Acoustics — Reference zero for the calibration of audiometric equipment — Part 7: Reference threshold of hearing under free-field and diffuse-field listening conditions

ISO 389-7:2005 specifies a reference threshold of hearing for the calibration of audiometric equipment used under the following conditions. The sound field in the absence of the listener consists of either a free progressive plane wave (free field) or a diffuse sound field, as specified in ISO 8253-2. In the case of a free field, the source of sound is directly in front of the listener (frontal incidence). The sound signals are pure (sinusoidal) tones in the case of free-field conditions and one-third octave bands of (white or pink) noise in the case of diffuse-field conditions. The sound pressure level is measured in the absence of the listener at the position where the centre of the listener's head would be. Listening is binaural. The data in ISO 389-7:2005 are given in numerical form for the preferred frequencies in the one-third octave series from 20 Hz to 16 000 Hz inclusive in accordance with ISO 266 and, in addition, for some intermediate audiometric frequencies up to 18 000 Hz. The threshold data differ from the audiometric zero specified in ISO 389-1, ISO 389-2, ISO/TR 389-5 and ISO 389-8, since the latter refer to monaural listening through earphones with sound pressure levels referred to specified couplers and ear simulators. Direct comparison between the data in the parts of ISO 389 mentioned above and that in ISO 389-7:2005 is therefore not appropriate.

Acoustique — Zéro de référence pour l'étalonnage d'équipements audiométriques — Partie 7: Niveau liminaire de référence dans des conditions d'écoute en champ libre et en champ diffus

L'ISO 389-7:2005 spécifie un seuil d'audition de référence pour l'étalonnage des équipements audiométriques utilisés dans les conditions suivantes. Le champ acoustique en l'absence de l'auditeur consiste soit en une onde plane progressive libre (champ libre), soit en un champ acoustique diffus, tel qu'il est spécifié dans l'ISO 8253-2. Dans le cas d'un champ libre, la source sonore se trouve directement en face de l'auditeur (incidence frontale). Les signaux sonores sont des sons purs (sinusoïdaux) dans le cas des conditions en champ libre et des bandes de tiers d'octave de bruit (blanc ou rose) dans le cas des conditions en champ diffus. Le niveau de pression acoustique est mesuré, en l'absence de l'auditeur, à la position qu'aurait dû occuper le centre de sa tête. L'écoute est binaurale. Les données dans l'ISO 389-7:2005 sont présentées sous forme numérique pour les fréquences normales dans la série du tiers d'octave de 20 Hz à 16 000 Hz inclus, conformément à l'ISO 266 et, en plus, pour certaines fréquences audiométriques intermédiaires jusqu'à 18 000 Hz. Il convient de souligner que les données concernant le seuil d'audition diffèrent du zéro audiométrique spécifié dans l'ISO 389-1, l'ISO 389-2, l'ISO/TR 389-5 et l'ISO 389-8, étant donné que ces dernières concernent l'écoute monaurale par écouteurs, les niveaux de pression acoustique étant mesurés sur des coupleurs et des oreilles artificielles spécifiés. Une comparaison directe entre les données figurant dans les parties de l'ISO 389 mentionnées plus haut et les données de la présente partie de l'ISO 389 n'est donc pas appropriée.

General Information

Status
Withdrawn
Publication Date
02-Nov-2005
Withdrawal Date
02-Nov-2005
Technical Committee
Current Stage
9599 - Withdrawal of International Standard
Completion Date
05-Nov-2019
Ref Project

Relations

Buy Standard

Standard
ISO 389-7:2005 - Acoustics -- Reference zero for the calibration of audiometric equipment
English language
10 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 389-7:2005 - Acoustique -- Zéro de référence pour l'étalonnage d'équipements audiométriques
French language
10 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 389-7
Second edition
2005-11-01


Acoustics — Reference zero for the
calibration of audiometric equipment —
Part 7:
Reference threshold of hearing under
free-field and diffuse-field listening
conditions
Acoustique — Zéro de référence pour l'étalonnage d'équipements
audiométriques —
Partie 7: Niveau liminaire de référence dans des conditions d'écoute en
champ libre et en champ diffus





Reference number
ISO 389-7:2005(E)
©
ISO 2005

---------------------- Page: 1 ----------------------
ISO 389-7:2005(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.


©  ISO 2005
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland

ii © ISO 2005 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 389-7:2005(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 389-7 was prepared by Technical Committee ISO/TC 43, Acoustics.
This second edition cancels and replaces the first edition (ISO 389-7:1996), which has been technically
revised.
ISO 389 consists of the following parts, under the general title Acoustics — Reference zero for the calibration
of audiometric equipment:
⎯ Part 1: Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones
⎯ Part 2: Reference equivalent threshold sound pressure levels for pure tones and insert earphones
⎯ Part 3: Reference equivalent threshold force levels for pure tones and bone vibrators
⎯ Part 4: Reference levels for narrow-band masking noise
⎯ Part 5: Reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz
to 16 kHz
⎯ Part 6: Reference hearing threshold levels for test signals of short duration
⎯ Part 7: Reference threshold of hearing under free-field and diffuse-field listening conditions
⎯ Part 8: Reference equivalent threshold sound pressure levels for pure tones and circumaural earphones
© ISO 2005 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO 389-7:2005(E)
Introduction
In some audiological applications the test signals are delivered by means of loudspeakers, either in a free
sound field or in a diffuse sound field. This part of ISO 389 specifies the reference zero for the calibration of
audiometric equipment used for sound field audiometry. Corresponding audiometric test methods are
specified in ISO 8253-1 and ISO 8253-2.
In common with other subjective phenomena, the threshold of hearing varies in detail from person to person
but, for a group of otologically normal persons within a restricted age range, values for the central tendency
can be determined to characterize the group. This and other parts of ISO 389 specify threshold data
applicable to otologically normal persons in the age range from 18 years to 25 years.
The data specified in this part of ISO 389 relate to
a) pure tones heard under conditions of binaural listening in free progressive plane waves with the subject
directly facing the source of sound (frontal incidence), and with the sound pressure level measured in the
free progressive wave at the centre position of the listener's head with the listener absent;
b) one-third-octave bands of (white or pink) noise heard under conditions of binaural listening in a diffuse
sound field with the sound pressure level measured in the sound field at the centre position of the
listener's head with the listener absent.
For frequencies up to 8 kHz, each set of data may be equally applied to any other bands of (white or pink)
noise for which the bandwidth is less than the critical bandwidth.
The data are based on an assessment of technical information provided by laboratories in different countries
representing the most reliable data available at the time. For information, a note on the derivation of the
reference values and the origin of the data is given in Annex A.

iv © ISO 2005 – All rights reserved

---------------------- Page: 4 ----------------------
INTERNATIONAL STANDARD ISO 389-7:2005(E)

Acoustics — Reference zero for the calibration of audiometric
equipment —
Part 7:
Reference threshold of hearing under free-field and diffuse-field
listening conditions
1 Scope
This part of ISO 389 specifies a reference threshold of hearing for the calibration of audiometric equipment
used under the following conditions.
a) The sound field in the absence of the listener consists of either a free progressive plane wave (free field)
or a diffuse sound field, as specified in ISO 8253-2. In the case of a free field, the source of sound is
directly in front of the listener (frontal incidence).
b) The sound signals are pure (sinusoidal) tones in the case of free-field conditions and one-third octave
bands of (white or pink) noise in the case of diffuse-field conditions.
c) The sound pressure level is measured in the absence of the listener at the position where the centre of
the listener's head would be.
d) Listening is binaural.
NOTE 1 Correction values for the threshold of hearing under free-field listening conditions and selected angles of
sound incidence (45° and 90°) deviating from frontal incidence are given in ISO 8253-2 for information.
NOTE 2 Other conditions are given in Bibliographic Reference [1].
The data are given in numerical form for the preferred frequencies in the one-third-octave series from 20 Hz to
16 000 Hz inclusive in accordance with ISO 266 and, in addition, for some intermediate audiometric
frequencies up to 18 000 Hz.
It should be emphasized that the threshold data differ from the audiometric zero specified in ISO 389-1,
ISO 389-2, ISO/TR 389-5 and ISO 389-8, since the latter refer to monaural listening through earphones with
sound pressure levels referred to specified couplers and ear simulators. Direct comparison between the data
in the parts of ISO 389 mentioned above and in this part of ISO 389 is therefore not appropriate.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 8253-2, Acoustics — Audiometric test methods — Part 2: Sound field audiometry with pure tone and
narrow-band test signals
© ISO 2005 – All rights reserved 1

---------------------- Page: 5 ----------------------
ISO 389-7:2005(E)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
threshold of hearing
level of a sound at which, under specified conditions, a person gives 50 % of correct detection responses on
repeated trials
NOTE The results of threshold determination depend to a certain degree on the test procedure used. The data
presented in the ISO 389 series are all based on the use of the threshold test procedures defined in ISO 8253-1. When a
test procedure with other characteristics is used, differences of up to several decibels on average may be expected.
3.2
otologically normal person
person in a normal state of health who is free from all signs or symptoms of ear disease and from obstructing
wax in the ear canals, and who has no history of undue exposure to noise, exposure to potentially ototoxic
drugs, or familial hearing loss
3.3
reference threshold of hearing
at a specified frequency, the sound pressure level of a pure tone or a one-third-octave band of noise
corresponding to the median value of the binaural thresholds of hearing of otologically normal persons within
the age limits from 18 years to 25 years inclusive
3.4
free sound field
sound field where the boundaries of the room exert a negligible effect on the sound waves
3.5
diffuse sound field
sound field consisting of sound waves arriving at a given location more or less simultaneously from all
directions with equal probability and level
4 Specification
The reference thresholds of hearing for the listening conditions specified in Clause 1 are given in Table 1. This
table also gives the differences between sound pressure levels of one-third-octave bands of noise in a diffuse
sound field and the sound pressure levels of pure tones in a frontally incident free progressive wave for equal
thresholds of hearing. A graphical illustration of the reference thresholds of hearing is given in Figure 1.
2 © ISO 2005 – All rights reserved

---------------------- Page: 6 ----------------------
ISO 389-7:2005(E)
Table 1 — Reference thresholds of hearing for the listening conditions specified in Clause 1
and differences between sound pressure levels in the two types of sound field
Frequency Reference threshold of hearing under the condition of Difference
free-field listening diffuse-field listening
(frontal incidence)
f
T (ref. 20 µPa) T' (ref. 20 µPa) ∆L = T – T'
f f f f
Hz dB dB dB
a
20 78,5 78,5 0
25 68,7 68,7 0
31,5 59,5 59,5 0
40 51,1 51,1 0
50 44,0 44,0 0
63 37,5 37,5 0
80 31,5 31,5 0
100 26,5 26,5 0
125 22,1 22,1 0
160 17,9 17,9 0
200 14,4 14,4 0
250 11,4 11,4 0
315 8,6 8,4 0,2
400 6,2 5,8 0,4
500 4,4 3,8 0,6
630 3,0 2,1 0,9
750 2,4 1,2 1,2
800 2,2 1,0 1,2
1 000 2,4 0,8 1,6
1 250 3,5 1,9 1,6
1 500 2,4 1,0 1,4
1 600 1,7 0,5 1,2
2 000 –1,3 –1,5 0,2
...

NORME ISO
INTERNATIONALE 389-7
Deuxième édition
2005-11-01


Acoustique — Zéro de référence
pour l'étalonnage d'équipements
audiométriques —
Partie 7:
Niveau liminaire de référence dans des
conditions d'écoute en champ libre et en
champ diffus
Acoustics — Reference zero for the calibration of audiometric
equipment —
Part 7: Reference threshold of hearing under free-field and diffuse-field
listening conditions





Numéro de référence
ISO 389-7:2005(F)
©
ISO 2005

---------------------- Page: 1 ----------------------
ISO 389-7:2005(F)
PDF – Exonération de responsabilité
Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier
peut être imprimé ou visualisé, mais ne doit pas être modifié à moins que l'ordinateur employé à cet effet ne bénéficie d'une licence
autorisant l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées
acceptent de fait la responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute
responsabilité en la matière.
Adobe est une marque déposée d'Adobe Systems Incorporated.
Les détails relatifs aux produits logiciels utilisés pour la création du présent fichier PDF sont disponibles dans la rubrique General Info
du fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir
l'exploitation de ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation,
veuillez en informer le Secrétariat central à l'adresse donnée ci-dessous.


©  ISO 2005
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous
quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit
de l'ISO à l'adresse ci-après ou du comité membre de l'ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax. + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse

ii © ISO 2005 – Tous droits réservés

---------------------- Page: 2 ----------------------
ISO 389-7:2005(F)
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée
aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du
comité technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec
la Commission électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI,
Partie 2.
La tâche principale des comités techniques est d'élaborer les Normes internationales. Les projets de Normes
internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur
publication comme Normes internationales requiert l'approbation de 75 % au moins des comités membres
votants.
L'attention est appelée sur le fait que certains des éléments du présent document peuvent faire l'objet de
droits de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable de ne
pas avoir identifié de tels droits de propriété et averti de leur existence.
L'ISO 389-7 a été élaborée par le comité technique ISO/TC 43, Acoustique.
Cette deuxième édition annule et remplace la première édition (ISO 389-7:1996), qui a fait l'objet d'une
révision technique.
L'ISO 389 comprend les parties suivantes, présentées sous le titre général Acoustique — Zéro de référence
pour l'étalonnage d'équipements audiométriques:
⎯ Partie 1: Niveaux de référence équivalents de pression acoustique liminaire pour les écouteurs à sons
purs supra-auraux
⎯ Partie 2: Niveaux de référence équivalents de pression acoustique liminaire pour les écouteurs à sons
purs et à insertion
⎯ Partie 3: Niveaux de référence équivalents de force liminaire pour les vibrateurs à sons purs et les
ossivibrateurs
⎯ Partie 4: Niveaux de référence pour bruit de masque en bande étroite
⎯ Partie 5: Niveaux de référence équivalents de pression acoustique liminaire pour les sons purs dans le
domaine de fréquences de 8 kHz à 16 kHz
⎯ Partie 6: Niveaux liminaires de référence dans des conditions d'écoute avec signaux d'essai de courte
durée
⎯ Partie 7: Niveau liminaire de référence dans des conditions d'écoute en champ libre et en champ diffus
⎯ Partie 8: Niveaux de référence équivalents de pression acoustique liminaire pour les écouteurs à sons
purs circumauraux

© ISO 2005 – Tous droits réservés iii

---------------------- Page: 3 ----------------------
ISO 389-7:2005(F)
Introduction
Dans certaines applications audiologiques, les signaux d’essai sont transmis au moyen de haut-parleurs, soit
dans un champ acoustique libre, soit dans un champ acoustique diffus. La présente partie de l’ISO 389
spécifie le zéro de référence pour l’étalonnage d’équipements audiométriques utilisés en audiométrie en
champ acoustique. Les méthodes d’essai audiométriques correspondantes sont spécifiées dans l’ISO 8253-1
et l’ISO 8253-2.
Tout comme pour d’autres phénomènes subjectifs, le seuil d’audition varie légèrement d’une personne à
l’autre mais, pour un groupe de sujets otologiquement normaux et dans une tranche d’âges limitée, les
valeurs de la tendance centrale peuvent être déterminées pour caractériser le groupe. La présente partie et
d’autres parties de l’ISO 389 spécifient les données liminaires applicables à des sujets otologiquement
normaux âgés de 18 ans à 25 ans.
Les données spécifiées dans la présente partie de l’ISO 389 concernent les aspects suivants:
a) des sons purs entendus dans des conditions d’écoute binaurale d’ondes planes progressives libres, le
sujet faisant directement face à la source sonore (incidence frontale), et le niveau de pression acoustique
étant mesuré sur l’onde progressive libre à la position du centre de la tête de l’auditeur, celui-ci étant
absent;
b) des bandes de tiers d’octave de bruit (blanc ou rose) entendues dans des conditions d’écoute binaurale
dans un champ acoustique diffus, le niveau de pression acoustique étant mesuré dans le champ
acoustique à la position du centre de la tête de l’auditeur, celui-ci étant absent.
Pour les fréquences jusqu’à 8 kHz, chaque ensemble de données peut également s’appliquer à toutes les
autres bandes de bruit (blanc ou rose) dont la bande passante est inférieure à la largeur de la bande critique.
Les données sont fondées sur une évaluation des informations techniques fournies par des laboratoires de
différents pays, représentant les données les plus fiables disponibles à ce moment. Pour information, une
note sur l’obtention des valeurs de référence et l’origine des données est indiquée à l’Annexe A.

iv © ISO 2005 – Tous droits réservés

---------------------- Page: 4 ----------------------
NORME INTERNATIONALE ISO 389-7:2005(F)

Acoustique — Zéro de référence pour l'étalonnage
d'équipements audiométriques —
Partie 7:
Niveau liminaire de référence dans des conditions d'écoute
en champ libre et en champ diffus
1 Domaine d'application
La présente partie de l’ISO 389 spécifie un seuil d’audition de référence pour l’étalonnage des équipements
audiométriques utilisés dans les conditions suivantes.
a) Le champ acoustique en l’absence de l’auditeur consiste soit en une onde plane progressive libre (champ
libre), soit en un champ acoustique diffus, tel qu’il est spécifié dans l’ISO 8253-2. Dans le cas d’un champ
libre, la source sonore se trouve directement en face de l’auditeur (incidence frontale).
b) Les signaux sonores sont des sons purs (sinusoïdaux) dans le cas des conditions en champ libre et des
bandes de tiers d’octave de bruit (blanc ou rose) dans le cas des conditions en champ diffus.
c) Le niveau de pression acoustique est mesuré, en l’absence de l’auditeur, à la position qu’aurait dû
occuper le centre de sa tête.
d) L’écoute est binaurale.
NOTE 1 Les valeurs de correction relatives au seuil d’audition dans des conditions d’écoute en champ libre et selon
des angles d’incidence sélectionnés (45° et 90°) s’écartant de l’incidence frontale sont données dans l’ISO 8253-2 pour
information.
NOTE 2 Les autres conditions sont dans la mesure du possible celles spécifiées dans la Référence [1] de la
Bibliographie.
Les données sont présentées sous forme numérique pour les fréquences normales dans la série du tiers
d’octave de 20 Hz à 16 000 Hz inclus, conformément à l’ISO 266 et, en plus, pour certaines fréquences
audiométriques intermédiaires jusqu’à 18 000 Hz.
Il convient de souligner que les données concernant le seuil d’audition diffèrent du zéro audiométrique
spécifié dans l’ISO 389-1, l’ISO 389-2, l’ISO/TR 389-5 et l’ISO 389-8, étant donné que ces dernières
concernent l’écoute monaurale par écouteurs, les niveaux de pression acoustique étant mesurés sur des
coupleurs et des oreilles artificielles spécifiés. Une comparaison directe entre les données figurant dans les
parties de l’ISO 389 mentionnées plus haut et les données de la présente partie de l’ISO 389 n’est donc pas
appropriée.
© ISO 2005 – Tous droits réservés 1

---------------------- Page: 5 ----------------------
ISO 389-7:2005(F)
2 Références normatives
Les documents de référence suivants sont indispensables pour l'application du présent document. Pour les
références datées, seule l'édition citée s'applique. Pour les références non datées, la dernière édition du
document de référence s'applique (y compris les éventuels amendements).
ISO 8253-2, Acoustique — Méthodes d’essais audiométriques — Partie 2: Audiométrie en champ acoustique
avec des sons purs et des bruits à bande étroite comme signaux d’essai
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions suivants s'appliquent.
3.1
seuil d’audition
niveau d’un son pour lequel, dans des conditions spécifiées, un sujet donne 50 % de réponses correctes de
détection au cours d’essais répétés
NOTE Les résultats de la détermination du seuil dépendent à un certain degré de la méthode d’essai utilisée. Les
données présentées dans la série de normes ISO 389 sont toutes basées sur l’utilisation des méthodes d’essai de seuil
définies dans l’ISO 8253-1. Lorsqu’une méthode d’essai ayant d’autres caractéristiques est utilisée, des différences
pouvant atteindre plusieurs décibels en moyenne sont à prévoir.
3.2
sujet otologiquement normal
personne en bonne santé, ne présentant aucun signe ou symptôme d’affections otologiques, dont le conduit
auditif externe n’est pas obstrué par du cérumen, qui n’a subi antérieurement aucune exposition anormale au
bruit, qui ne prend pas de médicaments potentiellement ototoxiques et qui n’a pas d’antécédents familiaux de
perte auditive
3.3
seuil d’audition de référence
à une fréquence donnée, niveau de pression acoustique d’un son pur ou d’une bande de tiers d’octave de
bruit, correspondant à la valeur médiane des seuils d’audition binauraux de sujets otologiquement normaux,
âgés de 18 ans à 25 ans
3.4
champ acoustique libre
champ acoustique pour lequel les limites de la pièce ont un effet négligeable sur les ondes sonores
3.5
champ acoustique diffus
champ acoustique consistant en ondes sonores arrivant à un endroit donné et provenant plus ou moins
simultanément de toutes les directions, avec la même probabilité et le même niveau
4 Spécification
Les seuils d’audition de référence pour les conditions d’écoute spécifiées à l’Article 1 sont donnés dans le
Tableau 1. Ce tableau donne également les différences entre les niveaux de pression acoustique de bandes
de tiers d’octave de bruit en champs diffus, et les niveaux de pression acoustique de sons purs à incidence
frontale en champ libre, pour les mêmes seuils d’audition. Une illustration graphique des seuils d’audition de
référence est donnée à la Figure 1.
2 © ISO 2005 – Tous droits réservés

---------------------- Page: 6 ----------------------
ISO 389-7:2005(F)
Tableau 1 — Seuils d'audition de référence pour les conditions d'écoute spécifiées à l'article 1 et
différence entre les niveaux de pression acoustique des deux types de champ acoustique
Seuil d’audition de référence pour
Fréquence Différence
écoute en champ libre
écoute en champ diffus
(incidence frontale)
f T (réf. 20 µPa) T’ (réf. 20 µPa) ∆L = T – T’
f f f f
Hz dB dB dB
a
20 78,5 78,5 0
25 68,7 68,7 0
31,5 59,5 59,5 0

40 51,1 51,1 0
50 44,0 44,0 0
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.