IEC/PAS 62282-6-1
(First edition – 2006)
Fuel cell technologies –
Part 6-1: Micro fuel cell power systems – Safety

CORRIGENDUM 1
Page 22
4.21.1b)
Instead of:
“…J1.7.”
read:
“…J.17.”
Page 26
5.1.5
Instead of:
“Where a hazard is likely to occur…”

read:
“5.1.5.1 Where a hazard is likely to occur…”

Instead of:
“5.1.5.1 Mechanical movement…”

read:
“a) Mechanical movement…”
Instead of:
“5.1.5.2 In the case of a component…”

read:
“b) In the case of a component…”

Page 27
Instead of:
“5.1.5.3 The duration of each test…”

read:
“5.1.5.2 The duration of each test…”

Instead of:
“5.1.5.4 For equipment or components…”

read:
“a) For equipment or components…”

Instead of:
“5.1.5.5 For other equipment…”

read:
“b) For other equipment…”
Page 35
7.3.1.1
Instead of:
“Both test i) and test ii) are required.”
read:
“Both test a) and test b) are required.”

Test B Low external pressure
Instead of:
“Passing Criteria: No fire at any time, no explosion at any time, no leakage. See Figure 2.”
read:
“iii) Passing Criteria: No fire at any time, no explosion at any time, no leakage. See Figure 2.”

Page 51
A.3.27
Instead of:
“….to interpret correctly…”
read:
“…to not wrongly interpret…”
Page 54
A.7.3.14viii)b)
Instead of:
“If more than 25 % of LFL is not detected….”

read:
“If not more than 25 % of LFL is detected …”

A.7.3.14viii)c)3)
Instead of:
“If the spiral sweep does not detect any hydrogen concentrations of 25 % LFL or greater, then the device
passes.”
read:
“If the spiral sweep detects hydrogen concentrations of not more than 25 % LFL, then the device passes.”

Page 57
B.3.18
Instead of:
“hydrogen gas escaping from the cartridge or system does not result in …”
read:
“hydrogen gas escaping from the cartridge or system that results in …”
Page 64
B.7.3.1.1
Instead of:
“B.7.3.1.1 Test A
Test A of 7.3.1.1 is not applicable to cartridges tested under th
...