ISO 2961:1974
(Main)Aluminium oxide primarily used for the production of aluminium — Determination of an adsorption index
Aluminium oxide primarily used for the production of aluminium — Determination of an adsorption index
Specifies two methods for industrial calcined products. The first, using carbon tetrachloride vapour, is applicable if the density of the material exceeds 3.75 g/ml; the second, using water vapour, is applicable if the density of the material is lower than 3.75 g/ml. The adsorptive power is evaluated by exposure of a previously dried sample to an atmosphere saturated with carbon tetrachloride or water vapour at a conventional temperature. Measurement of the quantity of the corresponding vapour adsorbed after a conventional time. Has also been approved by the IUPAC.
Oxyde d'aluminium principalement utilisé pour la production de l'aluminium — Détermination d'un indice d'adsorption
General Information
Buy Standard
Standards Content (Sample)
INTERNATIONAL STANDARD
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION l MEXjJYHAPOAHAII OPl-AHW3AI@Ui I-IO CTAHAAPTM3AIVIM.ORGANISATION INTERNATIONALE DE NORMALISATION
Aluminium Oxide primarily used for the production of
aluminium - Determination of an adsorption index
Oxyde d%luminium principalemen t utilise pour Ia production de /“aluminium - Determination d’un indice
fadsorp tion
First edition - 1974-02-15
UDC 661.862.22 : 541.183.5 Ref. No. ISO 2961-1974 (E)
Descriptors : aluminium oxides, adsorption, tests.
Price based on 4 pages
---------------------- Page: 1 ----------------------
FOREWORD
ISO (the International Organization for Standardization) is a worldwide federation
of national Standards institutes (ISO Member Bodies). The work of developing
International Standards is carried out through ISO Technical Committees. Every
Member Body interested in a subject for which a Technical Committee has been set
up has the right to be represented on that Committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the Technical Committees are circulated
to the Member Bodies for approval before their acceptance as International
Standards by the ISO Council.
International Standard ISO 2961 was drawn up by Technical Committee
ISO/TC 47, Chemistry, and circulated to the Member Bodies in October 1972.
lt has been approved by the Member Bodies of the following countries :
Roman ia
Austria India
South Africa, Rep. of
Belgium Israel
Sweden
Czechoslovakia Italy
Thailand
Egypt, Arab Rep. of Netherlands
Turkey
France New Zealand
Germany Poland U.S.S.R.
Hungary Portugal
This International Standard has also been approved by the International Union of
Pure and Applied Chemistry (1 UPAC).
country expressed disapproval of the document
The Member Body of the following
on technical grounds :
Switzer Ia nd
0 International Organkation for Standardization, 1974 l
Printed in Switzerland
---------------------- Page: 2 ----------------------
ISO 29614974 (E)
INTERNATIONAL STANDARD
Aluminium Oxide primarily used for the production of
aluminium - Determination of an adsorption index
4 FIRST METHOD, FOR ALUMINIUM OXIDE OF
0 INTRODUCTION
DENSITY HIGHER THAN 3,75 g/ml
calcined aluminium Oxide possesses,
Any industrial
a greater or lesser power of
depending on its texture,
4.1 Reagent
adsorption of certain reagents, vapours or gases.
The adsorption of a vapour or of a gas on a Sample of 4.1.1 Carbon tetrachloride, p 1,594 g/ml, boiling Point
aluminium Oxide follows the general laws of adsorption on
76,7 “C.
powdered solids.
4.2 Apparatus
Ordinary iaboratory apparatus and :
1 SCOPE AND FIELD OF APPLICATION
This International Standard specifies two methods for the 4.2.1 Weighing bottle, squat form, of borosilicate glass,
determination of an adsorption index for industrial calcined with ground glass cover, diameter 45 mm and height 28 mm
aluminium Oxide. (30 mm with cover) .
The first method, using carbon tetrachloride vapour, is
4.2.2 Electric oven, with natura1 draught, capable of being
applicable if the density is higher than 3,75 g/ml. The
controlled at 300 i IO “C.
second, using water vapour, is applicable if the density is
lower than 3,75 g/ml.
4.2.3 Desiccator, preferably with freshly activated alumina
or phosphorus pentoxide, but not Calcium chloride.
2 REFERENCE
4.2.4 Glass vessel, for use as a desiccator, the dimensions
of which are shown in the figure, fitted with a stainless steel
ISO/ R 802, Aluminium Oxide primarily used for the
support plate, perforated by IO circular apertures evenly
- Preparation and storage o f test
produc tion o f aluminium
distributed as shown in the figure, containing about 200 ml
samples.
of the carbon tetrachloride (4.1 .l), and placed inside an
enclosure at 25 + 0,5 “C.
3 PRINCIPLE
4.3 Procedure
Evaluation of the adsorptive power by exposure of a
previously dried Sample of aluminium Oxide to an
4.3.1 Test Portion
atmosphere saturated with carbon tetrachloride vapour or
conventional
water vapour at a temperature and Dry the weighing bottle (4.2.1), fitted with its cover, for
measurement of the quantity of carbon tetrachloride 2 h in the electric oven (4.2.2) controlled at 300 f: 10 “C.
vapour or water vapour adsorbed after a conventional time. Remove it from the oven, place it in the desiccator (4.2.3)
1
---------------------- Page: 3 ----------------------
ISO 2961-1974 (E)
m3 is the mass, in grams, of the weighing bottle, fitted
and, after cooling, weigh it to the nearest 0,001 g (mass m,).
with its cover, containing the test Portion (4.3.1), after
Then weigh into the weighing bottle, to the nearest 0,l gg
exposure to the atmosphere of carbon tetrachloride;
about 5 g of the crude Sample (see 2.2 of lSO/R 802). Place
the open weighing bottle and its cover in the electric oven
mq is the mass, in grams, of the weighing bottle, fitted
(4.2.2), controlled at 300 + 10 ‘C, and maintain at this
with its cover, after exposure empty and open, to the
temperature for 2 h. Remove it from the oven, place it,
carbon tetrachloride atmosphere;
covered, in the desiccator (4.2.3) and, after cooling, weigh
it to the nearest 0,001 g (mass m2).
1,594 is the density, in grams per millilitre, of the
carbon tetrachloride at 25 “C.
The mass of the test portion, dried at 300 OC, is given by
the differente (m2 - m, ).
4.5 Note
4.3.2 Determination
DO not place more than one weighing bottle in each
adsorption vessel (4.2.4) a
Introduce the weighing bottle containing the test Portion
(4.3.1) into the vessel (4.2.4) containing the carbon
5 SECOND METHOD, FOR ALUMINIUM OXIDE OF
tetrachloride (4.1.1). Place it in the centre of the perforated
DENSITY LOWER THAN 3,75 g/ml
plate forming the support. Open the weighing bottle and
close the vessel (4.2.4).
5.1 Reagents
Maintain at 25 + 0,5 “C for 2 h.
At the end of the 2 h, open
...
NORME INTERNATIONALE
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION .ME)KfiYHAPOAHAfl OPrAHM3AUMR I-l0 CTAHflAPTM3AIJMM -ORGANISATION INTERNATIONALE DE NORMALISATION
Oxyde d’aluminium principalement utilisé pour la production
de l’aluminium - Détermination d’un indice d’adsorption
Aluminium oxide primarily used for the production of aluminium - Determination of an adsorption index
Première édition - 1974-02-I 5
CDU 661.862.22 : 541.183.5 Réf. No : ISO 2961-1974 (F)
Descripteurs : oxyde d’aluminium, adsorption, essai.
Prix basé sur 4 pages
---------------------- Page: 1 ----------------------
AVANT-PROPOS
ISO (Organisation Internationale de Normalisation) est une fédération mondiale
d’organismes nationaux de normalisation (Comités Membres ISO). L’élaboration de
Normes internationales est confiée aux Comités Techniques ISO. Chaque Comité
Membre intéressé par une étude a le droit de faire partie du Comité Technique
correspondant. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec I’ISO, participent également aux travaux.
Les Projets de Normes Internationales adoptés par les Comités Techniques sont
soumis aux Comités Membres pour approbation, avant leur acceptation comme
Normes Internationales par le Conseil de I’ISO.
La Norme Internationale ISO 2961 a été établie par le Comité Technique
lSO/TC 47, Chimie, et soumise aux Comités Membres en octobre 1972.
Elle a été approuvée par les Comités Membres des pays suivants :
Afrique du Sud, Rép. d’
Inde Roumanie
Allemagne
Israël Suède
Autriche
Italie Tchécoslovaquie
Belgique
Nouvelle-Zélande Thaïlande
Egypte, Rép. arabe d’ Pays-Bas Turquie
France
Pologne U.R.S.S.
Hongrie Portugal
Cette Norme Internationale a également été approuvée par l’Union Internationale de
Chimie Pure et Appliquée (UICPA).
Le Comité Membre du pays suivant a désapprouvé le document pour des raisons
techniques :
Suisse
0 Organisation Internationale de Normalisation, 1974 l
Imprimé en Suisse
---------------------- Page: 2 ----------------------
ISO 2961-1974 (F)
NORME INTERNATIONALE
Oxyde d’aluminium principalement utilisé pour la production
de l’aluminium - Détermination d’un indice d’adsorption
4 PREMIÈRE MÉTHODE - OXYDE D’ALUMINIUM DE
r) INTRODUCTION
MASSE VOLUMIQUE SUPÉRIEURE À 3,75 g/ml
Tout oxyde d’aluminium calciné industriel possède, selon sa
texture, un pouvoir plus ou moins important d’adsorption
4.1 Réactif
de certains réactifs, vapeurs ou gaz.
L’adsorption d’une vapeur ou d’un gaz sur un échantillon 4.1.1 Tétrachlorure de carbone, p 1,594 g/ml, point
d’oxyde d’aluminium suit les lois générales de I’adsorption
d’ébulition 76,7 “C.
...
NORME INTERNATIONALE
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION .ME)KfiYHAPOAHAfl OPrAHM3AUMR I-l0 CTAHflAPTM3AIJMM -ORGANISATION INTERNATIONALE DE NORMALISATION
Oxyde d’aluminium principalement utilisé pour la production
de l’aluminium - Détermination d’un indice d’adsorption
Aluminium oxide primarily used for the production of aluminium - Determination of an adsorption index
Première édition - 1974-02-I 5
CDU 661.862.22 : 541.183.5 Réf. No : ISO 2961-1974 (F)
Descripteurs : oxyde d’aluminium, adsorption, essai.
Prix basé sur 4 pages
---------------------- Page: 1 ----------------------
AVANT-PROPOS
ISO (Organisation Internationale de Normalisation) est une fédération mondiale
d’organismes nationaux de normalisation (Comités Membres ISO). L’élaboration de
Normes internationales est confiée aux Comités Techniques ISO. Chaque Comité
Membre intéressé par une étude a le droit de faire partie du Comité Technique
correspondant.
Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec I’ISO, participent également aux travaux.
Les Projets de Normes Internationales adoptés par les Comités Techniques sont
soumis aux Comités Membres pour approbation, avant leur acceptation comme
Normes Internationales par le Conseil de I’ISO.
La Norme Internationale ISO 2961 a été établie par le Comité Technique
lSO/TC 47, Chimie, et soumise aux Comités Membres en octobre 1972.
Elle a été approuvée par les Comités Membres des pays suivants :
Afrique du Sud, Rép. d’
Inde Roumanie
Allemagne Israël Suède
Autriche Italie Tchécoslovaquie
Belgique Nouvelle-Zélande Thaïlande
Egypte, Rép. arabe d’ Pays-Bas Turquie
France Pologne U.R.S.S.
Hongrie Portugal
Cette Norme Internationale a également été approuvée par l’Union Internationale de
Chimie Pure et Appliquée (UICPA).
Le Comité Membre du pays suivant a désapprouvé le document pour des raisons
techniques :
Suisse
0 Organisation Internationale de Normalisation, 1974 l
Imprimé en Suisse
---------------------- Page: 2 ----------------------
ISO 2961-1974 (F)
NORME INTERNATIONALE
Oxyde d’aluminium principalement utilisé pour la production
de l’aluminium - Détermination d’un indice d’adsorption
r) INTRODUCTION 4 PREMIÈRE MÉTHODE - OXYDE D’ALUMINIUM DE
MASSE VOLUMIQUE SUPÉRIEURE À 3,75 g/ml
Tout oxyde d’aluminium calciné industriel possède, selon sa
texture, un pouvoir plus ou moins important d’adsorption
4.1 Réactif
de certains réactifs, vapeurs ou gaz.
L’adsorption d’une vapeur ou d’un gaz sur un échantillon 4.1.1 Tétrachlorure de carbone, p 1,594 g/ml, point
d’oxyde d’aluminium suit les lois générales de I’adsorption
d’ébulition 76,7 “C.
des corps pulvérulents.
4.2 Appareilla
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.