IEC 60512-26-100:2008
(Main)Connectors for electronic equipment - Tests and measurements - Part 26-100: Measurement setup, test and reference arrangements and measurements for connectors according to IEC 60603-7 - Tests 26a to 26g
- Abstract
IEC 60512-26-100:2008 specifies the test and measurements and the related measurement setup and reference arrangements for interoperability and backward compatibility tests for the development and qualification of 8-way, free and fixed connectors for data transmission. The following test methods are provided:
- insertion loss, test 26a;
- return loss, test 26b;
- near-end crosstalk (NEXT), test 26c;
- far-end crosstalk (FEXT), test 26d;
- transfer impedance, test 26e;
- transverse conversion loss (TCL), test 26f;
- transverse conversion transfer loss (TCTL), test 26g.
This publication is to be read in conjunction with IEC 60512-1:2001 and IEC 60512-1-100:2006.
- Status
- Published
- Publication Date
- 24-May-2011
- Technical Committee
- SC 48B - Electrical connectors
- Drafting Committee
- PT 60512-26 - Measurements arrangements for part 23 and 25 test methods
- Current Stage
- PPUB - Publication issued - 60 Publication
- Start Date
- 21-Jul-2008
- Due Date
- 15-Aug-2008
- Completion Date
- 15-Aug-2008
Buy Documents
IEC 60512-26-100:2008+AMD1:2011 CSV - Connectors for electronic equipment - Tests and measurements - Part 26-100: Measurement setup, test and reference arrangements and measurements for connectors according to IEC 60603-7 - Tests 26a to 26g Released:5/25/2011
IEC 60512-26-100:2008 - Connectors for electronic equipment - Tests and measurements - Part 26-100: Measurement setup, test and reference arrangements and measurements for connectors according to IEC 60603-7 - Tests 26a to 26g Released:7/21/2008
Overview
IEC 60512-26-100:2008 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies detailed test procedures, measurement setups, and reference arrangements for 8-way connectors used in electronic equipment. Focused specifically on connectors conforming to IEC 60603-7, this standard provides a comprehensive methodology for verifying interoperability and backward compatibility of both free and fixed data transmission connectors.
The standard covers a series of critical tests-Tests 26a to 26g-evaluating electrical performance characteristics vital to ensuring reliable data communication. It complements foundational standards IEC 60512-1:2001 and IEC 60512-1-100:2006 to support consistent product development and qualification efforts within the electronics and telecommunications sectors.
Key Topics
IEC 60512-26-100 outlines seven primary test methods for connector evaluation, each designed to assess specific electrical parameters essential for high-quality data transmission:
Insertion Loss (Test 26a): Measures signal attenuation caused by the connector, critical for understanding overall signal integrity.
Return Loss (Test 26b): Assesses signal reflections due to impedance mismatches, impacting connector performance at high frequencies.
Near-End Crosstalk (NEXT, Test 26c): Evaluates interference between adjacent pairs at the transmitting end, important for minimizing signal degradation.
Far-End Crosstalk (FEXT, Test 26d): Quantifies crosstalk at the receiving end, influencing noise margins and error rates.
Transfer Impedance (Test 26e): Determines the connector's capability to shield against electromagnetic interference (EMI), thus ensuring electromagnetic compatibility (EMC).
Transverse Conversion Loss (TCL, Test 26f): Measures the loss when converting differential mode signals to common mode, affecting EMI behavior.
Transverse Conversion Transfer Loss (TCTL, Test 26g): Assesses the attenuation of noise converted from differential to common mode signals through the connector.
The standard also elaborates on technical requirements for the measurement setup, including instrumentation, calibration procedures, coaxial cable selection, balun specifications, and reference plane definitions. Detailed guidance on constructing and qualifying test plugs and reference plugs ensures accuracy and repeatability of measurements.
Applications
IEC 60512-26-100 serves as a critical reference for manufacturers, test laboratories, and quality assurance teams involved in the design, production, and validation of electronic connectors for data transmission. Key application areas include:
Connector Manufacturing: Provides test protocols for verifying connector electrical performance during R&D and manufacturing stages.
Quality Control: Enables consistent measurement of insertion loss, crosstalk, and impedance to ensure compliance with performance thresholds.
Product Development: Supports interoperability testing and backward compatibility assessments critical for connector upgrades and new product introductions.
Telecommunications Equipment: Ensures connectors meet stringent requirements for high-speed data transmission in network infrastructure.
Electromagnetic Compatibility Testing: Facilitates evaluation of connector shielding effectiveness to mitigate EMI risks.
Professionals leveraging this standard can improve connector reliability and enhance signal integrity in complex electronic systems where consistent data transmission quality is paramount.
Related Standards
For comprehensive understanding and application, IEC 60512-26-100 is intended to be used alongside the following key IEC standards:
IEC 60603-7: Defines the product specifications for the 8-way connectors that IEC 60512-26-100 addresses in testing and measurement.
IEC 60512-1:2001: Provides general test and measurement methods for connectors for electronic equipment, setting baseline requirements.
IEC 60512-1-100:2006: Offers additional general test procedures and reference setups supporting connector testing.
Other IEC 60512 Parts: Covers broader aspects of connector testing beyond electrical parameters, such as mechanical and environmental testing.
Adhering to these complementary standards ensures a thorough, standardized approach to connector evaluation within the electrical and electronic industries.
Keywords: IEC 60512-26-100, connector testing, insertion loss, return loss, crosstalk, transfer impedance, EMI, EMC, IEC 60603-7 connectors, electronic equipment connectors, data transmission connectors, test methods, electrical performance, interoperability tests, backward compatibility tests, IEC standards for connectors
Relations
- Effective Date
- 05-Sep-2023
Buy Documents
IEC 60512-26-100:2008+AMD1:2011 CSV - Connectors for electronic equipment - Tests and measurements - Part 26-100: Measurement setup, test and reference arrangements and measurements for connectors according to IEC 60603-7 - Tests 26a to 26g Released:5/25/2011
IEC 60512-26-100:2008 - Connectors for electronic equipment - Tests and measurements - Part 26-100: Measurement setup, test and reference arrangements and measurements for connectors according to IEC 60603-7 - Tests 26a to 26g Released:7/21/2008
Frequently Asked Questions
IEC 60512-26-100:2008 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Connectors for electronic equipment - Tests and measurements - Part 26-100: Measurement setup, test and reference arrangements and measurements for connectors according to IEC 60603-7 - Tests 26a to 26g". This standard covers: IEC 60512-26-100:2008 specifies the test and measurements and the related measurement setup and reference arrangements for interoperability and backward compatibility tests for the development and qualification of 8-way, free and fixed connectors for data transmission. The following test methods are provided: - insertion loss, test 26a; - return loss, test 26b; - near-end crosstalk (NEXT), test 26c; - far-end crosstalk (FEXT), test 26d; - transfer impedance, test 26e; - transverse conversion loss (TCL), test 26f; - transverse conversion transfer loss (TCTL), test 26g. This publication is to be read in conjunction with IEC 60512-1:2001 and IEC 60512-1-100:2006.
IEC 60512-26-100:2008 specifies the test and measurements and the related measurement setup and reference arrangements for interoperability and backward compatibility tests for the development and qualification of 8-way, free and fixed connectors for data transmission. The following test methods are provided: - insertion loss, test 26a; - return loss, test 26b; - near-end crosstalk (NEXT), test 26c; - far-end crosstalk (FEXT), test 26d; - transfer impedance, test 26e; - transverse conversion loss (TCL), test 26f; - transverse conversion transfer loss (TCTL), test 26g. This publication is to be read in conjunction with IEC 60512-1:2001 and IEC 60512-1-100:2006.
IEC 60512-26-100:2008 is classified under the following ICS (International Classification for Standards) categories: 31.220.10 - Plug-and-socket devices. Connectors. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 60512-26-100:2008 has the following relationships with other standards: It is inter standard links to IEC 60512-26-100:2008/AMD1:2011. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
IEC 60512-26-100:2008 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
IEC 60512-26-100 ®
Edition 1.1 2011-05
CONSOLIDATED VERSION
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Connectors for electronic equipment – Tests and measurements –
Part 26-100: Measurement setup, test and reference arrangements and
measurements for connectors according to IEC 60603-7 – Tests 26a to 26g
Connecteurs pour équipements électroniques – Essais et mesures –
Partie 26-100: Montage de mesure, dispositifs d’essai et de référence et mesures
pour les connecteurs conformes à la CEI 60603-7 – Essais 26a à 26g
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC
copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or
your local IEC member National Committee for further information.
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de l'IEC ou du Comité national de l'IEC du pays du demandeur. Si vous avez des
questions sur le copyright de l'IEC ou si vous désirez obtenir des droits supplémentaires sur cette publication, utilisez
les coordonnées ci-après ou contactez le Comité national de l'IEC de votre pays de résidence.
IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
IEC Catalogue - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
The stand-alone application for consulting the entire The world's leading online dictionary of electronic and
bibliographical information on IEC International Standards, electrical terms containing 20 000 terms and definitions in
Technical Specifications, Technical Reports and other English and French, with equivalent terms in 15 additional
documents. Available for PC, Mac OS, Android Tablets and languages. Also known as the International Electrotechnical
iPad. Vocabulary (IEV) online.
IEC publications search - www.iec.ch/searchpub IEC Glossary - std.iec.ch/glossary
The advanced search enables to find IEC publications by a 65 000 electrotechnical terminology entries in English and
variety of criteria (reference number, text, technical French extracted from the Terms and Definitions clause of
committee,…). It also gives information on projects, replaced IEC publications issued since 2002. Some entries have been
and withdrawn publications. collected from earlier publications of IEC TC 37, 77, 86 and
CISPR.
IEC Just Published - webstore.iec.ch/justpublished
Stay up to date on all new IEC publications. Just Published IEC Customer Service Centre - webstore.iec.ch/csc
details all new publications released. Available online and If you wish to give us your feedback on this publication or
also once a month by email. need further assistance, please contact the Customer Service
Centre: csc@iec.ch.
A propos de l'IEC
La Commission Electrotechnique Internationale (IEC) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications IEC
Le contenu technique des publications IEC est constamment revu. Veuillez vous assurer que vous possédez l’édition la
plus récente, un corrigendum ou amendement peut avoir été publié.
Catalogue IEC - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
Application autonome pour consulter tous les renseignements
Le premier dictionnaire en ligne de termes électroniques et
bibliographiques sur les Normes internationales,
électriques. Il contient 20 000 termes et définitions en anglais
Spécifications techniques, Rapports techniques et autres
et en français, ainsi que les termes équivalents dans 15
documents de l'IEC. Disponible pour PC, Mac OS, tablettes
langues additionnelles. Egalement appelé Vocabulaire
Android et iPad.
Electrotechnique International (IEV) en ligne.
Recherche de publications IEC - www.iec.ch/searchpub
Glossaire IEC - std.iec.ch/glossary
La recherche avancée permet de trouver des publications IEC
65 000 entrées terminologiques électrotechniques, en anglais
en utilisant différents critères (numéro de référence, texte,
et en français, extraites des articles Termes et Définitions des
comité d’études,…). Elle donne aussi des informations sur les
publications IEC parues depuis 2002. Plus certaines entrées
projets et les publications remplacées ou retirées.
antérieures extraites des publications des CE 37, 77, 86 et
CISPR de l'IEC.
IEC Just Published - webstore.iec.ch/justpublished
Restez informé sur les nouvelles publications IEC. Just Service Clients - webstore.iec.ch/csc
Published détaille les nouvelles publications parues. Si vous désirez nous donner des commentaires sur cette
Disponible en ligne et aussi une fois par mois par email. publication ou si vous avez des questions contactez-nous:
csc@iec.ch.
IEC 60512-26-100 ®
Edition 1.1 2011-05
CONSOLIDATED VERSION
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
colour
inside
Connectors for electronic equipment – Tests and measurements –
Part 26-100: Measurement setup, test and reference arrangements and
measurements for connectors according to IEC 60603-7 – Tests 26a to 26g
Connecteurs pour équipements électroniques – Essais et mesures –
Partie 26-100: Montage de mesure, dispositifs d’essai et de référence et
mesures pour les connecteurs conformes à la CEI 60603-7 – Essais 26a à 26g
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 13.220.10 ISBN 978-2-8891-2512-8
– 2 – 60512-26-100 IEC:2008+A1:2011
CONTENTS
FOREWORD . 6
INTRODUCTION . 8
1 Scope . 9
2 Normative reference . 9
3 General requirements for measurement setup . 10
3.1 Test instrumentation . 10
3.2 Coaxial cables and test leads for network analysers . 10
3.3 Measurement precautions . 10
3.4 Balun requirements . 11
3.5 Reference components for calibrations . 12
3.5.1 Reference loads for calibration . 12
3.5.2 Reference cables for calibration . 12
3.6 Termination loads for termination of conductor pairs . 12
3.7 Termination of screens . 13
3.8 Test specimen and reference planes . 13
3.9 Termination of balun with low return loss for common mode . 14
3.9.1 General . 14
3.9.2 Centre tap connected to ground . 14
3.9.3 Centre tap open . 14
4 Connector measurement up to 250 MHz . 15
4.1 Insertion loss (IL), Test 26a . 15
4.1.1 Object . 15
4.1.2 Free connector for insertion loss. 15
4.1.3 Test method . 15
4.1.4 Test set-up . 15
4.1.5 Procedure . 15
4.1.6 Test report . 17
4.1.7 Accuracy . 17
4.2 Return loss (RL), Test 26b . 17
4.2.1 Object . 17
4.2.2 Free connector for return loss . 17
4.2.3 Test method . 17
4.2.4 Test set-up . 17
4.2.5 Procedure . 17
4.2.6 Test report . 17
4.2.7 Accuracy . 17
4.3 Near-end crosstalk (NEXT), Test 26c . 18
4.3.1 Object . 18
4.3.2 Fixed and free connector combinations to be tested . 18
4.3.3 Test method . 18
4.3.4 Test set-up . 18
4.3.5 Procedure . 19
4.3.6 Test report . 20
4.3.7 Accuracy . 20
4.4 Far-end crosstalk (FEXT), Test 26d . 20
4.4.1 Object . 20
60512-26-100 IEC:2008+A1:2011 – 3 –
4.4.2 Fixed and free connector combinations to be tested . 20
4.4.3 Test method . 20
4.4.4 Test set-up . 20
4.4.5 Procedure . 21
4.4.6 Test report . 22
4.4.7 Accuracy . 22
4.5 Transfer impedance (Z ), Test 26e . 22
T
4.5.1 Object . 22
4.5.2 Test method . 22
4.5.3 Definitions . 22
4.5.4 Test set-up . 23
4.5.5 Procedure . 27
4.5.6 Test report . 29
4.5.7 Accuracy . 29
4.6 Transverse Conversion Loss (TCL), Test 26f . 29
4.6.1 Object . 29
4.6.2 Test method . 29
4.6.3 Test set-up . 29
4.6.4 Procedure . 30
4.6.5 Test report . 30
4.6.6 Accuracy . 30
4.7 Transverse Conversion Transfer Loss (TCTL), Test 26g . 31
4.7.1 Object . 31
4.7.2 Test method . 31
4.7.3 Test set-up . 31
4.7.4 Procedure . 31
4.7.5 Test report . 32
4.7.6 Accuracy . 32
5 Construction and qualification of test plugs . 32
5.1 De-embedding near-end crosstalk (NEXT) test plug . 32
5.1.1 Set-up and calibration of reference plug . 32
5.1.2 Test plug construction . 34
5.1.3 Test plug NEXT measurement . 34
5.1.4 Test plug NEXT requirements . 36
5.1.5 Test plug balance . 38
5.2 Far-end crosstalk (FEXT) test plug . 39
5.2.1 General . 39
5.2.2 Test plug FEXT measurement – de-embedding method . 40
5.2.3 Test plug FEXT measurement – direct method . 40
5.2.4 FEXT test plug requirements . 41
5.3 Return loss test plug . 41
6 Reference plug and jack construction and measurement – the basics of the de-
embedding test method . 41
6.1 De-embedding near-end crosstalk (NEXT) reference plug and jack . 41
6.1.1 Reference plug construction . 41
6.1.2 Return loss reference plug . 42
6.1.3 Set-up and calibration of reference plug . 43
6.1.4 De-embedding reference plug NEXT measurement. 43
6.1.5 Delay adjustment in lieu of port extension. 43
– 4 – 60512-26-100 IEC:2008+A1:2011
6.2 De-embedding near-end crosstalk (NEXT) reference jack . 43
6.2.1 Reference jack construction. 43
6.2.2 De-embedding reference jack NEXT measurement . 45
6.2.3 Differential mode jack vector . 45
6.3 Determining reference jack FEXT vector . 45
6.3.1 FEXT reference plug details . 45
6.3.2 FEXT reference jack assembly . 48
6.3.3 De-embedding reference jack FEXT assembly measurement . 49
Annex A (informative) Example test fixtures in support . 50
Bibliography . 56
Figure 1 – Optional 180° hybrid used instead of a balun . 11
Figure 2 – Example of calibration of reference loads . 12
Figure 3 – Resistor load . 13
Figure 4 – Definition of reference planes. 14
Figure 5 – Balanced attenuator for balun centre tap grounded . 14
Figure 6 – Balanced attenuator for balun centre tap open . 15
Figure 7 – Calibration . 16
Figure 8 – Measuring set-up . 16
Figure 9 – NEXT measurement for differential and common mode terminations . 19
Figure 10 – FEXT measurement for differential and common mode terminations . 21
Figure 11 – Preparation of test specimen . 23
Figure 12 – Triaxial test set-up . 24
Figure 13 – Impedance matching for R < 50 Ω . 26
Figure 14 – Impedance matching for R > 50 Ω . 27
Figure 15 – TCL measurement . 29
Figure 16 – TCTL measurement . 31
Figure 17 – Back-to-back through calibration (for more information see Annex A) . 33
Figure 18 – Mated test plug/direct fixture test configuration . 40
Figure 19 – De-embedding reference plug . 42
Figure 20 – De-embedding reference jack . 44
Figure 21 – De-embedding reference FEXT plug without sockets . 45
Figure 22 – De-embedding reference FEXT plug with sockets. 46
Figure 23 – Reference FEXT plug mated to PWB . 46
Figure 24 – Reference FEXT plug-test lead position . 47
Figure 25 – Reference FEXT plug assembly . 47
Figure 26 – Test leads connected to de-embedded reference jack/PWB assembly . 49
Figure 27 – Reference FEXT plug mated to reference jack/PWB assembly . 49
Figure A.1 – THI3KIT test head interface with baluns attached . 50
Figure A.2 – Alternative to item 3.1 in Table A.2 . 52
Figure A.3 – Pyramid test setup for shielded connectors . 52
Figure A.4 – Exploded assembly of the coaxial termination reference test head . 54
Figure A.5 – Detailed view of the coaxial termination reference test-head interface . 54
60512-26-100 IEC:2008+A1:2011 – 5 –
Table 1 – Test balun performance characteristics . 11
Table 2 – Uncertainty band of return loss measurement at frequencies below 100 MHz . 18
Table 3 – Uncertainty band of return loss measurement at frequencies above 100 MHz. 18
Table 4 – De-embedded NEXT real and imaginary reference jack vectors . 35
Table 5 – Differential mode reference jack vectors . 36
Table 6 – Test plug NEXT loss limits for connectors specified up to 100 MHz according
to IEC 60603-7-2 or IEC 60603-7-3 . 37
Table 7 – Test plug NEXT loss limits for connectors specified up to 250 MHz according
to IEC 60603-7-4 or IEC 60603-7-5 . 38
Table 8 – Test-plug differential and differential with common-mode consistency . 39
Table 9 – Test plug FEXT requirements – De-embedding method . 41
Table 10 – Return loss requirements for return loss reference plug . 43
Table A.1 – Coaxial termination reference head component list . 50
Table A.2 – Coaxial termination reference head, additional parts . 51
Table A.3 – Coaxial termination reference head component list . 53
– 6 – 60512-26-100 IEC:2008+A1:2011
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
CONNECTORS FOR ELECTRONIC EQUIPMENT –
TESTS AND MEASUREMENTS –
Part 26-100: Measurement setup, test and reference arrangements and
measurements for connectors according to IEC 60603-7 – Tests 26a to 26g
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
This consolidated version of the official IEC Standard and its amendment has been prepared
for user convenience.
IEC 60512-26-100 edition 1.1 contains the first edition (2008) [documents 48B/1892/FDIS and
48B/1925/RVD] and its amendment 1 (2011) [documents 48B/2065/FDIS and 48B/2149/RVD].
A vertical line in the margin shows where the base publication has been modified by
amendment 1. Additions and deletions are displayed in red, with deletions being struck
through.
60512-26-100 IEC:2008+A1:2011 – 7 –
International Standard IEC 60512-26-100 has been prepared by subcommittee 48B:
Connectors, of IEC technical committee 48: Electromechanical components and mechanical
structures for electronic equipment.
This standard is to be read in conjunction with IEC 60512-1 and IEC 60512-1-100 which
explains the structure of the IEC 60512 series.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of the IEC 60512 series, under the general title Connectors for electronic
equipment – Tests and measurements, can be found on the IEC website.
The committee has decided that the contents of the base publication and its amendments will
remain unchanged until the stability date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IMPORTANT – The “colour inside” logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct understanding
of its contents. Users should therefore print this publication using a colour printer.
– 8 – 60512-26-100 IEC:2008+A1:2011
INTRODUCTION
Detail specifications for 8-way, free and fixed connectors such as IEC 60603-7-4:2005 and
IEC 60603-7-5:2007 define measurement setup, test and reference arrangements and
measurements for interoperability and backward compatibility tests for connectors according
IEC 60603-7 up to 250 MHz for insertion loss (IL), near end crosstalk (NEXT), far end
crosstalk (FEXT), return loss (RL) and balance (transverse conversion loss, TCL, and
transverse conversion transfer loss, TCTL) as well as the de-embedding method to qualify the
fixed (outlet) connector.
This standard keeps the technical content of the test methods specified in the annexes C to J
as specified in IEC 60603-7-4:2005 and annexes C to K as specified in IEC 60603-7-5:2007,
but it structures and harmonizes the measurements for better readability. This standard is
intended to be referenced by the future second editions of IEC 60603-7-x and the future first
editions of IEC 60603-7-xy (under preparation). This standard is intended to be referenced by
IEC 60603-7-x Edition 2.0 and IEC 60603-7-xy Edition 1.0 standards (under preparation) and
may be referenced for all IEC standards with 60603-7 interface.
IEC 60516-26-100: Connectors for electronic equipment – Tests and measurements – Part
26-100, consists of the following clauses:
• Clause 3: General requirements for measurement setup
• Clause 4: Connector measurement up to 250 MHz
NOTE 1 Clauses 3 and 4 define the measurement procedures to qualify the outlet
• Clause 5: Construction and qualification of test plugs
NOTE 2 The wiring of the plug has an effect on the mated connector performance. Extensive measurements show
that NEXT and FEXT are affected in a particular way so that the properties of the test plug must be controlled. To
ensure adequate performance for the outlet over the expected range of different plug wiring, it shall be tested with
a set of up to 12 test plugs with different NEXT performances. The outlet complies with the NEXT requirements of
the standard only if all the combinations comply with their requirements for near end crosstalk. FEXT is handled in
a similar way, but only one test plug is required. Clause 5 describes the construction and qualification of test plugs.
Test plugs are used in the laboratory as long as possible to avoid the costly procedure to find new test plugs.
• Clause 6: Reference jack construction and measurement – the basics of the de-
embedding test method
NOTE 3 Clause 6 describes the preparation and measurements of the reference plugs and jacks as a basis of the
de-embedding test method.
The test methods provided here are:
• insertion loss, test 26a;
• return loss, test 26b;
• near-end crosstalk (NEXT), test 26c;
• far-end crosstalk (FEXT), test 26d;
• transfer impedance (Z ), test 26e;
T
• transverse conversion loss (TCL), test 26f;
• transverse conversion transfer loss (TCTL), test 26g.
For the coupling attenuation, see EN 50289-1-14.
60512-26-100 IEC:2008+A1:2011 – 9 –
CONNECTORS FOR ELECTRONIC EQUIPMENT –
TESTS AND MEASUREMENTS –
Part 26-100: Measurement setup, test and reference arrangements
and measurements for connectors according to IEC 60603-7 –
Tests 26a to 26g
1 Scope
This part of IEC 60512 specifies the test and measurements and the related measurement
setup and reference arrangements for interoperability and backward compatibility tests for the
development and qualification of 8-way, free and fixed connectors for data transmission.
2 Normative reference
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60169-15, Radio-frequency connectors – Part 15: R.F. coaxial connectors with inner
diameter of outer conductor 4.13 mm (0.163 in) with screw coupling – Characteristic
impedance 50 ohms (Type SMA)
IEC 60512-1, Connectors for electronic equipment – Tests and measurements – Part 1:
General
IEC 60512-1-100, Connectors for electronic equipment – Tests and measurements – Part 1-
100: General – Applicable publications
IEC 60603-7, Connectors for frequencies below 3 MHz for use with printed boards – Part 7:
Detail specification for connectors, 8-way, including fixed and free connectors with common
mating features, with assessed quality
IEC 60603-7-2, Connectors for electronic equipment – Part 7-2: Detail specification for 8-way,
unshielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHz
IEC 60603-7-3, Connectors for electronic equipment – Part 7-3: Detail specification for 8-way,
shielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHz
IEC 60603-7-4:2005, Connectors for electronic equipment – Part: 7-4: Detail specification for
8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to
250 MHz
IEC 60603-7-5:2007, Connectors for electronic equipment – Part: 7-5: Detail specification for
8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to
250 MHz
IEC 61156 (all parts), Multicore and symmetrical pair/quad cables for digital communications
IEC 61169-16, Radio-frequency connectors – Part 16: RF coaxial connectors with inner
diameter of outer conductor 7 mm (0,276 in) with screw coupling – Characteristic impedance
50 ohms (75 ohms) (Type N)
– 10 – 60512-26-100 IEC:2008+A1:2011
IS0 11801:2002, Information technology – Generic cabling for customer premises
ITU-T Recommendation G.117, Transmission aspects of unbalance about earth
ITU-T Recommendation O.9, Measuring arrangements to assess the degree of unbalance
about earth
EN 50289-1-14, Communication cables – Specification for test methods – Part 1-14: Electrical
test methods – Coupling attenuation or screening attenuation of connecting hardware
3 General requirements for measurement setup
3.1 Test instrumentation
These electrical test procedures require the use of a vector network analyser. The analyser
shall have be capabile of full 2-port calibrations. The analyser shall cover the frequency range
of 1 MHz to 1 GHz at least.
At least two test baluns are required in order to perform measurements with balanced
symmetrical signals. The requirements for the baluns are given in 3.4.
Reference loads and cables are needed for the calibration of the set-up. Requirements for the
reference loads and cables are given in 3.5.1 and 3.5.2 respectively.
Termination loads are needed for termination of pairs, used and unused, which are not
terminated by the test baluns. Requirements for the termination loads are given in 3.9.
An absorbing clamp and ferrite absorbers are needed for the coupling attenuation
measurements. The requirements for these items are given in EN 50289-1-14.
3.2 Coaxial cables and test leads for network analysers
Coaxial cable assemblies between network analyser and baluns should be as short as
possible. (It is recommended that they do not exceed 60 cm each.)
The baluns shall be electrically bonded to a common ground plane. For crosstalk
measurements, a test fixture may be used, in order to reduce residual crosstalk (see 3.9 and
Annex A).
Balanced test leads and associated connecting hardware to connect between the test
equipment and the connector under test shall be taken from components that meet or exceed
the requirements for the relevant class of balanced cabling performance according to
ISO/IEC 11801. Balanced test leads shall be limited to a maximum of 7 cm between each
balun and the reference plane of the connector under test. Pairs shall remain twisted from the
baluns to where connections are made. The impedance of the test leads from the DUT
(Device Under Test) to the baluns shall be managed, as far as possible, for both differential
and common modes. This can be done by mounting the test leads in a pyramid, channel, or
other device.
3.3 Measurement precautions
To assure a high degree of reliability for transmission measurements, the following
precautions are required.
a) Consistent and stable balun and resistor loads shall be used for each pair throughout the
test sequence.
60512-26-100 IEC:2008+A1:2011 – 11 –
b) Cable and adapter discontinuities, as introduced by physical flexing, sharp bends and
restraints shall be avoided before, during and after the tests.
c) Consistent test methodology and terminations (baluns or resistors) shall be used at all
stages of transmission performance qualifications.
The relative spacing of conductors in the pairs shall be preserved throughout the tests to
the greatest extent possible.
d) The balance of the cables is maintained to the greatest extent possible by consistent
conductor lengths and pair twisting to the point of load.
e) The sensitivity to set-up variations for these measurements at high frequencies demands
attention to detail for both the measurement equipment and the procedures.
f) All common mode terminations and the housing of the baluns shall be terminated to one
common ground plane.
3.4 Balun requirements
The baluns may be balun transformers or 180° hybrids with attenuators to improve matching if
needed (see Figure 1).
Attenuator
180° hybrid
Test port
To network analyzer
Attenuator
IEC 117/05
Figure 1 – Optional 180° hybrid used instead of a balun
The specifications for the baluns apply for the whole frequency range for which they are used.
Baluns shall be shielded and shall comply with the specifications listed in Table 1.
Table 1 – Test balun performance characteristics
Parameter Requirement at test frequencies
up to 250 MHz
Impedance, primary Matched to applied network analyser
Impedance, secondary 100 Ω
Insertion loss 10 dB maximum
Return loss secondary 14 dB minimum
a)
Return loss common mode with common mode termination 10 dB minimum
a)
Return loss common mode without common mode termination 1 dB maximum
b)
Longitudinal balance 50 dB
c)
Common mode rejection 50 dB
c)
Output signal balance 50 dB
Power rating 0,1 W
a)
Measured by connecting the balanced output terminals together and measuring the return loss. The nominal
primary impedance shall terminate the primary input terminal.
b)
Applicable for baluns, which are used for balance measurements. Measured from the primary input terminal to
the common mode terminal when the secondary balanced terminal is terminated with 100 Ω.
c)
Measured according to ITU-T Recommendations G.117 and O.9 (formerly CCITT recommendations).
– 12 – 60512-26-100 IEC:2008+A1:2011
3.5 Reference components for calibrations
3.5.1 Reference loads for calibration
To perform a one or two-port calibration of the test equipment, a short circuit, an open circuit
and a reference load are required. These devices shall be used to obtain a calibration at the
reference plane.
The reference load e.g. chip resistors shall be calibrated against a calibration reference,
which shall be a 50 Ω load, traceable to an international reference standard. Two 100 Ω
reference loads in parallel shall be calibrated against the calibration reference. The reference
loads for calibration shall be placed in an appropriate connector, e.g. N-type connector
according to IEC 61169-16 or SMA connector according to IEC 60169-15, meant for panel
mounting, which is machined flat on the back side (see Figure 2). The loads shall be fixed to
the flat side of the connector, distributed evenly around the centre conductor. A network
analyser shall be calibrated, 1-port full calibration, with the calibration reference. Thereafter,
the return loss of the reference loads for calibration shall be measured. The verified return
loss shall be >46 dB at frequencies up to 100 MHz and >40 dB at frequencies above 100 MHz
and up to the limit for which the measurements are to be carried out.
Machined flat
Loads for calibration
N type connector
IEC 118/05
Figure 2 – Example of calibration of reference loads
3.5.2 Reference cables for calibration
As a minimum, the reference cable that is used to perform the calibration of the test set-up
shall satisfy the requirement of the same class of balanced cabling performance according to
ISO/IEC 11801 according to the IEC 61156 series as the class of the connector. The
reference cable shall be a length of horizontal cable for which the sheath is preserved. One of
the pairs of the reference cable is used for the calibrations. The total length of the reference
cable shall be according to the length of the measurement cables as outlined in the calibration
procedures for the various tests. Both ends of the reference cable shall be well prepared, so
that the twisting is maintained up to the test ports.
3.6 Termination loads for termination of conductor pairs
During measurement, the conductor pairs of the measurement cables for the connector under
test shall be terminated according to the specified test set-up with impedance matching loads.
For the pairs under test, this is provided by the test instrumentation at one or both ends. For
pairs not under test or not connected to test instrumentation, resistor loads or terminated
baluns shall be applied. For differential mode only terminations, only resistor loads are
allowed.
The nominal differential mode impedance of the termination shall be 100 Ω. The nominal
common mode impedance shall be 50 Ω ± 25 Ω.
—————————
Unpredictable stray capacitances in baluns cause resonances at high frequencies, if they are used as
terminations, when the common-mode terminal is open.
60512-26-100 IEC:2008+A1:2011 – 13 –
NOTE The exact value of the common-mode impedance is not critical for most measurements. Normally, a value
of 75 Ω is used for unscreened connectors while a value of 25 Ω is used for screened connectors.
Resistor loads shall use resistors specified for ±1 % accuracy at d.c. and have a return loss
greater than 40 – 10log(f) where f is the frequency in megahertz . For pairs connected to a
balun, common-mode load is implemented by applying a load at the common-mode terminal
(centre tap) of the balu
...
IEC 60512-26-100
Edition 1.0 2008-07
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Connectors for electronic equipment – Tests and measurements –
Part 26-100: Measurement setup, test and reference arrangements and
measurements for connectors according to IEC 60603-7 – Tests 26a to 26g
Connecteurs pour équipements électroniques – Essais et mesures –
Partie 26-100: Montage de mesure, dispositifs d’essai et de référence et mesures
pour les connecteurs conformes à la CEI 60603-7 – Essais 26a à 26g
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.
IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
ƒ Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
ƒ Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
ƒ Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
ƒ Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 60512-26-100
Edition 1.0 2008-07
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Connectors for electronic equipment – Tests and measurements –
Part 26-100: Measurement setup, test and reference arrangements and
measurements for connectors according to IEC 60603-7 – Tests 26a to 26g
Connecteurs pour équipements électroniques – Essais et mesures –
Partie 26-100: Montage de mesure, dispositifs d’essai et de référence et
mesures pour les connecteurs conformes à la CEI 60603-7 – Essais 26a à 26g
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
XA
CODE PRIX
ICS 31.220.10 ISBN 2-8318-9892-7
– 2 – 60512-26-100 © IEC:2008
CONTENTS
FOREWORD.6
INTRODUCTION.8
1 Scope.9
2 Normative reference .9
3 General requirements for measurement setup .10
3.1 Test instrumentation.10
3.2 Coaxial cables and test leads for network analysers.10
3.3 Measurement precautions .10
3.4 Balun requirements .11
3.5 Reference components for calibrations.12
3.5.1 Reference loads for calibration .12
3.5.2 Reference cables for calibration .12
3.6 Termination loads for termination of conductor pairs .12
3.7 Termination of screens .13
3.8 Test specimen and reference planes .13
3.9 Termination of balun with low return loss for common mode .14
3.9.1 General .14
3.9.2 Centre tap connected to ground.14
3.9.3 Centre tap open.14
4 Connector measurement up to 250 MHz .15
4.1 Insertion loss (IL), Test 26a.15
4.1.1 Object .15
4.1.2 Free connector for insertion loss.15
4.1.3 Test method .15
4.1.4 Test set-up .15
4.1.5 Procedure.15
4.1.6 Test report.17
4.1.7 Accuracy .17
4.2 Return loss (RL), Test 26b .17
4.2.1 Object .17
4.2.2 Free connector for return loss.17
4.2.3 Test method .17
4.2.4 Test set-up .17
4.2.5 Procedure.17
4.2.6 Test report.17
4.2.7 Accuracy .17
4.3 Near-end crosstalk (NEXT), Test 26c .18
4.3.1 Object .18
4.3.2 Fixed and free connector combinations to be tested .18
4.3.3 Test method .18
4.3.4 Test set-up .18
4.3.5 Procedure.19
4.3.6 Test report.20
4.3.7 Accuracy .20
4.4 Far-end crosstalk (FEXT), Test 26d.20
4.4.1 Object .20
60512-26-100 © IEC:2008 – 3 –
4.4.2 Fixed and free connector combinations to be tested .20
4.4.3 Test method .20
4.4.4 Test set-up .20
4.4.5 Procedure.21
4.4.6 Test report.22
4.4.7 Accuracy .22
4.5 Transfer impedance (Z ), Test 26e .22
T
4.5.1 Object .22
4.5.2 Test method .22
4.5.3 Definitions .22
4.5.4 Test set-up .23
4.5.5 Procedure.26
4.5.6 Test report.27
4.5.7 Accuracy .27
4.6 Transverse Conversion Loss (TCL), Test 26f.28
4.6.1 Object .28
4.6.2 Test method .28
4.6.3 Test set-up .28
4.6.4 Procedure.28
4.6.5 Test report.29
4.6.6 Accuracy .29
4.7 Transverse Conversion Transfer Loss (TCTL), Test 26g.29
4.7.1 Object .29
4.7.2 Test method .29
4.7.3 Test set-up .30
4.7.4 Procedure.30
4.7.5 Test report.30
4.7.6 Accuracy .31
5 Construction and qualification of test plugs.31
5.1 De-embedding near-end crosstalk (NEXT) test plug .31
5.1.1 Set-up and calibration of reference plug .31
5.1.2 Test plug construction .32
5.1.3 Test plug NEXT measurement .33
5.1.4 Test plug NEXT requirements.34
5.1.5 Test plug balance .36
5.2 Far-end crosstalk (FEXT) test plug .37
5.2.1 General .37
5.2.2 Test plug FEXT measurement – de-embedding method .38
5.2.3 Test plug FEXT measurement – direct method .38
5.2.4 FEXT test plug requirements .39
5.3 Return loss test plug .39
6 Reference plug and jack construction and measurement – the basics of the de-
embedding test method .39
6.1 De-embedding near-end crosstalk (NEXT) reference plug and jack .39
6.1.1 Reference plug construction .39
6.1.2 Return loss reference plug.40
6.1.3 Set-up and calibration of reference plug .41
6.1.4 De-embedding reference plug NEXT measurement.41
6.1.5 Delay adjustment in lieu of port extension.41
– 4 – 60512-26-100 © IEC:2008
6.2 De-embedding near-end crosstalk (NEXT) reference jack.41
6.2.1 Reference jack construction.41
6.2.2 De-embedding reference jack NEXT measurement .43
6.2.3 Differential mode jack vector .43
6.3 Determining reference jack FEXT vector .43
6.3.1 FEXT reference plug details .43
6.3.2 FEXT reference jack assembly .46
6.3.3 De-embedding reference jack FEXT assembly measurement.47
Annex A (informative) Example test fixtures in support .48
Bibliography.54
Figure 1 – Optional 180° hybrid used instead of a balun .11
Figure 2 – Example of calibration of reference loads.12
Figure 3 – Resistor load.13
Figure 4 – Definition of reference planes.14
Figure 5 – Balanced attenuator for balun centre tap grounded .14
Figure 6 – Balanced attenuator for balun centre tap open .15
Figure 7 – Calibration .16
Figure 8 – Measuring set-up .16
Figure 9 – NEXT measurement for differential and common mode terminations .19
Figure 10 – FEXT measurement for differential and common mode terminations.21
Figure 11 – Preparation of test specimen.23
Figure 12 – Triaxial test set-up .24
Figure 13 – Impedance matching for R < 50 Ω .25
Figure 14 – Impedance matching for R > 50 Ω .26
Figure 15 – TCL measurement.28
Figure 16 – TCTL measurement.30
Figure 17 – Back-to-back through calibration (for more information see Annex A).31
Figure 18 – Mated test plug/direct fixture test configuration .38
Figure 19 – De-embedding reference plug .40
Figure 20 – De-embedding reference jack.42
Figure 21 – De-embedding reference FEXT plug without sockets.43
Figure 22 – De-embedding reference FEXT plug with sockets.44
Figure 23 – Reference FEXT plug mated to PWB.44
Figure 24 – Reference FEXT plug-test lead position .45
Figure 25 – Reference FEXT plug assembly .45
Figure 26 – Test leads connected to de-embedded reference jack/PWB assembly.47
Figure 27 – Reference FEXT plug mated to reference jack/PWB assembly .47
Figure A.1 – THI3KIT test head interface with baluns attached .48
Figure A.2 – Alternative to item 3.1 in Table A.2 .50
Figure A.3 – Pyramid test setup for shielded connectors.50
Figure A.4 – Exploded assembly of the coaxial termination reference test head.52
Figure A.5 – Detailed view of the coaxial termination reference test-head interface .52
60512-26-100 © IEC:2008 – 5 –
Table 1 – Test balun performance characteristics .11
Table 2 – Uncertainty band of return loss measurement at frequencies below 100 MHz.18
Table 3 – Uncertainty band of return loss measurement at frequencies above 100 MHz.18
Table 4 – De-embedded NEXT real and imaginary reference jack vectors.33
Table 5 – Differential mode reference jack vectors.34
Table 6 – Test plug NEXT loss limits for connectors specified up to 100 MHz according
to IEC 60603-7-2 or IEC 60603-7-3.35
Table 7 – Test plug NEXT loss limits for connectors specified up to 250 MHz according
to IEC 60603-7-4 or IEC 60603-7-5.36
Table 8 – Test-plug differential and differential with common-mode consistency .37
Table 9 – Test plug FEXT requirements – De-embedding method .39
Table 10 – Return loss requirements for return loss reference plug.41
Table A.1 – Coaxial termination reference head component list .48
Table A.2 – Coaxial termination reference head, additional parts .49
Table A.3 – Coaxial termination reference head component list .51
– 6 – 60512-26-100 © IEC:2008
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
CONNECTORS FOR ELECTRONIC EQUIPMENT –
TESTS AND MEASUREMENTS –
Part 26-100: Measurement setup, test and reference arrangements and
measurements for connectors according to IEC 60603-7 – Tests 26a to 26g
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60512-26-100 has been prepared by subcommittee 48B:
Connectors, of IEC technical committee 48: Electromechanical components and mechanical
structures for electronic equipment.
This standard cancels and replaces the Annexes of IEC 60603-7-x documents dealing with
transmission characteristics for interoperability and backward compatibility.
This standard is to be read in conjunction with IEC 60512-1 and IEC 60512-1-100 which
explains the structure of the IEC 60512 series.
60512-26-100 © IEC:2008 – 7 –
The text of this standard is based on the following documents:
FDIS Report on voting
48B/1892/FDIS 48B/1925/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts of the IEC 60512 series, under the general title Connectors for electronic
equipment – Tests and measurements, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
– 8 – 60512-26-100 © IEC:2008
INTRODUCTION
Detail specifications for 8-way, free and fixed connectors such as IEC 60603-7-4:2005 and
IEC 60603-7-5:2007 define measurement setup, test and reference arrangements and
measurements for interoperability and backward compatibility tests for connectors according
IEC 60603-7 up to 250 MHz for insertion loss (IL), near end crosstalk (NEXT), far end
crosstalk (FEXT), return loss (RL) and balance (transverse conversion loss, TCL, and
transverse conversion transfer loss, TCTL) as well as the de-embedding method to qualify the
fixed (outlet) connector.
This standard keeps the technical content of the test methods specified in the annexes C to J
as specified in IEC 60603-7-4:2005 and annexes C to K as specified in IEC 60603-7-5:2007,
but it structures and harmonizes the measurements for better readability. This standard is
intended to be referenced by the future second editions of IEC 60603-7-x and the future first
editions of IEC 60603-7-xy (under preparation). This standard is intended to be referenced by
IEC 60603-7-x Edition 2.0 and IEC 60603-7-xy Edition 1.0 standards (under preparation) and
may be referenced for all IEC standards with 60603-7 interface.
IEC 60516-26-100: Connectors for electronic equipment – Tests and measurements – Part
26-100, consists of the following clauses:
• Clause 3: General requirements for measurement setup
• Clause 4: Connector measurement up to 250 MHz
NOTE 1 Clauses 3 and 4 define the measurement procedures to qualify the outlet
• Clause 5: Construction and qualification of test plugs
NOTE 2 The wiring of the plug has an effect on the mated connector performance. Extensive measurements show
that NEXT and FEXT are affected in a particular way so that the properties of the test plug must be controlled. To
ensure adequate performance for the outlet over the expected range of different plug wiring, it shall be tested with
a set of up to 12 test plugs with different NEXT performances. The outlet complies with the NEXT requirements of
the standard only if all the combinations comply with their requirements for near end crosstalk. FEXT is handled in
a similar way, but only one test plug is required. Clause 5 describes the construction and qualification of test plugs.
Test plugs are used in the laboratory as long as possible to avoid the costly procedure to find new test plugs.
• Clause 6: Reference jack construction and measurement – the basics of the de-
embedding test method
NOTE 3 Clause 6 describes the preparation and measurements of the reference plugs and jacks as a basis of the
de-embedding test method.
The test methods provided here are:
• insertion loss, test 26a;
• return loss, test 26b;
• near-end crosstalk (NEXT), test 26c;
• far-end crosstalk (FEXT), test 26d;
• transfer impedance (Z ), test 26e;
T
• transverse conversion loss (TCL), test 26f;
• transverse conversion transfer loss (TCTL), test 26g.
For the coupling attenuation, see EN 50289-1-14.
60512-26-100 © IEC:2008 – 9 –
CONNECTORS FOR ELECTRONIC EQUIPMENT –
TESTS AND MEASUREMENTS –
Part 26-100: Measurement setup, test and reference arrangements
and measurements for connectors according to IEC 60603-7 –
Tests 26a to 26g
1 Scope
This part of IEC 60512 specifies the test and measurements and the related measurement
setup and reference arrangements for interoperability and backward compatibility tests for the
development and qualification of 8-way, free and fixed connectors for data transmission.
2 Normative reference
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60169-15, Radio-frequency connectors – Part 15: R.F. coaxial connectors with inner
diameter of outer conductor 4.13 mm (0.163 in) with screw coupling – Characteristic
impedance 50 ohms (Type SMA)
IEC 60512-1, Connectors for electronic equipment – Tests and measurements – Part 1:
General
IEC 60512-1-100, Connectors for electronic equipment – Tests and measurements – Part 1-
100: General – Applicable publications
IEC 60603-7, Connectors for frequencies below 3 MHz for use with printed boards – Part 7:
Detail specification for connectors, 8-way, including fixed and free connectors with common
mating features, with assessed quality
IEC 60603-7-2, Connectors for electronic equipment – Part 7-2: Detail specification for 8-way,
unshielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHz
IEC 60603-7-3, Connectors for electronic equipment – Part 7-3: Detail specification for 8-way,
shielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHz
IEC 60603-7-4:2005, Connectors for electronic equipment – Part: 7-4: Detail specification for
8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to
250 MHz
IEC 60603-7-5:2007, Connectors for electronic equipment – Part: 7-5: Detail specification for
8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to
250 MHz
IEC 61156 (all parts), Multicore and symmetrical pair/quad cables for digital communications
IEC 61169-16, Radio-frequency connectors – Part 16: RF coaxial connectors with inner
diameter of outer conductor 7 mm (0,276 in) with screw coupling – Characteristic impedance
50 ohms (75 ohms) (Type N)
– 10 – 60512-26-100 © IEC:2008
IS0 11801:2002, Information technology – Generic cabling for customer premises
ITU-T Recommendation G.117, Transmission aspects of unbalance about earth
ITU-T Recommendation O.9, Measuring arrangements to assess the degree of unbalance
about earth
EN 50289-1-14, Communication cables – Specification for test methods – Part 1-14: Electrical
test methods – Coupling attenuation or screening attenuation of connecting hardware
3 General requirements for measurement setup
3.1 Test instrumentation
These electrical test procedures require the use of a vector network analyser. The analyser
shall have be capabile of full 2-port calibrations. The analyser shall cover the frequency range
of 1 MHz to 1 GHz at least.
At least two test baluns are required in order to perform measurements with balanced
symmetrical signals. The requirements for the baluns are given in 3.4.
Reference loads and cables are needed for the calibration of the set-up. Requirements for the
reference loads and cables are given in 3.5.1 and 3.5.2 respectively.
Termination loads are needed for termination of pairs, used and unused, which are not
terminated by the test baluns. Requirements for the termination loads are given in 3.9.
An absorbing clamp and ferrite absorbers are needed for the coupling attenuation
measurements. The requirements for these items are given in EN 50289-1-14.
3.2 Coaxial cables and test leads for network analysers
Coaxial cable assemblies between network analyser and baluns should be as short as
possible. (It is recommended that they do not exceed 60 cm each.)
The baluns shall be electrically bonded to a common ground plane. For crosstalk
measurements, a test fixture may be used, in order to reduce residual crosstalk (see 3.9 and
Annex A).
Balanced test leads and associated connecting hardware to connect between the test
equipment and the connector under test shall be taken from components that meet or exceed
the requirements for the relevant class of balanced cabling performance according to
ISO/IEC 11801. Balanced test leads shall be limited to a maximum of 7 cm between each
balun and the reference plane of the connector under test. Pairs shall remain twisted from the
baluns to where connections are made. The impedance of the test leads from the DUT
(Device Under Test) to the baluns shall be managed, as far as possible, for both differential
and common modes. This can be done by mounting the test leads in a pyramid, channel, or
other device.
3.3 Measurement precautions
To assure a high degree of reliability for transmission measurements, the following
precautions are required.
a) Consistent and stable balun and resistor loads shall be used for each pair throughout the
test sequence.
60512-26-100 © IEC:2008 – 11 –
b) Cable and adapter discontinuities, as introduced by physical flexing, sharp bends and
restraints shall be avoided before, during and after the tests.
c) Consistent test methodology and terminations (baluns or resistors) shall be used at all
stages of transmission performance qualifications.
The relative spacing of conductors in the pairs shall be preserved throughout the tests to
the greatest extent possible.
d) The balance of the cables is maintained to the greatest extent possible by consistent
conductor lengths and pair twisting to the point of load.
e) The sensitivity to set-up variations for these measurements at high frequencies demands
attention to detail for both the measurement equipment and the procedures.
f) All common mode terminations and the housing of the baluns shall be terminated to one
common ground plane.
3.4 Balun requirements
The baluns may be balun transformers or 180° hybrids with attenuators to improve matching if
needed (see Figure 1).
Attenuator
180° hybrid
Test port
To network analyzer
Attenuator
IEC 117/05
Figure 1 – Optional 180° hybrid used instead of a balun
The specifications for the baluns apply for the whole frequency range for which they are used.
Baluns shall be shielded and shall comply with the specifications listed in Table 1.
Table 1 – Test balun performance characteristics
Parameter Requirement at test frequencies
up to 250 MHz
Impedance, primary Matched to applied network analyser
Impedance, secondary
100 Ω
Insertion loss 10 dB maximum
Return loss secondary 14 dB minimum
a)
Return loss common mode with common mode termination 10 dB minimum
a)
Return loss common mode without common mode termination 1 dB maximum
b)
Longitudinal balance 50 dB
c)
Common mode rejection 50 dB
c)
Output signal balance 50 dB
Power rating 0,1 W
a)
Measured by connecting the balanced output terminals together and measuring the return loss. The nominal
primary impedance shall terminate the primary input terminal.
b)
Applicable for baluns, which are used for balance measurements. Measured from the primary input terminal to
the common mode terminal when the secondary balanced terminal is terminated with 100 Ω.
c)
Measured according to ITU-T Recommendations G.117 and O.9 (formerly CCITT recommendations).
– 12 – 60512-26-100 © IEC:2008
3.5 Reference components for calibrations
3.5.1 Reference loads for calibration
To perform a one or two-port calibration of the test equipment, a short circuit, an open circuit
and a reference load are required. These devices shall be used to obtain a calibration at the
reference plane.
The reference load e.g. chip resistors shall be calibrated against a calibration reference,
which shall be a 50 Ω load, traceable to an international reference standard. Two 100 Ω
reference loads in parallel shall be calibrated against the calibration reference. The reference
loads for calibration shall be placed in an appropriate connector, e.g. N-type connector
according to IEC 61169-16 or SMA connector according to IEC 60169-15, meant for panel
mounting, which is machined flat on the back side (see Figure 2). The loads shall be fixed to
the flat side of the connector, distributed evenly around the centre conductor. A network
analyser shall be calibrated, 1-port full calibration, with the calibration reference. Thereafter,
the return loss of the reference loads for calibration shall be measured. The verified return
loss shall be >46 dB at frequencies up to 100 MHz and >40 dB at frequencies above 100 MHz
and up to the limit for which the measurements are to be carried out.
Machined flat
Loads for calibration
N type connector
IEC 118/05
Figure 2 – Example of calibration of reference loads
3.5.2 Reference cables for calibration
As a minimum, the reference cable that is used to perform the calibration of the test set-up
shall satisfy the requirement of the same class of balanced cabling performance according to
ISO/IEC 11801 according to the IEC 61156 series as the class of the connector. The
reference cable shall be a length of horizontal cable for which the sheath is preserved. One of
the pairs of the reference cable is used for the calibrations. The total length of the reference
cable shall be according to the length of the measurement cables as outlined in the calibration
procedures for the various tests. Both ends of the reference cable shall be well prepared, so
that the twisting is maintained up to the test ports.
3.6 Termination loads for termination of conductor pairs
During measurement, the conductor pairs of the measurement cables for the connector under
test shall be terminated according to the specified test set-up with impedance matching loads.
For the pairs under test, this is provided by the test instrumentation at one or both ends. For
pairs not under test or not connected to test instrumentation, resistor loads or terminated
baluns shall be applied. For differential mode only terminations, only resistor loads are
allowed.
The nominal differential mode impedance of the termination shall be 100 Ω. The nominal
common mode impedance shall be 50 Ω ± 25 Ω.
—————————
Unpredictable stray capacitances in baluns cause resonances at high frequencies, if they are used as
terminations, when the common-mode terminal is open.
60512-26-100 © IEC:2008 – 13 –
NOTE The exact value of the common-mode impedance is not critical for most measurements. Normally, a value
of 75 Ω is used for unscreened connectors while a value of 25 Ω is used for screened connectors.
Resistor loads shall use resistors specified for ±1 % accuracy at d.c. and have a return loss
greater than 40 – 10log(f) where f is the frequency in megahertz . For pairs connected to a
balun, common-mode load is implemented by applying a load at the common-mode terminal
(centre tap) of the balun. The impedance of the load is equal to the common-mode
impedance. For a balun without a common-mode terminal (centre tap is not accessible), the
requirement for common-mode return loss shall be complied with by inserting a balanced
attenuator between the balun and the connector pair. Guidance on how this is done is shown
in 3.9. For pairs connected to resistor loads, common-mode load is implemented by the Y
configuration shown in Figure 3.
R
R
R
IEC 119/05
Figure 3 – Resistor load
R
dif
where: R = (1)
R
dif
R = R −
and (2)
2 com
where:
R is the differential mode impedance (Ω);
dif
R is the common mode impedance (Ω).
com
The two resistors R shall be matched to within 0,5 %. The termination shall be implemented
at a small printed circuit board with surface mount resistors. The layout for the resistors R
shall be symmetrical.
The commonmode termination points for all pairs shall be connected to the ground plane.
3.7 Termination of screens
If the connector under test is screened, screened measurement cables shall be applied.
(Individually screened twisted pairs (STP) are recommended.)
The screen or screens of these cables shall be fixed to the ground plane as close as possible
to the measurement baluns.
If a pyramid test setup is used, the screen of each pair shall in contact with the grooves of the
pyramid and connected as close as possible to the baluns on the mounting plate.
Care shall be taken to maintain a tight fit of the individual pair foil, if present, around the
twisted pairs.
3.8 Test specimen and reference planes
The test specimen is a mated pair of relevant connectors. The electrical reference plane for
the test specimen is the point at which the cable sheath enters the connector (the back end of
the connector) or the point at which the internal geometry of the cable is no longer
—————————
Return loss of terminations are measured with a network analyser connected to one balun, which is calibrated
(full 1-port calibration) using the r
...