Corrigendum 1 - Cable networks for television signals, sound signals and interactive services - Part 11: Safety

Corrigendum 1 - Réseaux de distribution par câbles pour signaux de télévision, signaux de radiodiffusion sonore et services interactifs - Partie 11: Sécurité

General Information

Status
Published
Publication Date
11-Jul-2016
Current Stage
DELPUB - Deleted Publication
Completion Date
15-Feb-2023
Ref Project

Relations

Buy Standard

Standard
IEC 60728-11:2016/COR1:2016 - Corrigendum 1 - Cable networks for television signals, sound signals and interactive services - Part 11: Safety Released:7/12/2016
English and French language
10 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


 IEC 2016
INTERNATIONAL ELECTROTECHNICAL COMMISSION

COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE

____________
IEC 60728-11 IEC 60728-11
Edition 4.0  2016-03 Édition 4.0  2016-03

Cable networks for television signals, sound Réseaux de distribution par câbles pour signaux
signals and interactive services – de télévision, signaux de radiodiffusion sonore
et services interactifs –
Part 11: Safety
Partie 11: Sécurité
CO RRI G ENDU M 1
Figure 10 – Flow chart for selection of Figure 10 – Organigramme pour le choix
the appropriate method for protecting de la méthode appropriée pour protéger
the antenna system against le système d'antennes contre les
atmospheric overvoltages surtensions atmosphériques
In the flow chart of this figure replace the Dans l'organigramme de cette figure
reference to Figure 8 by Figure 9. remplacer la référence à la Figure 8 par la
Figure 9.
See new Figure 10 below. Voir la nouvelle Figure 10 ci-dessous.
A.4 Temporary safety measures A.4 Mesures de sécurité temporaires
Insert, after the 3 bullets of item a), item b) Cette correction s'applique à la version
before the paragraph and indent as anglaise seulement.

follows:
b) The touch current hazard (safe let-go

threshold current) defined in IEC 60990
is the level ….
IEC 60728-11:2016-03/COR1:2016-06(en-fr)

– 2 – IEC 60728-11:2016/COR1:2016

 IEC 2016
Request for installation of Single dwelling installation
Yes
an antenna system acc. to 11.1 (no LPS
available)?
No
Installation in protected
Yes
area of the building acc.
Figure 9 possible?
No
For single dwelling
Yes
unit only ?
No LPS available?
Installation of antenna
Output 2 / No
system without earthing and
Solution 2
without equipotential
bonding acc. to 11.1
Yes
Assessment of lightning
a
stroke
Installation of antenna
Output 4 /
system with earthing and
Solution 4
Installation in
with equipotential bonding
protected volume of Yes
acc. to 11.2.3
LPS possible?
Installation of antenna
system without earthing but Output 1 /
Risk tolerable? YES
with equipotential bonding Solution 1
Not known
acc. to 11.2.3
Not known
No
Apply
appropriate
Legend: No
provisions
LPS  Lightning Protection System
Provisions
LSR  Lightning Stroke Risk
Prot. volume
applicable for
ATS  Air Termination System
Installation of an external,
Yes
possible by an
R < RT ? Yes
isolated ATS
external, isolated
ATS?
No
Responsibility of the
antenna installer Conclusion:
No
Installation of an LPS
required
Extension of antenna mast
Installation of antenna system
(as ATS) and connection Output 3 /
with equipotential bonding
Responsibility of the
with existing LPS acc. to Solution 3
acc. to 11.2.2
LPS-installer Installation of an LPS for the
IEC 62305-3
building
IEC
 IEC 2016
a
An assessment should be made of the risk o
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.