Industrial communication networks - Profiles - Part 5-3: Installation of fieldbuses - Installation profiles for CPF 3

IEC 61784-5-3:2010(E) specifies the installation profiles for CPF 3 (PROFIBUS/PROFINET). The installation profiles are specified in the annexes. These annexes are read in conjunction with IEC 61918:2010. This second edition cancels and replaces the first edition published in 2007. This edition constitutes a technical revision. It includes the technical changes of the corrigendum for the first edition in 2008 and an addition concerning transmission performance measurement (see Annex C.6.3.2.1.2).
This publication is to be read in conjunction with IEC 61918:2010.

General Information

Status
Published
Publication Date
21-Jul-2010
Technical Committee
Current Stage
DELPUB - Deleted Publication
Completion Date
13-Sep-2013
Ref Project

Relations

Buy Standard

Standard
IEC 61784-5-3:2010 - Industrial communication networks - Profiles - Part 5-3: Installation of fieldbuses - Installation profiles for CPF 3 Released:7/22/2010 Isbn:9782889120567
English language
103 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


IEC 61784-5-3 ®
Edition 2.0 2010-07
INTERNATIONAL
STANDARD
colour
inside
Industrial communication networks – Profiles –
Part 5-3: Installation of fieldbuses – Installation profiles for CPF 3

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.

IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 61784-5-3 ®
Edition 2.0 2010-07
INTERNATIONAL
STANDARD
colour
inside
Industrial communication networks – Profiles –
Part 5-3: Installation of fieldbuses – Installation profiles for CPF 3

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
XD
ICS 25.040.40; 35.100.40 ISBN 978-2-88912-056-7
– 2 – 61784-5-3 © IEC:2010(E)
CONTENTS
FOREWORD.5
INTRODUCTION.7
1 Scope.8
2 Normative references .8
3 Terms, definitions and abbreviated terms .8
4 CPF 3: Overview of installation profiles .8
5 Installation profile conventions .9
6 Conformance to installation profiles.9
Annex A (normative) CP 3/1 (PROFIBUS) specific installation profile.11
Annex B (normative)  CP 3/2 (PROFIBUS) specific installation profile.43
Annex C (normative) CP 3/3, CP 3/4, CP 3/5, CP 3/6 (PROFINET) specific installation
profile .77
Bibliography.103

Figure 1 – Standards relationships.7
Figure A.1 – Recommended combination of shielding and earthing for CP 3/1
networks with RS 485-IS.24
Figure A.2 – Sub-D connector pin numberings (front view).29
Figure A.3 – 5-pin M-12 female socket.30
Figure A.4 – 5 pins M-12 male plug for CP 3/1.31
Figure A.5 – Test circuit A - resistance measurement of data line B and shield.36
Figure A.6 – Test circuit B - resistance measurement of data line A and shield.37
Figure A.7 – Test circuit C - resistance measurement of data line A, data line B, and
shield.37
Figure A.8 – Test circuit D - resistance measurement between data line A and B .38
Figure A.9 – Resistance measurement without 9-pin Sub-D plug .38
Figure A.10 – Loop core resistance (cable type A) .39
Figure A.11 – Action and resolution tree for measurement 1 (RS 485 and RS 485-IS) .40
Figure A.12 – Action and resolution tree for measurement 2 (RS 485 and RS 485-IS) .41
Figure A.13 – Action and resolution tree for measurement 3 (RS 485 and RS 485-IS) .41
Figure B.1 – Connection of CP 3/1 networks.46
Figure B.2 – Typical fieldbus architecture .48
Figure B.3 – Fieldbus with stations supplied by auxiliary power sources .49
Figure B.4 – Fieldbus model .51
Figure B.5 – Current modulation (Manchester II code) .52
Figure B.6 – Tree topology .53
Figure B.7 – Bus topology.54
Figure B.8 – Combination of the tree topology and the bus topology .54
Figure B.9 – Fieldbus extension.55
Figure B.10 – Recommended combination of shielding and earthing.67
Figure B.11 – Ideal combination of shielding and earthing .69
Figure B.12 – Capacitive earthing .70
Figure B.13 – Galvanic isolated field device.71

61784-5-3 © IEC:2010(E) – 3 –
Figure B.14 – Pin assignment of the male and female connectors IEC 60947-5-2 (A-
coding) .74
Figure C.1 – End-to-end link without interconnections.90
Figure C.2 – Assembled end-to-end link .90
Figure C.3 – Connectionless optical fibre link .91
Figure C.4 – Assembled optical fibre link .91
Figure C.5 – Shielded connectors for CP 3/3, CP 3/4, CP 3/5 and CP 3/6 fieldbus
networks .97
Figure C.6 – Pin-assignment for a straight cable.97

Table A.1 – Excerpt of MICE definition.13
Table A.2 – Basic network characteristics for balanced cabling not based on Ethernet
(ISO/IEC 8802-3) .15
Table A.3 – Network characteristics for optical fibre cabling.15
Table A.4 – Information relevant to copper cable: fixed cables.17
Table A.5 – Information relevant to optical fibre cables .18
Table A.6 – Connectors for copper cabling CPs not based on Ethernet.19
Table A.7 – Optical fibre connecting hardware .19
Table A.8 – Relationship between FOC and fibre types (CP 3/1).20
Table A.9 – Parameters for balanced cables.26
Table A.10 – Parameters for silica optical fibre cables .27
Table A.11 – Parameters for POF optical fibre cables .27
Table A.12 – Parameters for hard clad silica optical fibre cables.27
Table A.13 – Use of 9 pin Sub-D connector pins (RS 485) .29
Table A.14 – Use of 9 pin Sub-D connector pins (RS 485-IS).30
Table A.15 – Use of M12 connector pins (RS 485).31
Table A.16 – Use of M12 connector pins (RS 485-IS) .32
Table A.17 – Maximum fibre channel attenuation for CP 3/1 (PROFIBUS) .42
Table B.1 – Valid parameter range of the FISCO model for use as EEx ib IIC / IIB.50
Table B.2 – Valid parameter range of the FISCO model for use as EEx ia IIC .50
Table B.3 – Power supply (operational values) .56
Table B.4 – Line lengths which can be achieved .56
Table B.5 – Limit values for distortion, reflection and signal delay.57
Table B.6 – Recommended maximum cable lengths including spurs .57
Table B.7 – Recommended length of the spurs .57
Table B.8 – Maximum length of the splices .58
Table B.9 – Information relevant to copper cable: fixed cables.59
Table B.10 – Safety limit values for the fieldbus cable .60
Table B.11 – Connectors for copper cabling CPs not based on Ethernet.61
Table B.12 – Mixing devices from different categories .63
Table B.13 – Electrical characteristics of fieldbus interfaces .64
Table B.14 – Recommended data sheet specifications for CP 3/2 devices .65
Table B.15 – Parameters for balanced cables .73
Table B.16 – Contact assignments for the external connector for harsh industrial
environments .74

– 4 – 61784-5-3 © IEC:2010(E)
Table C.1 – General transmission media selection information .79
Table C.2 – Network characteristics for balanced cabling based on Ethernet
(ISO/IEC 8802-3) .80
Table C.3 – Network characteristics for optical fibre cabling .80
Table C.4 – Information relevant to copper cable: CP 3/3, CP 3/4, CP 3/5 and CP 3/6
type A fixed cables .82
Table C.5 – Information relevant to copper cable: CP 3/3, CP 3/4, CP 3/5 and CP 3/6
type B flexible cables .82
Table C.6 – Information relevant to copper cable: CP 3/3, CP 3/4, CP 3/5 and CP 3/6
type C special cables.83
Table C.7 – Information relevant to optical fibre cables.83
Table C.8 – Requirements for plastic and hard clad silica optical fibre cables .84
Table C.9 – Requirements for glass multimode optical fibre cables .85
Table C.10 – Requirements for glass singlemode optical fibre cables .86
Table C.11 – Information relevant to hybrid cables (application type B) .87
Table C.12 – Information relevant to hybrid cables (application type C) .87
Table C.13 – Connectors for balanced cabling CPs based on Ethernet .88
Table C.14 – Optical fibre connecting hardw
...

Questions, Comments and Discussion