IEC 60360:1998
(Main)Standard method of measurement of lamp cap temperature rise
General Information
- Abstract
Describes the standard method of measurement of lamp cap temperature rise which is to be used when testing tungsten filament or discharge lamps for compliance with the limits. Covers the method of test and the specifications for test lampholders for lamps fitted with various sizes of ES and BC caps. This method has been used widely for incandescent lamps but its application is not limited to that type of lamp. The contents of the corrigendum of March 1999 have been included in this copy.
- Status
- Published
- Publication Date
- 09-Jun-1998
- Technical Committee
- SC 34A - Electric light sources
- Drafting Committee
- WG 6 - TC 34/SC 34A/WG 6
- Current Stage
- PPUB - Publication issued
- Start Date
- 30-Jun-1998
- Completion Date
- 31-Jul-1998
Overview
IEC 60360:1998 is an international standard established by the International Electrotechnical Commission (IEC) that defines the standard method of measurement of lamp cap temperature rise. This method is critical for testing tungsten filament and discharge lamps to ensure they comply with temperature rise limits, which is a key factor for safety and longevity in lighting applications. The standard primarily covers the test procedures and specifications for test lampholders compatible with different lamp cap sizes such as Edison Screw (ES) and Bayonet Caps (BC).
Originally developed for incandescent lamps, the standard's application also extends to other lamp types. Updated to include the corrigendum of March 1999, IEC 60360:1998 reflects modern testing practices and ensures consistent and reproducible temperature measurements.
Key Topics
Scope and Applicability
IEC 60360 details the method used to measure the temperature rise on the lamp cap via a test lampholder. It applies to incandescent and discharge lamps, providing a uniform framework for assessing compliance against safety and performance limits as referenced in IEC 60432.Measurement Methodology
Key to the method is the use of a standard test lampholder rather than measuring the temperature on a bare lamp cap. This leads to:- Closer approximation to real operating conditions.
- Improved reproducibility by minimizing the influence of cap material variations or surface finish.
- Averaged temperature readings that better represent heat transfer to luminaires.
- Reduced measurement time with thermocouples permanently fixed to the test lampholder.
Test Setup and Conditions
The standard specifies:- Types and dimensions of test lampholders for ES and BC caps.
- Installation procedures for lamps within test enclosures.
- Use of thermocouples positioned to measure temperature rise accurately.
- Electrical supply conductor requirements to maintain test integrity.
- Procedures for ensuring temperature equilibrium and lamp stabilization.
Definitions
The standard defines crucial terms such as:- Temperature rise (Δt): the increase in temperature of the test lampholder surface when mounted on the lamp’s cap.
- Equilibrium temperature (t_m): the stabilized temperature reached after sufficient lamp operating time.
Applications
IEC 60360 is essential for laboratories, manufacturers, and testing bodies involved in:
Lamp Safety Verification
Ensuring lamp caps do not exceed temperature limits, reducing risks such as burns or fires when installed in luminaires.Conformity Testing
Verifying lamps comply with regional and international safety standards, aiding global market acceptance.Product Development
Guiding designers to optimize lamp cap and base materials, improving thermal performance and expanding energy efficiency.Quality Control
Standardizing test routines that enhance reproducibility and reduce variability due to lamp or test environment differences.Lamp Compatibility Assessments
Assisting fixture manufacturers in evaluating how lamps perform when mounted, influencing luminaire design and materials.
Related Standards
Some relevant IEC documents that complement and support IEC 60360 include:
- IEC 60432 – Safety specifications for incandescent lamps, including temperature rise limits critical to IEC 60360 testing.
- IEC 60050 – International Electrotechnical Vocabulary, providing terminology related to electrotechnology used in IEC standards.
- IEC 60027, IEC 60417, IEC 60617 – Standards for graphical and letter symbols in electrical technology aiding documentation clarity.
Implementing the standardized method defined in IEC 60360:1998 ensures accurate measurement of lamp cap temperature rises, promoting product safety, regulatory compliance, and interoperability in the lighting industry worldwide. This standard remains a cornerstone for lamp testing protocols and continued innovation in lighting technology.
Relations
- Corrected By
IEC 60360:1998/COR1:1999 - Corrigendum 1 - Standard method of measurement of lamp cap temperature rise - Effective Date
- 05-Sep-2023
Get Certified
Connect with accredited certification bodies for this standard

IMQ S.p.A. (Certification)
Italian electrical product certification.

SLG Prüf- und Zertifizierungs GmbH
German testing and certification body.

UL Solutions
Global safety science company with testing, inspection and certification.
Sponsored listings
Frequently Asked Questions
IEC 60360:1998 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Standard method of measurement of lamp cap temperature rise". This standard covers: Describes the standard method of measurement of lamp cap temperature rise which is to be used when testing tungsten filament or discharge lamps for compliance with the limits. Covers the method of test and the specifications for test lampholders for lamps fitted with various sizes of ES and BC caps. This method has been used widely for incandescent lamps but its application is not limited to that type of lamp. The contents of the corrigendum of March 1999 have been included in this copy.
Describes the standard method of measurement of lamp cap temperature rise which is to be used when testing tungsten filament or discharge lamps for compliance with the limits. Covers the method of test and the specifications for test lampholders for lamps fitted with various sizes of ES and BC caps. This method has been used widely for incandescent lamps but its application is not limited to that type of lamp. The contents of the corrigendum of March 1999 have been included in this copy.
IEC 60360:1998 is classified under the following ICS (International Classification for Standards) categories: 29.140.10 - Lamp caps and holders. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 60360:1998 has the following relationships with other standards: It is inter standard links to IEC 60360:1998/COR1:1999. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
IEC 60360:1998 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
NORME
CEI
INTERNATIONALE
IEC
INTERNATIONAL
STANDARD
Troisième édition
Third edition
1998-06
Méthode normalisée de mesure de l’échauffement
d’un culot de lampe
Standard method of measurement
of lamp cap temperature rise
Numéro de référence
Reference number
CEI / IEC 60360:1998
Numéros des publications Numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. issued with a designation in the 60000 series.
Publications consolidées Consolidated publications
Les versions consolidées de certaines publications de Consolidated versions of some IEC publications
la CEI incorporant les amendements sont disponibles. including amendments are available. For example,
Par exemple, les numéros d’édition 1.0, 1.1 et 1.2 edition numbers 1.0, 1.1 and 1.2 refer, respectively, to
indiquent respectivement la publication de base, la the base publication, the base publication incor-
publication de base incorporant l’amendement 1, et porating amendment 1 and the base publication
la publication de base incorporant les amendements 1 incorporating amendments 1 and 2.
et 2.
Validité de la présente publication Validity of this publication
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept under
constamment revu par la CEI afin qu'il reflète l'état constant review by the IEC, thus ensuring that the
actuel de la technique. content reflects current technology.
Des renseignements relatifs à la date de re- Information relating to the date of the reconfirmation of
confirmation de la publication sont disponibles dans le the publication is available in the IEC catalogue.
Catalogue de la CEI.
Les renseignements relatifs à des questions à l’étude et Information on the subjects under consideration and
des travaux en cours entrepris par le comité technique work in progress undertaken by the technical
qui a établi cette publication, ainsi que la liste des committee which has prepared this publication, as well
publications établies, se trouvent dans les documents as the list of publications issued, is to be found at the
ci-dessous: following IEC sources:
• «Site web» de la CEI* • IEC web site*
• Catalogue des publications de la CEI • Catalogue of IEC publications
Publié annuellement et mis à jour régulièrement Published yearly with regular updates
(Catalogue en ligne)* (On-line catalogue)*
• Bulletin de la CEI • IEC Bulletin
Disponible à la fois au «site web» de la CEI* Available both at the IEC web site* and
et comme périodique imprimé as a printed periodical
Terminologie, symboles graphiques Terminology, graphical and letter
et littéraux symbols
En ce qui concerne la terminologie générale, le lecteur For general terminology, readers are referred to
se reportera à la CEI 60050: Vocabulaire Electro- IEC 60050: International Electrotechnical Vocabulary
technique International (VEI). (IEV).
Pour les symboles graphiques, les symboles littéraux For graphical symbols, and letter symbols and signs
et les signes d'usage général approuvés par la CEI, le approved by the IEC for general use, readers are
lecteur consultera la CEI 60027: Symboles littéraux à referred to publications IEC 60027: Letter symbols to
utiliser en électrotechnique, la CEI 60417: Symboles be used in electrical technology, IEC 60417: Graphical
graphiques utilisables sur le matériel. Index, relevé et symbols for use on equipment. Index, survey and
compilation des feuilles individuelles, et la CEI 60617: compilation of the single sheets and IEC 60617:
Symboles graphiques pour schémas. Graphical symbols for diagrams.
* Voir adresse «site web» sur la page de titre. * See web site address on title page.
NORME
CEI
INTERNATIONALE
IEC
INTERNATIONAL
Troisième édition
STANDARD
Third edition
1998-06
Méthode normalisée de mesure de l’échauffement
d’un culot de lampe
Standard method of measurement
of lamp cap temperature rise
IEC 1998 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun any form or by any means, electronic or mechanical,
procédé, électronique ou mécanique, y compris la photo- including photocopying and microfilm, without permission in
copie et les microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http: //www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
PRICE CODE Q
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 60360 © CEI:1998
SOMMAIRE
Pages
AVANT-PROPOS . 4
INTRODUCTION . 6
Articles
1 Généralités. 8
1.1 Domaine d’application. 8
1.2 Référence normative. 8
2 Définitions. 8
3 Conditions générales de mesure . 8
4 Prescriptions d’essai. 10
5 Douilles d’essai. 12
6 Conducteurs d’alimentation. 14
7 Thermocouple. 14
8 Assemblage de la lampe et de la douille d’essai dans l’enceinte . 16
9 Mesure de l’échauffement. 18
Figures . 20 à 34
60360 © IEC:1998 – 3 –
CONTENTS
Page
FOREWORD . 5
INTRODUCTION . 7
Clause
1 General. 9
1.1 Scope. 9
1.2 Normative reference. 9
2 Definitions. 9
3 General conditions for measurements . 9
4 Test requirements. 11
5 Test lampholders. 13
6 Supply conductors. 15
7 Thermocouple. 15
8 Assembly of the lamp and test lampholder in the enclosure . 17
9 Measurement of temperature rise. 19
Figures . 21-35
– 4 – 60360 © CEI:1998
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
___________
MÉTHODE NORMALISÉE DE MESURE DE L’ÉCHAUFFEMENT
D’UN CULOT DE LAMPE
AVANT-PROPOS
1) La CEI (Commission Electrotechnique Internationale) est une organisation mondiale de normalisation composée
de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes internationales.
Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national intéressé par le
sujet traité peut participer. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement avec l'Organisation
Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés
comme normes, rapports techniques ou guides et agréés comme tels par les Comités nationaux.
4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de
façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes
nationales et régionales. Toute divergence entre la norme de la CEI et la norme nationale ou régionale
correspondante doit être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité
n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes.
6) L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 60360 a été établie par le sous-comité 34A: Lampes, du comité
d’études 34 de la CEI: Lampes et équipements associés.
Cette troisième édition annule et remplace la deuxième édition parue en 1987, l’amendement 1
(1993) et l’amendement 2 (1996) et constitue une révision technique.
Le texte de la présente norme est issu de la deuxième édition, de l’amendement 1, de
l’amendement 2 et des documents suivants:
FDIS Rapport de vote
34A/814/FDIS 34A/828/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.
Dans la présente norme, les caractères d’imprimerie suivants sont utilisés:
– prescriptions proprement dites: caractères romains;
– modalités d’essais: caractères italiques;
– commentaires: petits caractères romains.
Le contenu du corrigendum de mars 1999 a été pris en considération dans cet exemplaire.
60360 © IEC:1998 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
___________
STANDARD METHOD OF MEASUREMENT
OF LAMP CAP TEMPERATURE RISE
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization
for Standardization (ISO) in accordance with conditions determined by agreement between the two
organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical reports or guides and they are accepted by the National Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60360 has been prepared by subcommittee 34A: Lamps, of IEC
technical committee 34: Lamps and related equipment.
This third edition cancels and replaces the second edition published in 1987, amendment 1
(1993) and amendment 2 (1996), and constitutes a technical revision.
The text of this standard is based on the second edition, amendments 1 and 2 and the
following documents:
FDIS Report on voting
34A/814/FDIS 34A/828/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
In this standard, the following print types are used:
– requirements proper: in roman type;
– test specifications: in italic type;
– explanatory matter: in smaller roman type.
The contents of the corrigendum of March 1999 have been included in this copy.
– 6 – 60360 © CEI:1998
INTRODUCTION
L’échauffement d’un culot de lampe dépend étroitement, en pratique, du montage de la lampe
et de l’état du culot. C’est pourquoi il a été nécessaire de définir une méthode de mesure
basée sur l’utilisation d’une douille d’essai normalisée. L’échauffement Δt mesuré sur la
s
douille d’essai normalisée est considéré, au regard de la présente norme, comme représentant
l’échauffement du culot de la lampe.
Comparée à la mesure de l’échauffement d’un culot de lampe nu, la mesure de l’échauffement
d’une douille d’essai normalisée présente les avantages suivants:
– une meilleure approximation des conditions réelles de fonctionnement;
– une reproductibilité améliorée par suite de la moindre influence du matériau constituant le
culot, de sa finition et de ses conditions de surface (lesquelles n’ont, en outre, que peu
d’influence sur les conditions réelles de fonctionnement);
– un nivellement (ou une moyenne) des températures des différentes parties du culot qui
donne une meilleure représentation du transfert de chaleur de la lampe au luminaire;
– une réduction des temps nécessaires aux mesures, étant donné que le thermocouple est
fixé une fois pour toutes sur la douille d’essai.
60360 © IEC:1998 – 7 –
INTRODUCTION
The temperature rise of the lamp cap is, in practice, very dependent on the mounting of the
lamp and the condition of the cap. For this reason, it has been necessary to define a method of
measurement based on the use of a standard test lampholder. The temperature rise Δt
s
measured on the standard test lampholder is taken as the lamp cap temperature rise for the
purpose of this standard.
Compared with the measurement of the temperature rise of the bare lamp cap, the measure-
ment of the temperature rise of a standard test lampholder has the following advantages:
– a better approximation to actual operating conditions;
– improved reproducibility, as there is less influence from lamp cap material, finish and
surface conditions (which also have little influence on actual operating conditions);
– levelling (or averaging) of the temperatures of various parts of the cap, giving a better
overall picture of the heat transferred from the lamp to the luminaire;
– reduced duration of measurements, as the thermocouple is fixed permanently to the test
lampholder.
– 8 – 60360 © CEI:1998
MÉTHODE NORMALISÉE DE MESURE DE L’ÉCHAUFFEMENT
D’UN CULOT DE LAMPE
1 Généralités
1.1 Domaine d’application
La présente Norme internationale décrit la méthode de mesure normalisée de l’échauffement
du culot de la lampe à appliquer pour la vérification de la conformité des lampes à
incandescence ou des lampes à décharge aux limites spécifiées. Les limites d’échauffement
relatives à des types particuliers de lampes sont, par exemple, celles dont la liste est donnée
dans la CEI 60432.
Cette norme décrit la méthode d’essai et fournit les spécifications des douilles d’essai à utiliser
avec les lampes selon le type de culot dont elles sont munies. Cette méthode a été largement
utilisée pour les lampes à incandescence, mais son application n’est pas limitée à cette
catégorie de lampes.
1.2 Référence normative
Le document normatif suivant contient des dispositions qui, par suite de la référence qui y est
faite, constituent des dispositions valables pour la présente Norme internationale. Au moment
de la publication, l'édition indiquée était en vigueur. Tout document est sujet à révision et les
parties prenantes aux accords fondés sur la présente Norme internationale sont invitées à
rechercher la possibilité d’appliquer l'édition la plus récente du document normatif indiqué ci-
après. Les membres de la CEI et de l’ISO possèdent le registre des Normes internationales en
vigueur.
CEI 60432: Prescriptions de sécurité pour lampes à incandescence
2 Définitions
Pour les besoins de la présente Norme internationale, les définitions suivantes s’appliquent:
2.1
échauffement de culot
échauffement de la surface d’une douille d’essai normalisée montée sur le culot de la lampe,
lorsque les mesures sont effectuées dans les conditions spécifiées dans la présente norme
2.2
température d’équilibre (t )
m
température stabilisée qu’une douille d’essai normalisée atteint après un temps d’allumage
suffisant de la lampe
NOTE – Il convient que la précision de mesure soit de ±1 °C.
3 Conditions générales de mesure
3.1 Vieillissement et stabilisation
Pour ces mesures, il n’est pas prévu de vieillissement préalable de la lampe. Une stabilité
suffisante de la lampe est obtenue à la fin de la durée nécessaire pour atteindre la température
d’équilibre dans l’enceinte d’essai.
60360 © IEC:1998 – 9 –
STANDARD METHOD OF MEASUREMENT
OF LAMP CAP TEMPERATURE RISE
1 General
1.1 Scope
This International Sandard describes the standard method of measurement of lamp cap
temperature rise which is to be used when testing incandescent or discharge lamps for
compliance with the limits. Temperature-rise limits for particular lamp types are, for example,
listed in IEC 60432.
It covers the method of test and the specifications for test lampholders for lamps fitted with
various sizes of Edison screw (ES) and Bayonet (BC) caps. This method has been used widely
for incandescent lamps but its application is not limited to that kind of lamp.
1.2 Normative reference
The following normative document contains provisions which, through reference in this text,
constitutes provisions of this International Standard. At the time of publication, the edition
indicated was valid. All normative documents are subject to revision, and parties to agreements
based on this International Standard are encouraged to investigate the possibility of applying
the most recent edition of the normative document indicated below. Members of IEC and ISO
maintain registers of currently valid International Standards.
IEC 60432: Safety specification for incandescent lamps
2 Definitions
For the purposes of this International Sandard, the following definitions apply:
2.1
temperature rise of cap
surface temperature rise of a standard test lampholder fitted to the lamp cap, when measured
under conditions specified in this standard
2.2
equilibrium temperature (t )
m
steady-state temperature of a standard test lampholder reached after a sufficient lamp
operating time
NOTE – The measuring accuracy should be ±1 °C.
3 General conditions for measurements
3.1 Ageing and stabilizing
For these measurements, no previous ageing of the lamp is required. Sufficient stability of the
lamp is achieved during the time necessary to reach the equilibrium temperature in the test
enclosure.
– 10 – 60360 © CEI:1998
3.2 Tension d’alimentation
a) Pour les lampes destinées à être connectées directement au réseau, les mesures doivent
être faites à la tension assignée, la tension d’alimentation étant maintenue constante à
±0,5 %.
b) Pour les lampes destinées à être connectées au réseau par l’intermédiaire d’un ballast, les
mesures doivent être faites à la tension assignée du ballast, la tension d’alimentation étant
maintenue constante à ±0,5 %. Les mesures doivent être effectuées en utilisant un ballast
de référence ou un ballast de production qui présente au courant d’étalonnage une
impédance écartée au plus de ±1 % de celle du ballast de référence.
Si la lampe est marquée avec une plage de tension la procédure d’essais de la CEI 60432 doit
s’appliquer, à moins qu’une procédure différente ne soit requise dans une autre publication.
3.3 Température ambiante et température de référence
Pour la définition de l’échauffement d’un culot, la température de référence est de 25 °C.
Toutefois, sauf prescription contraire dans la feuille de caractéristiques de la lampe
correspondante, il est possible d’effectuer les mesures à une température ambiante (t )
amb
comprise entre 15 °C et 40 °C; c’est-à-dire que la température dans l’enceinte d’essai, pendant
les mesures, doit rester à l’intérieur de cet intervalle pour que les résultats aient une
signification. L’enceinte d’essai spéciale décrite en 4.1 est conçue pour maintenir la
température ambiante à une valeur suffisamment constante.
Si la température dans l’enceinte d’essai diffère de 25 °C, la valeur Δt mesurée doit être
m
ramenée à celle qui serait obtenue dans une ambiance de 25 °C en appliquant la formule
suivante:
1/2
Δt
m
Δt = Δt + 1/3(t −25)
25 m amb
où
Δt est l'échauffement corrigé à la température de référence de 25 °C;
Δt est la différence entre la température d’équilibre finale et la température ambiante,
m
t – t ;
m amb
t est la température ambiante.
amb
NOTE – La formule ci-dessus est valable pour toute température ambiante comprise entre 15 °C et 40 °C.
4 Prescriptions d’essai
Les mesures de température doivent être effectuées dans une enceinte d’essai à l’abri des
courants d’air.
4.1 Enceinte
L’enceinte à l’abri des courants d’air est un parallélépipède rectangle dont le toit et au moins
trois des côtés sont à double paroi, la base étant pleine. Les doubles parois sont en métal
perforé et écartées de 150 mm environ. Les perforations, uniformément réparties, ont un
diamètre de 1 mm à 2 mm et occupent environ 40 % de la surface de chaque paroi.
Les surfaces internes sont enduites de peinture mate.
Les dimensions de l’enceinte doivent être telles que la température ambiante à l’intérieur de
celle-ci n’excède pas 40 °C durant l’exécution de l’essai. Pour satisfaire à cette condition, les
trois dimensions internes de l’enceinte doivent être, chacune, de préférence au moins égales à
900 mm. Il convient qu'un espace d’au moins 200 mm soit ménagé entre une partie
quelconque de la lampe et l’intérieur de l’enceinte. Des enceintes de construction différente
peuvent convenir s’il est établi qu’elles conduisent à des résultats d’essai similaires.
60360 © IEC:1998 – 11 –
3.2 Supply voltage
a) For lamps intended to be connected directly to the supply, measurement shall be made at
rated voltage, the supply voltage being maintained constant within ±0,5 %.
b) For lamps intended to be connected to the supply through a ballast, measurements shall be
made at the rated voltage of the ballast, the supply voltage being maintained constant
within ±0,5 %. Measurements shall be made using a reference ballast or a production
ballast which at the calibration current has an impedance within ±1 % of the reference
ballast.
If the lamp is marked with a voltage range the test procedure of IEC 60432 shall apply, unless
a different procedure is called for in another publication.
3.3 Ambient and reference temperatures
The reference temperature for defining cap temperature rise is 25 °C. However, it is possible
for the measurements to be made at an ambient temperature (t ) within the range of 15 °C to
amb
40 °C unless otherwise specified in the relevant lamp data sheet; that is, the temperature within
the test enclosure, during the measurement cycle, shall remain within this range for the results
to be meaningful. A special test enclosure, described in 4.1, is used to maintain the ambient
temperature at a sufficiently constant value.
If the temperature in the test enclosure differs from 25 °C, the value Δt measured shall be
m
converted to a temperature rise relevant to an ambient of 25 °C in accordance with the
following formula:
1/2
Δt
m
Δt = Δt + 1/3(t −25)
25 m amb
where
Δt is the temperature rise corrected to 25 °C;
Δt is the difference between the final equilibrium temperature and the ambient temperature,
m
t – t ;
m amb
t is the ambient temperature.
amb
NOTE – The above formula is valid for any ambient temperature between 15 °C and 40 °C.
4 Test requirements
Temperature measurements shall be made in a draught-free test enclosure.
4.1 Test enclosure
The draught-proof enclosure is rectangular, with a double skin on the top and on at least three
sides, and with a solid base. The double skins are of perforated metal, spaced apart
approximately 150 mm, with regular perforations of 1 mm to 2 mm diameter, occupying about
40 % of the whole area of each skin.
The internal surfaces are painted with a matt paint.
The dimensions of the enclosure shall be such that the ambient temperature within the test
enclosure will not exceed 40 °C while the test is being run. To achieve this condition, the three
principal internal dimensions shall be preferably at least 900 mm. There should be a clearance
of at least 200 mm between any part of the lamp and the inside of the enclosure. Alternative
constructions for draught-proof enclosures are suitable if it is established that similar test
results are obtained.
– 12 – 60360 © CEI:1998
NOTE – Pour le suivi de la production, on peut utiliser une enceinte plus petite, de dimensions 500 mm
× 500 mm × 500 mm, maintenant une température ambiante interne n’excédant pas 40 °C durant la mesure de
température, la lampe étant montée au centre de l’enceinte.
La température ambiante interne doit être mesurée au moyen d’un thermomètre protégé des
radiations directes provenant de la lampe en essai. Le thermomètre est à placer à hauteur de
la lampe, environ à mi-distance entre celle-ci et la paroi de l’enceinte.
4.2 Méthodes de suspension
A moins qu’une autre position d’allumage ne soit spécifiée pour la lampe d’essai, la position de
mesure normalisée est culot haut. Le dispositif de suspension de la lampe ne doit pas gêner la
convection naturelle de l’air autour de ce
...