ISO/TS 17892-4:2004
(Main)Geotechnical investigation and testing — Laboratory testing of soil — Part 4: Determination of particle size distribution
Geotechnical investigation and testing — Laboratory testing of soil — Part 4: Determination of particle size distribution
ISO/TS 17892-4:2004 describes methods for the determination of the particle size distribution of soil samples. The particle size distribution is one of the most important physical characteristics of soil. Classification of soils is mainly based on the particle size distribution. Many geotechnical and geohydrological properties of soil are related to the particle size distribution. The particle size distribution provides a description of soil, based on a subdivision in discrete classes of particle sizes. The size of each class can be determined by sieving and/or sedimentation. For soils with less than 10 % fines, the sieving method is applicable. Soils with more than 10 % fines can be analysed by a combination of sieving and sedimentation. Sieving is the process whereby the soil is separated in particle size classes by the use of test sieves. Sedimentation is the process of the setting of soil particles in a liquid. The difference in settling rate enables the particle size classes to be separated. Two sedimentation methods are described; the hydrometer method and the pipette method. The methods described are applicable to all non-cemented soils with particle sizes less than 125 mm. Depending on the purpose for the determination of the particle size distribution, pretreatment or correction for calcium carbonate, dissolved salts and/or organic matter can be required. The use of these methods should be stated in the laboratory report. Modern methods that incorporate detection systems using x-rays, laser beams, density measurements and particle counters are not covered by this document.
Reconnaissance et essais géotechniques — Essais de laboratoire sur les sols — Partie 4: Détermination de la granulométrie
L'ISO 17892-4:2004 décrit des méthodes pour la détermination de la distribution granulométrique des particules d'échantillons de sol. La distribution granulométrique des particules est l'une des caractéristiques physiques les plus importantes pour la description d'un sol. La classification des sols est essentiellement basée sur elle. En outre, de nombreuses propriétés géotechniques et hydrogéologiques sont liées à la distribution granulométrique des particules. La distribution granulométrique des particules fournit une description du sol basée sur la subdivision en classes discrètes des dimensions des particules. La dimension de chacune de ces classes peut être déterminée par tamisage et/ou sédimentation. Le tamisage est applicable aux sols contenant moins de 10 % de fines. Les sols contenant plus de 10 % de fines peuvent être analysés en combinant tamisage et sédimentation. Le tamisage est un procédé par lequel le sol est séparé en classes de dimension des particules au moyen de tamis d'essai. La sédimentation est un procédé dans lequel le sol est mis en suspension dans un liquide. La différence des vitesses de dépôt permet de séparer les particules en classes de dimension différente. Deux méthodes de sédimentation sont décrites: la méthode du densimètre et celle de la pipette. Les méthodes décrites dans ce document peuvent être appliquées à tous les sols non cimentés dont les particules ont une dimension inférieure à 125 mm. En fonction du but poursuivi par l'analyse granulométrique, un prétraitement ou une correction peuvent s'avérer nécessaires pour les carbonates de calcium, les sels dissous et/ou la matière organique. Il convient de signaler l'utilisation de ces méthodes dans le rapport d'essai. Les méthodes modernes utilisant les rayons X, un faisceau laser, le mesurage de la masse volumique et le comptage des particules ne sont pas prises en considération dans le présent document.
General Information
Relations
Buy Standard
Standards Content (Sample)
TECHNICAL ISO/TS
SPECIFICATION 17892-4
First edition
2004-10-15
Geotechnical investigation and testing —
Laboratory testing of soil —
Part 4:
Determination of particle size distribution
Reconnaissance et essais géotechniques — Essais de sol au
laboratoire —
Partie 4: Détermination de la granulométrie
Reference number
ISO/TS 17892-4:2004(E)
©
ISO 2004
---------------------- Page: 1 ----------------------
ISO/TS 17892-4:2004(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2004
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2004 – All rights reserved
---------------------- Page: 2 ----------------------
ISO/TS 17892-4:2004(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
In other circumstances, particularly when there is an urgent market requirement for such documents, a
technical committee may decide to publish other types of normative document:
— an ISO Publicly Available Specification (ISO/PAS) represents an agreement between technical experts in
an ISO working group and is accepted for publication if it is approved by more than 50 % of the members
of the parent committee casting a vote;
— an ISO Technical Specification (ISO/TS) represents an agreement between the members of a technical
committee and is accepted for publication if it is approved by 2/3 of the members of the committee casting
a vote.
An ISO/PAS or ISO/TS is reviewed after three years with a view to deciding whether it should be confirmed for
a further three years, revised to become an International Standard, or withdrawn. In the case of a confirmed
ISO/PAS or ISO/TS, it is reviewed again after six years at which time it has to be either transposed into an
International Standard or withdrawn.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO/TS 17892-4 was prepared by the European Committee for Standardization (CEN) in collaboration with
Technical Committee ISO/TC 182, Geotechnics, Subcommittee SC 1, Geotechnical investigation and testing,
in accordance with the Agreement on technical cooperation between ISO and CEN (Vienna Agreement).
Throughout the text of this document, read ".this European pre-Standard." to mean ".this Technical
Specification.".
ISO 17892 consists of the following parts, under the general title Geotechnical investigation and testing —
Laboratory testing of soil:
Part 1: Determination of water content
Part 2: Determination of density of fine-grained soil
Part 3: Determination of particle density — Pycnometer method
Part 4: Determination of particle size distribution
Part 5: Incremental loading oedometer test
Part 6: Fall cone test
© ISO 2004 – All rights reserved iii
---------------------- Page: 3 ----------------------
ISO/TS 17892-4:2004(E)
Part 7: Unconfined compression test on fine-grained soil
Part 8: Unconsolidated undrained triaxial test
Part 9: Consolidated triaxial compression tests on water-saturated soil
Part 10: Direct shear tests
Part 11: Determination of permeability by constant and falling head
Part 12: Determination of the Atterberg limits
iv © ISO 2004 – All rights reserved
---------------------- Page: 4 ----------------------
ISO/TS 17892-4:2004(E)
Page
Contents
Foreword.vi
1 Scope .1
2 Normative references .1
3 Terms and definitions .2
4 Equipment .2
5 Test procedure.6
6 Test results.17
7 Test report .20
Annex A (informative) Calibration of hydrometer .22
Annex B (informative) Calibration of hydrometer .25
Bibliography .26
Tables
Table 1 — Minimum mass required for sieving as a function of particle diameter D .8
90
Table 2 — Maximum mass of soil retained on each sieve.10
Table 3 — Dry mass of soil specimen for sedimentation test.13
Table 4 — Insertion depth of pipette.16
Table 5 — Dynamic viscosity of water.19
Table A.1 — Temperature correction.24
Figures
Figure 1 — Example of pipette configuration .5
Figure 2 — Sieving procedure.7
Figure 3 — General procedure for sedimentation .12
Figure 4 — Example of a particle size distribution result.21
Figure A.1 — Example of calibration of hydrometer scale .23
© ISO 2004 – All rights reserved v
---------------------- Page: 5 ----------------------
ISO/TS 17892-4:2004(E)
Foreword
This document (CEN ISO/TS 17892-4:2004) has been prepared by Technical Committee CEN/TC 341
“Geotechnical investigation and testing”, the secretariat of which is held by DIN, in collaboration with Technical
Committee ISO/TC 182 “Geotechnics”.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to announce this Technical Specification: Austria, Belgium, Cyprus, Czech Republic, Denmark,
Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
CEN ISO/TS 17892 consists of the following parts, under the general title Geotechnical investigation and testing —
Laboratory testing of soil:
Part 1: Determination of water content
Part 2: Determination of density of fine-grained soil
Part 3: Determination of particle density — Pycnometer method
Part 4: Determination of particle size distribution
Part 5: Incremental loading oedometer test
Part 6: Fall cone test
Part 7: Unconfined compression test on fine-grain soil
Part 8: Unconsolidated undrained triaxial test
Part 9: Consolidated triaxial compression tests on water-saturated soil
Part 10: Direct shear tests
Part 11: Determination of permeability by constant and falling head
Part 12: Determination of the Atterberg limits
vi © ISO 2004 – All rights reserved
---------------------- Page: 6 ----------------------
ISO/TS 17892-4:2004(E)
Introduction
This document covers areas in the international field of geotechnical engineering never previously standardised. It
is intended that this document presents broad good practice throughout the world and significant differences with
national documents is not anticipated. It is based on international practice (see [1]).
© ISO 2004 – All rights reserved vii
---------------------- Page: 7 ----------------------
ISO/TS 17892-4:2004(E)
1 Scope
This document describes methods for the determination of the particle size distribution of soil samples.
The particle size distribution is one of the most important physical characteristics of soil. Classification of soils is
mainly based on the particle size distribution. Many geotechnical and geohydrological properties of soil are related
to the particle size distribution.
The particle size distribution provides a description of soil, based on a subdivision in discrete classes of particle
sizes. The size of each class can be determined by sieving and/or sedimentation. For soils with less than 10 %
fines, the sieving method is applicable. Soils with more than 10 % fines can be analysed by a combination of
sieving and sedimentation.
Sieving is the process whereby the soil is separated in particle size classes by the use of test sieves.
Sedimentation is the process of the setting of soil particles in a liquid. The difference in settling rate enables the
particle size classes to be separated. Two sedimentation methods are described; the hydrometer method and the
pipette method.
The methods described are applicable to all non-cemented soils with particle sizes less than 125 mm.
Depending on the purpose for the determination of the particle size distribution, pretreatment or correction for
calcium carbonate, dissolved salts and/or organic matter can be required. The use of these methods should be
stated in the laboratory report.
Modern methods that incorporate detection systems using x-rays, laser beams, density measurements and particle
counters are not covered by this document.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references,
only the edition cited applies. For undated references, the latest edition of the referenced document (including any
amendments) applies.
CEN ISO/TS 17892-1, Geotechnical investigation and testing — Laboratory testing of soil — Part 1: Determination
of water content (ISO/TS 17892-1:2004).
CEN ISO/TS 17892-3, Geotechnical investigation and testing — Laboratory testing of soil — Part 3: Determination
of particle density — Pycnometer method (ISO/TS 17892-3:2004).
ISO 565, Test sieves - Metal wire cloth, perforated metal plate and electroformed sheet - Nominal sizes of
openings.
ISO 3310-1, Test sieves - Technical requirements and testing - Part 1: Test sieves of metal wire cloth.
ISO 3310-2, Test sieves - Technical requirements and testing - Part 2: Test sieves of perforated metal plate.
© ISO 2004 – All rights reserved 1
---------------------- Page: 8 ----------------------
ISO/TS 17892-4:2004(E)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
particle size distribution
proportions by mass of the various particle size classes present in a specific soil
3.2
equivalent diameter
particle diameter calculated from sedimentation data using Stoke's law, and assuming spherical particles
3.3
coarse-grained cohesionless soils
soils comprising gravel and/or sand sizes particles with less than about 10 % of fines, and which are virtually non-
cohesive
NOTE The fines content is measured only quantitatively, by difference after washing the material away.
3.4
fine-grained soils
soils comprising more than about 10 % of fines, sometimes with sand but with little or no gravel-sized particles.
This category includes both non-cohesive and cohesive soils
3.5
mixed soils
soils comprising gravel, sand, and more than about 10 % of fines
NOTE These soils may or may not be cohesive, depending on the amount of clay present.
3.6
fines
particles passing the 0,063 mm sieve
3.7
D
90
the smallest sieve mesh aperture through which 90 % or more of the particles will pass
4 Equipment
4.1 General
4.1.1 Balances
Balances shall have an accuracy of 0,3 % of the total dry specimen mass and a readability of 0,1 % of total dry
specimen mass.
4.1.2 Drying ovens
Drying ovens shall be capable of maintaining a temperature of 105 °C ± 5 °C and 50 °C ± 5 °C.
4.1.3 Desiccator
Desiccator shall contain anhydrous silica gel.
WARNING — Traditional blue self-indicating silica gel contains cobalt chloride which has been reclassified
as potential carcinogen by inhalation by EU Directive 98/98/EC.
2 © ISO 2004 – All rights reserved
---------------------- Page: 9 ----------------------
ISO/TS 17892-4:2004(E)
4.1.4 Evaporating dish
Evaporating dish shall be made of porcelain or non-corroding metal, having a minimum content of 100 ml.
4.1.5 Sieves
Sieves shall comprise a sieve of 0,063 mm, suitably reinforced for use as a washing sieve, with receiver, and one
sieve of 2,0 mm.
4.2 Sieving
4.2.1 Test sieves
Test sieves of metal wire cloth or perforated metal plate in accordance with ISO 565 and ISO 3310, together with
appropriate receivers shall be used.
The aperture of the test sieves should adequately cover the range for the particular soil tested, but it is
recommended that within the full range of 125 mm to 0,063 mm not less than 12 sieves are used. The smallest test
sieve should have an aperture of 0,063 mm. The number of sieves used shall be sufficient to ensure that any
discontinuities in the grading curve are detected. The test sieves should be visually checked before every use.
4.2.2 Ancillary apparatus
The ancillary apparatus shall consist of
corrosion resistant trays;
large corrosion resistant or plastic tray or bucket;
scoop;
sieve brushes;
rubber tubing;
cylindrical beaker, 800 ml or more;
riffle box (optional);
mechanical sieve shaker (optional).
4.3 Hydrometer method
4.3.1 Hydrometer
The hydrometer shall be torpedo-shaped and made of glass as free as possible from visible defects. The glass
shall be resistant to chemicals and well annealed. The hydrometer stem and bulb shall be circular in cross section
and symmetrical around the main axis, without abrupt change in cross section. The hydrometer shall always float,
at all points within its range, within the stem within 1,5° of the vertical. The scale and inscription shall be marked
clearly and permanently, showing no apparent irregularities in spacing. The graduation lines shall be at intervals of
0,0005 g/ml and the range of the hydrometer shall be between 0,9950 g/ml and 1,0300 g/ml. The hydrometer shall
be indelibly marked with a unique identification number.
4.3.2 Graduated glass cylinders
Graduated glass cylinders shall be provided with parallel sides and with constant cross sectional area across their
length. The diameter shall be at least twice that of the hydrometer bulb and the length be sufficient to ensure that
the hydrometer can float freely in 1000 ml of pure water.
© ISO 2004 – All rights reserved 3
---------------------- Page: 10 ----------------------
ISO/TS 17892-4:2004(E)
4.3.3 Thermometers
Thermometer shall cover a temperature range of 0 °C to 50 °C and be accurate to 0,5 °C.
4.3.4 Water bath
The water bath shall be insulated and may have a temperature controller.
4.3.5 Mechanical shaker or mixer
The mechanical shaker or mixer shall be capable of keeping the appropriate quantities of soil and water in
continuous suspension.
4.3.6 Timer
The stop watch or stop clock shall be readable to 1 s.
4.3.7 Working bench
1)
The working bench shall be free from vibrations.
4.3.8 Centrifuge
The centrifuge or vacuum filter and ancillaries, or any other apparatus shall be suitable for separating out the soil
particles following pretreatment for the removal of salts, organic and/or calcareous matter (optional).
4.4 Pipette method
4.4.1 Pipette
The pipette shall be calibrated. It shall have a volume of 20 ml and be mounted in a pipette configuration (Figure 1).
1) Free from vibrations means no ripples can be seen on the surface of a suspension placed on the working bench.
4 © ISO 2004 – All rights reserved
---------------------- Page: 11 ----------------------
ISO/TS 17892-4:2004(E)
Key
1 Bulb
2 Stop cock
3 Safety bulb suction inlet
4 Safety bulb
5 Three-way stop cock
6 Outlet tube
7 Sampling pipette
8 Sedimentation cylinder
9 Graduated scale
10 Sliding panel
11 Clamps
Figure 1 — Example of pipette configuration
4.4.2 Balance
The balance shall have an accuracy of 0,3 mg.
4.4.3 Thermometers
Thermometers shall cover a temperature range of 0 °C to 50 °C and be accurate to 0,5 °C.
4.4.4 Water bath
The water bath shall be insulated and may have a temperature controller.
4.4.5 Mechanical shaker or mixer
The mechanical shaker or mixer shall be capable of keeping the appropriate quantities of soil and water in
continuous suspension.
4.4.6 Timer
A stop watch or stop clock shall be readable to 1 s.
4.4.7 Working bench
a)
The working bench shall be free from vibrations.
4.4.8 Centrifuge
The centrifuge or vacuum filter and ancillaries, or any other apparatus shall be suitable for separating out the soil
particles following pretreatment for the removal of salts, organic and/or calcareous matter (optional).
© ISO 2004 – All rights reserved 5
---------------------- Page: 12 ----------------------
ISO/TS 17892-4:2004(E)
4.5 Reagents
4.5.1 General
Reagents shall be of analysis quality.
4.5.2 Water
The water shall be distilled, de-ionised or demineralised.
4.5.3 Dispersing agent
The dispersing agent may be water. However, if flocculation occurs, this can be prevented by adding a dispersing
agent. Options include but are not limited to:
Sieving: sodium hexametaphosphate, approximately 2 g/l or sodium pyrophosphate, approximately 2 g/l;
Sedimentation: sodium hexametaphosphate approximately 40 g/l (0,07 M) or sodium pyrophosphate, approxi-
mately 20 g/l (0,07 M).
Solutions shall be renewed monthly. Sodium carbonate shall not be added to the sodium hexametaphosphate.
4.5.4 Hydrogen peroxide
Hydrogen peroxide (20% V/V) may be used to remove organic material.
4.5.5 Hydrochlorid acid
Hydrochlorid acid (0,2 M (± 1 %)) may be used to remove carbonates (optional).
5 Test procedure
5.1 Selection of test method
The test method shall be selected as follows:
For mixed soils separate sieving and sedimentation shall be performed.
If 90 % or more of the particles are larger than 0,063 mm sieving shall be performed.
If more than 10 % of the particles are smaller than 0,063 mm sedimentation shall be performed.
If the complete curve of the grain size distribution is required, sieving and sedimentation test shall be carried out.
5.2 Sieving
5.2.1 General
5.2.1.1 The general procedure for sieving is outlined in Figure 2.
6 © ISO 2004 – All rights reserved
---------------------- Page: 13 ----------------------
ISO/TS 17892-4:2004(E)
Key
1 Sample
2 Riffling or quartering
3 Drying
4 Weighing
5 Stirring
6 Separating
7 Drying
8 Dry separation (alternative method)
9 Sieving
10 Weighing
11 Computation
a Dispersing agent
b Clear water
Figure 2 — Sieving procedure
© ISO 2004 – All rights reserved 7
---------------------- Page: 14 ----------------------
ISO/TS 17892-4:2004(E)
5.2.1.2 Sieves shall be regularly checked for compliance with ISO 3310-1 and ISO 3310-2.
5.2.1.3 The oven temperature shall be verified at least every two years by means of a calibrated temperature
measuring device.
5.2.1.4 Oven-drying shall be done at 105 °C ± 5 °C, unless the soil is susceptible to heating. Susceptible soils
shall be dried at 50 °C.
NOTE Soils susceptible to heating include organic soils, gypsum and laterite.
5.2.2 Specimen preparation
5.2.2.1 Wet preparation should be used.
For soils containing more than 10 % fines, use of the dry preparation method may introduce significant errors.
5.2.2.6 to 5.2.2.8 is only applicable to wet preparation.
5.2.2.2 A representative specimen shall be prepared by riffling or quartering, and oven-drying. Minimum masses
for dried specimens required for testing are given in Table 1. If it is found that the amount of soil is not sufficient to
comply this fact shall be reported.
Table 1 — Minimum mass required for sieving as a function of particle diameter D
90
Particle diameter Minimum mass required for sieving
D
90
mm g
0,5 50
1,0 100
4,0 150
6,0 350
8,0 600
16,0 2500
22,4 5000
31,5 10000
45,0 20000
63,0 40000
75,0 56000
8 © ISO 2004 – All rights reserved
---------------------- Page: 15 ----------------------
ISO/TS 17892-4:2004(E)
5.2.2.3 If sedimentation is also required, this shall be done using a separate specimen, which is not oven-dried.
5.2.2.4 Soils may be pretreated prior to sieving to remove dissolved salts, organic and/or calcareous matter if
required. The method shall be stated on the test report together with the amount of material removed. A suggested
method for pretreatment for organic and carbonate material is included in annex B.
5.2.2.5 The dry specimen shall be weighed to the nearest 0,1 % of the total dry mass (m).
5.2.2.6 The specimen shall be placed in a tray or bucket and covered with water. It shall stand for a minimum of
1 hour and be stirred frequently.
For specimens with particles with diameter above 5 mm, it may be necessary to split the sample on a suitable
sieve, and treat the coarse fraction separately. If necessary the mass of the fraction passing the sieve shall be
reduced by riffling.
It may be necessary to soak the specimen in dispersing agent to remove interstitial clay.
5.2.2.7 The specimen shall be washed through a 2 mm sieve nested in a 0,063 mm sieve until the water runs
virtually clear. Ensure that neither sieve becomes overloaded. Material passing the sieves can be collected if
required.
5.2.2.8 All material retained on the sieves shall be transferred, oven-dried, and weighed to the nearest 0,1 % of
the total dry mass of the specimen.
5.2.3 Test execution
5.2.3.1 The dried material shall be sieved down to 0,063 mm, weighing the soil retained on each test sieve, and
any material passing the 0,063 mm sieve. The masses retained on each sieve shall not exceed the values listed in
Table 2.
When a sieving machine is used, sieving should be continued for at least 10 min. When hand sieving is used, the
sieve should be shaken for at least 2 min, and then until no more material passes.
When the maximum mass listed in Table 2 is exceeded, the sieving shall be performed in stages. The soil on the
first sieve exceeding the maximum amount is split in smaller portions which are then sieved separately. The total
mass on each sieve is calculated from the sum of masses retained from each portion.
5.2.3.2 For each sieving sequence, the cumulative mass retained on each sieve and the fraction passing the
last sieve shall be calculated. If this differs from the mass at the start of sieving by more than 1 %, the sieving shall
be repeated.
© ISO 2004 – All rights reserved 9
---------------------- Page: 16 ----------------------
ISO/TS 17892-4:2004(E)
10 © ISO 2004 – All rights reserved
Table 2 — Maximum mass of soil retained on each sieve
Maximum mass on sieve
Maximum mass on sieve of diameter
of diameter
Nominal opening Nominal mesh size
450 mm 300 mm 200 mm
mass mass mass
mm kg kg mm g
5,0 1 0,50 0,038 20
5,6 1 0,50 0,063 25
6,3 1,5 0,75 0,125 35
8,0 1,7 0,9 0,150 40
10,0 2,0 1,0 0,212 50
11,2 2,2 1,2 0,250 50
14,0 3,0 1,5 0,300 50
16,0 3,5 1,7 0,355 60
20,0 4,0 2,0 0,425 75
22,4 4,5 2,2 0,500 70
28,0 6,0 2,5 0,600 75
31,5 6,5 3,0 0,710 80
37,5 8,0 3,5 1,18 100
45,0 9,0 4,0 1,4 125
50,0 10,0 4,5 2,0 200
63,0 11,0 5,0 3,35 300
4,0 300
---------------------- Page: 17 ----------------------
ISO/TS 17892-4:2004(E)
5.3 Hydrometer analysis
5.3.1 General
5.3.1.1 The general procedure for hydrometer analysis is outlined in Figure 3.
© ISO 2004 – All rights reserved 11
---------------------- Page: 18 ----------------------
ISO/TS 17892-4:2004(E)
Key
1 sample
2 quartering
3 weighing
4 drying
5 stirring
6 separating
7 drying
8 evaporation and decantation
9 sieving
10 weighing
11 agitation
12 sedimentation
13 computation
a dispersant
b water content
c evaporating dish
Figure 3 — General procedure for sedimentation
12 © ISO 2004 – All rights reserved
---------------------- Page: 19 ----------------------
ISO/TS 17892-4:2004(E)
5.3.1.2 The oven temperature shall be verified at least every two years by means of a calibrated temperature
measuring device.
5.3.1.3 The temperature shall be kept constant for the duration of the test. The test may be performed in a
temperature-conditioned room, in an insulated water bath or in a constant temperature bath. The temperature
fluctuation during the test should not exceeded 0,5 °C, the temperature itself falling within the range of 15 °C to
25 °C.
5.3.1.4 Oven-drying shall be done at 105 °C ± 5°C, unless the soil is susceptible to heating. Susceptible soils
shall be dried at 50 °C.
5.3.1.5 For test carried in a temperature-conditioned room, a calibrated temperature measuring device shall be
placed permanently in the room to provide a continuous temperature record.
5.3.1.6 If a constant temperature bath is used, care shall be taken that its agitator does not introduce vibrations
in the specimen.
5.3.1.7 Calibration of the hydrometer shall be performed prior to its first use. Corrections may be applied
individually or combined, but the following points should always be taken into account:
volume and geometry;
scale calibration;
meniscus correction;
temperature correction, if necessary;
dispersing agent correction.
A method for determining these corrections is described in annex A.
5.3.2 Specimen preparation
5.3.2.1 A specimen of non-dried soil shall be selected in accordance with Table 3.
Table 3 — Dry mass of soil specimen for sedimentation test
Dry mass of soil
Soil type
g
Soil containing sand up to 75
Cohesive soils, with little or no sand 30 to 50
Very plastic to plastic clays 10 to 30
5.3.2.2 The water content of the soil shall be determined on a separate specimen according to CEN ISO/TS
17892-1 .
5.3.2.3 The density of solid particles, when required, shall be determined on a separate specimen in accordance
with CEN ISO/TS 17892-3.
NOTE The density of solid particles is needed for the calculation of equivalent particle diameters and corresponding fractions.
© ISO 2004 – All rights reserved 13
---------------------- Page: 20 --------------------
...
SPÉCIFICATION ISO/TS
TECHNIQUE 17892-4
Première édition
2004-10-15
Reconnaissance et essais
géotechniques — Essais de sol au
laboratoire —
Partie 4:
Détermination de la granulométrie
Geotechnical investigation and testing — Laboratory testing of soil —
Part 4: Determination of particle size distribution
Numéro de référence
ISO/TS 17892-4:2004(F)
©
ISO 2004
---------------------- Page: 1 ----------------------
ISO/TS 17892-4:2004(F)
PDF – Exonération de responsabilité
Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier
peut être imprimé ou visualisé, mais ne doit pas être modifié à moins que l'ordinateur employé à cet effet ne bénéficie d'une licence
autorisant l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées
acceptent de fait la responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute
responsabilité en la matière.
Adobe est une marque déposée d'Adobe Systems Incorporated.
Les détails relatifs aux produits logiciels utilisés pour la création du présent fichier PDF sont disponibles dans la rubrique General Info
du fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir
l'exploitation de ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation,
veuillez en informer le Secrétariat central à l'adresse donnée ci-dessous.
© ISO 2004
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous
quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit
de l'ISO à l'adresse ci-après ou du comité membre de l'ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax. + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse
ii © ISO 2004 – Tous droits réservés
---------------------- Page: 2 ----------------------
ISO/TS 17892-4:2004(F)
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée
aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du
comité technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec
la Commission électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI,
Partie 2.
La tâche principale des comités techniques est d'élaborer les Normes internationales. Les projets de Normes
internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur
publication comme Normes internationales requiert l'approbation de 75 % au moins des comités membres
votants.
Dans d'autres circonstances, en particulier lorsqu'il existe une demande urgente du marché, un comité
technique peut décider de publier d'autres types de documents normatifs:
— une Spécification publiquement disponible ISO (ISO/PAS) représente un accord entre les experts dans
un groupe de travail ISO et est acceptée pour publication si elle est approuvée par plus de 50 % des
membres votants du comité dont relève le groupe de travail;
— une Spécification technique ISO (ISO/TS) représente un accord entre les membres d'un comité technique
et est acceptée pour publication si elle est approuvée par 2/3 des membres votants du comité.
Une ISO/PAS ou ISO/TS fait l'objet d'un examen après trois ans afin de décider si elle est confirmée pour trois
nouvelles années, révisée pour devenir une Norme internationale, ou annulée. Lorsqu'une ISO/PAS ou
ISO/TS a été confirmée, elle fait l'objet d'un nouvel examen après trois ans qui décidera soit de sa
transformation en Norme internationale soit de son annulation.
L'attention est appelée sur le fait que certains des éléments du présent document peuvent faire l'objet de
droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable de ne
pas avoir identifié de tels droits de propriété et averti de leur existence.
L'ISO/TS 17892-4 a été élaborée par le Comité européen de normalisation (CEN) en collaboration avec le
comité technique ISO/TC 182, Géotechnique, sous-comité SC 1, Recherches et essais géotechniques,
conformément à l'Accord de coopération technique entre l'ISO et le CEN (Accord de Vienne).
Tout au long du texte du présent document, lire «… la présente prénorme européenne …» avec le sens de
«… la présente Spécification technique …».
L'ISO/TS 17892 comprend les parties suivantes, présentées sous le titre général Reconnaissance et essais
géotechniques — Essais de sol au laboratoire:
— Partie 1: Détermination de la teneur en eau
— Partie 2: Détermination de la masse volumique d'un sol fin
— Partie 3: Détermination de la masse volumique des grains — Méthode du pycnomètre
— Partie 4: Détermination de la granulométrie
— Partie 5: Essai à l'oedomètre sur sol saturé
© ISO 2004 – Tous droits réservés iii
---------------------- Page: 3 ----------------------
ISO/TS 17892-4:2004(F)
— Partie 6: Essai au cône
— Partie 7: Essai de compression simple sur sol cohérent
— Partie 8: Essai triaxial non consolidé non drainé
— Partie 9: Essai triaxial consolidé sur sol saturé
— Partie 10: Essai de cisaillement direct
— Partie 11: Détermination de la perméabilité au perméamètre à charge constante ou variable
— Partie 12: Détermination des limites d'Atterberg
iv © ISO 2004 – Tous droits réservés
---------------------- Page: 4 ----------------------
ISO/TS 17892-4:2004(F)
Sommaire Page
Avant-propos .vii
Introduction.viii
1 Domaine d’application .1
2 Références normatives .1
3 Termes et définitions.2
4 Appareillage.2
Généralités.2
4.1
4.2 Tamisage .3
4.3 Méthode du densimètre .4
4.4 Méthode de la pipette.4
4.5 Réactifs.6
5 Procédures d’essai.6
5.1 Sélection de la méthode d’essai.6
5.2 Tamisage .7
5.3 Analyse au densimètre.12
5.4 Méthode de la pipette.16
6 Résultats d’essais .18
6.1 Tamisage .18
Densimètre.18
6.2
6.3 Méthode de la pipette.21
7 Rapport d’essai .22
Annexe A (informative) Étalonnage du densimètre.23
A.1 Étalonnage du volume .23
A.2 Étalonnage de l’échelle.23
A.3 Correction due au ménisque.24
A.4 Correction due à la température.25
A.5 Correction due à l’agent dispersant .25
A.6 Tube cylindrique de sédimentation .25
Annexe B (informative) Prétraitement en présence de matière organique et de carbonates.26
B.1 Prétraitement en présence de matière organique.26
B.2 Prétraitement en présence de carbonates .26
B.3 Étape finale du prétraitement.26
Bibliographie.27
Tableaux
Tableau 1 — Masses minimales requises pour le tamisage, en fonction du diamètre des
particules D .9
90
Tableau 2 — Masses maximales de sol retenues sur chaque tamis .11
Tableau 3 — Masse sèche d’une éprouvette de sol pour l’essai de sédimentation .14
Tableau 4 — Profondeur d’insertion de la pipette.17
Tableau 5 — Viscosité dynamique de l’eau .20
Tableau A.1 — Correction due à la température.25
© ISO 2004 – Tous droits réservés v
---------------------- Page: 5 ----------------------
ISO/TS 17892-4:2004(F)
Figures
Figure 1 — Exemple de configuration de pipette. 5
Figure 2 — Mode opératoire pour le tamisage. 9
Figure 3 — Mode opératoire général pour la sédimentation. 13
Figure 4 — Exemple de résultats d’une distribution granulométrique des particules. 22
Figure A.1 — Exemple d’étalonnage de l’échelle du densimètre. 24
vi © ISO 2004 – Tous droits réservés
---------------------- Page: 6 ----------------------
ISO/TS 17892-4:2004(F)
Avant-propos
Le présent document CEN ISO/TS 17892-4:2004 a été élaboré par le Comité Technique CEN/TC 341
“Reconnaissance et essais géotechniques”, dont le secrétariat est tenu par DIN, en collaboration avec le
Comité Technique ISO/TC 182 “Géotechnique”.
Selon le Règlement Intérieur du CEN/CENELEC, les instituts de normalisation nationaux des pays suivants
sont tenus d’annoncer cette Spécification technique : Allemagne, Autriche, Belgique, Chypre, Danemark,
Espagne, Estonie, Finlande, France, Grèce, Hongrie, Irlande, Islande, Italie, Lettonie, Lituanie, Luxembourg,
Malte, Norvège, Pays-Bas, Pologne, Portugal, République Tchèque, Royaume-Uni, Slovaquie, Slovénie,
Suède et Suisse.
CEN ISO/TS 17892 comporte plusieurs parties, sous le titre général «Reconnaissance et essais
géotechniques — Essai de laboratoire sur les sols» :
Partie 1 : Détermination de la teneur en eau
Partie 2 : Détermination de la masse volumique d’un sol fin
Partie 3 : Détermination de la masse volumique des particules solides — Méthode du pycnomètre
Partie 4 : Détermination de la distribution granulométrique des particules
Partie 5 : Essai de chargement par paliers à l’œdomètre
Partie 6 : Essai de pénétration de cône
Partie 7 : Essai de compression uniaxiale sur des sols fins
Partie 8 : Essai triaxial non consolidé et non drainé
Partie 9 : Essai en compression à l'appareil triaxial sur des sols saturés consolidés
Partie 10 : Essais de cisaillement direct
Partie 11 : Essais de perméabilité à charge variable décroissante
Partie 12 : Détermination des limites Atterberg
© ISO 2004 – Tous droits réservés vii
---------------------- Page: 7 ----------------------
ISO/TS 17892-4:2004(F)
Introduction
Le présent document couvre des sujets n’ayant jusqu’alors pas été normalisés au niveau international dans le
domaine de la géotechnique. L’objectif du document est de présenter la pratique généralement appliquée
dans le monde entier et il n’est pas indiqué les différences significatives avec les documents nationaux. Il
s’appuie sur la pratique internationale (voir [1]).
viii © ISO 2004 – Tous droits réservés
---------------------- Page: 8 ----------------------
ISO/TS 17892-4:2004(F)
1 Domaine d’application
Le présent document décrit des méthodes pour la détermination de la distribution granulométrique des
particules d’échantillons de sol.
La distribution granulométrique des particules est l’une des caractéristiques physiques les plus importantes
pour la description d’un sol. La classification des sols est essentiellement basée sur elle. En outre, de
nombreuses propriétés géotechniques et hydrogéologiques sont liées à la distribution granulométrique des
particules.
La distribution granulométrique des particules fournit une description du sol basée sur la subdivision en
classes discrètes des dimensions des particules. La dimension de chacune de ces classes peut être
déterminée par tamisage et/ou sédimentation. Le tamisage est applicable aux sols contenant moins de 10 %
de fines. Les sols contenant plus de 10 % de fines peuvent être analysés en combinant tamisage et
sédimentation.
Le tamisage est un procédé par lequel le sol est séparé en classes de dimension des particules au moyen de
tamis d’essai. La sédimentation est un procédé dans lequel le sol est mis en suspension dans un liquide. La
différence des vitesses de dépôt permet de séparer les particules en classes de dimension différente. Deux
méthodes de sédimentation sont décrites : la méthode du densimètre et celle de la pipette.
Les méthodes décrites dans ce document peuvent être appliquées à tous les sols non cimentés dont les
particules ont une dimension inférieure à 125 mm.
En fonction du but poursuivi par l’analyse granulométrique, un prétraitement ou une correction peuvent
s’avérer nécessaires pour les carbonates de calcium, les sels dissous et/ou la matière organique. Il convient
de signaler l’utilisation de ces méthodes dans le rapport d’essai.
Les méthodes modernes utilisant les rayons X, un faisceau laser, le mesurage de la masse volumique et le
comptage des particules ne sont pas prises en considération dans le présent document.
2 Références normatives
Les documents de référence suivants sont indispensables pour l’application du présent document. Pour les
références datées, seule l’édition citée s’applique. Pour les références non datées, la dernière édition du
document de référence (y compris les amendements) s’applique.
CEN ISO/TS 17892-1, Reconnaissance et essais géotechniques — Essais de laboratoire sur les sols —
Partie 1 : Détermination de la teneur en eau. (ISO/TS 17892-1:2004)
CEN ISO/TS 17892-3, Reconnaissance et essais géotechniques — Essais de laboratoire sur les sols —
Partie 3 : Détermination de la masse volumique des particules solides — Méthode du pycnomètre.
(ISO/TS 17892-3:2004).
ISO 565, Tamis de contrôle — Tissus métalliques, tôles métalliques perforées et feuilles électroformées —
Dimensions nominales des ouvertures.
ISO 3310-1, Tamis de contrôle — Exigences techniques et vérifications — Partie 1 : Tamis de contrôle en
tissus métalliques.
ISO 3310-2, Tamis de contrôle — Exigences techniques et vérifications — Partie 2 : Tamis de contrôle en
tôles métalliques perforées.
© ISO 2004 – Tous droits réservés 1
---------------------- Page: 9 ----------------------
ISO/TS 17892-4:2004(F)
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions suivants s’appliquent.
3.1
granularité
pourcentage massique des différentes classes granulométriques présentes dans un sol particulier
3.2
diamètre équivalent
diamètre d’un grain calculé sur la base des résultats de sédimentation en appliquant la loi de Stokes et en
prenant pour hypothèse que les particules sont sphériques
3.3
sols grenus non cohérents
sols comprenant du gravier et/ou du sable avec moins de 10 % de fines, et ne présentant pratiquement pas
de cohésion
NOTE La teneur en fines est mesurée uniquement quantitativement, à partir de la différence après lavage du
matériau.
3.4
sols fins
sols contenant plus de 10 % de fines, quelquefois avec du sable mais avec très peu ou pas de gravier. Cette
catégorie inclut des sols cohérents ou non
3.5
sols mixtes
sols contenant du gravier, du sable et plus de 10 % de fines
NOTE Selon le pourcentage d’argile, ces sols peuvent être cohérents ou non.
3.6
fines
particules passant au travers du tamis de 0,063 mm
3.7
D
90
la plus petite ouverture d’un tamis au travers duquel passent 90 % ou plus des particules
4 Appareillage
4.1 Généralités
4.1.1 Balances
Les balances doivent avoir une exactitude de 0,3 % et une résolution de 0,1 % de la masse sèche totale de
l’éprouvette.
4.1.2 Étuves
Les étuves doivent être capables de maintenir une température de 105 °C ± 5 °C et 50 °C ± 5 °C.
4.1.3 Dessiccateur
Le dessiccateur doit contenir du gel de silice anhydre.
2 © ISO 2004 – Tous droits réservés
---------------------- Page: 10 ----------------------
ISO/TS 17892-4:2004(F)
AVERTISSEMENT — Le traditionnel gel de silicate virant au bleu contient du chlorure de cobalt qui a
été classé comme potentiellement cancérigène en cas d’inhalation par la directive européenne
EU Directive 98/98EC.
4.1.4 Cristallisoir
Le cristallisoir doit être en porcelaine ou en métal inoxydable, et d’une contenance minimale de 100 ml.
4.1.5 Tamis
Les tamis, avec les fonds de tamis, doivent comprendre un tamis de 0,063 mm, convenablement renforcé
pour un usage comme tamis de lavage, et un tamis de 2,0 mm.
4.2 Tamisage
4.2.1 Tamis d’essai
Des tamis d’essai en tissu métallique ou en tôle métallique perforée conformes à l’ISO 565 et ISO 3310, avec
des fonds de tamis appropriés doivent être utilisés.
Il convient d’utiliser des tamis d’essai dont les ouvertures couvrent le domaine du sol soumis à essai, mais il
est recommandé d’utiliser au moins 12 tamis dans la gamme complète 125 mm à 0,063 mm. En ce qui
concerne le tamis d’essai le plus fin, il convient d’utiliser un tamis présentant une ouverture de 0,063 mm. Le
nombre de tamis utilisés doit être suffisant pour éviter toute discontinuité détectable dans la courbe
granulométrique. Il convient de contrôler visuellement les tamis d’essai avant chaque utilisation.
4.2.2 Appareillage accessoire
L’appareillage accessoire doit être composé des éléments suivants :
bacs inoxydables ;
grand bac ou seau résistant à la corrosion ou en plastique ;
pelle ;
brosses à tamis ;
tuyau en caoutchouc ;
bécher cylindrique de 800 ml ou plus ;
échantillonneur (éventuellement) ;
tamiseuse mécanique (éventuellement).
© ISO 2004 – Tous droits réservés 3
---------------------- Page: 11 ----------------------
ISO/TS 17892-4:2004(F)
4.3 Méthode du densimètre
4.3.1 Densimètre
Le densimètre doit avoir une forme de torpille et être en verre présentant le moins de défauts visibles possible.
Le verre doit être résistant aux agents chimiques et bien recuit. La tige et le bulbe du densimètre doivent avoir
une section transversale circulaire symétrique par rapport à leur axe et sans variation brutale de section. Dans
toutes les positions de son domaine de mesure, le densimètre doit toujours flotter avec sa tige ne s’écartant
pas de plus 1,5° de la verticale. L’échelle et les inscriptions doivent être marquées clairement et de façon
permanente, sans irrégularités apparentes dans leur espacement. Les lignes de graduation doivent présenter
un intervalle de 0,0005 g/ml et le domaine de mesure doit être compris entre 0,9950 g/ml et 1,0300 g/ml. Le
densimètre doit être identifié par un numéro unique indélébile.
4.3.2 Tubes cylindres en verre gradués
Les tubes cylindres en verre gradués doivent avoir des bords parallèles et une section constante sur toute
leur hauteur. Leur diamètre doit être équivalent à au moins deux fois celui du bulbe du densimètre et leur
hauteur doit assurer une libre flottaison du densimètre dans 1 000 ml d’eau pure.
4.3.3 Thermomètres
Le thermomètre doit couvrir un domaine de température de 0 °C à 50 °C, avec une exactitude de 0,5 °C.
4.3.4 Bain-marie
Le bain-marie doit être isolé et peut être équipé d’un régulateur de température.
4.3.5 Agitateur mécanique ou mélangeur
L’agitateur mécanique ou mélangeur doit être capable de maintenir la quantité appropriée de sol et d’eau
sous forme d’une suspension stable.
4.3.6 Minuteur
Le chronomètre ou la pendule à déclic doit avoir une résolution de 1 s.
4.3.7 Plan de travail
1)
Le plan de travail doit être exempt de vibrations .
4.3.8 Centrifugeuse
La centrifugeuse ou le filtre à vide avec les dispositifs auxiliaires, ou tout autre appareillage similaire, doit être
adapté à la séparation des particules de sol après prétraitement en vue de l’élimination des sels, de la matière
organique et/ou calcaire (éventuellement).
4.4 Méthode de la pipette
4.4.1 Pipette
La pipette doit être étalonnée. Elle doit présenter un volume de 20 ml et être montée selon la configuration de
pipette de la Figure 1.
1) Exempt de vibrations signifie qu’aucune ride n’est visible à la surface de la suspension placée sur le plan de travail.
4 © ISO 2004 – Tous droits réservés
---------------------- Page: 12 ----------------------
ISO/TS 17892-4:2004(F)
Légende
1 Réservoir de rinçage
2 Robinet
3 Tube d’aspiration du réservoir de garde
4 Réservoir de garde
5 Robinet à trois voies pour
6 Tube d’évacuation
7 Pipette de prélèvement
8 Cylindre de sédimentation
9 Echelle graduée
10 Panneau coulissant
11 Colliers d’attache
Figure 1 — Exemple de configuration de pipette
4.4.2 Balance
La balance doit avoir une exactitude de 0,3 mg.
4.4.3 Thermomètres
Les thermomètres doivent couvrir un domaine de température de 0 °C à 50 °C, avec une exactitude de 0,5 °C.
4.4.4 Bain-marie
Le bain-marie doit être isolé et peut être équipé d’un régulateur de température.
4.4.5 Agitateur mécanique ou mélangeur
L’agitateur mécanique ou mélangeur doit être capable de maintenir la quantité appropriée de sol et d’eau
sous forme d’une suspension stable.
4.4.6 Minuteur
Le chronomètre ou une pendule à déclic doit avoir une résolution de 1 s.
© ISO 2004 – Tous droits réservés 5
---------------------- Page: 13 ----------------------
ISO/TS 17892-4:2004(F)
4.4.7 Plan de travail
2)
Le plan de travail doit être exempt de vibrations.
4.4.8 Centrifugeuse
La centrifugeuse ou le filtre à vide avec les dispositifs accessoires, ou tout autre appareillage similaire, doit
être adapté à la séparation des particules de sol après prétraitement en vue de l’élimination des sels, de la
matière organique et/ou calcaire (éventuellement).
4.5 Réactifs
4.5.1 Généralités
Les réactifs doivent être de qualité pour analyse.
4.5.2 Eau
L’eau doit être distillée, déionisée ou déminéralisée.
4.5.3 Agent dispersant
L’agent dispersant peut être de l’eau. Cependant, si une floculation peut se produire, elle doit être évitée en
ajoutant un agent dispersant, qui peut être :
en cas de tamisage : héxamétaphosphate de sodium, approximativement 2 g/l, ou pyrophosphate de
sodium, approximativement 2 g/l ;
en cas de sédimentation : héxamétaphosphate de sodium, approximativement 40 g/l (0,07 M), ou
pyrophosphate de sodium, approximativement 20 g/l (0,07 M).
Les solutions doivent être renouvelées chaque mois. Du carbonate de sodium ne doit pas être ajouté à de
l’héxamétaphosphate de sodium.
4.5.4 Peroxyde d’hydrogène
Le peroxyde d’hydrogène (20 % V/V) peut être utilisé pour éliminer la matière organique.
4.5.5 Acide chlorhydrique
L’acide chlorhydrique (0,2 M (± 1 %)) peut être utilisé pour éliminer les carbonates (éventuellement).
5 Procédures d’essai
5.1 Sélection de la méthode d’essai
La méthode d’essai doit être choisie en respectant les principes suivants :
Pour les sols mixtes, exécuter séparément le tamisage et la sédimentation.
Si 90 % ou plus de particules sont de dimension supérieure à 0,063 mm, procéder à un tamisage.
2) Exempt de vibrations signifie qu’aucune ride n’est visible à la surface de la suspension placée sur le plan de travail.
6 © ISO 2004 – Tous droits réservés
---------------------- Page: 14 ----------------------
ISO/TS 17892-4:2004(F)
Si plus de 10 % des particules sont de dimension inférieure à 0,0063 mm, procéder à une sédimentation.
Si la courbe granulométrique complète est requise, un tamisage et une sédimentation doivent être réalisés.
5.2 Tamisage
5.2.1 Généralités
5.2.1.1 Le mode opératoire général pour le tamisage est schématisé sur la Figure 2.
© ISO 2004 – Tous droits réservés 7
---------------------- Page: 15 ----------------------
ISO/TS 17892-4:2004(F)
Légende
1 Echantillon
2 Echantillonnage ou quartage
3 Séchage
4 Pesage
5 Brassage
6 Séparation par lavage
7 Séchage
8 Tamisage à sec (méthode alternative)
9 Tamisage
10 Pesage
11 Calcul
a Agent dispersant
b Eau claire
Figure 2 — Mode opératoire pour le tamisage
8 © ISO 2004 – Tous droits réservés
---------------------- Page: 16 ----------------------
ISO/TS 17892-4:2004(F)
5.2.1.2 Les tamis doivent être régulièrement contrôlés en conformité avec l’ISO 3310-1 et l’ISO 3310-2.
5.2.1.3 La température de l’étuve doit être contrôlée au plus tous les deux ans au moyen d’un dispositif
de mesure de la température étalonné.
5.2.1.4 La température de l’étuve doit être fixée à 105 °C ± 5 °C, à moins que le sol ne soit sensible à la
chaleur. Un tel sol doit être séché à 50 °C.
NOTE Les sols sensibles à la chaleur comprennent les sols organiques, le gypse et les latérites.
5.2.2 Préparation de l’éprouvette
5.2.2.1 Il convient d’utiliser une préparation par voie humide.
Pour les sols contenant plus de 10 % de fines, l’utilisation d’une préparation par voie sèche peut conduire à
des erreurs importantes.
Les paragraphes 5.2.2.6 à 5.2.2.8 s’appliquent uniquement à la préparation par voie humide.
5.2.2.2 Préparer une éprouvette représentative par division ou quartage, puis séchage à l’étuve. Les
masses minimales de matériau sec requises sont indiquées dans le Tableau 1. S’il s’avère que la quantité de
sol n’est pas suffisante pour garantir ces masses minimales, cela doit être indiqué dans le rapport d’essai.
Tableau 1 — Masses minimales requises pour le tamisage, en fonction du diamètre des particules D
90
Diamètre des
Masse minimale requise pour le
particules
tamisage
D
90
mm g
0,5 50
1,0 100
4,0 150
6,0 350
8,0 600
16,0 2 500
22,4 5 000
31,5 10 000
45,0 20 000
63,0 40 000
75,0 56 000
5.2.2.3 Si la sédimentation est également requise, elle doit être réalisée sur une autre partie, qui n’est
pas séchée à l’étuve.
5.2.2.4 Les sols peuvent être prétraités avant le tamisage pour éliminer, si nécessaire, les sels dissous,
la matière organique et/ou calcaire. La méthode utilisée ainsi que la quantité de matériau éliminé doivent être
indiquées dans le rapport d’essai. Une méthode conseillée pour le prétraitement de sols contenant de la
matière organique et des carbonate
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.