Abstract

the qualitative detection of Atlantic salmon-specific DNA derived from foodstuffs and feedstuffs. It requires extraction of an adequate amount of PCR amplifiable DNA from the relevant foodstuffs and feedstuffs matrix and specific primer/probes unique for detection of Atlantic salmon material derived from Atlantic salmon (Salmo salar).

Status
Not Published
Current Stage
5020 - FDIS ballot initiated: 2 months. Proof sent to secretariat
Start Date
02-Nov-2026
Completion Date
02-Nov-2026

Buy Documents

Draft

ISO/DTS 20224-12 - Molecular biomarker analysis — Detection of animal-derived materials in foodstuffs and feedstuffs by real-time PCR — Part 12: Atlantic salmon DNA detection method

Release Date:19-Oct-2026
English language (21 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/DTS 20224-12 - Molecular biomarker analysis — Detection of animal-derived materials in foodstuffs and feedstuffs by real-time PCR — Part 12: Atlantic salmon DNA detection method

Release Date:19-Oct-2026
English language (21 pages)
sale 15% off
sale 15% off

ISO/DTS 20224-12 is an ISO document for the qualitative detection of Atlantic salmon DNA in foodstuffs and feedstuffs by real-time PCR. It specifies the target sequence, the primer-probe assay, the test workflow, result interpretation, and validation evidence for detecting Salmo salar material in laboratory testing.

What does ISO/DTS 20224-12 specify?

ISO/DTS 20224-12 specifies a real-time PCR method for the qualitative detection of Atlantic salmon-specific DNA derived from foodstuffs and feedstuffs. The method is built for laboratories that need to check whether Salmo salar material is present in a sample, not to measure how much is present.

The document is organized into scope, normative references, terms and definitions, scientific basis, reagents and materials, apparatus, procedure, accept/reject criteria, validation status and performance criteria, and test report. It also includes two informative annexes that support specificity assessment.

AnnexWhat it covers
Annex ABLASTN results for the 143 bp query sequence from GenBank accession LC012541.1, used to examine sequence similarity and specificity
Annex BMembers of the Salmonidae family and a family tree based on NCBI Taxonomy, used to show related species considered in specificity work

What are the key requirements of ISO/DTS 20224-12?

ISO/DTS 20224-12 is centered on a specific mitochondrial target, controlled PCR setup, and clear decision rules for a positive result. In practice, that means the user must prepare a suitable DNA extract, run the defined assay with the right controls, and interpret amplification against the document’s acceptance criteria.

Target sequence and sample preparation

Clause 1 defines the target as a partial fragment of the Atlantic salmon NADH dehydrogenase subunit 5 (ND5) gene, identified by GenBank accession number LC012541.1. The scope also requires extraction of an adequate amount of PCR-amplifiable DNA from the relevant matrix.

Clause 7.1 says the test portion should be representative of the laboratory sample and homogeneous, for example by grinding or homogenizing. Clause 7.2 points users to ISO 21571 for extraction and purification. In practice, this means poor sampling or poor extraction can give a false negative even if Atlantic salmon is present.

Reagents, oligonucleotides, and instrument capability

Clause 5 requires analytical-grade reagents suitable for molecular biology, powder-free gloves, and aerosol-protected pipette tips. Table 1 gives the primer and probe set for the target assay, including the forward primer A.salmon-143-F, reverse primer A.salmon-143-R, and probe A.salmon-143-P.

Clause 6 requires a real-time thermocycler that can excite and detect the fluorophore used in the assay, which is set up in TaqMan format. In practice, the instrument must support fluorescence-based detection, or the assay cannot be read correctly.

PCR setup and controls

Clause 7.3 defines a 25 µl reaction volume with 5 µl of sample DNA or control added to the reaction mix. The document also notes that the amount of DNA in one reaction can be up to 200 ng, but recommends staying below that amount.

The controls matter because they show whether a result can be trusted. Clause 7.3.2 requires PCR controls as described in ISO 24276 and ISO 20813:2019, and it adds a reference-gene inhibition control using either the 18S rRNA gene for eukaryotes or the COI gene for fish. In practice, the controls help separate a true negative from an inhibited or failed PCR.

Temperature-time programme

Clause 7.4 gives the temperature-time programme used in validation, including UNG activation when uracil-N-glycosylase is present in the mastermix, initial denaturation, and 45 amplification cycles. The document also says different conditions and cycles shall be verified if they are changed.

This matters because PCR performance depends on cycling conditions. A lab that uses a different mastermix or instrument needs to confirm that the assay still works as intended.

Accept/reject criteria and retesting

Clause 8 says a positive result is indicated by a sigmoid-shaped amplification curve, a usable quantification cycle value, no amplification in negative controls, and expected amplification in the positive DNA target control and inhibition control. The target is considered detected when the three Atlantic salmon-specific oligonucleotides produce the expected signal and the controls behave correctly.

The document also defines trace detections and gives a retest rule for contradictory results or trace findings. In that case, the sample is retested from at least two new extracts, with at least 20 PCR replicates across the new extracts, and the target is called detected only if at least 95% of those results are positive. This is important in practice because it prevents a single borderline signal from being over-interpreted.

Validation and performance

Clause 9 states that validation followed in-house validation and collaborative trial validation. The document reports robustness checks across different instruments, reaction volumes, annealing temperatures, and reduced primer/probe concentrations.

It also reports reproducibility testing across 11 participants and species-specificity testing against a range of fish, animal, human, and plant DNA samples. The sensitivity section states an absolute limit of detection of 5 DNA copies at 95% confidence. For users, this tells them what level of sensitivity the method achieved and how broadly the assay was challenged before publication.

What terms does ISO/DTS 20224-12 define?

  • Atlantic salmon (Salmo salar) - the species targeted by the assay and the source of the DNA sequence used for detection.
  • NADH dehydrogenase subunit 5 (ND5) - the mitochondrial gene fragment selected as the PCR target.
  • real-time PCR - a PCR method that monitors amplification through fluorescence while the reaction runs.
  • quantification cycle (Cq) - the cycle number at which the amplification curve crosses the fluorescence threshold.
  • limit of detection (LOD95%) - the lowest target level detected with 95% confidence; this document reports 5 copies per reaction.
  • probability of detection (POD) - the statistical measure used in validation to describe how likely the assay is to detect the target at a given copy number.
  • BLASTN - the nucleotide similarity search tool used in Annex A to assess how specific the target sequence is.
  • uracil-N-glycosylase (UNG) / uracil-DNA glycosylase (UDG) - enzymes used to reduce carry-over contamination when included in the mastermix.

Who uses ISO/DTS 20224-12?

ISO/DTS 20224-12 is used by laboratories testing foodstuffs and feedstuffs for Atlantic salmon DNA. It is relevant to molecular biology labs, food and feed testing laboratories, and quality assurance teams that need to screen ingredients or products for Salmo salar material.

It is also useful to buyers, producers, and inspectors who need a defined PCR method for checking species identity in the food and feed chain. In practice, it supports work on authenticity testing, contamination checks, and investigation of possible adulteration.

Which standards are used with ISO/DTS 20224-12?

  • ISO 16577:2022 - provides the vocabulary for molecular biomarker analytical methods in agriculture and food production.
  • ISO 20813 and ISO 20813:2019 - provide general requirements and definitions for detection and identification of animal species in foods and food products using nucleic acid-based methods.
  • ISO 21571:2005 - provides methods for nucleic acid extraction, which the document relies on for obtaining amplifiable DNA.
  • ISO 24276:2006 - provides general requirements and definitions for GMO-related food analysis workflows, including control and reporting concepts used here.
  • ISO 20224 (all parts) - the parent series for animal-derived material detection by real-time PCR, within which this Atlantic salmon method sits.

What does the ISO/DTS 20224-12 document contain?

ISO/DTS 20224-12 contains the assay design, reagent requirements, apparatus needs, reaction setup, cycling programme, decision rules, and validation summary for Atlantic salmon DNA detection. Table 1 gives the primer and probe set, Table 2 gives the 25 µl reaction setup, and Table 3 gives the temperature-time programme.

The validation section includes robustness, reproducibility, sensitivity, and specificity data. Tables 4 to 7 summarize collaborative-trial outcomes, probability-of-detection data, and species-specificity results. Annex A provides BLASTN result tables and alignments for the target sequence, while Annex B lists Salmonidae members and shows the family tree used to interpret specificity.

Buy Documents

Draft

ISO/DTS 20224-12 - Molecular biomarker analysis — Detection of animal-derived materials in foodstuffs and feedstuffs by real-time PCR — Part 12: Atlantic salmon DNA detection method

Release Date:19-Oct-2026
English language (21 pages)
sale 15% off
sale 15% off
Draft

REDLINE ISO/DTS 20224-12 - Molecular biomarker analysis — Detection of animal-derived materials in foodstuffs and feedstuffs by real-time PCR — Part 12: Atlantic salmon DNA detection method

Release Date:19-Oct-2026
English language (21 pages)
sale 15% off
sale 15% off

Get Certified

Connect with accredited certification bodies for this standard

BSI Group

BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

UKAS United Kingdom Verified

Bureau Veritas

Bureau Veritas is a world leader in laboratory testing, inspection and certification services.

COFRAC France Verified

DNV

DNV is an independent assurance and risk management provider.

NA Norway Verified

Sponsored listings

Frequently Asked Questions

ISO/DTS 20224-12 is a draft published by the International Organization for Standardization (ISO). Its full title is "Molecular biomarker analysis — Detection of animal-derived materials in foodstuffs and feedstuffs by real-time PCR — Part 12: Atlantic salmon DNA detection method". This standard covers: the qualitative detection of Atlantic salmon-specific DNA derived from foodstuffs and feedstuffs. It requires extraction of an adequate amount of PCR amplifiable DNA from the relevant foodstuffs and feedstuffs matrix and specific primer/probes unique for detection of Atlantic salmon material derived from Atlantic salmon (Salmo salar).

the qualitative detection of Atlantic salmon-specific DNA derived from foodstuffs and feedstuffs. It requires extraction of an adequate amount of PCR amplifiable DNA from the relevant foodstuffs and feedstuffs matrix and specific primer/probes unique for detection of Atlantic salmon material derived from Atlantic salmon (Salmo salar).

ISO/DTS 20224-12 is classified under the following ICS (International Classification for Standards) categories: 67.050 - General methods of tests and analysis for food products. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO/DTS 20224-12 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


FINAL DRAFT
Technical
Specification
ISO/TC 34/SC 16
Molecular biomarker analysis —
Secretariat: ANSI
Detection of animal-derived
Voting begins on:
materials in foodstuffs and
2026-11-02
feedstuffs by real-time PCR —
Voting terminates on:
2026-12-28
Part 12:
Atlantic salmon DNA detection
method
RECIPIENTS OF THIS DRAFT ARE INVITED TO SUBMIT,
WITH THEIR COMMENTS, NOTIFICATION OF ANY
RELEVANT PATENT RIGHTS OF WHICH THEY ARE AWARE
AND TO PROVIDE SUPPOR TING DOCUMENTATION.
IN ADDITION TO THEIR EVALUATION AS
BEING ACCEPTABLE FOR INDUSTRIAL, TECHNO-
LOGICAL, COMMERCIAL AND USER PURPOSES, DRAFT
INTERNATIONAL STANDARDS MAY ON OCCASION HAVE
TO BE CONSIDERED IN THE LIGHT OF THEIR POTENTIAL
TO BECOME STAN DARDS TO WHICH REFERENCE MAY BE
MADE IN NATIONAL REGULATIONS.
Reference number
FINAL DRAFT
Technical
Specification
ISO/TC 34/SC 16
Molecular biomarker analysis —
Secretariat: ANSI
Detection of animal-derived
Voting begins on:
materials in foodstuffs and
feedstuffs by real-time PCR —
Voting terminates on:
Part 12:
Atlantic salmon DNA detection
method
© ISO 2026
All rights reserved.
RECIPIENTS OF THIS DRAFT ARE INVITED TO SUBMIT,
WITH THEIR COMMENTS, NOTIFICATION OF ANY
This ISO publication is protected by copyright and is owned by ISO and/or its licensors.
RELEVANT PATENT RIGHTS OF WHICH THEY ARE AWARE
The content of this ISO publication is provided under licence, not sold. Use is subject to the applicable licence terms issued by ISO,
AND TO PROVIDE SUPPOR TING DOCUMENTATION.
an ISO member body, or an authorized third-party distributor.
IN ADDITION TO THEIR EVALUATION AS
BEING ACCEPTABLE FOR INDUSTRIAL, TECHNO-
Except as required for implementation or expressly permitted by a separate licence, no part of this ISO publication may be
LOGICAL, COMMERCIAL AND USER PURPOSES, DRAFT
reproduced, distributed, modified, used, or made available in any form or by any means – electronic or mechanical, including
INTERNATIONAL STANDARDS MAY ON OCCASION HAVE
photocopying, scanning, recording, or posting on internal or external digital platforms. TO BE CONSIDERED IN THE LIGHT OF THEIR POTENTIAL
TO BECOME STAN DARDS TO WHICH REFERENCE MAY BE
Any use beyond the scope of the granted rights is prohibited and may result in legal action.
MADE IN NATIONAL REGULATIONS.
ISO copyright office
CP 401 • CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
Reference number
ii
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Scientific basis . 2
5 Reagents and materials . 2
6 Apparatus . 2
7 Procedure . 3
7.1 Preparation of the test portion/sample .3
7.2 Preparation of DNA extracts .3
7.3 PCR setup.3
7.3.1 Reaction mixes .3
7.3.2 PCR controls .4
7.3.3 Real-time PCR thermocycler plate set-up.4
7.4 Temperature-time programme.4
8 Accept/reject criteria . 5
8.1 General .5
8.2 Identification .5
9 Validation status and performance criteria . 5
9.1 General .5
9.2 Robustness .5
9.3 Reproducibility .6
9.4 Sensitivity .6
9.5 Specificity .8
10 Test report . 10
Annex A (informative) Nucleotide basis local alignment tool (BLASTN®) +2.16.1+ results for
query of GenBank® . .11
Annex B (informative) Members of the Salmonidae family and its family tree established with
NCBI Taxonomy .15
Bibliography .21

iii
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out through
ISO technical committees. Each member body interested in a subject for which a technical committee
has been established has the right to be represented on that committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely
with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are described
in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types
of ISO document should be noted. This document was drafted in accordance with the editorial rules of the
ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed patent
rights in respect thereof. As of the date of publication of this document, ISO had not received notice of (a)
patent(s) which may be required to implement this document. However, implementers are cautioned that
this may not represent the latest information, which may be obtained from the patent database available at
www.iso.org/patents. ISO shall not be held responsible for identifying any or all such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement. For an explanation of the voluntary nature of standards, the meaning of ISO
specific terms and expressions related to conformity assessment, as well as information about ISO's
adherence to the World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see
www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 34, Food products, Subcommittee SC 16,
Horizontal methods for molecular biomarker analysis.
A list of all parts in the ISO 20224 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.

iv
Introduction
Fraudulent adulteration of meat in food and feed threatens both public safety and commerce. Adulteration
can affect those adhering to ethnological dietary rules, economic development and social stability. This
document provides a real-time polymerase chain reaction (PCR) analytical method for the identification of
meat animal species from nucleic acid present in the ingredients of food and feed.
Animal-derived biological materials in food and feed are detected and identified in the laboratory with the
following successive (or simultaneous) steps:
— preparation of the test portion/sample;
— nucleic acid extraction and purification;
— PCR amplification and interpretation of results.
This document provides guidance for PCR amplification and interpretation of results, specific to Atlantic
salmon (Salmo salar) DNA detection.
[1]
The ISO 20224 series consists of documents that describe specific applications.

v
FINAL DRAFT Technical Specification ISO/DTS 20224-12:2026(en)
Molecular biomarker analysis — Detection of animal-derived
materials in foodstuffs and feedstuffs by real-time PCR —
Part 12:
Atlantic salmon DNA detection method
1 Scope
This document specifies a real-time polymerase chain reaction (PCR) method for the qualitative detection of
Atlantic salmon (Salmo salar)-specific DNA derived from food and feed.
It requires the extraction of an adequate amount of PCR amplifiable DNA from the relevant matrix and can
be applied to detection of Atlantic salmon material.
The target sequence is a partial fragment of the Atlantic salmon NADH dehydrogenase subunit 5 (ND5) gene
1) [2]
(i.e. GenBank® accession number LC012541.1) from the mitochondrial genome of Atlantic salmon. The
provided PCR assay for this target has an absolute limit of detection of five copies per reaction, with ≥ 95 %
confidence at this concentration (LOD ).
95 %
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
ISO 16577:2022, Molecular biomarker analysis — Vocabulary for molecular biomarker analytical methods in
agriculture and food production
ISO 20813, Molecular biomarker analysis — Methods of analysis for the detection and identification of animal
species in foods and food products (nucleic acid-based methods) — General requirements and definitions
ISO 20813:2019, Molecular biomarker analysis — Methods of analysis for the detection and identification of
animal species in foods and food products (nucleic acid-based methods) — General requirements and definitions
ISO 21571, Foodstuffs — Methods of analysis for the detection of genetically modified organisms and derived
products — Nucleic acid extraction
ISO 24276:2006, Foodstuffs — Methods of analysis for the detection of genetically modified organisms and
derived products — General requirements and definitions
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 16577:2022 apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at https:// www .electropedia .org/
1) GenBank® is an example of a suitable product available commercially. This information is given for the convenience
of users of this document and does not constitute an endorsement by ISO of this product. Equivalent products may be
used if they can be shown to lead to the same results.

4 Scientific basis
[3]
DNA is extracted from the test portion by applying a suitable method (see ISO 21571:2005 , Clause A.1).
The DNA analysis consists of two parts:
— verification of the quality and amplifiability of the extracted DNA using a PCR assay specific for eukaryotes
(i.e. 18S rRNA gene) or fish (i.e. COI gene);
— detection of the Atlantic salmon species-specific DNA sequence of the ND5 gene (i.e. GenBank® accession
number LC012541.1) in a real-time PCR.
NOTE The use of a mitochondrial marker gene as a PCR target offers greater sensitivity due to the presence of
multiple mitochondria per cell but also makes quantification challenging or even impossible due to the variability in
mitochondrial numbers per cell.
5 Reagents and materials
Only reagents and water of recognized analytical grade, appropriate for molecular biology, shall be used.
Unless stated otherwise, solutions shall be prepared by dissolving the corresponding reagents in water
followed by autoclave sterilization. For all operations in which gloves are used, gloves shall be powder free.
Aerosol-protected pipette tips (protection against cross-contamination) shall be used.
5.1 PCR master mix.
In general, the real-time PCR master mix contains thermostable DNA polymerase, dNTPs, MgCl , KCl and
buffer as a dilutable concentrated mixture that is ready to use.
NOTE A commercial real-time PCR master mix can be used.
5.2 Oligonucleotides.
The quality of the oligonucleotides shall be sufficient for their use as primers and probes. See Table 1.
Table 1 — Oligonucleotides
Name DNA sequence of the oligonucleotide Final concentration in PCR
a
Atlantic salmon ND5 gene as the target sequence (GenBank® accession number LC012541.1)
A.salmon-143-F 5ʹ-AACTTGCATCCCTAACTAATAAACAATTC-3ʹ 400 nmol/l
A.salmon-143-R 5ʹ-GGCAATGGTTTGTCCTAGGGTC-3ʹ 400 nmol/l
b
A.salmon-143-P 5ʹ-[FAM]-TGGAGAAGTTGTGGGTAAT-[MGB]-3ʹ 200 nmol/l
a
PCR product = 14121 - AACTTGCATC CCTAACTAAT AAACAATTCA AAACTACACC TAATCTCATT ACCCACAACT TCTCCAACAT
GCTAGGATTC TTCCCAGCCA TCATCCACCG ATTAGCCCCC AAACTAAACT TGACCCTAGG ACAAACCATT GCC - 14263 - LC012541.1.
b
FAM: 6-carboxyfluorescein, MGB: Non-fluorescent quencher minor groove binder.
A. salmon-143-F is base pairs 14 121 – 14 149, A. salmon-143-R is base pairs 14 242 – 14 263 and A. salmon-
143-P is 14 168 – 14 186 of LC012541.1, Atlantic salmon ND5 gene. Equivalent reporter dyes and/or quencher
dyes can be used if they yield the same or better results.
6 Apparatus
Requirements concerning apparatus and materials shall follow ISO 20813. The usual laboratory apparatus
and, in particular, the following shall be used.

6.1 Real-time thermocycler instrument.
A device that amplifies DNA in vitro and performs the temperature-time cycles that are needed for PCR.
Additionally, the device shall be capable of exciting fluorescence molecules at specific wavelengths and
2)
detecting sufficient emitted fluorescent light of the fluorophore used to perform TaqMan® format assays.
7 Procedure
7.1 Preparation of the test portion/sample
The test sample used for DNA extraction shall be representative of the laboratory sample and homogeneous
(e.g. by grinding or homogenizing the laboratory sample to a fine mixture). Test portion/sample preparation
shall follow the general requirements and specific methods described in ISO 21571 and ISO 20813.
7.2 Preparation of DNA extracts
The extraction/purification and quantification of DNA from the test portion shall follow the general
requirements and methods provided in ISO 21571. The DNA extraction methods described in ISO 21571:2005
[3]
, Annex A, should be used.
7.3 PCR setup
7.3.1 Reaction mixes
The method is for a total volume of 25 μl per PCR. The reaction setup is given in Table 2. Reagents shall
be completely thawed at room temperature. Each reagent shall be carefully mixed and briefly centrifuged
briefly before pipetting. A PCR reagent mixture is prepared to contain all components except for the sample
DNA. The required total amount of the PCR reagent mixture prepared depends on the number of reactions
to be performed, including a sufficient pipetting reserve. The number of sample and control replicates shall
follow ISO 20813. A minimum of two replicates per sample portion should be prepared. Set up the PCR tests
as follows:
a) mix the PCR reagent mixture, centrifuge briefly and pipette 20 µl into each reaction vial;
b) add 5 µl of each sample DNA or positive DNA target control or extraction blank control or water to the
respective reaction vials;
c) mix and centrifuge briefly.
2) TaqMan® is an example of a suitable products available commercially. This information is given for the convenience
of users of this document and does not constitute an endorsement by ISO of the product named.

Table 2 — Reaction setup for the amplification
Parameter Value
µl
Total reaction volume 25
a
Sample DNA or controls 5
b
2 × PCR master mix 12,5
Primer A.salmon-143-F, c = 10 μmol/l and A.salmon-143-R, c = 10 μmol/l 1,0 for each
Probe A.salmon-143-P, c = 10 μmol/l 0,5
Water to 25
a
The amount of DNA in one reaction can be up to 200 ng, but less than 200 ng per reaction should be used.
b
In the collaborative trial, a ready-to-use optimized 2 × PCR master mix containing all of the components, excluding the
template and primers, was used. The 2 × PCR master mix contains thermostable DNA polymerase, a blend of dNTPs with dUTP
and uracil-UDG to minimize carry-over PCR contamination, and a passive internal reference based on ROX dye. Equivalent
products can be used if they yield the same or better results. If necessary, the amounts of the reagents and the temperature-time
programme can be adapted.
7.3.2 PCR controls
7.3.2.1 General
PCR controls shall be as described in ISO 24276:2006 and ISO 20813:2019.
7.3.2.2 Inhibition control (reference gene assay)
A reference control gene (i.e. 18S rRNA gene for eukaryotes, COI gene for fish) PCR assay using sample DNAs
shall be performed to test nucleic acid amplifiability and provide a control to exclude false-negative results.
7.3.3 Real-time PCR thermocycler plate set-up
Transfer the setup reaction vials to the thermocycler. The vials should be arranged to avoid any possible
edge temperature variations associated with a particular real-time thermocycler instrument. Start the
temperature-time programme.
7.4 Temperature-time programme
The temperature-time programme as outlined in Table 3 was used in the validation study. The use of
different reaction conditions and real-time PCR cycles shall be verified. The time for initial denaturation
depends on the master mix used.
Table 3 — Temperature-time programme
Fluorescence
Step Parameter Temperature Time Cycles
measurement
a
1 UNG activation 50 °C 2 min no 1
2 Initial denaturation 95 °C 10 min no 1
Denaturation 95 °C 15 s no
3 Amplification 45
Annealing and
60 °C 60 s yes
elongation
a
UNG (Uracil-N-Glycosylase) activation is mandatory if UDG-glycosylase is included in mastermix and optional if UDG-
glycosylase is not included in mastermix.

8 Accept/reject criteria
8.1 General
A corresponding real-time PCR-instrument-specific data analysis programme shall be used for the
identification of PCR products. The amplification results can be expressed differently, depending on the
instrument used. In the absence of detectable PCR products (e.g. negative controls), no amplification shall be
detected. If amplification of the DNA target sequence in a sample (e.g. positive controls) occurred, a sigmoid-
shaped amplification curve shall be observed. The cycle number at the crossing point of the amplification
curve and the fluorescence threshold shall be calculated.
If, due to atypical fluorescence measurement data, the automatic interpretation does not provide a
meaningful result, it can be necessary to set the baseline and the threshold manually prior
...


ISO/TC 34/SC 16
ISO/CD TS 20224-12(en)
Secretariat: ANSI
Date: 2026-10-19
Molecular biomarker analysis — Detection of animal-derived
materials in foodstuffs and feedstuffs by real-time PCR —
Part 12:
Atlantic salmon DNA detection method

All rights reserved.
This ISO publication is protected by copyright and is owned by ISO and/or its licensors.
The content of this ISO publication is provided under licence, not sold. Use is subject to the applicable licence terms issued
by ISO, an ISO member body, or an authorized third-party distributor.
Except as required for implementation or expressly permitted by a separate licence, no part of this ISO publication may
be reproduced, distributed, modified, used, or made available in any form or by any means – electronic or mechanical,
including photocopying, scanning, recording, or posting on internal or external digital platforms.
Any use beyond the scope of the granted rights is prohibited and may result in legal action.
ISO copyright office
CP 401 • CH-1214 Vernier, Geneva
Phone: + 41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii
Contents
Foreword . iv
Introduction . v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Scientific basis . 2
5 Reagents and materials . 2
6 Apparatus . 3
7 Procedure . 3
7.1 Preparation of the test portion/sample . 3
7.2 Preparation of DNA extracts . 3
7.3 PCR setup . 3
7.4 Temperature-time programme . 5
8 Accept/reject criteria . 6
8.1 General. 6
8.2 Identification . 6
9 Validation status and performance criteria . 7
9.1 General. 7
9.2 Robustness . 7
9.3 Reproducibility . 7
9.4 Sensitivity . 8
9.5 Specificity . 10
10 Test report . 13
Annex A (informative) Nucleotide basis local alignment tool (BLASTN®) +2.16.1+ results for
query of GenBank® . 14
Annex B (informative) Members of the Salmonidae family and its family tree established with
NCBI Taxonomy . 19
Bibliography . 26

iii
Foreword
This document was prepared by ISO/TC 34, Food products, SC 16, Horizontal methods for molecular
biomarker analysis. For an explanation of the voluntary nature of standards, the meaning of ISO specific terms
and expressions related to conformity assessment, as well as information about ISO's adherence to the World
Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see
www.iso.org/iso/foreword.html. Any trade name used in this document is information given for the
convenience of users and does not constitute an endorsement. ISO draws attention to the possibility that the
implementation of this document may involve the use of (a) patent(s). ISO takes no position concerning the
evidence, validity or applicability of any claimed patent rights in respect thereof. As of the date of publication
of this document, ISO [had/had not] received notice of (a) patent(s) which may be required to implement this
document. However, implementers are cautioned that this may not represent the latest information, which
may be obtained from the patent database available at www.iso.org/patents. ISO shall not be held responsible
for identifying any or all such patent rights. The procedures used to develop this document and those intended
for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular, the different approval
criteria needed for the different types of ISO document should be noted. This document was drafted in
accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives). ISO (the
International Organization for Standardization) is a worldwide federation of national standards bodies (ISO
member bodies). The work of preparing International Standards is normally carried out through ISO technical
committees. Each member body interested in a subject for which a technical committee has been established
has the right to be represented on that committee. International organizations, governmental and non-
governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International
Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. The procedures used to
develop this document and those intended for its further maintenance are described in the ISO/IEC Directives,
Part 1. In particular, the different approval criteria needed for the different types of ISO document should be
noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see
www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed patent rights
in respect thereof. As of the date of publication of this document, ISO had not received notice of (a) patent(s)
which may be required to implement this document. However, implementers are cautioned that this may not
represent the latest information, which may be obtained from the patent database available at
www.iso.org/patents. ISO shall not be held responsible for identifying any or all such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement. For an explanation of the voluntary nature of standards, the meaning of ISO
specific terms and expressions related to conformity assessment, as well as information about ISO's adherence
to the World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see
www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 34, Food products, Subcommittee SC 16,
Horizontal methods for molecular biomarker analysis.
A list of all parts in the ISO 20224 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.
iv
Introduction
Fraudulent adulteration of meat in food and feed threatens both public safety and commerce. Adulteration
can affect those adhering to ethnological dietary rules, economic development and social stability. This
document provides a real-time polymerase chain reaction (real-time PCR) analytical method for the
identification of meat animal species from nucleic acid present in the ingredients of food and feed.
Animal-derived biological materials in food and feed are detected and identified in the laboratory with the
following successive (or simultaneous) steps:
— preparation of the test portion/sample, ;
— nucleic acid extraction and purification, ;
— PCR amplification and interpretation of results.
This document provides guidance for PCR amplification and interpretation of results, specific to Atlantic
salmon (Salmo salar) DNA detection.
[1]
The ISO20224ISO 20224 series consists of documents that describe specific applications. New species DNA
detection methods established in the future will be added as independent parts.
Identification of patent holders: the following text shall be included if patent rights have been identified.
The International Organization for Standardization (ISO) [and/or] International Electrotechnical Commission
(IEC) draw[s] attention to the fact that it is claimed that compliance with this document may involve the use
of a patent.
ISO [and/or] IEC take[s] no position concerning the evidence, validity and scope of this patent right.
The holder of this patent right has assured ISO [and/or] IEC that he/she is willing to negotiate licences under
reasonable and non-discriminatory terms and conditions with applicants throughout the world. In this
respect, the statement of the holder of this patent right is registered with ISO [and/or] IEC. Information may
be obtained from the patent database available at .
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights other than those in the patent database. ISO [and/or] IEC shall not be held responsible for identifying
any or all such patent rights.
v
Molecular biomarker analysis — Detection of animal-derived
materials in foodstuffs and feedstuffs by real-time PCR —
Part 12:
Atlantic salmon DNA detection method
1 Scope
This document specifies a real-time polymerase chain reaction (real-time PCR) method for the qualitative
detection of Atlantic salmon (Salmo salar)-specific DNA derived from food and feed.
It requires the extraction of an adequate amount of PCR amplifiable DNA from the relevant matrix and can be
applied to detection of Atlantic salmon material.
The target sequence is a partial fragment of the Atlantic salmon NADH dehydrogenase subunit 5 (ND5) gene
1) [2]
(i.e. GenBank® accession number LC012541.1) from the mitochondrial genome of Atlantic salmon. The
provided PCR assay for this target has an absolute limit of detection of 5five copies per reaction, with ≥ 95 %
confidence at this concentration (LOD ).
95 %
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
ISO 16577:2022, Molecular biomarker analysis — Vocabulary for molecular biomarker analytical methods in
agriculture and food production
ISO 20813, Molecular biomarker analysis — Methods of analysis for the detection and identification of animal
species in foods and food products (nucleic acid-based methods) — General requirements and definitions
ISO 20813:2019, Molecular biomarker analysis — Methods of analysis for the detection and identification of
animal species in foods and food products (nucleic acid-based methods) — General requirements and definitions
ISO 21571:2005, Foodstuffs — Methods of analysis for the detection of genetically modified organisms and
derived products — Nucleic acid extraction
ISO 24276:2006, Foodstuffs — Methods of analysis for the detection of genetically modified organisms and
derived products — General requirements and definitions
3 Terms and definitions
For the purposes of this document, the following terms and definitions / terms and definitions given in ISO
ISO 16577:2022 apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:

1)
GenBank® is an example of a suitable product available commercially. This information is given for the convenience of
users of this document and does not constitute an endorsement by ISO of this product. Equivalent products may be used
if they can be shown to lead to the same results.

— IEC Electropedia: available at ISO Online browsing platform: available at https://www.iso.org/obp
3.1
Atlantic salmon, noun
a of ray-finned fish in the family . It is the third largest of the Salmonidae, behind and Pacific , growing up to
a meter in length. Atlantic salmon are found in the and in rivers that flow into it. Most populations are
anadromous: they hatch in streams and rivers, migrate to the ocean to grow and mature, and then return
seasonally to swim upstream and spawn.
— IEC Electropedia: available at https://www.electropedia.org/
4 Scientific basis
[3]
DNA is extracted from the test portion by applying a suitable method (see ISO 21571:2005 ISO 21571:2005
,, Clause A.1). The DNA analysis consists of two parts:
— verification of the quality and amplifiability of the extracted DNA using a PCR assay specific for eukaryotes
(i.e. 18S rRNA gene) or fish (i.e. COI gene);
— detection of the Atlantic salmon species-specific DNA sequence of the ND5 gene (i.e. GenBank® accession
number LC012541.1) in a real-time PCR.
NOTE The use of a mitochondrial marker gene as a PCR target offers greater sensitivity due to the presence of
multiple mitochondria per cell but also makes quantification challenging or even impossible due to the variability in
mitochondrial numbers per cell.
5 Reagents and materials
5.1 General
For this document, onlyOnly reagents and water of recognized analytical grade, appropriate for molecular
biology, shall be used. Unless stated otherwise, solutions shall be prepared by dissolving the corresponding
reagents in water followed by autoclave sterilization. For all operations in which gloves are used, gloves shall
be powder free. The use of aerosolAerosol-protected pipette tips (protection against cross-contamination) is
mandatoryshall be used.
5.2 PCR reagents
5.35.1 PCR master mix.
In general, the real-time PCR master mix contains thermostable DNA polymerase, dNTPs, MgCl , KCl and buffer
as a dilutable concentrated mixture, that is ready to use.
NOTE  Commercial A commercial real-time PCR master mix can be used.
5.45.2 Oligonucleotides.
The quality of the oligonucleotides shall be sufficient for their use as primers and probes. See Table 1.
Table 1 — Oligonucleotides
Name DNA sequence of the oligonucleotide Final concentration in
PCR
a
Atlantic salmon ND5 gene as the target sequence (GenBank® accession number LC012541.1)
A.salmon-143-F 5′-5ʹ-AACTTGCATCCCTAACTAATAAACAATTC-3′3ʹ 400 nmol/l
Name DNA sequence of the oligonucleotide Final concentration in
PCR
A.salmon-143-R 5′-5ʹ-GGCAATGGTTTGTCCTAGGGTC-3′3ʹ 400 nmol/l
b b
A.salmon-143-P 5′-[5ʹ-[FAM]-TGGAGAAGTTGTGGGTAAT-[MGB] -3′]-3ʹ 200 nmol/l
a
PCR product = 14121 - AACTTGCATC CCTAACTAAT AAACAATTCA AAACTACACC TAATCTCATT ACCCACAACT TCTCCAACAT
GCTAGGATTC TTCCCAGCCA TCATCCACCG ATTAGCCCCC AAACTAAACT TGACCCTAGG ACAAACCATT GCC - 14263 - LC012541.1.
b
FAM: 6-carboxyfluorescein, MGB: Non-fluorescent quencher minor groove binder.
A. salmon-143-F is base pairs 14 121 – 14 149, A. salmon-143-R is base pairs 14 242 – 14 263 and A. salmon-
143-P is 14 168 – 14 186 of LC012541.1, Atlantic salmon ND5 gene. Equivalent reporter dyes and/or quencher
dyes can be used if they yield the same or better results.
6 Apparatus
Requirements concerning apparatus and materials shall follow ISO 20813. In addition to theThe usual
laboratory equipmentapparatus and, in particular, the following equipment is requiredshall be used.
6.1 Real-time thermocycler instrument.
A device that amplifies DNA in vitro and performs the temperature-time cycles that are needed for PCR.
Additionally, the device shall be capable of exciting fluorescence molecules at specific wavelengths and
12)
detecting sufficient emitted fluorescent light of the fluorophore used to perform TaqMan® format assays.
7 Procedure
7.1 Preparation of the test portion/sample
The test sample used for DNA extraction shall be representative of the laboratory sample and homogeneous,
(e.g. by grinding or homogenizing the laboratory sample to a fine mixture.). Test portion/sample preparation
shall follow the general requirements and specific methods described in ISO 21571 and ISO 20813.
7.2 Preparation of DNA extracts
The extraction/purification and quantification of DNA from the test portion shall follow the general
requirements and methods provided in ISO 21571. The DNA extraction methods described in ISO
[3]
21571:2005 ISO 21571:2005,, Annex A, are recommendedshould be used.
7.3 PCR setup
7.3.1 Reaction mixes
The method is for a total volume of 25 μl per PCR. The reaction setup is given in Table 2. Reagents shall be
completely thawed at room temperature. Each reagent shall be carefully mixed and briefly centrifuged briefly
before pipetting. A PCR reagent mixture is prepared to contain all components except for the sample DNA. The
required total amount of the PCR reagent mixture prepared depends on the number of reactions to be
performed, including a sufficient pipetting reserve. The number of sample and control replicates shall follow

1)
TaqMan® is an example of a suitable products available commercially. This information is given for the convenience
of users of this document and does not constitute an endorsement by ISO of the products named.

2)
TaqMan® is an example of a suitable products available commercially. This information is given for the convenience
of users of this document and does not constitute an endorsement by ISO of the product named.

ISO 20813. A minimum of two replicates per sample portion should be prepared. Set up the PCR tests as
follows:
a) mix the PCR reagent mixture, centrifuge briefly and pipette 20 µl into each reaction vial;
b) add 5 µl of each sample DNA or positive DNA target control or extraction blank control or water to the
respective reaction vials;
c) mix and centrifuge briefly.

Table 2 — Reaction setup for the amplification
Parameter Value
µl
Total reaction volume 25 µl
a
Sample DNA or controls 5 µl
b
2 × PCR master mix 12,5 µl
Primer A.salmon-143-F, c = 10 μmol/l and A.salmon-143-R, c = 10 μmol/l 1,0 µl for each
Probe A.salmon-143-P, c = 10 μmol/l 0,5 µl
Water to 25 µl
a
The amount of DNA in one reaction can be up to 200 ng, but the recommendation amount is less than 200 ng per reaction
should be used.
b
In the collaborative trial, a ready-to-use optimized 2 × PCR master mix containing all of the components, excluding the template
and primers, was used. The 2 × PCR master mix contains thermostable DNA polymerase, a blend of dNTPs with dUTP and uracil-
UDG to minimize carry-over PCR contamination, and a passive internal reference based on ROX dye. Equivalent products can be
used if they yield the same or better results. If necessary, the amounts of the reagents and the temperature-time programme can
be adapted.
7.3.2 PCR Controlscontrols
7.3.2.1 General
PCR controls shall be as described in ISO 24276:2006 and ISO 20813:2019.
7.3.2.2 Inhibition control (reference gene assay)
A reference control gene (i.e. 18S rRNA gene for eukaryotes, COI gene for fish) PCR assay using sample DNAs
shall be performed to test nucleic acid amplifiability and provide a control to exclude false-negative results.
7.3.3 Real-time PCR thermocycler plate set-up
Transfer the setup reaction vials to the thermocycler. The vials should be arranged to avoid any possible edge
temperature variations associated with a particular real-time thermocycler instrument. Start the
temperature-time programme.
7.4 Temperature-time programme
The temperature-time programme as outlined in Table 3 was used in the validation study. The use of different
reaction conditions and real-time PCR cycles shall be verified. The time for initial denaturation depends on
the master mix used.
Table 3 — Temperature-time programme
Fluorescence
Step Parameter Temperature Time measuremen Cycles
t
a
1 UNG activation 50 °C 2 min no 1
2 Initial denaturation 95 °C 10 min no 1
Denaturation 95 °C 15 s no
3 Amplification 45
Annealing and
60 °C 60 s yes
elongation
a
UNG (Uracil-N-Glycosylase) activation is mandatory if UDG-glycosylase is included in mastermix and optional if UDG-
glycosylase is not included in mastermix.
8 Accept/Reject Criteriareject criteria
8.1 General
A corresponding real-time PCR-instrument-specific data analysis programme shall be used for the
identification of PCR products. The amplification results can be expressed differently, depending on the
instrument used. In the absence of detectable PCR products (e.g. negative controls), no amplification shall be
detected. If amplification of the DNA target sequence in a sample (e.g. positive controls) occurred, a sigmoid-
shaped amplification curve shall be observed. The cycle number at the crossing point of the amplification
curve and the fluorescence threshold shall be calculated.
If, due to atypical fluorescence measurement data, the automatic interpretation does not provide a meaningful
result, it maycan be necessary to set the baseline and the threshold manually prior to interpreting the data. In
such a case, the device-specific instructions provided with the interpretation software shall be followed.
8.2 Identification
The target sequence is considered as detected if:
— Atlantic salmon-specific primers A.salmon-143-F and A.salmon-143-R, along with the probe A.salmon-