Aluminium oxide used for the production of primary aluminium — Particle size analysis for the range 45 µm to 150 µm — Method using electroformed sieves

ISO 2926:2013 specifies a dry sieve method using electroformed sieves for determining the mass distribution of the particle sizes in aluminium oxide used for the production of primary aluminium. This method is applicable to calcined aluminium oxide containing a maximum of 20 % mass fraction of particles having a mean diameter exceeding 150 µm, and containing a maximum of 15 % mass fraction of particles having a mean diameter less than 45 µm. This method is not applicable to the use of woven wire sieves.

Oxyde d'aluminium utilisé pour la production d'aluminium primaire — Analyse granulométrique dans la gamme 45 µm à 150 µm — Méthode par emploi de tamis électroformés

General Information

Status
Published
Publication Date
13-Aug-2013
Current Stage
9020 - International Standard under periodical review
Start Date
15-Apr-2024
Completion Date
15-Apr-2024
Ref Project

Relations

Buy Standard

Standard
ISO 2926:2013 - Aluminium oxide used for the production of primary aluminium -- Particle size analysis for the range 45 µm to 150 µm -- Method using electroformed sieves
English language
10 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 2926
Third edition
2013-09-01
Aluminium oxide used for the
production of primary aluminium —
Particle size analysis for the range
45 µm to 150 µm — Method using
electroformed sieves
Oxyde d’aluminium utilisé pour la production d’aluminium
primaire — Analyse granulométrique dans la gamme 45 µm à 150
µm — Méthode par emploi de tamis électroformés
Reference number
ISO 2926:2013(E)
©
ISO 2013

---------------------- Page: 1 ----------------------
ISO 2926:2013(E)

COPYRIGHT PROTECTED DOCUMENT
© ISO 2013
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2013 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 2926:2013(E)

Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Principle . 1
4 Apparatus . 1
5 Procedure. 2
5.1 Sample preparation . 2
5.2 Preparation of test sieves . 2
5.3 Determination . 2
6 Calculation of results . 3
7 Test report . 3
8 Precision . 4
Annex A (informative) Example of calculation of size analysis . 5
Annex B (informative) Determination and use of effective aperture . 6
Annex C (informative) Results of interlaboratory test programme . 7
Annex D (informative) Ultrasonic cleaning of sieves
. 9
Bibliography .10
© I
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.