La présente Norme internationale prescrit, à des fins d'interchangeabilité, les dimensions et autres caractéristiques des plans de pose sur lesquels sont montés des limiteurs de pression pour transmissions hydrauliques.Elle est applicable aux plans de pose des limiteurs de pression pour transmissions hydrauliques, qui représentent la pratique courante; ils sont généralement utilisés dans les équipements industriels.
Fluidna tehnika - Hidravlika - Tlačni omejevalni ventili - Priključne površine
General Information
Relations
Buy Standard
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 6264
Second edition
1998-03-01
Hydraulic fluid power — Pressure-relief
valves — Mounting surfaces
Transmissions hydrauliques — Limiteurs de pression — Plan de pose
A
Reference number
ISO 6264:1998(E)
---------------------- Page: 1 ----------------------
ISO 6264:1998(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO
member bodies). The work of preparing International Standards is normally carried out through ISO technical
committees. Each member body interested in a subject for which a technical committee has been established has
the right to be represented on that committee. International organizations, governmental and non-governmental, in
liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical
Commission (IEC) on all matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are circulated to the member bodies for voting.
Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote.
International Standard ISO 6264 was prepared by Technical Committee ISO/TC 131, Fluid power systems,
Subcommittee SC 5, Control products and components.
This second edition cancels and replaces the first edition (ISO 6264:1987), of which it constitutes a technical
revisions.
Annex A of this International Standard is for information only.
© ISO 1998
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic
or mechanical, including photocopying and microfilm, without permission in writing from the publisher.
International Organization for Standardization
Case postale 56 • CH-1211 Genève 20 • Switzerland
Internet central@iso.ch
X.400 c=ch; a=400net; p=iso; o=isocs; s=central
Printed in Switzerland
ii
---------------------- Page: 2 ----------------------
©
ISO ISO 6264:1998(E)
Introduction
In hydraulic fluid power systems, power is transmitted and controlled through a liquid under pressure within an
enclosed circuit. Hydraulic valves are typical components in such systems. These devices control the flow direction,
pressure or flow rate of liquids in the enclosed circuit.
iii
---------------------- Page: 3 ----------------------
©
INTERNATIONAL STANDARD ISO ISO 6264:1998(E)
Hydraulic fluid power — Pressure-relief valves — Mounting
surfaces
1 Scope
This International Standard specifies the dimensions and other data relating to surfaces on which hydraulic
pressure-relief valves are mounted in order to ensure interchangeability.
It is applicable to mounting surfaces for hydraulic pressure-relief valves which represent current practice; they are
generally applicable to industrial equipment.
2 Normative references
The following standards contain provisions which, through reference of this text, constitute provisions of this
International Standard. At the time of publication, the editions indicated were valid. All standards are subject to
revision, and parties to agreements based on this International Standard are encouraged to investigate the
possibility of applying the most recent editions of the standards indicated below. Members of IEC and ISO maintain
registers of currently valid International Standards.
ISO 468:1982, Surface roughness — Parameters, their values and general rules for specifying requirements.
ISO 1101:1983, Technical drawing — Geometrical tolerancing — Tolerancing of form, orientation, location and run-
out — Generalities, definitions, symbols, indications on drawings.
ISO 1219-1:1991, Fluid power systems and components — Graphic symbols and circuit diagrams — Part 1:
Graphic symbols.
ISO 1302:1992, Technical drawing — Method of indicating surface texture.
ISO 4401:1994, .
Hydraulic fluid power — Four-port directional control valves — Mounting surfaces
ISO 5598:1985, Fluid power systems and components — Vocabulary.
ISO 5783:1995, Hydraulic fluid power — Code for identification of valve mounting surfaces and cartridge valve
cavities.
3 Definitions
For the purposes of this International Standard, the definitions given in ISO 5598 apply.
4 Symbols
4.1 For the purposes of this International Standard, the following symbols apply:
a) A, B, L, P, T and X designate ports;
1
---------------------- Page: 4 ----------------------
©
ISO
ISO 6264:1998(E)
b) F , F , F , F , F and F designate threaded holes for fixing bolts;
1 2 3 4 5 6
c) G designates pin holes;
d) designates the fixing screw diameter;
D
e) r designates mounting surface edge radius.
max
4.2 The graphic symbols used in figures 2, 3, 5, 6, 8, 10, 12, 14, 16 and 18 are in accordance with the graphic
symbols of ISO 1219-1.
4.3 The code system used in this International Standard is defined in ISO 5783.
5 Tolerances
5.1 The following values shall be applied to the mounting surface, i.e. the area within the chain thick lines:
surface roughness: R ¶ 0,8 μm (see ISO 468 and ISO 1302);
a
surface flatness: 0,01 mm over a distance of 100 mm (see ISO 1101);
tolerance for diameters of locating pin holes: H12.
5.2 The following tolerances shall be respected along the x and y axes with respect to the origin:
pin holes: ± 0,1 mm;
screw holes: ± 0,1 mm;
port holes: ± 0,2 mm.
For other dimensions, see the figures.
6 Dimensions
6.1 Mounting surface dimensions for hydraulic pressure-relief valves shall be selected from the figures specified in
6.2 to 6.6.
6.2 Mounting surface dimensions for pressure-relief valves with main ports of 4,5 mm maximum port diameter
(code: 6264-02-01-*-97) are given in figure 1.
6.3 Mounting surface dimensions for pressure-relief valves with main ports of 7,5 mm maximum port diameter
(code: 6264-03-04-*-97) are given in figure 4.
6.4 Mounting surface dimensions for pressure-relief valves with main ports of 14,7 mm maximum port diameter
(code: 6264-06-09-*-97) are given in figure 9.
6.5 Mounting surface dimensions for pressure-relief valves with main ports of 23,4 mm maximum port diameter
(code: 6264-08-13-*-97) are given in figure 13.
6.6 Mounting surface dimensions for pressure relief valves with main ports of 32 mm maximum port diameter
(code: 6264-10-17-*-97) are given in figure 17.
2
---------------------- Page: 5 ----------------------
©
ISO
ISO 6264:1998(E)
7 Port marking
7.1 The port symbols for pressure-relief valves shall be selected from the figures specified in 7.2 to 7.8.
7.2 Symbols for directly-operated pressure-relief valves with main ports of 4,5 mm maximum port diameter
(code: 6264-02-01-*-97) are given in figure 2.
7.3 Symbols for pilot-operated pressure-relief valves with main ports of 4,5 mm maximum port diameter
(code: 6264-02-01-*-97) are given in figure 3.
7.4 Symbols for directly-operated pressure-relief valves with main ports of 7,5 mm maximum port diameter
(code: 6264-03-04-*-97) are given in figure 5.
7.5 Symbols for pilot-operated pressure-relief valves with main ports of 7,5 mm maximum port diameter
(code: 6264-03-04-*-97) are given in figure 6.
7.6 Symbols for pilot-operated pressure-relief valves with main ports of 14,7 mm maximum port diameter
(code: 6264-06-09-*-97) are given in figure 10.
7.7 Symbols for pilot-operated pressure-relief valves with main ports of 23,4 mm maximum port diameter
(code: 6264-08-13-*-97) are given in figure 14.
7.8 Symbols for pilot-operated pressure-relief valves with main ports of 32 mm maximum port diameter
(code: 6264-10-17-*-97) are given in figure 18.
8 Modular stack valves
For modular stack valves, the mounting surfaces and ports marking defined in ISO 4401 shall be used.
9 Working pressure
For indication of the maximum limit of the working pressure, see note 1 in figures 1, 4, 9, 13 and 17.
10 Identification statement (Reference to this International Standard)
It is strongly recommended that manufacturers use the following statement in test reports, catalogues and sales
literature when electing to comply with this International Standard:
"Mounting surface dimensions conform to ISO 6264:1998, Hydraulic fluid power — Pressure-relief valves —
Mounting surfaces."
3
---------------------- Page: 6 ----------------------
©
ISO
ISO 6264:1998(E)
Code: 6264-02-01-*-97
Dimensions in millimetres
1)
The minimum thread depth is 1,5 times the screw diameter, D. The recommended full thread depth is 2D + 6 mm to
facilitate interchangeability of valves and to reduce the number of fixing screw lengths. The recommended engagement of
fixing screw thread for ferrous mountings is 1,25D.
2)
The dimensions specifying the area within the chain thick lines are the minimum dimensions for the mounting surface. The
corners of the rectangle may be radiused to a maximum radius, r , equal to the thread diameter of the fixing screws.
max
Along each axes the fixing holes are at equal distances to the mounting surface edges.
3)
This dimension gives the minimum space required for a valve with this mounting surface. The dimension is also the
minimum distance from centreline to centreline of two identical mounting surfaces placed on a manifold block.
The valve manufacturer's attention is drawn to the fact that no part of the width of the complete valve assembly shall exceed
this dimension.
4)
Blind hole in the mounting surface to accommodate the locating pin on the valves. The minimum depth is 4 mm.
NOTES
1 The supplier shall stipulate the maximum working pressure for subplates and manifold blocks.
2 See figures 2 and 3 for graphic symbols.
PA T B F F F F G
1 2 3 4
Axis
∅ 4,5 max. ∅ 4,5 max. ∅ 4,5 max. ∅ 4,5 max. M5 M5 M5 M5 ∅ 3,4
x 12 4,3 12 19,7 0 24 24 0 26,5
y 20,25 11,25 2,25 11,25 0 – 0,75 23,25 22,5 4,75
Figure 1 — Mounting surface for pressure-relief valves with main ports of 4,5 mm maximum port
diameter (size 02)
4
---------------------- Page: 7 ----------------------
©
ISO
ISO 6264:1998(E)
Option according to ISO 5783 0 1
Description External drain Internal drain
Pressure-relief valves
Pressure-relief valves with by-pass
check valve
Figure 2 — Directly-operated pressure-relief valves with main ports of 4,5 mm maximum port
diameter (code: 6264-02-01-*-97)
Option according to ISO 5783 2
Description External drain
Pressure-relief valves
Pressure-relief valves with by-pass
check valve
1)
Port for remote-controlled pilot; it may be blocked if not needed.
Figure 3 — Pilot-operated pressure-relief valves with main ports of 4,5 mm maximum port
diameter (code: 6264-02-01-*-97)
5
---------------------- Page: 8 ----------------------
©
ISO
ISO 6264:1998(E)
Code: 6264-03-04-*-97
Dimensions in millimetres
1)
The minimum thread depth is 1,5 times the screw diameter, D. The recommended full thread depth is 2D + 6 mm to
facilitate interchangeability of valves and to reduce the number of fixing screw lengths. The recommended engagement of
fixing screw thread for ferrous mountings is 1,25D.
2)
The dimensions specifying the area within the chain thick lines are the minimum dimensions for the mounting surface. The
corners of the rectangle may be radiused to a maximum radius, r , equal to the thread diameter of the fixing screws.
max
Along each axes the fixing holes are at equal distances to the mounting surface edges.
3)
This dimension gives the minimum space required for a valve with this mounting surface. The dimension is also the
minimum distance from centreline to centreline of two identical mounting surfaces placed on a manifold block.
The valve manufacturer's attention is drawn to the fact that no part of the width of the complete valve assembly shall exceed
this dimension.
4)
Blind hole in the mounting surface to accommodate the locating pin on the valves. The minimum depth is 4 mm.
NOTES
1 The supplier shall stipulate the maximum working pressure for subplates and manifold blocks.
2 See figures 5 and 6 for graphic symbols.
PA T B G F F F F
2 3 4
Axis 1
∅ 7,5 max. ∅ 7,5 max. ∅ 7,5 max. ∅ 7,5 max. ∅ 4 M5 M5 M5 M5
x 21,5 12,7 21,5 30,2 33 0 40,5 40,5 0
y 25,9 15,5 5,1 15,5 – 0,75 0 – 0,75 31,75 31
Figure 4 — Mounting surface for pressure-relief valves with main ports of 7,5 mm maximum port
diameter (size 03)
6
---------------------- Page: 9 ----------------------
©
ISO
ISO 6264:1998(E)
Option according to ISO 5783 0 1
Description External drain Internal drain
Pressure-relief valves
Pressure-relief valves with
by-pass check valve
Figure 5 — Directly-operated pressure-relief valves with main ports of 7,5 mm maximum port
diameter (code: 6264-03-04-*-97)
Option according to ISO 5783 2
Description External drain
Pressure-relief valves
Pressure-relief valves with by-pass
check valve
1) Port for remote-controlled pilot; it may be blocked if not needed.
Figure 6 — Pilot-operated pressure-relief valves with main ports of 7,5 mm maximum port
diameter (code: 6264-03-04-*-97)
7
---------------------- Page: 10 ----------------------
©
ISO
ISO 6264:1998(E)
Code: 6264-06-07-*-97
WARNING — This mounting surface has become obsolete. It is planned to remove it from this International
Standard at the next revision, in approximately five years. Do not use for new designs.
Dimensions in millimetres
1)
The minimum thread depth is 1,5 times the screw diameter, D. The recommended full thread depth is 2D + 6 mm to
facilitate interchangeability of valves and to reduce the number of fixing screw lengths. The recommended engagement of
fixing screw thread for ferrous mountings is 1,25D.
2)
The dimensions specifying the area within the chain thick lines are the minimum dimensions for the mounting surface. The
c
...
SLOVENSKI STANDARD
SIST ISO 6264:1998
01-december-1998
)OXLGQDWHKQLND+LGUDYOLND7ODþQLRPHMHYDOQLYHQWLOL3ULNOMXþQHSRYUãLQH
Hydraulic fluid power -- Pressure-relief valves -- Mounting surfaces
Transmissions hydrauliques -- Limiteurs de pression -- Plan de pose
Ta slovenski standard je istoveten z: ISO 6264:1998
ICS:
23.100.50 Krmilni sestavni deli Control components
SIST ISO 6264:1998 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST ISO 6264:1998
---------------------- Page: 2 ----------------------
SIST ISO 6264:1998
INTERNATIONAL ISO
STANDARD 6264
Second edition
1998-03-01
Hydraulic fluid power — Pressure-relief
valves — Mounting surfaces
Transmissions hydrauliques — Limiteurs de pression — Plan de pose
A
Reference number
ISO 6264:1998(E)
---------------------- Page: 3 ----------------------
SIST ISO 6264:1998
ISO 6264:1998(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO
member bodies). The work of preparing International Standards is normally carried out through ISO technical
committees. Each member body interested in a subject for which a technical committee has been established has
the right to be represented on that committee. International organizations, governmental and non-governmental, in
liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical
Commission (IEC) on all matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are circulated to the member bodies for voting.
Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote.
International Standard ISO 6264 was prepared by Technical Committee ISO/TC 131, Fluid power systems,
Subcommittee SC 5, Control products and components.
This second edition cancels and replaces the first edition (ISO 6264:1987), of which it constitutes a technical
revisions.
Annex A of this International Standard is for information only.
© ISO 1998
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic
or mechanical, including photocopying and microfilm, without permission in writing from the publisher.
International Organization for Standardization
Case postale 56 • CH-1211 Genève 20 • Switzerland
Internet central@iso.ch
X.400 c=ch; a=400net; p=iso; o=isocs; s=central
Printed in Switzerland
ii
---------------------- Page: 4 ----------------------
SIST ISO 6264:1998
©
ISO ISO 6264:1998(E)
Introduction
In hydraulic fluid power systems, power is transmitted and controlled through a liquid under pressure within an
enclosed circuit. Hydraulic valves are typical components in such systems. These devices control the flow direction,
pressure or flow rate of liquids in the enclosed circuit.
iii
---------------------- Page: 5 ----------------------
SIST ISO 6264:1998
---------------------- Page: 6 ----------------------
SIST ISO 6264:1998
©
INTERNATIONAL STANDARD ISO ISO 6264:1998(E)
Hydraulic fluid power — Pressure-relief valves — Mounting
surfaces
1 Scope
This International Standard specifies the dimensions and other data relating to surfaces on which hydraulic
pressure-relief valves are mounted in order to ensure interchangeability.
It is applicable to mounting surfaces for hydraulic pressure-relief valves which represent current practice; they are
generally applicable to industrial equipment.
2 Normative references
The following standards contain provisions which, through reference of this text, constitute provisions of this
International Standard. At the time of publication, the editions indicated were valid. All standards are subject to
revision, and parties to agreements based on this International Standard are encouraged to investigate the
possibility of applying the most recent editions of the standards indicated below. Members of IEC and ISO maintain
registers of currently valid International Standards.
ISO 468:1982, Surface roughness — Parameters, their values and general rules for specifying requirements.
ISO 1101:1983, Technical drawing — Geometrical tolerancing — Tolerancing of form, orientation, location and run-
out — Generalities, definitions, symbols, indications on drawings.
ISO 1219-1:1991, Fluid power systems and components — Graphic symbols and circuit diagrams — Part 1:
Graphic symbols.
ISO 1302:1992, Technical drawing — Method of indicating surface texture.
ISO 4401:1994, .
Hydraulic fluid power — Four-port directional control valves — Mounting surfaces
ISO 5598:1985, Fluid power systems and components — Vocabulary.
ISO 5783:1995, Hydraulic fluid power — Code for identification of valve mounting surfaces and cartridge valve
cavities.
3 Definitions
For the purposes of this International Standard, the definitions given in ISO 5598 apply.
4 Symbols
4.1 For the purposes of this International Standard, the following symbols apply:
a) A, B, L, P, T and X designate ports;
1
---------------------- Page: 7 ----------------------
SIST ISO 6264:1998
©
ISO
ISO 6264:1998(E)
b) F , F , F , F , F and F designate threaded holes for fixing bolts;
1 2 3 4 5 6
c) G designates pin holes;
d) designates the fixing screw diameter;
D
e) r designates mounting surface edge radius.
max
4.2 The graphic symbols used in figures 2, 3, 5, 6, 8, 10, 12, 14, 16 and 18 are in accordance with the graphic
symbols of ISO 1219-1.
4.3 The code system used in this International Standard is defined in ISO 5783.
5 Tolerances
5.1 The following values shall be applied to the mounting surface, i.e. the area within the chain thick lines:
surface roughness: R ¶ 0,8 μm (see ISO 468 and ISO 1302);
a
surface flatness: 0,01 mm over a distance of 100 mm (see ISO 1101);
tolerance for diameters of locating pin holes: H12.
5.2 The following tolerances shall be respected along the x and y axes with respect to the origin:
pin holes: ± 0,1 mm;
screw holes: ± 0,1 mm;
port holes: ± 0,2 mm.
For other dimensions, see the figures.
6 Dimensions
6.1 Mounting surface dimensions for hydraulic pressure-relief valves shall be selected from the figures specified in
6.2 to 6.6.
6.2 Mounting surface dimensions for pressure-relief valves with main ports of 4,5 mm maximum port diameter
(code: 6264-02-01-*-97) are given in figure 1.
6.3 Mounting surface dimensions for pressure-relief valves with main ports of 7,5 mm maximum port diameter
(code: 6264-03-04-*-97) are given in figure 4.
6.4 Mounting surface dimensions for pressure-relief valves with main ports of 14,7 mm maximum port diameter
(code: 6264-06-09-*-97) are given in figure 9.
6.5 Mounting surface dimensions for pressure-relief valves with main ports of 23,4 mm maximum port diameter
(code: 6264-08-13-*-97) are given in figure 13.
6.6 Mounting surface dimensions for pressure relief valves with main ports of 32 mm maximum port diameter
(code: 6264-10-17-*-97) are given in figure 17.
2
---------------------- Page: 8 ----------------------
SIST ISO 6264:1998
©
ISO
ISO 6264:1998(E)
7 Port marking
7.1 The port symbols for pressure-relief valves shall be selected from the figures specified in 7.2 to 7.8.
7.2 Symbols for directly-operated pressure-relief valves with main ports of 4,5 mm maximum port diameter
(code: 6264-02-01-*-97) are given in figure 2.
7.3 Symbols for pilot-operated pressure-relief valves with main ports of 4,5 mm maximum port diameter
(code: 6264-02-01-*-97) are given in figure 3.
7.4 Symbols for directly-operated pressure-relief valves with main ports of 7,5 mm maximum port diameter
(code: 6264-03-04-*-97) are given in figure 5.
7.5 Symbols for pilot-operated pressure-relief valves with main ports of 7,5 mm maximum port diameter
(code: 6264-03-04-*-97) are given in figure 6.
7.6 Symbols for pilot-operated pressure-relief valves with main ports of 14,7 mm maximum port diameter
(code: 6264-06-09-*-97) are given in figure 10.
7.7 Symbols for pilot-operated pressure-relief valves with main ports of 23,4 mm maximum port diameter
(code: 6264-08-13-*-97) are given in figure 14.
7.8 Symbols for pilot-operated pressure-relief valves with main ports of 32 mm maximum port diameter
(code: 6264-10-17-*-97) are given in figure 18.
8 Modular stack valves
For modular stack valves, the mounting surfaces and ports marking defined in ISO 4401 shall be used.
9 Working pressure
For indication of the maximum limit of the working pressure, see note 1 in figures 1, 4, 9, 13 and 17.
10 Identification statement (Reference to this International Standard)
It is strongly recommended that manufacturers use the following statement in test reports, catalogues and sales
literature when electing to comply with this International Standard:
"Mounting surface dimensions conform to ISO 6264:1998, Hydraulic fluid power — Pressure-relief valves —
Mounting surfaces."
3
---------------------- Page: 9 ----------------------
SIST ISO 6264:1998
©
ISO
ISO 6264:1998(E)
Code: 6264-02-01-*-97
Dimensions in millimetres
1)
The minimum thread depth is 1,5 times the screw diameter, D. The recommended full thread depth is 2D + 6 mm to
facilitate interchangeability of valves and to reduce the number of fixing screw lengths. The recommended engagement of
fixing screw thread for ferrous mountings is 1,25D.
2)
The dimensions specifying the area within the chain thick lines are the minimum dimensions for the mounting surface. The
corners of the rectangle may be radiused to a maximum radius, r , equal to the thread diameter of the fixing screws.
max
Along each axes the fixing holes are at equal distances to the mounting surface edges.
3)
This dimension gives the minimum space required for a valve with this mounting surface. The dimension is also the
minimum distance from centreline to centreline of two identical mounting surfaces placed on a manifold block.
The valve manufacturer's attention is drawn to the fact that no part of the width of the complete valve assembly shall exceed
this dimension.
4)
Blind hole in the mounting surface to accommodate the locating pin on the valves. The minimum depth is 4 mm.
NOTES
1 The supplier shall stipulate the maximum working pressure for subplates and manifold blocks.
2 See figures 2 and 3 for graphic symbols.
PA T B F F F F G
1 2 3 4
Axis
∅ 4,5 max. ∅ 4,5 max. ∅ 4,5 max. ∅ 4,5 max. M5 M5 M5 M5 ∅ 3,4
x 12 4,3 12 19,7 0 24 24 0 26,5
y 20,25 11,25 2,25 11,25 0 – 0,75 23,25 22,5 4,75
Figure 1 — Mounting surface for pressure-relief valves with main ports of 4,5 mm maximum port
diameter (size 02)
4
---------------------- Page: 10 ----------------------
SIST ISO 6264:1998
©
ISO
ISO 6264:1998(E)
Option according to ISO 5783 0 1
Description External drain Internal drain
Pressure-relief valves
Pressure-relief valves with by-pass
check valve
Figure 2 — Directly-operated pressure-relief valves with main ports of 4,5 mm maximum port
diameter (code: 6264-02-01-*-97)
Option according to ISO 5783 2
Description External drain
Pressure-relief valves
Pressure-relief valves with by-pass
check valve
1)
Port for remote-controlled pilot; it may be blocked if not needed.
Figure 3 — Pilot-operated pressure-relief valves with main ports of 4,5 mm maximum port
diameter (code: 6264-02-01-*-97)
5
---------------------- Page: 11 ----------------------
SIST ISO 6264:1998
©
ISO
ISO 6264:1998(E)
Code: 6264-03-04-*-97
Dimensions in millimetres
1)
The minimum thread depth is 1,5 times the screw diameter, D. The recommended full thread depth is 2D + 6 mm to
facilitate interchangeability of valves and to reduce the number of fixing screw lengths. The recommended engagement of
fixing screw thread for ferrous mountings is 1,25D.
2)
The dimensions specifying the area within the chain thick lines are the minimum dimensions for the mounting surface. The
corners of the rectangle may be radiused to a maximum radius, r , equal to the thread diameter of the fixing screws.
max
Along each axes the fixing holes are at equal distances to the mounting surface edges.
3)
This dimension gives the minimum space required for a valve with this mounting surface. The dimension is also the
minimum distance from centreline to centreline of two identical mounting surfaces placed on a manifold block.
The valve manufacturer's attention is drawn to the fact that no part of the width of the complete valve assembly shall exceed
this dimension.
4)
Blind hole in the mounting surface to accommodate the locating pin on the valves. The minimum depth is 4 mm.
NOTES
1 The supplier shall stipulate the maximum working pressure for subplates and manifold blocks.
2 See figures 5 and 6 for graphic symbols.
PA T B G F F F F
2 3 4
Axis 1
∅ 7,5 max. ∅ 7,5 max. ∅ 7,5 max. ∅ 7,5 max. ∅ 4 M5 M5 M5 M5
x 21,5 12,7 21,5 30,2 33 0 40,5 40,5 0
y 25,9 15,5 5,1 15,5 – 0,75 0 – 0,75 31,75 31
Figure 4 — Mounting surface for pressure-relief valves with main ports of 7,5 mm maximum port
diameter (size 03)
6
---------------------- Page: 12 ----------------------
SIST ISO 6264:1998
©
ISO
ISO 6264:1998(E)
Option according to ISO 5783 0 1
Description External drain Internal drain
Pressure-relief valves
Pressure-relief valves with
by-pass check valve
Figure 5 — Directly-operated pressure-relief valves with main ports of 7,5 mm maximum port
diameter (code: 6264-03-04-*-97)
Option according to ISO 5783 2
Description External drain
Pressure-relief valves
Pressure-relief valves with by-pass
check valve
1) Port for remote-controlled pilot; it may be blocked if not needed.
Figure 6 — Pilot-operated pressure-relief valves with main ports of 7,5 mm maximum port
diameter (code: 6264-03-04-*-97)
7
---------------------- Page: 13 ----------------------
SIST ISO 6264:1998
©
ISO
ISO 6264:1998(E)
Code: 6264-06-07-*-97
WARNING — This mounting surface has become obsolete. It is planned to remove it from this International
...
NORME ISO
INTERNATIONALE 6264
Deuxième édition
1998-03-01
Transmissions hydrauliques — Limiteurs
de pression — Plan de pose
Hydraulic fluid power — Pressure-relief valves — Mounting surfaces
A
Numéro de référence
ISO 6264:1998(F)
---------------------- Page: 1 ----------------------
ISO 6264:1998(F)
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée aux
comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du comité
technique créé à cet effet. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec la Commission
électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les projets de Normes internationales adoptés par les comités techniques sont soumis aux comités membres pour
vote. Leur publication comme Normes internationales requiert l'approbation de 75 % au moins des comités
membres votants.
La Norme internationale ISO 6264 a été élaborée par le comité technique ISO/TC 131, Transmissions hydrauliques
et pneumatiques, sous-comité SC 5, Appareils de régulation et de distribution et leurs composants.
Cette deuxième édition annule et remplace la première édition (ISO 6264:1987), dont elle constitue une révision
technique.
L'annexe A de la présente Norme internationale est donnée uniquement à titre d’information.
© ISO 1998
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous quelque
forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit de l'éditeur.
Organisation internationale de normalisation
Case postale 56 • CH-1211 Genève 20 • Suisse
Internet central@iso.ch
X.400 c=ch; a=400net; p=iso; o=isocs; s=central
Imprimé en Suisse
ii
---------------------- Page: 2 ----------------------
©
ISO ISO 6264:1998(F)
Introduction
Dans les systèmes de transmissions hydrauliques, l'énergie est transmise et commandée par l'intermédiaire d'un
liquide sous pression circulant en circuit fermé. Les distributeurs hydrauliques sont des composants typiques de ces
systèmes. Ces dispositifs commandent le sens d'écoulement, la pression ou le débit des liquides dans le circuit
fermé.
iii
---------------------- Page: 3 ----------------------
©
NORME INTERNATIONALE ISO ISO 6264:1998(F)
Transmissions hydrauliques — Limiteurs de pression —
Plan de pose
1 Domaine d'application
La présente Norme internationale prescrit, à des fins d'interchangeabilité, les dimensions et autres caractéristiques
des plans de pose sur lesquels sont montés des limiteurs de pression pour transmissions hydrauliques.
Elle est applicable aux plans de pose des limiteurs de pression pour transmissions hydrauliques, qui représentent la
pratique courante; ils sont généralement utilisés dans les équipements industriels.
2 Références normatives
Les normes suivantes contiennent des dispositions qui, par suite de la référence qui en est faite, constituent des
dispositions valables pour la présente Norme internationale. Au moment de la publication, les éditions indiquées
étaient en vigueur. Toute norme est sujette à révision et les parties prenantes des accords fondés sur la présente
Norme internationale sont invitées à rechercher la possibilité d'appliquer les éditions les plus récentes des normes
indiquées ci-après. Les membres de la CEI et de l'ISO possèdent le registre des Normes internationales en vigueur
à un moment donné.
ISO 468:1982, Rugosité de surface — Paramètres, leurs valeurs et règles générales de la détermination des
spécifications.
ISO 1101:1983, Dessins techniques — Tolérancement géométriques — Tolérancement de forme, orientation,
position et battement — Généralités, définitions, symboles, indications sur les dessins.
ISO 1219-1:1991, Transmissions hydrauliques et pneumatiques — Symboles graphiques et schémas de circuits —
Partie 1: Symboles graphiques.
ISO 1302:1992, Dessins techniques — Indications des états de surface.
ISO 4401:1994, Transmissions hydrauliques — Distributeurs à quatre orifices — Plan de pose.
ISO 5598:1985, Transmissions hydrauliques et pneumatiques — Vocabulaire.
ISO 5783:1995, Transmissions hydrauliques — Code pour l'identification des plans de pose et des logements de
cartouche.
3 Définitions
Pour les besoins de la présente Norme internationale, les définitions données dans l'ISO 5598 s'appliquent.
1
---------------------- Page: 4 ----------------------
©
ISO
ISO 6264:1998(F)
4 Symboles
Pour les besoins de la présente Norme internationale, les symboles suivants s'appliquent:
4.1
a) A, B, L, P, T et X désignent les orifices;
b) F , F , F , F , F et F désignent les trous taraudés pour les vis de fixation;
1 2 3 4 5 6
c) G désigne les trous de détrompeur;
d) D désigne le diamètre des vis de fixation;
e) r désigne le rayon de raccordement des bords du plan de pose.
max
4.2 Les symboles graphiques utilisés aux figures 2, 3, 5, 6, 8, 10, 12, 14, 16 et 18 sont conformes aux symboles
graphiques de l'ISO 1219-1.
4.3 La codification utilisée dans la présente Norme internationale est définie dans l'ISO 5783.
5 Tolérances
5.1 Les valeurs suivantes doivent s'appliquer au plan de pose, c'est-à-dire à la surface délimitée par des traits
mixtes forts:
— rugosité de surface: R < 0,8 μm (voir ISO 468 et ISO 1302);
a
— planéité de surface: 0,01 mm sur une distance de 100 mm (voir ISO 1101);
— tolérance sur les diamètres des trous de détrompeur: H12.
5.2 Par rapport au point origine, suivant les axes x et y, les tolérances suivantes doivent être respectées:
— trous de détrompeur: ± 0,1 mm;
— trous taraudés: ± 0,1 mm;
— orifices principaux: ± 0,2 mm.
En ce qui concerne les autres dimensions, se reporter aux figures.
6 Dimensions
6.1 Les dimensions des plans de pose pour limiteurs de pression pour transmissions hydrauliques doivent être
choisies parmi les figures spécifiées de 6.2 à 6.6.
6.2 Les dimensions des plans de pose pour limiteurs de pression avec orifices principaux de diamètre maximal
4,5 mm (code: 6264-02-01-*-97) sont données à la figure 1.
6.3 Les dimensions des plans de pose pour limiteurs de pression avec orifices principaux de diamètre maximal
7,5 mm (code: 6264-03-04-*-97) sont données à la figure 4.
6.4 Les dimensions des plans de pose pour limiteurs de pression avec orifices principaux de diamètre maximal
14,7 mm (code: 6264-06-09-*-97) sont données à la figure 9.
6.5 Les dimensions des plans de pose pour limiteurs de pression avec orifices principaux de diamètre maximal
23,4 mm (code: 6264-08-13-*-97) sont données à la figure 13.
6.6 Les dimensions des plans de pose pour limiteurs de pression avec orifices principaux de diamètre maximal
32 mm (code: 6264-10-17-*-97) sont données à la figure 17.
2
---------------------- Page: 5 ----------------------
©
ISO
ISO 6264:1998(F)
7 Marquage des orifices
7.1 Les symboles des orifices à utiliser pour les limiteurs de pression doivent être choisis parmi les figures
spécifiées de 7.2 à 7.8.
7.2 Les symboles des orifices à utiliser pour les limiteurs de pression à action directe avec orifices principaux de
diamètre maximal 4,5 mm (code: 6264-02-01-*-97) sont donnés à la figure 2.
7.3 Les symboles des orifices à utiliser pour les limiteurs de pression pilotés avec orifices principaux de diamètre
maximal 4,5 mm (code: 6264-02-01-*-97) sont donnés à la figure 3.
7.4 Les symboles des orifices à utiliser pour les limiteurs de pression à action directe avec orifices principaux de
diamètre maximal 7,5 mm (code: 6264-03-04-*-97) sont donnés à la figure 5.
7.5 Les symboles des orifices à utiliser pour les limiteurs de pression pilotés avec orifices principaux de diamètre
maximal 7,5 mm (code: 6264-03-04-*-97) sont donnés à la figure 6.
7.6 Les symboles des orifices à utiliser pour les limiteurs de pression pilotés avec orifices principaux de diamètre
maximal 14,7 mm (code: 6264-06-09-*-97) sont donnés à la figure 10.
7.7 Les symboles des orifices à utiliser pour les limiteurs de pression pilotés avec orifices principaux de diamètre
maximal 23,4 mm (code: 6264-08-13-*-97) sont donnés à la figure 14.
7.8 Les symboles des orifices à utiliser pour les limiteurs de pression pilotés avec orifices principaux de diamètre
maximal 32 mm (code: 6264-10-17-*-97) sont donnés à la figure 18.
8 Appareils empilables
Pour les appareils empilables, les plans de poses et le marquage des orifices définis dans l'ISO 4401 doivent être
utilisés.
9 Pression de fonctionnement
Pour l'indication de la limite maximale de la pression de fonctionnement, voir la note 1 des figures 1, 4, 9, 13 et 17.
10 Phrase d'identification (Référence à la présente Norme internationale)
Il est vivement recommandé aux fabricants qui ont choisi de se conformer à la présente Norme internationale
d'utiliser dans leurs rapports d'essai, catalogues et documentation commerciale, la phrase d'identification suivante
:
«Les dimensions des plans de pose des limiteurs de pression sont conformes à l'ISO 6264:1998, Transmissions
hydrauliques — Limiteurs de pression — Plan de pose.»
3
---------------------- Page: 6 ----------------------
©
ISO
ISO 6264:1998(F)
Code: 6264-02-01-*-97
Dimensions en millimètres
1) La profondeur minimale du taraudage est de 1,5 fois le diamètre de la vis, D. La profondeur de filetage recommandée est
2D + 6 mm pour faciliter l’interchangeabilité des distributeurs et réduire le nombre de longueurs de vis de fixation. La longueur
en prise recommandée des vis de fixation sur les embases en métaux ferreux est 1,25 D.
2) Les dimensions caractérisant la surface délimitée par les traits mixtes forts sont les dimensions minimales du plan de pose.
Les angles du rectangle peuvent être arrondis avec un rayon maximal, r , égal au diamètre de filetage des vis de fixation.
max
Sur chaque axe, les trous de fixation sont à égale distance des bords du plan de pose.
3) Cette dimension donne l’intervalle minimal requis pour le montage d’un distributeur. Cette dimension est aussi la distance
minimale entre axes centraux de deux plans de pose identiques placés sur un bloc multiple.
L’attention des constructeurs de distributeurs est attirée sur le fait que le distributeur complètement monté ne doit jamais
dépasser cette dimension en largeur.
4) Trou borgne pratiqué dans le plan de pose pour recevoir le détrompeur monté sur l’appareil; sa profondeur minimale est de
4 mm.
NOTES
1 La pression de fonctionnement maximale des embases et des blocs multiples doit être stipulée par le constructeur.
2 Voir les figures 2 et 3 pour les symboles graphiques.
PA T B F F F F G
1 2 3 4
Axe
∅ 4,5 max. ∅ 4,5 max. ∅ 4,5 max. ∅ 4,5 max. M5 M5 M5 M5 ∅ 3,4
x 12 4,3 12 19,7 0 24 24 0 26,5
y 20,25 11,25 2,25 11,25 0 – 0,75 23,25 22,5 4,75
Figure 1 — Plan de pose pour limiteurs de pression avec orifices principaux de diamètre maximal 4,5 mm
(taille 02)
4
---------------------- Page: 7 ----------------------
©
ISO
ISO 6264:1998(F)
Option conforme à l’ISO 5783 0 1
Description Drain externe Drain interne
Limiteurs de pression
Limiteurs de pression avec clapet
de non-retour
Figure 2 — Limiteurs de pression à action directe avec orifices principaux de diamètre maximal 4,5 mm
(code: 6264-02-01-*-97)
Option conforme à l’ISO 5783 2
Description Drain externe
Limiteurs de pression
Limiteurs de pression avec clapet
de non-retour
1)
Orifice pour pilotage à distance; il peut être bouché en cas de non-utilisation.
Figure 3 — Limiteurs de pression pilotés avec orifices principaux de diamètre maximal 4,5 mm
(code: 6264-02-01-*-97)
5
---------------------- Page: 8 ----------------------
©
ISO
ISO 6264:1998(F)
Code: 6264-03-04-*-97
Dimensions en millimètres
1) La profondeur minimale du taraudage est de 1,5 fois le diamètre de la vis, D. La profondeur de filetage recommandée est
2D + 6 mm pour faciliter l’interchangeabilité des distributeurs et réduire le nombre de longueurs de vis de fixation. La longueur
en prise recommandée des vis de fixation sur les embases en métaux ferreux est 1,25 D.
2) Les dimensions caractérisant la surface délimitée par les traits mixtes forts sont les dimensions minimales du plan de pose.
Les angles du rectangle peuvent être arrondis avec un rayon maximal, r , égal au diamètre de filetage des vis de fixation.
max
Sur chaque axe, les trous de fixation sont à égale distance des bords du plan de pose.
3) Cette dimension donne l’intervalle minimal requis pour le montage d’un distributeur. Cette dimension est aussi la distance
minimale entre axes centraux de deux plans de pose identiques placés sur un bloc multiple.
L’attention des constructeurs de distributeurs est attirée sur le fait que le distributeur complètement monté ne doit jamais
dépasser cette dimension en largeur.
4) Trou borgne pratiqué dans le plan de pose pour recevoir le détrompeur monté sur l’appareil; sa profondeur minimale est de
4 mm.
NOTES
1 La pression de fonctionnement maximale des embases et des blocs multiples doit être stipulée par le constructeur.
2 Voir les figures 5 et 6 pour les symboles graphiques.
PA T B G F F F F
2 3 4
Axe 1
∅ 7,5 max. ∅ 7,5 max. ∅ 7,5 max. ∅ 7,5 max. ∅ 4 M5 M5 M5 M5
x 21,5 12,7 21,5 30,2 33 0 40,5 40,5 0
y 25,9 15,5 5,1 15,5 – 0,75 0 – 0,75 31,75 31
Figure 4 — Plan de pose pour limiteurs de pression avec orifices principaux de diamètre maximal 7,5 mm
(taille 03)
6
---------------------- Page: 9 ----------------------
©
ISO
ISO 6264:1998(F)
Option conforme à l’ISO 5783 0 1
Description Drain externe Drain interne
Limiteurs de pression
Limiteurs de pression avec clapet
de non-retour
Figure 5 — Limiteurs de pression à action directe avec orifices principaux de diamètre maximal 7,5 mm
(code: 6264-03-04-*-97)
Option conforme à l’ISO 5783 2
Description Drain externe
Limiteurs de pression
Limiteurs de pression avec clapet
de non-retour
1)
Orifice pour pilotage à distance; il peut être bouché en cas de non-utilisation.
Figure 6 — Limiteurs de pression pilotés avec orifices principaux de diamètre maximal 7,5 mm
(code: 6264-03-04-*-97)
7
---------------------- Page: 10 ----------------------
©
ISO
ISO 6264:1998(F)
Code: 6264-06-07-*-97
ATTENTION — Ce plan de pose est devenu obsolète. Il est prévu de le supprimer de la présente Norme
internationale lors de sa prochaine révision, dans environ 5 ans. À ne pas utiliser pour de nouvelles conceptions.
Dimensions en millimètres
1) La profondeur minimale du taraudage est de 1,5 fois le diamètre de la vis, D. La profondeur de filetage recommandée est
2D + 6 mm pour faciliter l’interchangeabilité des distributeur
...
Questions, Comments and Discussion