ISO 25319:2026
(Main)Determination of metallic Fe in reduced iron (sponge Iron) and briquette — Iron (III) chloride titrimetric method
- Abstract
This method is applicable to a concentration range of 52,80 % mass fraction to 86,40 % mass fraction of the metallic Fe.
- Status
- Published
- Publication Date
- 04-Nov-2026
- Technical Committee
- ISO/TC 102/SC 2 - Chemical analysis
- Drafting Committee
- ISO/TC 102/SC 2/WG 55 - Fe Metal in sponge iron and briquettes
- Current Stage
- 6060 - International Standard published - 60 Publication
- Start Date
- 05-Nov-2026
- Due Date
- 05-Nov-2026
- Completion Date
- 05-Nov-2026
ISO 25319:2026 is an International Standard from ISO for determining metallic Fe in reduced iron (sponge Iron) and briquette by an iron(III) chloride titrimetric method. It specifies a laboratory procedure for samples in the metallic Fe range of 52.80 % to 86.40 % mass fraction, with duplicate testing, blank correction and result-acceptance rules.
What does ISO 25319:2026 specify?
ISO 25319:2026 specifies how to measure metallic Fe in reduced iron (sponge Iron) and briquette by dissolving the metallic iron with iron(III) chloride and titrating the liberated iron(II) with potassium dichromate. In practice, the method tells a laboratory how to prepare the sample, carry out the titration, calculate the result and report it.
The document is organized into clauses for scope, references, terms, principle, reagents, apparatus, sampling and sample preparation, procedure, expression of results and test report. It also includes three annexes that support result checking, standardization of the titrant and statistical background data.
| Annex | What it covers |
|---|---|
| Annex A | Flowsheet for accepting test results |
| Annex B | Calculation of the correction factor F for potassium dichromate |
| Annex C | Interlaboratory results, calculations and statistical assessment |
What are the key requirements of ISO 25319:2026?
ISO 25319:2026 is a wet-chemical method with defined preparation, titration and result-acceptance steps. The key point for users is that the procedure is not just a titration - it also sets the sample condition, the blank correction and the way independent replicates are checked.
Sample scope and preparation
Clause 1 limits the method to samples with metallic Fe between 52.80 % and 86.40 % mass fraction. Clause 7 requires the sample to be dried at or below 105 °C to constant mass and then cooled in a desiccator, and the laboratory sample must have a particle size below 160 µm and be prepared according to ISO 10835. That matters because moisture and coarse particles can shift the measured metallic Fe content.
Reagents and apparatus
Clauses 5 and 6 require analytical-grade reagents, distilled or equivalent water, a 0.016 67 mol/L potassium dichromate titrant, iron(III) chloride solution, mixed acid, and either sodium or barium diphenylamine sulfonate indicator. The apparatus includes an analytical balance readable to 0.1 mg and a burette conforming to ISO 385. In practice, the method depends on accurate weighing and a burette that delivers consistent titration volumes.
Decomposition and titration
Clause 8 requires duplicate determinations. The test portion is about 0.100 0 g, then treated with iron(III) chloride solution and ammonium chloride solution while stirred for at least 30 minutes, after which sulfuric-phosphoric acid, indicator and water are added and the solution is titrated with potassium dichromate. The end point is a permanent purple colour. A blank test is run in parallel, and a new batch of iron(III) chloride solution requires a blank. This is the control that removes reagent background from the final result.
Result calculation and acceptance
Clause 9 gives the calculation of metallic iron content from the sample titration volume, blank volume, correction factor F, titrant concentration and sample mass. It also points users to the precision statement and to Annex A for checking whether independent replicate results are acceptable. Annex B gives the procedure for determining F, so the titrant is standardized before use.
Reporting
Clause 10 lists the information to include in the test report: laboratory identification, dates, sample identification, the reference to ISO 25319:2026, the result to one decimal place, observations that may have affected the result, any optional or unspecified operations, and verification activities. That helps buyers and producers compare results from different laboratories on the same basis.
What terms does ISO 25319:2026 define?
- Metallic Fe - the form of iron measured by this method; the result is reported as a mass fraction of the sample.
- Blank test - a parallel run without sample that measures reagent contribution and is subtracted from the sample titration.
- Potassium dichromate solution - the titrant used to oxidize iron(II) during the final titration step.
- Independent replicate limit (Rd) - the acceptance limit used in Annex A to judge whether duplicate results can be accepted.
- Repeatability - the closeness of results under the same laboratory conditions, used here in the precision statement.
- Reproducibility - the closeness of results under different laboratories or conditions, also given in the precision statement.
Who uses ISO 25319:2026?
ISO 25319:2026 is used by chemical testing laboratories, producers of reduced iron and briquette, and quality teams that need a defined method for metallic Fe determination. It is relevant when a plant, supplier or buyer needs a laboratory result for product control, acceptance testing or comparison of batches.
Which standards are used with ISO 25319:2026?
ISO 25319:2026 refers to three standards in its normative references:
- ISO 385 - specifies the burette requirements used for the titration step.
- ISO 10835 - gives the sampling and sample preparation rules for direct reduced iron and hot briquetted iron.
- ISO 11323 - provides the vocabulary used for the terms and definitions in this document.
ISO 5725-2 is listed in the bibliography as a background reference for repeatability and reproducibility concepts.
What does the ISO 25319:2026 document contain?
Clause 4 gives the reaction principle for converting metallic iron and then titrating iron(II) with dichromate. Clause 5 gives the reagent preparations, including the indicator options and the correction-factor standardization route.
Clause 8 contains the step-by-step test procedure, including duplicate testing, blank testing and the end-point colour change. Clause 9 contains the calculation formula for metallic Fe and the precision treatment, including the use of Annex A for result acceptance.
Annex A provides a flowchart for accepting test results, Annex B provides a formula for the potassium dichromate correction factor F, and Annex C gives interlaboratory data, calculations and statistical plots. Those annexes are used for method control, standardization and confidence in the reported result.
Get Certified
Connect with accredited certification bodies for this standard

Bureau Veritas Chile
Bureau Veritas certification services in Chile.

Bureau Veritas Peru
Bureau Veritas certification services in Peru.

BVQI Peru
Bureau Veritas certification in Peru.
Sponsored listings
Frequently Asked Questions
ISO 25319:2026 is a standard published by the International Organization for Standardization (ISO). Its full title is "Determination of metallic Fe in reduced iron (sponge Iron) and briquette — Iron (III) chloride titrimetric method". This standard covers: This method is applicable to a concentration range of 52,80 % mass fraction to 86,40 % mass fraction of the metallic Fe.
This method is applicable to a concentration range of 52,80 % mass fraction to 86,40 % mass fraction of the metallic Fe.
ISO 25319:2026 is classified under the following ICS (International Classification for Standards) categories: 73.060.10 - Iron ores. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO 25319:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Principle
- 5 Reagents
- 5.1 Iron (III) chloride solution 7 %
- 5.2 Standard potassium dichromate solution, 0,016 67 mol/L
- 5.3 Mixed acid
- 5.4 Sodium diphenylamine sulfonate 2 g/l
- 5.5 Barium diphenylamine sulfonate 2 g/l
- 5.7 Ammonium iron(ΙΙ) sulfate hexahydrate
- 6 Apparatus
- 6.7 Beaker
- 7 Sampling and sample preparation
- 7.1 Sample preparation
- 7.2 Laboratory sample
- 8 Procedure
- 8.1 Number of determinations
- 8.2 Preparation of test portions
- 8.3 Determination
- 9 Expression of results
- 9.1 Calculation of the metallic iron content
- 9.2 General treatment of result
- 10 Test report
- Annex A
- Annex B
- Annex C
- Bibliography
1 Scope
This method is applicable to a concentration range of 52,80 % mass fraction to 86,40 % mass fraction of the metallic Fe.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 385, Laboratory glassware — Burettes ISO 10835, Direct reduced iron and hot briquetted iron — Sampling and sample preparation ISO 11323, Iron ore and direct reduced iron — Vocabulary
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 11323 apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
4 Principle
0 +2 Iron present in the oxidation state Fe in the sample is oxidized to Fe by the action of FeCl . This reaction is
catalysed by ammonium chloride according to the following reaction:
2FeCl + Fe 3FeCl 3 2 2+ Fe is oxidized and titrated with potassium dichromate solution using the sodium diphenylamine sulfonate indicator (or barium diphenylamine sulfonate) according to the following reaction:
2+ 2- + 3+ 3+ 6Fe + Cr O + 14H 6Fe + 2Cr + 7H O 2 7 2
5 Reagents
During the analysis, use only reagents of recognized analytical reagent grade and only distilled water or water of equivalent purity.
ISO 25319:2026(en)
5.1 Iron (III) chloride solution 7 %
Add 117 g of iron (III) chloride hexahydrate to a 2 000 ml container holding 600 ml of water and agitate until it is completely dissolved. Dilute with water to a volume of 1 000 ml. NOTE For better dissolution of the iron (III) chloride, use hot water (60 °C to 80 °C). The ideal condition is a complete dissolution of the salt resulting in a translucent solution.
5.2 Standard potassium dichromate solution, 0,016 67 mol/L
Add 4,903 1 g of dried potassium dichromate to a 2 000 ml container holding 600 ml of water and agitate until it is completely dissolved. Dilute with water to a volume of 1 000 ml. Prepare a standard potassium dichromate solution following the directions in Annex B
5.3 Mixed acid
Add 700 ml of water to a 2 000 ml beaker. Place the beaker in a cool place and add slowly with stirring 150 ml of phosphoric acid, 1,7 b/ml. Allow cooling. Add slowly with stirring 150 ml of sulfuric acid, 1,84 g/ ml and allow cooling (it is optional: placing the beaker in an ice-water bath). Dilute this mixture to 1 000 ml with stirring.
5.4 Sodium diphenylamine sulfonate 2 g/l
Dissolve 0,2 g of powdered sodium diphenylamine sulfonate (C H NHC H SO Na) in a small volume of water 6 5 6 4 3 and dilute to 100 ml. Store this solution in a brown glass bottle.
5.5 Barium diphenylamine sulfonate 2 g/l
Dissolve 0,2 g of powdered barium diphenylamine sulfonate ((C H NHC H SO ) Ba) in 15 ml of hydrochloric 6 5 6 4 3 2 acid 1 mol/L and put the container on the heater and heat (heat under 100 °C to prevent HCl volatilization or reagent decomposition due to excessive temperature) until the salt is completely solved. (Approximate time of dissolution is 15-30 minutes). Dilute this mixture to 100 ml and store this solution in a brown glass bottle. NOTE As both sodium and barium diphenylamine sulfonate are equal as an indicator, there is no difference in the use of either of them.
5.6 Ammonium chloride solution 100 g/l.
Dissolve 100 g ammonium chloride (NH Cl) to a small volume of water and dilute to 1 000 ml.
5.7 Ammonium iron(ΙΙ) sulfate hexahydrate
Ammonium iron(ΙΙ) sulfate hexahydrate1,86g/cm (20 °C), Molar mass 392,14 g/mol.
6 Apparatus
6.1 Analytical balance, capable of weighing to the nearest 0,1 mg. 6.2 Erlenmeyer flask, wide mouth (500 ml).
6.3 Magnet stirrer, with magnetic stirring bar.
6.4 Measuring cylinder, of appropriate volume.
6.5 A grade burette, mark A, shall conform to the specifications of ISO 385.
ISO 25319:2026(en) 6.6 Non-magnetic spatula.
6.7 Beaker
7 Sampling and sample preparation
7.1 Sample preparation
After receiving the sample, the sample shall be dried at or below a temperature of 105 °C until a constant weight is reached. Then let the sample cool to room temperature in a desiccator.
7.2 Laboratory sample
For analysis, use a laboratory sample of particle size of less than 160 µm which has been taken and prepared in accordance with ISO 10835.
8 Procedure
8.1 Number of determinations
All determinations should be carried out in duplicate. If necessary, make further determinations in accordance with the flowsheet presented in Annex A.
...