Standards Content (Sample)


INTERNATIONAL IEC
STANDARD
60335-2-27
AMENDMENT 1
2000-02
Amendment 1
Safety of household and similar
electrical appliances –
Part 2-27:
Particular requirements for appliances
for skin exposure to ultraviolet and
infrared radiation
Amendement 1
Sécurité des appareils électrodomestiques
et analogues –
Partie 2-27:
Règles particulières pour les appareils d'exposition
de la peau aux rayonnements ultraviolets et infrarouges

 IEC 2000  Copyright - all rights reserved
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
Commission Electrotechnique Internationale
PRICE CODE
D
International Electrotechnical Commission
For price, see current catalogue

– 2 – 60335-2-27 Amend. 1 © IEC:2000(E)

FOREWORD
This amendment has been prepared by IEC technical committee 61: Safety of household and

similar electrical appliances.

The text of this amendment is based on the following documents:

FDIS Report on voting
61/1760/FDIS 61/1781/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
A bilingual version of this amendment may be issued at a later date.
______________
2 Definitions
2.101 Delete from the definition:
disregarding the screening effect of any screen or guard that may enclose it.
2.107 Replace the definition by:
effective irradiance
irradiance of electromagnetic radiation weighted according to a specified action spectrum
7 Marking and instructions
7.1 At the end of the second paragraph, replace "emitter" by "emitters which are
recommended for use".
Replace the text of the second WARNING by:

Ultraviolet radiation may cause injury to the eyes and skin, such as skin ageing and
eventually skin cancer.
Read instructions carefully.
Wear the protective goggles provided.
Certain medicines and cosmetics may increase sensitivity.

60335-2-27 Amend. 1 © IEC:2000(E) – 3 –

7.12 Replace the third dashed item and note 1 by:

– recommended schedule of exposure specifying duration and intervals taking into account

the UV emitter characteristics, distances and skin sensitivity.

NOTE 1 The recommended exposure time for the first session for untanned skin is not to be less than 1 min. It is

to correspond to a dose not exceeding 100 J/m , weighted according to the UV action spectrum of figure 101, or to

the result of a test on a small area of the skin.

In note 2, replace "UV action curve" by "UV action spectrum".

Replace the sixth and seventh dashed items by:

– identification of alternative components which may influence the ultraviolet radiation, such
as filters and reflectors;
– identification
...