal clippers based on temperatures measured in Clause 11 (7.12);
f) clarification and consolidation of requirements in 22.26 and 22.36;
g) clarification of applicability of 30.2.2 and 30.2.3;
h) clarification of requirements for interconnection cords for class III constructions.
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments unless that edition precludes it; in that case, the latest edition that does not preclude it is used. It was established on the basis of the sixth edition (2020) of that standard.
- Standard72 pagesEnglish languagesale 15% off
- Standard47 pagesEnglish and French languagesale 15% off
- Standard2 pagesEnglish and French languagesale 15% off
- Standard16 pagesEnglish and French languagesale 15% off
IEC 60335-2-52:2021 is available as IEC 60335-2-52:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60335-2-52:2021 deals with the safety of electric oral hygiene appliances for household and similar purposes, their rated voltage being not more than 250 V, including direct current (DC) supplied appliances and battery-operated appliances.
Examples of appliances that this standard is applicable to are
- oral irrigators;
- toothbrushes.
As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account
- persons (including children) whose physical, sensory or mental capabilities, or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction;
- children playing with the appliance.
Attention is drawn to the fact that
- for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary;
- in many countries additional requirements are specified by the national health authorities, the national authorities responsible for the protection of labour and similar authorities.
This standard does not apply to appliances for medical purposes (IEC 60601).
This fourth edition cancels and replaces the third edition published in 2002, Amendment 1: 2008 and Amendment 2:2017. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the text has been aligned with IEC 60335-1:2020;
b) some notes have been converted to normative text (Clause 1, 11.7, 22.101);
c) clarification of requirements for battery-operated appliances (Clause 1, 11.7, B.11.1);
d) application of test probe 19 has been introduced (8.1.1, 20.2);
e) the stability test has been updated to cover hand-held parts of battery-operated appliances when placed on their charging stand (20.1);
f) a drop test is introduced for hand-held parts of an appliance (21.101);
g) additional strength tests for detachable power supply parts are introduced (21.102);
h) Table B.2 and Table B.3 updated to reflect smaller cell capacities for battery-operated appliances covered by this Part 2 standard.
This Part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments unless that edition precludes it; in that case, the latest edition that does not preclude it is used. It was established on the basis of the sixth edition (2020) of that standard.
- Standard60 pagesEnglish languagesale 15% off
- Standard40 pagesEnglish and French languagesale 15% off
IEC 60335-2-115:2021 deals with the safety of electric appliances for skin beauty care of persons and intended for household, commercial and similar purposes, their rated voltage being not more than 250 V.
Dual supply appliances, either mains-supplied or battery-operated, are regarded as battery-operated appliances when operated in the battery mode.
Examples of appliances that are within the scope of this standard are
– battery-operated appliances and other DC supplied appliances for beauty care;
– appliances with high frequency outputs including equipment for heat-producing effects on the skin;
– appliances with medium frequency outputs including interferential outputs, for skin stimulation or muscle stimulation;
– appliances with low frequency outputs (e.g. faradic currents) for application such as skin stimulation or muscle stimulation;
– appliances with extra-low voltage DC outputs (e.g. galvanic currents), such as electro-epilation (hair removal);
– skin beauty care appliances with ultrasonic outputs;
– appliances having vacuum-pressure functions;
– skin beauty care appliances for melting wax;
– appliances intended to produce surface cooling effect on the skin;
– facial cleaning appliances;
– micro-needling appliances;
– plasma pens.
Appliances covered by this standard can incorporate vapour-producing devices or spray-producing devices.
This standard deals with the common hazards presented by appliances that are encountered by all persons. However, in general, it does not take into account
– persons (including children) whose physical, sensory or mental capabilities; or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction;
– children playing with the appliance.
Attention is drawn to the fact that
– it is recognized that persons having very extensive and complex disabilities can have needs beyond the level addressed in this standard.
– for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary;
– in many countries, additional requirements can be specified by the national health authorities, the national authorities responsible for the protection of labour and similar authorities.
This standard does not apply to
– appliances intended exclusively for industrial purposes;
– appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas);
– shavers, hair clippers and similar appliances (IEC 60335-2-8);
– blankets, pads, clothing and similar flexible heating appliances (IEC 60335-2-17);
– appliances for skin or hair care such as facial saunas, hand dryers, foot care appliances (IEC 60335-2-23);
– spray tanning appliances;
– appliances for skin exposure to optical radiation (IEC 60335-2-27);
– sauna heating appliances and infrared cabins (IEC 60335-2-53);
– cosmetic and beauty care appliances incorporating lasers and intense light sources (IEC 60335-2-113);
– appliances intended for medical purposes (IEC 60601);
– radio frequency appliances without contact to the skin;
– ultrasound appliances provided with focusing ultrasound transducers.
This part 2 is to be used in conjunction with the fifth edition of IEC 60335-1:2010 and its amendments.
The contents of the corrigendum of April 2022 have been included in this copy.
- Standard91 pagesEnglish and French languagesale 15% off
IEC 60335-2-32:2019 is available as IEC 60335-2-32:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60335-2-32:2019 deals with the safety of electric massage appliances for household and similar purposes, their rated voltage being not more than 250 V for single phase appliances and 480 V for other appliances. Examples of appliances within the scope of this standard are:
- foot massagers;
- water filled foot massagers;
- hand-held massagers;
- massage beds;
- massage belts;
- massage chairs;
- massage pads.
Appliances not intended for normal household use but that nevertheless may be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account:
- persons (including children) whose physical, sensory or mental capabilities or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction;
- children playing with the appliance.
Attention is drawn to the fact that:
- for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary;
- in many countries additional requirements are specified by the national health authorities, the national authorities responsible for the protection of labour and similar authorities.
This standard does not apply to
- appliances intended exclusively for industrial purposes;
- appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas);
- electric foot care appliances that do not contain motors and other electric appliances for the care of skin or hair (IEC 60335-2-23)
- electric appliances for beauty care of persons and intended for household, commercial and similar purposes (IEC 60335-2-115).
This fifth edition cancels and replaces the fourth edition published in 2002, Amendment 1: 2008 and Amendment 2:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- aligns the text with IEC 60335-1, Ed 5, and its Amendments 1 and 2;
- note is converted to normative text (11.8);
- additional requirements for temperatures of external accessible surfaces (Clause 11);
- alternative stability requirements for hand-held appliances (20.2);
- new mechanical strength test for hand-held appliances (21.1, 21.101).
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments. It was established on the basis of the fifth edition (2010) of that standard.
- Standard50 pagesEnglish languagesale 15% off
- Standard33 pagesEnglish and French languagesale 15% off
- Standard5 pagesEnglish and French languagesale 15% off
IEC 60335-2-27:2019 is available as IEC 60335-2-27:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60335-2-27:2019 deals with the safety of electrical appliances incorporating emitters for exposing the skin to optical radiation (wavelength 100 nm to 1 mm), for household and similar use, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances.
Battery-operated appliances and other DC supplied appliances are within the scope of this standard. Dual supply appliances, either mains-supplied or battery-operated, are regarded as battery-operated appliances when operated in the battery mode.
As far as practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons using the appliances in tanning salons, beauty parlours and similar premises or at home. However, in general, it does not take into account
– persons (including children) whose physical, sensory or mental capabilities or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction;
– children playing with the appliance.
Attention is drawn to the fact that
– for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements can be necessary;
– in many countries, additional requirements are specified by the national health authorities, the national authorities responsible for the protection of labour and similar authorities;
– IEC 60598-1 is applicable as far as is reasonable.
This standard does not apply to
– appliances for skin or hair care (IEC 60335-2-23);
– sauna heating appliances and infrared cabins (IEC 60335-2-53);
– cosmetic and beauty care appliances incorporating lasers and intense light sources (IEC 60335-2-113)
– appliances for medical purposes (IEC 60601);
– appliances that use UV radiation for purposes other than tanning the skin;
– appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas).
This sixth edition cancels and replaces the fifth edition published in 2009, Amendment 1:2012 and Amendment 2:2015. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
– aligns the text with IEC 60335-1, Ed 5, and its Amendments 1 and 2;
– luminous transmission has been defined (3.1.102);
– requirements for testing parts of the appliance that are operated unattended are added (30.2).
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments. It was established on the basis of the fifth edition (2010) of that standard.
Keywords: Tanning, Tanning bed
- Standard117 pagesEnglish languagesale 15% off
- Standard75 pagesEnglish and French languagesale 15% off
- Standard9 pagesEnglish and French languagesale 15% off
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.