Corrigendum 2 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-50: Examinations and measurements - Crosstalk for optical spatial switches

Corrigendum 2 - Dispositifs d'interconnexion et composants passifs à fibres optiques - Procédures fondamentales d'essais et de mesures - Partie 3-50: Examens et mesures - Diaphonie relative aux commutateurs spatiaux optiques

General Information

Status
Published
Publication Date
27-Jul-2015
Current Stage
PPUB - Publication issued
Start Date
15-Aug-2015
Completion Date
28-Jul-2015
Ref Project

Relations

Buy Standard

Standard
IEC 61300-3-50:2013/COR2:2015 - Corrigendum 2 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-50: Examinations and measurements - Crosstalk for optical spatial switches Released:7/28/2015
English and French language
10 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


 IEC 2015
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
IEC 61300-3-50 IEC 61300-3-50
Edition 1.0  2013-05 Édition 1.0  2013-05

FIBRE OPTIC INTERCONNECTING DEVICES AND DISPOSITIFS D'INTERCONNEXION ET
PASSIVE COMPONENTS – COMPOSANTS PASSIFS A FIBRES OPTIQUES –
BASIC TEST AND MEASUREMENT PROCEDURES FONDAMENTALES D'ESSAIS ET
PROCEDURES – DE MESURES –
Part 3-50: Examinations and measurements – Partie 3-50: Examens et mesures – Diaphonie
Crosstalk for optical spatial switches relative aux commutateurs spatiaux optiques

CORRIGENDUM 2
Corrections to the French version appear after the English text.
Les corrections à la version française sont données après le texte anglais.
5.6 Measurement for other input ports
Replace the existing text with the following new text
Change the connection of light source S to another input port Ij (j = 2 to M). Repeat the
procedure of 5.2 to 5.5.
6.1 Calculation of crosstalk for specified port pairs
Replace the existing second paragraph with the following new paragraph
This crosstalk is the crosstalk of signal light 1 with signal light 2 as noise for signal light 1 for
output port O1, when this DUT is used for M x N (M input ports and N output ports),
connected port I1 to port O1 and input signal light 1 from port O1, signal light 2 from port O2.
6.2 Calculation of total crosstalk for a specified output port
Replace the existing Equation (5) with the following new Equation (5)
 
i=N
P
i
 
XT (O )= 10log 10 − P
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.