IEC 60512-27-100:2011
(Main)Connectors for electronic equipment - Tests and measurements - Part 27-100: Signal integrity tests up to 500 MHz on 60603-7 series connectors - Tests 27a to 27g
- Abstract
IEC 60512-27-100:2011 specifies the test methods for transmission performance for IEC 60603-7 series connectors up to 500 MHz. It is also suitable for testing lower frequency connectors if they meet the requirements of the detail specifications and of this standard. The test methods provided are: - insertion loss, - return loss, - near-end crosstalk (NEXT), - far-end crosstalk (FEXT), - transverse conversion loss (TCL) and - transverse conversion transfer loss (TCTL). For the transfer impedance (Zt) test, see IEC 60512-26-100 and for the coupling attenuation, see IEC 62153-4-12.
- Status
- Published
- Publication Date
- 06-Dec-2011
- Technical Committee
- SC 48B - Electrical connectors
- Drafting Committee
- WG 5 - Test methods
- Current Stage
- PPUB - Publication issued - 60 Publication
- Start Date
- 07-Dec-2011
- Due Date
- 15-Jan-2012
- Completion Date
- 15-Jan-2012
Buy Documents
IEC 60512-27-100:2011 - Connectors for electronic equipment - Tests and measurements - Part 27-100: Signal integrity tests up to 500 MHz on 60603-7 series connectors - Tests 27a to 27g Released:12/7/2011
Overview
IEC 60512-27-100:2011 is an international standard published by the International Electrotechnical Commission (IEC) that specifies test methods for evaluating the signal integrity of IEC 60603-7 series connectors. This standard covers comprehensive signal integrity tests on electronic equipment connectors operating up to 500 MHz, ensuring reliable transmission performance. It is applicable not only to connectors within the 60603-7 series but also suitable for testing connectors designed for lower frequency ranges, provided they meet the detailed specification requirements.
This standard defines critical measurements including insertion loss, return loss, near-end crosstalk (NEXT), far-end crosstalk (FEXT), transverse conversion loss (TCL), and transverse conversion transfer loss (TCTL). It guides testing best practices and provides detailed test arrangements, procedures, and accuracy criteria to ensure consistent, reproducible results.
Key Topics
- Insertion Loss (Test 27a): Measures signal attenuation as it passes through the connector, crucial for understanding connector impact on signal amplitude.
- Return Loss (Test 27b): Assesses reflected signals caused by impedance mismatches, which affect signal integrity.
- Near-End Crosstalk (NEXT, Test 27c): Evaluates signal coupling between neighboring conductor pairs at the transmitting end, important to minimize interference.
- Far-End Crosstalk (FEXT, Test 27d): Measures crosstalk at the receiving end, critical for assessing connector isolation characteristics.
- Transverse Conversion Loss (TCL, Test 27f): Quantifies conversion between differential and common modes within the connector.
- Transverse Conversion Transfer Loss (TCTL, Test 27g): Measures signal loss during mode conversion, helping to characterize connector shielding effectiveness.
- Test Free Connector (TFC): The standard describes construction and qualification of TFCs used as reference artefacts in testing NEXT, FEXT, and return loss.
- Measurement Setup: Specifies detailed instrumentation, calibration techniques, and interface requirements to ensure accurate testing results.
- Balun Usage: Clarifies requirements on balun devices to convert between differential and common mode signals for specific measurements.
- Accuracy and Reporting: Defines procedures to document test results and ensure measurement precision.
Applications
IEC 60512-27-100:2011 facilitates the design, verification, and quality assurance of connectors used in various electronic and telecommunication equipment where signal integrity is crucial. Applications include:
- Telecommunications Infrastructure: Testing RJ45 and other modular connectors to guarantee high-performance data transmission up to 500 MHz, relevant for Ethernet and network equipment.
- Data Centers and Networking: Ensuring optimal connector performance in high-density cabling systems to reduce signal degradation and crosstalk.
- Electronic Equipment Manufacturing: Qualification of connectors in consumer electronics, industrial automation, and medical devices where signal quality impacts functionality.
- Connector Design and Development: Providing manufacturers with standardized test methods to evaluate prototypes and validate design improvements for superior signal performance.
- Compliance Testing: Assisting labs and manufacturers in meeting international interoperability and performance standards by adhering to IEC testing guidelines.
Related Standards
- IEC 60603-7 Series: Defines the generic requirements for modular connectors that IEC 60512-27-100:2011 focuses on testing.
- IEC 60512-26-100: Specifies test methods for measuring transfer impedance (Zt) complementary to signal integrity tests in this standard.
- IEC 62153-4-12: Details coupling attenuation test procedures relevant to shielding effectiveness, referenced as complementary to IEC 60512-27-100.
- Additional IEC 60512 Parts: Cover a wide range of mechanical and electrical test methods for connectors, supporting comprehensive performance evaluation.
By following the rigorous test methods outlined in IEC 60512-27-100:2011, manufacturers and testing laboratories can ensure the reliability and high-quality transmission performance of IEC 60603-7 series connectors. This standard contributes to advancing connector technology and maintaining interoperability within global electronic and data communication systems.
Buy Documents
IEC 60512-27-100:2011 - Connectors for electronic equipment - Tests and measurements - Part 27-100: Signal integrity tests up to 500 MHz on 60603-7 series connectors - Tests 27a to 27g Released:12/7/2011
Frequently Asked Questions
IEC 60512-27-100:2011 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Connectors for electronic equipment - Tests and measurements - Part 27-100: Signal integrity tests up to 500 MHz on 60603-7 series connectors - Tests 27a to 27g". This standard covers: IEC 60512-27-100:2011 specifies the test methods for transmission performance for IEC 60603-7 series connectors up to 500 MHz. It is also suitable for testing lower frequency connectors if they meet the requirements of the detail specifications and of this standard. The test methods provided are: - insertion loss, - return loss, - near-end crosstalk (NEXT), - far-end crosstalk (FEXT), - transverse conversion loss (TCL) and - transverse conversion transfer loss (TCTL). For the transfer impedance (Zt) test, see IEC 60512-26-100 and for the coupling attenuation, see IEC 62153-4-12.
IEC 60512-27-100:2011 specifies the test methods for transmission performance for IEC 60603-7 series connectors up to 500 MHz. It is also suitable for testing lower frequency connectors if they meet the requirements of the detail specifications and of this standard. The test methods provided are: - insertion loss, - return loss, - near-end crosstalk (NEXT), - far-end crosstalk (FEXT), - transverse conversion loss (TCL) and - transverse conversion transfer loss (TCTL). For the transfer impedance (Zt) test, see IEC 60512-26-100 and for the coupling attenuation, see IEC 62153-4-12.
IEC 60512-27-100:2011 is classified under the following ICS (International Classification for Standards) categories: 31.220.10 - Plug-and-socket devices. Connectors. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 60512-27-100:2011 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
IEC 60512-27-100 ®
Edition 1.0 2011-12
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Connectors for electronic equipment – Tests and measurements –
Part 27-100: Signal integrity tests up to 500 MHz on 60603-7 series connectors –
Tests 27a to 27g
Connecteurs pour équipements électroniques – Essais et mesures –
Partie 27-100: Essais d’intégrité des signaux jusqu’à 500 MHz sur les
connecteurs de la série CEI 60603-7 – Essais 27a à 27g
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.
IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 60512-27-100 ®
Edition 1.0 2011-12
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Connectors for electronic equipment – Tests and measurements –
Part 27-100: Signal integrity tests up to 500 MHz on 60603-7 series connectors –
Tests 27a to 27g
Connecteurs pour équipements électroniques – Essais et mesures –
Partie 27-100: Essais d’intégrité des signaux jusqu’à 500 MHz sur les
connecteurs de la série CEI 60603-7 – Essais 27a à 27g
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX XB
ICS 31.220.10 ISBN 978-2-88912-823-5
– 2 – 60512-27-100 © IEC:2011
CONTENTS
FOREWORD . 6
1 Scope and object . 8
2 Normative references . 8
3 Terms, definitions, acronyms and symbols . 9
3.1 Terms and definitions . 9
3.1.1 Test Free Connector (TFC) . 9
3.2 Acronyms . 9
3.3 Symbols . 10
4 Overall test arrangement . 10
4.1 Test instrumentation . 10
4.2 Coaxial cables and interconnect for network analysers . 11
4.3 Measurement precautions . 11
4.4 Balun requirements . 11
4.5 Interfacing . 12
4.6 Reference components for calibration . 13
4.6.1 Reference loads for calibration . 13
4.6.2 Reference cables for calibration . 14
4.7 Termination loads for termination of conductor pairs . 14
4.7.1 General . 14
4.7.2 Resistor terminations . 14
4.7.3 Balun terminations . 15
4.7.4 Termination types . 15
4.8 Termination of screens . 15
4.9 Test specimen and reference planes . 15
4.9.1 General . 15
4.9.2 Interconnections between device under test (DUT) and the
calibration plane . 16
5 Connector measurement up to 500 MHz . 17
5.1 General . 17
5.2 Insertion loss, Test 27a . 17
5.2.1 Object . 17
5.2.2 Free connector for insertion loss. 17
5.2.3 Test method . 17
5.2.4 Test set-up . 17
5.2.5 Procedure . 18
5.2.6 Test report . 18
5.2.7 Accuracy . 19
5.3 Return loss, Test 27b . 19
5.3.1 Object . 19
5.3.2 Free connector for return loss . 19
5.3.3 Test method . 19
5.3.4 Test set-up . 19
5.3.5 Procedure . 19
5.3.6 Test report . 19
5.3.7 Accuracy . 19
5.4 Near-end crosstalk (NEXT), Test 27c . 20
60512-27-100 © IEC:2011 – 3 –
5.4.1 Object . 20
5.4.2 Free connector for NEXT . 20
5.4.3 Test method . 20
5.4.4 Test set-up . 20
5.4.5 Procedure . 21
5.4.6 Test report . 24
5.4.7 Accuracy . 24
5.5 Far-end crosstalk (FEXT), Test 27d . 24
5.5.1 Object . 24
5.5.2 Free connector for FEXT . 24
5.5.3 Test method . 24
5.5.4 Test set-up . 24
5.5.5 Procedure . 25
5.5.6 Test report . 25
5.5.7 Accuracy . 26
5.6 Transfer impedance (Zt) . 26
5.7 Transverse conversion loss (TCL), Test 27f . 26
5.7.1 Object . 26
5.7.2 Free connector for TCL . 26
5.7.3 Test method . 26
5.7.4 Test set-up . 26
5.7.5 Procedure . 27
5.7.6 Test report . 30
5.7.7 Accuracy . 30
5.8 Transverse conversion transfer loss (TCTL), Test 27g . 30
5.8.1 Object . 30
5.8.2 Free connector for TCTL . 30
5.8.3 Test method . 30
5.8.4 Test set-up . 30
5.8.5 Procedure . 31
5.8.6 Test report . 32
5.8.7 Accuracy . 32
5.9 Coupling attenuation . 32
6 Construction and qualification of TFCs for NEXT, FEXT and return loss
measurements . 32
6.1 General . 32
6.1.1 Introductory remarks . 32
6.1.2 Delay measurements . 33
6.2 TFC near-end crosstalk (NEXT). 36
6.2.1 General . 36
6.2.2 Procedure for mating a TFC to the direct fixture . 36
6.2.3 TFC NEXT loss measurement . 37
6.2.4 TFC NEXT loss requirements . 38
6.3 TFC far-end crosstalk (FEXT) . 39
6.3.1 TFC FEXT loss measurement . 39
6.3.2 TFC FEXT loss requirements . 39
6.4 TFC return loss . 40
6.4.1 General . 40
6.4.2 TFC return loss reverse direction qualification procedure . 40
– 4 – 60512-27-100 © IEC:2011
6.4.3 Test plug return loss forward direction qualification procedure . 40
6.4.4 TFC return loss requirements . 46
6.5 Test fixtures for TFC testing . 47
6.5.1 Requirements for TFC direct fixtures . 47
Annex A (informative) Impedance controlled measurement fixture . 49
Annex B (normative) Termination of balun . 63
Bibliography . 65
Figure 1 – 180° hybrid used as a balun . 11
Figure 2 – Measurement configurations for test balun qualification . 13
Figure 3 – Calibration of reference loads . 14
Figure 4 – Resistor termination networks . 14
Figure 5 – Definition of reference planes. 16
Figure 6 – Measuring set-up . 18
Figure 7 – Example for NEXT measurements . 21
Figure 8 – Example for FEXT measurements for DM and CM terminations . 25
Figure 9 – Example of TCL measurement . 27
Figure 10 – Coaxial lead attenuation calibration. . 28
Figure 11 – Back-to-back balun insertion loss measurement . 28
Figure 12 – Configuration for balun CM insertion loss calibration . 29
Figure 13 – Schematic for balun CM insertion loss calibration . 29
Figure 14 – Example of TCTL measurement . 31
Figure 15 – Calibration and interface planes and port extensions . 33
Figure 16 – Examples of direct fixture short, open, load, and through artefacts . 35
Figure 17 – Modular free connector placed into the free connector clamp . 36
Figure 18 – Guiding the free connector into position . 37
Figure 19 – TFC direct fixture . 37
Figure 20 – illustration of TFC NEXT measurement in the forward direction . 38
Figure 21 – Example of suitable return loss de-embedding reference socket. 42
Figure 22 – Flow chart for determination of reference fixed connector S-parameters . 43
Figure 23 – Representation of a mated connection by two cascaded networks . 43
Figure 24 – Return loss de-embedding reference plug terminated with LOAD resistors . 44
Figure 25 – Return loss test plug calibration and interface planes . 44
Figure 26 – Flow chart of determination of return loss test plug properties . 46
Figure 27 – Direct fixture mating dimensions A . 47
Figure 28 – Direct fixture mating dimensions B . 48
Figure 29 – Direct fixture mating dimension C . 48
Figure A.1 – Test head assembly with baluns attached . 49
Figure A.2 – Test balun interface pattern . 50
Figure A.4 – Test head assembly showing shielding between baluns . 51
Figure A.5 – Balun test 2 fixture assembly . 52
Figure A.6 – Free connector direct fixture, DPMF-2 view 1 . 53
Figure A.7 – Free connector direct fixture, DPMF-2 view 2 . 53
Figure A.8 – Exploded assembly of the direct fixture . 54
60512-27-100 © IEC:2011 – 5 –
Figure A.9 – PCB based free connector . 55
Figure A.10 – TP6A PCB based free connector assembly with adapter . 55
Figure A.11 – An example of a connecting hardware measurement configuration. 56
Figure A.12 – Test fixture interface . 57
Figure A.13 – Open calibration standard applied to test interface . 57
Figure A.14 – Short calibration standard applied to test interface . 58
Figure A.15 – Load calibration standard applied to test interface . 58
Figure A.16 – Back-to-back through standard applied to test interface . 59
Figure A.17 – TFC attached to the test interface . 59
Figure A.18 – Direct fixture mounted to the test head interface . 60
Figure A.19 – Calibration plane . 60
Figure A.20 – Through calibration . 61
Figure A.21 – Test setup for twisted-pair return 2 loss measurement . 61
Figure A.22 – Method to minimize distance between planes. 62
Figure B.1 – Balanced attenuator for balun centre tap grounded . 63
Figure B.2 – Balanced attenuator for balun centre tap open . 64
Table 1 – Test balun performance characteristics . 12
Table 2 – Interconnection return loss . 17
Table 3 – Uncertainty band of return loss measurement at frequencies below 100 MHz . 20
Table 4 – Uncertainty band of return loss measurement at frequencies above 100 MHz. 20
Table 5a – Free connector TFC NEXT loss limit vectors for connectors specified up to
100 MHz . 23
Table 5b – Free connector TFC NEXT loss limit vectors for connectors specified from
1-250 MHz and from 1 MHz to 500 MHz . 23
Table 6 – connecting hardware NEXT loss for Case 1 and Case 4 . 24
Table 7 – TFC NEXT loss ranges . 39
Table 8 – TFC FEXT loss ranges . 40
Table 9 – De-embedding return loss reference fixed connector assembly standard
vectors . 42
Table 10 – Return loss requirements for TFCs . 47
Table 11 – Direct fixture performance . 48
– 6 – 60512-27-100 © IEC:2011
INTERNATIONAL ELECTROTECHNICAL COMMISSION
______________
CONNECTORS FOR ELECTRONIC EQUIPMENT –
TESTS AND MEASUREMENTS –
Part 27-100: Signal integrity tests up to 500 MHz
on 60603-7 series connectors –
Tests 27a to 27g
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60512-27-100 has been prepared by subcommittee 48B:
Connectors, of IEC technical committee 48: Electromechanical components and mechanical
structures for electronic equipment.
The text of this standard is based on the following documents:
FDIS Report on voting
4B/2262/FDIS 48B/2275/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
60512-27-100 © IEC:2011 – 7 –
A list of all parts of IEC 60512 series, under the general title Connectors for electrical
equipment – Tests and measurements can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.
– 8 – 60512-27-100 © IEC:2011
CONNECTORS FOR ELECTRONIC EQUIPMENT –
TESTS AND MEASUREMENTS –
Part 27-100: Signal integrity tests up to 500 MHz
on 60603-7 series connectors –
Tests 27a to 27g
1 Scope and object
This part of IEC 60512 specifies the test methods for transmission performance for
IEC 60603-7 series connectors up to 500 MHz. It is also suitable for testing lower frequency
connectors if they meet the requirements of the detail specifications and of this standard.
The test methods provided here are:
– insertion loss, test 27a;
– return loss, test 27b;
– near-end crosstalk (NEXT) test 27c;
– far-end crosstalk (FEXT), test 27d;
– transverse conversion loss (TCL), test 27f;
– transverse conversion transfer loss (TCTL), test 27g;
For the transfer impedance (Zt) test, see IEC 60512-26-100, test 26e.
For the coupling attenuation, see IEC 62153-4-12.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60050–581, International Electrotechnical Vocabulary (IEV) – Part 581:
Electromechanical components for electronic equipment
IEC 60512-1, Connectors for electronic equipment – Tests and measurements –
Part 1: General
IEC 60512-1-100, Connectors for electronic equipment – Tests and measurements –
Part 1-100: General - Applicable publications
IEC 60512-26-100, Connectors for electronic equipment – Tests and measurements –
Part 26-100: Measurement setup, test and reference arrangements and measurements for
connectors according to IEC 60603-7 – Tests 26a to 26g
IEC 60603-7 (all parts), Connectors for electronic equipment
IEC 60603-7, 2008: Connectors for electronic equipment – Part 7: Detail specification for
8-way, unshielded, free and fixed connectors
60512-27-100 © IEC:2011 – 9 –
IEC 61076-1, Connectors for electronic equipment – Product requirements – Part 1: Generic
specification
IEC 61156 (all parts), Multicore and symmetrical pair/quad cables for digital communications
IEC 61169-16, Radio-frequency connectors – Part 16: Sectional specification – RF coaxial
connectors with inner diameter of outer conductor 7 mm (0,276 in) with screw coupling –
Characteristic impedance 50 ohms (75 ohms) (Type N)
IEC 62153-4-12, Metallic communication cable test methods – Part 4-12: Electromagnetic
compatibility (EMC) – Coupling attenuation or screening attenuation of connecting hardware –
Absorbing clamp method
3 Terms, definitions, acronyms and symbols
NOTE It should be noted that this document, although having a close relationship with corresponding documents,
which use different terminology to that used in those documents.
3.1 Terms and definitions
For the purposes of this document, the terms and definitions of IEC 60050(581), IEC 61076-1,
IEC 60512-1, IEC 60603-7 as well as the following, apply.
3.1.1 Test Free Connector (TFC)
free connector, which is constructed such that it is a test artefact, is known as a
Test Free Connector (TFC)
3.2 Acronyms
For ease of reference, acronyms used in this standard are given below.
ACRF Attenuation to crosstalk ratio, far-end
CM Common mode
CMR Common mode rejection
DM Differential mode
DMCM Differential mode plus common mode
DUT Device under test
EIA Electronic Industries Alliance
ELTCTL Equal level transverse conversion transfer loss
FEXT Far-end crosstalk
F/UTP Foil (surrounding) unscreened twisted-pairs
ICEA Insulated Cable Engineers Association
IDC Insulation displacement connection
IPC Insulation piercing connection
NEXT Near-end crosstalk
OSB Output signal balance
PSAACRF Power sum attenuation to alien crosstalk ratio, far-end
PSACRF Power sum attenuation to crosstalk ratio, far-end
PSANEXT Power sum alien near-end crosstalk
PSFEXT Power sum far-end crosstalk
– 10 – 60512-27-100 © IEC:2011
PSNEXT Power sum near-end crosstalk
RL Return Loss
TCTL Transverse conversion transfer loss
TFC Test free connector
TIA Telecommunications Industry Association
U/UTP Unshielded twisted-pair
Zt Transfer impedance
3.3 Symbols
A terminal of balun
a insertion loss; equation coefficient
B terminal of balun
b equation coefficient
C terminal of balun
D terminal of balun
f frequency
J fixed connector; socket
k equation coefficient
P free connector
R resistor
x
S normalized S-parameter
xy
T T-parameter
xy
TD time delay
Zt transfer impedance
Ω Ohms
% percent
° degree
4 Overall test arrangement
4.1 Test instrumentation
All test instrumentation shall be qualified for use over the frequency range of 1 MHz to
500 MHz.
These test procedures require the use of a vector network analyser. The analyser should
have the capability of full 2-port calibrations. The analyser shall cover the frequency range of
1 MHz to 500 MHz at least.
When used, at least two test baluns are required in order to perform measurements with
balanced symmetrical signals. The requirements for the baluns are given in 4.4.
Optionally; multi-port network analyzers for balun-less test set-up may be used.
Reference loads and cables are needed for the calibration of the set-up. Requirements for the
reference loads, and cables are given in 4.6.1 and 4.6.2 respectively.
60512-27-100 © IEC:2011 – 11 –
Termination loads are needed for termination of pairs, used and unused, which are not
terminated by the test baluns. Requirements for the termination loads are given in 4.7.
An absorbing clamp and ferrite absorbers are needed for the coupling attenuation
measurements. The requirements for these items are given in IEC 62153-4-12.
4.2 Coaxial cables and interconnect for network analysers
Lengths of coaxial cables used to connect the network analyser to the baluns shall be as
short as possible. (It is recommended that they do not exceed 600 mm each.)
The baluns shall be electrically bonded to a common ground plane. For crosstalk
measurements, a test fixture may be used, in order to reduce residual crosstalk (see
Annex A).
Balanced interconnect and associated connecting hardware used to connect between the test
equipment and the connector under test shall meet the requirements given in 4.9.2.
4.3 Measurement precautions
To ensure a high degree of reliability for transmission measurements, the following
precautions are required.
a) Any measurement that is to be used in a de-embedding or re-embedding process, whether
vector or matrix, shall have its phase adjusted to the free connector phase reference
plane. Methods to do this are provided.
b) Consistent and stable balun and resistor loads shall be used for each pair throughout the
test sequence.
c) Cable and adapter discontinuities, as introduced by physical flexing, sharp bends and
restraints shall be avoided before, during and after the tests.
d) Consistent test methodology and terminations (baluns or resistors) shall be used at all
stages of transmission performance qualifications.
The relative spacing of conductors in the pairs shall be preserved throughout the tests to
the greatest extent possible.
e) The balance of the cables is maintained to the greatest extent possible by consistent
conductor lengths and pair twisting to the point of load.
f) The sensitivity to set-up variations for these measurements at high frequencies demands
attention to details for both the measurement equipment and the procedures.
4.4 Balun requirements
The baluns may be balun transformers or 180° hybrids with attenuators to improve matching if
needed. Figure 1 show s such an arrangement .
Attenuator
180° hybrid
Test port
To network analyzer
Attenuator
IEC 117/05
Figure 1 – Optional 180° hybrid used as a balun
– 12 – 60512-27-100 © IEC:2011
The specifications for the baluns apply for the whole frequency range for which they are used.
Baluns shall be RFI shielded and shall comply with the specifications listed in Table 1.
Table 1 – Test balun performance characteristics
Parameter Frequency (MHz) Value
a
Impedance, primary
1 ≤ f ≤ 500 50 Ω unbalanced
Impedance, secondary 1 ≤ f ≤ 500 100 Ω balanced
Insertion loss 1 ≤ f ≤ 500 2,0 dB maximum
1 ≤ f < 15 12 dB minimum
b
Return loss, bi-directional
15 ≤ f ≤ 500 20 dB minimum
1 ≤ f < 15 15 dB minimum
b
Return loss, CM 15 ≤ f < 400 20 dB minimum
15 dB minimum
400 ≤ f ≤ 500
Power rating 1 ≤ f ≤ 500 0,1 watt minimum
1 ≤ f < 100 60 dB minimum
b
Longitudinal balance
100 ≤ f ≤ 500 50 dB minimum
b
Output signal balance 50 dB minimum
1 ≤ f ≤ 500
b
CM rejection 1 ≤ f ≤ 500 50 dB minimum
a
Primary impedance may differ, if necessary, to accommodate analyzer outputs other than 50 Ω.
b
Measured per ITU-T (formerly CCITT) Recommendation G.117 with the network analyzer calibrated using a
50 Ω load.
4.5 Interfacing
For ease of interfacing to test fixtures, a pin and socket interface with dimensions as shown in
informative Clause A.2 is recommended.
Figure 2 depicts the proper test configurations for qualifying test baluns to the requirements of
this Standard.
60512-27-100 © IEC:2011 – 13 –
Balun Port Description Insertion Loss (2 Units Back-to-Back)
A A A
D D D
C B C B B C
A-B: 100 Ω Balanced
50 Ω 50 Ω
C: 50 Ω Common-Mode
D: 50 Ω Unbalanced
Return Loss (50:100 ohm) Return Loss (100:50 ohm)
A A A
50 Ω
D 100 Ω D D
C B C B B C
50 Ω 50 Ω 50 Ω
Calibration Plane
Common-Mode Return Loss
Longitudinal Balance
50 Ω
50 Ω
A A
50 Ω 25 Ω
25 Ω
D D
C B C B
50 Ω
50 Ω
Output Signal Balance
Common-Mode Rejection
50 Ω 50 Ω
A A
50 Ω 50 Ω
D D
C B C B
50 Ω 50 Ω
50 Ω 50 Ω
IEC 2584/11
Figure 2 – Measurement configurations for test balun qualification
4.6 Reference components for calibration
4.6.1 Reference loads for calibration
To perform a one or two-port calibration of the test equipment, a short circuit, an open circuit
and a reference load are required. These devices shall be used to obtain a calibration.
The reference load shall be calibrated against a calibration reference, which shall be a 50 Ω
load, traceable to an international reference standard. Two 100 Ω reference loads in parallel
shall be calibrated against the calibration reference. The reference loads for calibration shall
be placed in an N-type connector according to IEC 60169-16, meant for panel mounting,
– 14 – 60512-27-100 © IEC:2011
which is machined flat on the back side (see Figure 3). The loads shall be fixed to the flat side
of the connector, distributed evenly around the centre conductor. A network analyser shall be
calibrated, 1-port full calibration, with the calibration reference. Thereafter, the return loss of
the reference loads for calibration shall be measured. The verified return loss shall be >46 dB
at frequencies up to 100 MHz and >40 dB at frequencies above 100 MHz and up to the limit
for which the measurements are to be carried out.
Machined flat
Loads for calibration
N type connector
IEC 118/05
Figure 3 – Calibration of reference loads
4.6.2 Reference cables for calibration
As a minimum, the reference cable that is used to perform the calibration of the test set-up
shall satisfy the requirement of the same performance according to the IEC 61156 series as
the performance of the connector. The reference cable shall be a length of horizontal cable
for which the sheath is preserved. One of the pairs of the reference cable is used for the
calibrations. The total length of the reference cable shall be according to the length of the
measurement cables as outlined in the calibration procedures for the various tests. Both ends
of the reference cable shall be well prepared, so that the twisting is maintained up to the test
ports.
4.7 Termination loads for termination of conductor pairs
4.7.1 General
DM plus CM (DMCM) terminations, as shown in Figure 4 on the left, shall be used on all
active pairs under test, except when measuring return loss, where DM only resistor
terminations are recommended. DMCM resistor terminations shall be used on all inactive
pairs and on the opposite ends of active pairs for NEXT loss and FEXT loss testing. Inactive
pairs for return loss testing may be terminated with DM or DMCM resistor terminations. Balun
terminations may be used on the far-end of all inactive pairs provided that their DM and CM
return loss performance characteristics meet the minimum performance of the specified
resistor networks.
4.7.2 Resistor terminations
50 Ω ± 0,1 % 50 Ω ± 0,1 %
Ω ±
100 0,1 %
25 Ω ± 1 %
Differential mode only
Differential mode plus
resistor termination
common mode resistor termination
IEC 2585/11
Figure 4 – Resistor termination networks
60512-27-100 © IEC:2011 – 15 –
Small geometry chip resistors shall be used for the construction of resistor terminations. The
two 50 Ω DM terminating resistors shall be matched to within 0,1 % at DC. The length of
connections to impedance terminating resistors shall be minimized. Lead lengths of 2 mm or
less are recommended.
4.7.3 Balun terminations
Baluns used for termination shall comply with the requirements of 4.4. The CM termination
resistor applied to the CM port of the balun shall be 50 Ω ± 1 %.
4.7.4 Termination types
The performance of impedance matching resistor termination networks shall be verified by
measuring the return loss of the termination at the calibration plane. For this measurement, a
one port calibration is required using a traceable reference load. As described in 4.6.
The DM return loss of the load termination shall exceed 20-20log (f/500).
...