Hard coal and coke -- Guidance to the inspection of mechanical sampling systems

This document sets out recommended practices for the inspection of mechanical sampling systems. It serves as a guide for conformance with applicable ISO/TC 27 standards. This document covers general considerations including precision, mineral variability and bias, establishment of inspection systems and inspection procedure.

Houille et coke -- Lignes directrices pour l'inspection des systèmes d'échantillonnage mécanique

General Information

Status
Published
Publication Date
14-Oct-2019
Technical Committee
Drafting Committee
Current Stage
6060 - International Standard published
Start Date
21-Sep-2019
Completion Date
15-Oct-2019
Ref Project

RELATIONS

Buy Standard

Standard
ISO 21398:2019 - Hard coal and coke -- Guidance to the inspection of mechanical sampling systems
English language
23 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (sample)

INTERNATIONAL ISO
STANDARD 21398
Second edition
2019-10
Hard coal and coke — Guidance
to the inspection of mechanical
sampling systems
Houille et coke — Lignes directrices pour l'inspection des systèmes
d'échantillonnage mécanique
Reference number
ISO 21398:2019(E)
ISO 2019
---------------------- Page: 1 ----------------------
ISO 21398:2019(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2019

All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may

be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting

on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address

below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Fax: +41 22 749 09 47
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii © ISO 2019 – All rights reserved
---------------------- Page: 2 ----------------------
ISO 21398:2019(E)
Contents Page

Foreword ........................................................................................................................................................................................................................................iv

Introduction ..................................................................................................................................................................................................................................v

1 Scope ................................................................................................................................................................................................................................. 1

2 Normative references ...................................................................................................................................................................................... 1

3 Terms and definitions ..................................................................................................................................................................................... 1

4 Safety ................................................................................................................................................................................................................................ 1

5 General considerations .................................................................................................................................................................................. 2

5.1 Precision ....................................................................................................................................................................................................... 2

5.2 Bias .................................................................................................................................................................................................................... 2

5.3 Operation of sampling system ................................................................................................................................................... 2

6 Establishment of inspection system ................................................................................................................................................. 2

6.1 General ........................................................................................................................................................................................................... 2

6.2 Audit — External ................................................................................................................................................................................... 3

6.3 Audit — Internal .................................................................................................................................................................................... 3

6.4 Operational inspections .................................................................................................................................................................. 3

7 Procedures .................................................................................................................................................................................................................. 3

7.1 Audit — External ................................................................................................................................................................................... 3

7.2 Audit — Internal .................................................................................................................................................................................... 4

7.3 Operational inspections .................................................................................................................................................................. 5

8 Quality control ........................................................................................................................................................................................................ 6

8.1 General ........................................................................................................................................................................................................... 6

8.2 Sampling ratio .......................................................................................................................................................................................... 6

8.3 Coefficient of variation ..................................................................................................................................................................... 6

8.4 Extraction ratio ....................................................................................................................................................................................... 7

8.5 Sampling records .................................................................................................................................................................................. 7

8.6 Operators’ inspection report ...................................................................................................................................................... 7

Annex A (informative) Monitoring coal sampling ratios using control charts.......................................................11

Annex B (informative) Examples of sampling checklists .............................................................................................................15

Annex C (informative) Example of sampling plant operator’s inspection report ...............................................18

Annex D (informative) Examples of sampling plant operations inspection summary..................................21

Bibliography .............................................................................................................................................................................................................................23

© ISO 2019 – All rights reserved iii
---------------------- Page: 3 ----------------------
ISO 21398:2019(E)
Foreword

ISO (the International Organization for Standardization) is a worldwide federation of national standards

bodies (ISO member bodies). The work of preparing International Standards is normally carried out

through ISO technical committees. Each member body interested in a subject for which a technical

committee has been established has the right to be represented on that committee. International

organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.

ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of

electrotechnical standardization.

The procedures used to develop this document and those intended for its further maintenance are

described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the

different types of ISO documents should be noted. This document was drafted in accordance with the

editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/ directives).

Attention is drawn to the possibility that some of the elements of this document may be the subject of

patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of

any patent rights identified during the development of the document will be in the Introduction and/or

on the ISO list of patent declarations received (see www .iso .org/ patents).

Any trade name used in this document is information given for the convenience of users and does not

constitute an endorsement.

For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and

expressions related to conformity assessment, as well as information about ISO's adherence to the

World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see www .iso .org/

iso/ foreword .html.

This document was prepared by Technical Committee ISO/TC 27, Solid mineral fuels, Subcommittee

SC 4, Sampling.

This second edition cancels and replaces the first edition (ISO 21398:2007), of which it constitutes a

minor revision. The changes compared to the previous edition are as follows:
— the normative references have been updated and the dates removed;
— the references in Clause 5 have been updated;
— Bibliographic references have been updated.

Any feedback or questions on this document should be directed to the user’s national standards body. A

complete listing of these bodies can be found at www .iso .org/ members .html.
iv © ISO 2019 – All rights reserved
---------------------- Page: 4 ----------------------
ISO 21398:2019(E)
Introduction

The objective of this document is to provide users of new and existing mechanical sampling systems for

minerals with guidance on their operation and inspection.
An ‘informative’ annex is for information and guidance only.
© ISO 2019 – All rights reserved v
---------------------- Page: 5 ----------------------
INTERNATIONAL STANDARD ISO 21398:2019(E)
Hard coal and coke — Guidance to the inspection of
mechanical sampling systems
1 Scope

This document sets out recommended practices for the inspection of mechanical sampling systems. It

serves as a guide for conformance with applicable ISO/TC 27 standards.

This document covers general considerations including precision, mineral variability and bias,

establishment of inspection systems and inspection procedure.
2 Normative references

The following documents are referred to in the text in such a way that some or all of their content

constitutes requirements of this document. For dated references, only the edition cited applies. For

undated references, the latest edition of the referenced document (including any amendments) applies.

ISO 13909 (all parts), Hard coal and coke — Mechanical sampling
3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 13909-1 and the following apply.

ISO and IEC maintain terminological databases for use in standardization at the following addresses:

— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at http:// www .electropedia .org/
3.1
audit

critical review of a mechanical sampling system, which measures its conformance with

stipulated operating specifications, undertaken by a suitably qualified independent person who is not

directly involved in the management of that system
3.2
audit

critical inspection and review of a mechanical sampling system, which measures its

conformance with stipulated operation specifications, undertaken by a suitably qualified person who is

not a day-to-day operator of that particular system
3.3
operational inspection

observations and inspections of operation conditions undertaken by the operator during sampling of a lot

Note 1 to entry: The operator is the person responsible for monitoring the sampling system on a shift-to-shift basis.

4 Safety

This document does not purport to address safety issues that can be associated with its use. It is the

responsibility of the user of this document to establish appropriate safety and health practices in line

with site safety regulations and relevant Occupational Health and Safety Acts. It is highly recommended

that the auditor or inspector start by conducting a careful review of all safety rules and procedures

regarding the sampling system to be inspected.
© ISO 2019 – All rights reserved 1
---------------------- Page: 6 ----------------------
ISO 21398:2019(E)
5 General considerations
5.1 Precision

Precision tests are recommended for each coal or coke type used in the system. If there is a significant

change in a coal or coke type or a new coal or coke type introduced, then a precision test should be

carried out. These tests should be in accordance with ISO 13909-7. The Manager or Supervisor should

maintain a record of the precision of sampling, preparation and analysis of each type of coal and coke

sampled with the system.
5.2 Bias

It is recommended that, after commissioning and auditing of a new system or any major engineering

modifications of an existing system, a bias test be carried out to confirm the system. It is recommended

that the system be verified in accordance with ISO 13909 (all parts) procedures. Reference is made to

ISO 13909-2, and ISO 13909-5, where bias tests may be mandatory under certain conditions. When

choosing a coal or coke type for bias testing, refer to ISO 13909-8. It is recommended that further

bias sample pairs be taken on a regular basis to confirm that the initial bias result is still relevant. If

a significant change is made to the sampling system, or a new mineral having more difficult sampling

characteristics is introduced, a new bias test should be considered.
5.3 Operation of sampling system

The mechanical plant system should be started some time in advance of the start of conveying the coal

or coke so that any foreign substances (including water) are purged. Where hydraulic drives are used,

sufficient time should be allowed for the hydraulic oil and the associated system to attain temperature

equilibrium. It is recommended, particularly in multi-coal or coke sampling systems, that one primary

cut be allowed to pass through the mechanical system as a conditioner before actual sampling

commences.

It is recommended that the operator review any sampling records for the plant maintained by the

previous operator. These records should include quantities of coal or coke handled and sampled, and

notations as to system malfunctions, stoppages, blockages or other deficiencies. The operator should

use a suitable checklist, such as the example given in Annex A. It is recommended that the operator

complete all items on a suitable checklist designed for the system. For large, multi-user systems, an

operators’ inspection report, such as the example in given Annex B, should be developed.

Sufficient suitably designed inspection points should be available to observe that the falling-stream

and cross-belt cutters cut the full stream of coal or coke and that cutter apertures can be inspected for

blockages and blinding.
6 Establishment of inspection system
6.1 General

6.1.1 To ensure reliable operation, it is recommended that a sampling checklist (see Annex B) and

operators’ sampling record (see Annex C) be developed with input from the following sources:

a) original design criteria;
b) sampling equipment operating and maintenance manuals;
c) management responsible for the system;
d) personnel operating or maintaining the system;
e) for a new system, the designers and commissioning personnel;
2 © ISO 2019 – All rights reserved
---------------------- Page: 7 ----------------------
ISO 21398:2019(E)
f) relevant International Standards where applicable;
6.1.2 The general method for establishing these procedures is as follows:

a) Reference should be made to ISO 13909-2 and ISO 13909-5 to ascertain the correct sampling scheme.

b) Reference should be made to the equipment supplier’s operating and maintenance manual to

ascertain correct procedures for operation and intervals for routine maintenance. The manuals

can provide useful information based on the system design. Such information as conveyor rates,

conveyor speeds, material parameters (particularly sizing and variability) are significant data and

should always be kept in mind when any changes are contemplated.

c) Existing sampling and maintenance records for an extended period should be examined. This

information provides guidance for operators to ensure that the required level of inspection and

maintenance is carried out to ensure reliable operation and possibly to alert operators to any

inappropriate maintenance or modifications that can have been made to the equipment.

d) Personal experience of maintenance, operational and sampling personnel should be sought with

respect to the sampling system. This information, together with that obtained from items b) and

c), enable appropriate operators’ manual, operators’ sampling record and system checklist to be

prepared.
6.2 Audit — External

A scheme for regular audits of the sampling system should be established. Reference should be made

to the original operating parameters and equipment supplier's design data establish conformance with

the currently applicable International Standards.
NOTE Annex B provides a typical reference list.

It is recommended that correct operation of all new systems be confirmed by an audit following the

commissioning stage before being accepted as operational. Also, the design and operation of the system

should be confirmed by an audit prior to any bias test.
6.3 Audit — Internal

It is recommended that a scheme for routine inspections of the sampling system by operators should be

established. The frequency and detail of inspections is determined by such factors as, but not limited to,

reliability of the system, handling characteristics of the sampled material and frequency of use of the

system and purpose of sampling (e.g. process control compared to large multi-user port facilities).

6.4 Operational inspections

It is recommended that operational procedures and inspections should be established and carried out

immediately before, during and immediately after operation of the sampling system for a given lot

or sub-lot. These procedures and inspections are less extensive than those undertaken as audits or

mechanical inspections as given in 7.2 and 7.3. They should be designed to be simple inspections of the

integrity of the sampling process. For large, multi-user facilities, it is recommended that a system of

operational reports, as per the example in Annex B, be developed.
7 Procedures
7.1 Audit — External

When assessing the conformance of a mechanical sampling system, an auditor should refer to Annexes A

and B, the relevant parts of ISO 13909-2 and ISO 13909-5, and the design flow chart of the system

being evaluated. It is recommended that a person who is not directly involved in the operation and

management of that sampling system carry out an audit at least once per year.
© ISO 2019 – All rights reserved 3
---------------------- Page: 8 ----------------------
ISO 21398:2019(E)

It is recommended that reference be made to the original operational parameters upon which the

sampling system was designed. Operational conditions such as conveyor capacity, belt speed or material

top size may have been altered without due regard to the impact on the operation and conformity of the

sampling system.

The following are common examples of such alterations and their potential consequences.

— An increase in the capacity of a conveyor may result in excessive primary increment mass that can

no longer be entirely contained by the primary sample cutter.

— A change in conveyor speed may affect the trajectory of material at a transfer point, which may

result in a part of the material stream being missed by the sample cutter.

— A change in nominal top size of the coal or coke may result in the original cutter aperture no longer

being large enough (i.e. three times nominal top size of the mineral) to conform to the relevant parts

of ISO 13909.
Items that should be covered as a minimum are as follows:
a) safety requirements of site;
b) original and current operating parameters;
c) selection of appropriate sampling procedure;

d) general condition of the equipment, including build-up of material or blockages in chutes, cutters

and sample loss or sample contamination. Attention should be paid to wear items or corrosion that

can lead to moisture loss from air flow through the sampling system;

e) confirmation and comparison of design and actual increment masses for all cutters at several flow

rates on the product belt, up to the maximum;

f) condition of cutters, cutter apertures and cutter lips. Check for foreign material such as wood, rags,

stones and material that can be blinding the cutter apertures;

g) conformity to the relevant parts of ISO 13909. The following information should be referenced:

1) minimizing bias;
2) correct design and operation of sample cutters;
3) number of primary increments per lot or sub-lot required;

4) methods of taking primary, secondary or tertiary increments and the division of increments

and/or gross samples;

h) crusher inspection (inspect hammers or rolls and screens for wear and blinding);

i) determination of the top size of feed and crusher product;
j) staff training and procedures manual assessment;
k) check of previous mechanical inspections and operational inspections.
7.2 Audit — Internal

It is recommended that an experienced inspector should start at the primary cutter and follow through

the system to the final on-line sample collection point. The mechanical inspection should be made

both with and without coal or coke running through the system. Mechanical inspections should be

carried out at more frequent intervals than audits. For systems in daily use, it is recommended that the

management of the sampling system and not the direct operators of the system carry out mechanical

inspections at least once per month.
4 © ISO 2019 – All rights reserved
---------------------- Page: 9 ----------------------
ISO 21398:2019(E)
The following items should be inspected:

a) falling-stream and/or cross-belt cutter apertures, to determine that they comply with the

requirements of the relevant parts of ISO 13909 and with the design flow chart of the system;

b) speed in both directions of all cutters. For time-based sampling check that the speed is constant;

for mass-based sampling check that the speed is proportional to the flow rate to ensure that the

mass of increment is constant;
c) movement of all cutters to verify uniform speed while in the material stream;
d) that all cutters take a complete cross-section of material flow;

e) for all cutters, that the proper number of increments is taken to satisfy the requirements of

ISO 13909-2 and ISO 13909-5. It should also be verified that the time or mass interval between

primary cuts is correct to assure that the minimum number of increments is collected for the lot of

material being sampled during the inspection, based on maximum attainable feed rates;

f) that all cutters are parked out of the material stream in the at-rest position and that no coal or coke

is entering the cutter opening. There should be no holes in the baffle plates, dust doors or seals that

may cause leaking of material into the primary sample hopper. In the case of slotted-belt cutters,

checks should be undertaken to confirm the aperture size, cutter lips and belt speed;

g) masses of the sample increments for falling-stream and/or cross-belt cutters should confirm that

they conform to ISO 13909-2 and ISO 13909-5;

h) that the cycle time for all cutters, including dividers, should not be evenly divisible into the cycle

time of the previous division stage;

i) that belt feeders (sample conveyors) and vibrating feeders are in good condition. This is especially

important for sample integrity. The correct tracking of belts, condition of belts, skirt rubbers and

belt scrapers may have a significant impact on sample integrity. Check that the belt scrapers and

skirts are adjusted properly to avoid spillages. Check the flow rate settings of vibrating belt feeders;

j) the general condition of the crusher and the nominal top size of the crushed product. Variations in

product size over time may indicate that maintenance is required to screens, hammers in hammer-

mill crushers and rolls and gaps in roll crushers. Check that the crusher body and chutes are not

spilling material from the system;

k) final sample collector to determine general condition. Checks should be undertaken to ensure that

sample integrity is not being compromised through contamination, sample loss or total moisture loss;

l) records of previous operations and inspections.
7.3 Operational inspections

Operational inspections should be carried out immediately prior to, during and immediately after each

sampling operation. This falls due at changes of shift or material type, or for each lot. The emphasis of

operational inspections should be on ensuring that the sampling system is operated at correct settings

and that reliable operation is achieved during the sampling period. It is recommended that the direct

operators of the system carry out operational inspections. The following points should be checked and

reported:

a) that operational settings are correct, considering lot size, sub-lot size, time- or mass-based

sampling, number of primary, secondary and tertiary increments, division ratios and sample

collection interval;

b) that all equipment and sample chutes are clear of coal and coke build-up or blockages. Evidence of

chute damage due to damage to external walls or scraping should be recorded;
© ISO 2019 – All rights reserved 5
---------------------- Page: 10 ----------------------
ISO 21398:2019(E)

c) that all equipment and sample chutes are clear of foreign material such as wood, paper, rags, stones

or metal;

d) that all drives have been checked for correct operation, with attention paid to smooth operation of

sample cutter drives. Any unusual noises or vibrations should be reported;

e) that all drives, including hydraulic systems, have been started well before sampling is required.

Hydraulic systems may require a period of time to attain temperature equilibrium;

f) that the sampling system has been “conditioned” by passing one or more primary increments

through the sampling system before commencing or recommencing sampling. Any sample collected

during conditioning should be discarded;

g) that control charts have been maintained in accordance with Clause 8. This may provide evidence

of restricted flow through the system, if this occurs. An example of this may be found in Annex C.

8 Quality control
8.1 General

In addition to the operators’ sampling record, it is recommended that control charts also are maintained.

Two types of control charts are recommended, viz. for sampling ratio and extraction ratio.

8.2 Sampling ratio

The sampling ratio control chart is a plot of sampling ratio as a function of units sampled, where the

sampling ratio, F , is defined by Formula (1):
F =×1000 (1)
where
m is the mass of the sample, expressed in kilograms;
m is the mass of the material that the sample represents, expressed in tonnes.

Sampling ratio comparisons should be made only for like system settings (same cutter apertures, timer

settings, sub-lot size and mass flow rate through the system). Thus, a separate control chart is required

for each set of system settings used.

Samples having a sampling ratio out of the control range are suspect and should be investigated for

validity. When there is a significant variation in the sampling ratio, the reasons for this should be

investigated.

A detailed description of how to use control charts to monitor sampling ratios is provided in Annex A.

An example of sampling ratio charting is provided in Figure 1 and Table 1.

An example of an inspection summary and the associated sampling ratio control chart is shown in

Table 1 and Figure 1, respectively.
8.3 Coefficient of variation

After the sampling ratio is shown to be under control, it is good practice to monitor the percent

coefficient of variance (% CV) of the sampling ratio as an additional measure of whether the sampling

process is under control. See Annex A, Clause A.5, for instructions on how to calculate the % CV. A value

for the % CV of more than 15 % may indicate that system improvement is necessary.

6 © ISO 2019 – All rights reserved
---------------------- Page: 11 ----------------------
ISO 21398:2019(E)
8.4 Extraction ratio

The extraction ratio is the actual mass of the sample divided by the design mass of the sample expected

from the material flow rate, frequency of cuts, cutter aperture, cutter speed, etc.

The example shown in Figure 2 is calculated for a single lot. However, in practice, extraction ratio

control charts are constructed for multiple lots to indicate long-term trends. Thus, each point on an

extraction ratio control chart represents one sampled lot or the average of several sampled sub-lots.

The data are plotted over many lots and long-term trends for a system may be monitored. Contro

...

Questions, Comments and Discussion