ISO 24682:2024
(Main)Ships and marine technology — Technical requirements for "B" class fire-resistant compartment systems of composite mineral wool panel
Ships and marine technology — Technical requirements for "B" class fire-resistant compartment systems of composite mineral wool panel
This document provides requirements on fire resistance, acoustic insulation, opening and penetration for “B” class fire-resistant compartment systems made of composite mineral wool panel, which are aligned with the 2010 FTP Code and SOLAS 74 and its amendments. This document also specifies how these “B” class fire-resistant compartment systems are inspected. This document is applicable to accommodation spaces made by “B” class composite mineral wool panels for ships and offshore installations where “B” class divisions are required.
Navires et technologie maritime — Exigences techniques pour les systèmes de compartiments résistants aux feux de classe B en panneaux composites de laine minérale
General Information
Standards Content (Sample)
International
Standard
ISO 24682
First edition
Ships and marine technology —
2024-09
Technical requirements for "B" class
fire-resistant compartment systems
of composite mineral wool panel
Navires et technologie maritime — Exigences techniques pour
les systèmes de compartiments résistants aux feux de classe B en
panneaux composites de laine minérale
Reference number
© ISO 2024
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on
the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below
or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Requirements . 2
4.1 Materials .2
4.2 Fire resistance .3
4.3 Acoustic insulation .11
4.4 Opening in “B” class division . 12
4.4.1 Opening for “B” class fire door . 12
4.4.2 Opening for window or balcony door . 12
4.4.3 Other openings . 12
4.5 Penetration . 12
4.5.1 General . 12
4.5.2 Pipes . 13
4.5.3 Ventilation ducts . . 13
4.5.4 Electric cables . 13
4.6 Tolerance requirements . 13
4.7 Appearance . 15
5 Inspection .15
5.1 Materials . 15
5.2 Fire resistance .16
5.3 Acoustic insulation .16
5.4 Opening .16
5.5 Penetration .16
5.6 Installation tolerance .16
5.7 Appearance .16
Annex A (informative) “B” class composite mineral wool panel . 17
Annex B (informative) Typical connection and installation details .18
Annex C (informative) Typical construction of penetrations .24
Bibliography .31
iii
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out through
ISO technical committees. Each member body interested in a subject for which a technical committee
has been established has the right to be represented on that committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely
with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are described
in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types
of ISO document should be noted. This document was drafted in accordance with the editorial rules of the
ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed patent
rights in respect thereof. As of the date of publication of this document, ISO had not received notice of (a)
patent(s) which may be required to implement this document. However, implementers are cautioned that
this may not represent the latest information, which may be obtained from the patent database available at
www.iso.org/patents. ISO shall not be held responsible for identifying any or all such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and expressions
related to conformity assessment, as well as information about ISO's adherence to the World Trade
Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 8, Ships and marine technology, Subcommittee
SC 8, Ship design.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.
iv
Introduction
“B” class fire-resistant compartment systems made of composite mineral wool panels are widely used in
accommodation spaces in ships and offshore installations. Both ships and offshore installations have fire
and acoustic insulation capability as required by 1974 International Convention for the Safety of Life at Sea
(SOLAS 74) and its amendments.
This document is aligned with IMO documents, in particular SOLAS 74, IMO Resolution MSC.337 (91), IMO
MSC/Circ.917 and the International code for application of fire test procedures (FTP Code).
v
International Standard ISO 24682:2024(en)
Ships and marine technology — Technical requirements for
"B" class fire-resistant compartment systems of composite
mineral wool panel
1 Scope
This document provides requirements on fire resistance, acoustic insulation, opening and penetration for
“B” class fire-resistant compartment systems made of composite mineral wool panel, which are aligned with
the 2010 FTP Code and SOLAS 74 and its amendments. This document also specifies how these “B” class fire-
resistant compartment systems are inspected.
This document is applicable to accommodation spaces made by “B” class composite mineral wool panels for
ships and offshore installations where “B” class divisions are required.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
ISO 1716, Reaction to fire tests for products — Determination of the gross heat of combustion (calorific value)
ISO 10140-2, Acoustics — Laboratory measurement of sound insulation of building elements — Part 2:
Measurement of airborne sound insulation
ISO 22262-1, Air quality — Bulk materials — Part 1: Sampling and qualitative determination of asbestos in
commercial bulk materials
2010 FTP Code — International code for application of fire test procedures
SOLAS — International Convention for the Safety of Life at Sea
IMO Resolution MSC.337 (91) — Code on noise levels on board ships
IMO MSC/Circ.917 — Guidelines on Fire Safety Construction in Accommodation Areas – (4 June 1999)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at https:// www .electropedia .org/
3.1
“B” class
“B” class division
classification formed by bulkheads, decks, ceilings, or linings, including “B-15” and “B-0” class, constructed
of approved non-combustible materials (3.6)
[SOURCE: SOLAS, Chapter II-2, Reg. 3.4]
3.2
“B” class composite mineral wool panel
panel composed of a metal sheet, or sheets associated with mineral wool, and which meet “B-15” and “B-0”
class requirements
3.3
“B” class fire door
fixed door which has a fire resistance that is equivalent to “B” class division (3.1)
Note 1 to entry: See 2010 FTP Code, Annex 1, Part 3 for further details on the criteria with which a “B” class fire door
must comply.
3.4
window box
connection box between the “B” class composite mineral wool panel (3.2) and window or side scuttle
3.5
“B” class fire-resistant compartment system
compartment system consisting of a “B” class composite mineral wool panel (3.2), “B” class fire door (3.3),
window box (3.4), as well as any other openings and/or penetrations in the “B” class division (3.1)
3.6
non-combustible material
material which neither burns nor gives off flammable vapours in sufficient quantity for self-ignition when
heated to approximately 750 °C
3.7
combustible material
material other than non-combustible material (3.6)
3.8
low flame-spread characteristic
surface material of “B” class division (3.1) designed to adequately restrict the spread of flame
[SOURCE: SOLAS, Chapter II-2, Reg. 3.29]
3.9
“C” cla
...
Questions, Comments and Discussion