Laboratory glassware — One-mark volumetric flasks

Verrerie de laboratoire — Fioles jaugées à un trait

Laboratorijska steklovina - Volumetrijske steklenice z eno oznako

General Information

Status
Withdrawn
Publication Date
31-Jan-1983
Withdrawal Date
31-Jan-1983
Current Stage
9599 - Withdrawal of International Standard
Completion Date
02-Jul-1998

Relations

Buy Standard

Standard
ISO 1042:1983 - Verrerie de laboratoire -- Fioles jaugées a un trait
French language
3 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 1042:1995
French language
5 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

Norme internationale 1042
INTERNATIONAL ORGANIZATION FOR STANDARDIZATIONOMEmPYHAPOAHAR OPrAHH3AUHR il0 CTAHPl\~H3AUHH.ORGANlSATlON INTERNATIONALE DE NORMALISATION
Verrerie de laboratoire - Fioles jaugées à un trait
b
Laboratory glassware - Onemark volumetric flasks
Troisième édition - 1983-02-01
CDU 542.231.3.004.1 : 531.731.1 Réf. no : IS0 1W-1983 (FI
- 5
Descripteurs : verrerie de laboratoire, fiole jaugée, spécification, caractéristique géométrique, dimension, capacité, marquage.
$
O
E
Prix basé sur 3 pages

---------------------- Page: 1 ----------------------
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale
d'organismes nationaux de normalisation (comités membres de I'ISO). L'élaboration
I'ISO. Chaque
des Normes internationales est confiée aux comités techniques de
comité membre intéressé par une étude a le droit de faire partie du comité technique
correspondant. Les organisations internationales, gouvernementales et non gouverne-
mentales, en liaison avec I'ISO, participent également aux travaux.
Les projets de Normes internationales adoptés par les comités techniques sont soumis
aux comités membres pour approbation, avant leur acceptation comme Normes inter-
nationales par le Conseil de I'ISO.
La Norme internationale IS0 1042 a été élaborée par le comité technique ISO/TC 48,
Verrerie de laboratoire et appareils connexes.
Cette troisième édition a été soumise directement au Conseil de I'ISO, conformément
au paragraphe 6.1 1.2 de la partie 1 des Directives pour les travaux techniques de I'ISO.
Elle annule et remplace la deuxième édition (IS0 1042-1981 1, qui elle-même annulait et
remplacait 1'1S0 1042-1975 et incorporait le projet d'Amendement 1, qui avait été sou-
mis aux comités membres en décembre 1979 et qui avait été approuvé par les comités
membres des pays suivants :
Afrique du Sud, Rép. d' France Philippines
Allemagne, R. F. Hongrie Pologne
Australie Inde Roumanie
Brésil Italie Royaume-Uni
Corée, Rép. de Mexique Tchécoslovaquie
Espagne Pays-Bas
URSS
Aucun comité membre ne l'avait désapprouvé.
La première édition (IS0 1042-1975) avait été approuvée par les comités membres des
pays suivants :
Afrique du Sud, Rép. d'
Espagne Pologne
Australie France Pays-Bas
Autriche Grèce Royaume-Uni
Belgique Hongrie Suisse
Brésil Inde Tchécoslovaquie
Canada Irlande Turquie
Chili Israël
URSS
Colombie Italie USA
Yougoslavie
Corée, Rép. de Japon
Egypte, Rép. arabe d' Nouvelle-Zélande
Aucun comité membre ne l'avait désapprouvée.
0 Organisation internationale de normalisation, 1983 O
Imprimé en Suisse

---------------------- Page: 2 ----------------------
NORM E I NTERN ATlON ALE IS0 1042-1983 (F)
Verrerie de laboratoire - Fioles jaugées à un trait
5 Série des capacités
1 Objet et domaine d‘application
La série des capacités des fioles jaugées à un trait est la
La présente Norme internationale fixe les spécifications d’une
_-
série de fioles jaugées à un trait, acceptable sur le plan interna- suivante :
tional et satisfaisant aux besoins généraux des laboratoires.
-
5 - 10 - 25 - 50 - 100 - 200 - 2% - 500 - 1000et
Les spécifications sont conformes à I’ISO 384, Verrerie de labo- 2 O00 ml.
ratoire - Principes de conception et de construction de la ver-
rerie volumétrique. Toutes ces fioles peuvent se terminer par un col ordinaire ou
être pourvues d‘un bouchon.
NOTE - S’il est nécessaire de réaliser des fioles jaugées de capacités
2 Référence
autres que celles indiquées précédemment, il est recommandé de se
conformer, dans la mesure du possible, aux données essentielles de la
IS0 383, Verrerie de laboratoire - Assemblages coniques
présente Norme internationale.
rodés interchangeables.
3 Données fondamentales pour l’étalonnage
6 Définition de la capacité
3.1 Unité de volume
La capacité d‘une fiole jaugée est définie par le volume d’eau à
20 OC, exprimé en millilitres, contenu dans la fiole à 20 OC,
L‘unité de volume doit être le centimètre cube (cm3), appelé
quand elle est remplie jusqu’au trait repère.
aussi millilitre Iml).
- NOTE - Quand, exceptionnellement, la température de référence est
NOTE - Le terme millilitre (ml) est couramment utilisé comme nom
de 27 OC, cette valeur doit être substituée à 20 OC.
-- spécial donné au centimètre cube (cm3), conformément à la décision
de la Douzième Conférence Générale des Poids et Mesures. Le terme
La position du ménisque doit être déterminée par l’une des
millilitre est généralement admis pour désigner les capacités de la verre-
deux méthodes décrites ci-dessous :
rie volumétrique dans les Normes internationales et il est, en particulier,
utilisé dans le présent texte.
ai Le ménisque est ajusté de telle facon que le plan hori-
zontal passant par le bord supérieur du trait repère soit tan-
3.2 Température de référence
gent au ménisque en son point le plus bas, la ligne de visée
étant dans le même plan.
La température normale de référence, c’est-à-dire la tempéra-
ture à laquelle la fiole jaugée doit contenir son volume nominal
b) Le ménisque est ajusté de telle facon que le plan hori-
(capacité nominale), doit être de 20 OC.
zontal passant par le centre du trait repère soit tangent au
ménisque en son point le plus bas. L‘œil de l‘observateur se
NOTE - Quand la fiole doit être utilisée dans un pays ayant adopté
lève vers ce plan et observe les parties avant et arrière du
une température normale de référence de 27 OC, cette valeur doit être
trait, qui paraissent rencontrer simultanément le point le
substituée à 20 OC.
plus bas du ménisque.
4 Classes de précision
Deux classes de précision sont définies 7 Précision
Classe A pour la catégorie supérieure, La capacité de la fiole ne doit pas différer de la capacité nomi-
nale de plus des erreurs maximales tolérées indiquées dans le
Classe B pour la catégorie inférieure. tableau 1.
1

-----------
...

SLOVENSKI STANDARD
SIST ISO 1042:1995
01-avgust-1995
Laboratorijska steklovina - Volumetrijske steklenice z eno oznako
Laboratory glassware -- One-mark volumetric flasks
Verrerie de laboratoire -- Fioles jaugées à un trait
Ta slovenski standard je istoveten z: ISO 1042:1983
ICS:
17.060 Merjenje prostornine, mase, Measurement of volume,
gostote, viskoznosti mass, density, viscosity
71.040.20 Laboratorijska posoda in Laboratory ware and related
aparati apparatus
SIST ISO 1042:1995 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST ISO 1042:1995

---------------------- Page: 2 ----------------------

SIST ISO 1042:1995
Norme internationale 1042
INTERNATIONAL ORGANIZATION FOR STANDARDIZATIONOMEmPYHAPOAHAR OPrAHH3AUHR il0 CTAHPl\~H3AUHH.ORGANlSATlON INTERNATIONALE DE NORMALISATION
Verrerie de laboratoire - Fioles jaugées à un trait
b
Laboratory glassware - Onemark volumetric flasks
Troisième édition - 1983-02-01
CDU 542.231.3.004.1 : 531.731.1 Réf. no : IS0 1W-1983 (FI
- 5
Descripteurs : verrerie de laboratoire, fiole jaugée, spécification, caractéristique géométrique, dimension, capacité, marquage.
$
O
E
Prix basé sur 3 pages

---------------------- Page: 3 ----------------------

SIST ISO 1042:1995
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale
d'organismes nationaux de normalisation (comités membres de I'ISO). L'élaboration
I'ISO. Chaque
des Normes internationales est confiée aux comités techniques de
comité membre intéressé par une étude a le droit de faire partie du comité technique
correspondant. Les organisations internationales, gouvernementales et non gouverne-
mentales, en liaison avec I'ISO, participent également aux travaux.
Les projets de Normes internationales adoptés par les comités techniques sont soumis
aux comités membres pour approbation, avant leur acceptation comme Normes inter-
nationales par le Conseil de I'ISO.
La Norme internationale IS0 1042 a été élaborée par le comité technique ISO/TC 48,
Verrerie de laboratoire et appareils connexes.
Cette troisième édition a été soumise directement au Conseil de I'ISO, conformément
au paragraphe 6.1 1.2 de la partie 1 des Directives pour les travaux techniques de I'ISO.
Elle annule et remplace la deuxième édition (IS0 1042-1981 1, qui elle-même annulait et
remplacait 1'1S0 1042-1975 et incorporait le projet d'Amendement 1, qui avait été sou-
mis aux comités membres en décembre 1979 et qui avait été approuvé par les comités
membres des pays suivants :
Afrique du Sud, Rép. d' France Philippines
Allemagne, R. F. Hongrie Pologne
Australie Inde Roumanie
Brésil Italie Royaume-Uni
Corée, Rép. de Mexique Tchécoslovaquie
Espagne Pays-Bas
URSS
Aucun comité membre ne l'avait désapprouvé.
La première édition (IS0 1042-1975) avait été approuvée par les comités membres des
pays suivants :
Afrique du Sud, Rép. d'
Espagne Pologne
Australie France Pays-Bas
Autriche Grèce Royaume-Uni
Belgique Hongrie Suisse
Brésil Inde Tchécoslovaquie
Canada Irlande Turquie
Chili Israël
URSS
Colombie Italie USA
Yougoslavie
Corée, Rép. de Japon
Egypte, Rép. arabe d' Nouvelle-Zélande
Aucun comité membre ne l'avait désapprouvée.
0 Organisation internationale de normalisation, 1983 O
Imprimé en Suisse

---------------------- Page: 4 ----------------------

SIST ISO 1042:1995
NORM E I NTERN ATlON ALE IS0 1042-1983 (F)
Verrerie de laboratoire - Fioles jaugées à un trait
5 Série des capacités
1 Objet et domaine d‘application
La série des capacités des fioles jaugées à un trait est la
La présente Norme internationale fixe les spécifications d’une
_-
série de fioles jaugées à un trait, acceptable sur le plan interna- suivante :
tional et satisfaisant aux besoins généraux des laboratoires.
-
5 - 10 - 25 - 50 - 100 - 200 - 2% - 500 - 1000et
Les spécifications sont conformes à I’ISO 384, Verrerie de labo- 2 O00 ml.
ratoire - Principes de conception et de construction de la ver-
rerie volumétrique. Toutes ces fioles peuvent se terminer par un col ordinaire ou
être pourvues d‘un bouchon.
NOTE - S’il est nécessaire de réaliser des fioles jaugées de capacités
2 Référence
autres que celles indiquées précédemment, il est recommandé de se
conformer, dans la mesure du possible, aux données essentielles de la
IS0 383, Verrerie de laboratoire - Assemblages coniques
présente Norme internationale.
rodés interchangeables.
3 Données fondamentales pour l’étalonnage
6 Définition de la capacité
3.1 Unité de volume
La capacité d‘une fiole jaugée est définie par le volume d’eau à
20 OC, exprimé en millilitres, contenu dans la fiole à 20 OC,
L‘unité de volume doit être le centimètre cube (cm3), appelé
quand elle est remplie jusqu’au trait repère.
aussi millilitre Iml).
- NOTE - Quand, exceptionnellement, la température de référence est
NOTE - Le terme millilitre (ml) est couramment utilisé comme nom
de 27 OC, cette valeur doit être substituée à 20 OC.
-- spécial donné au centimètre cube (cm3), conformément à la décision
de la Douzième Conférence Générale des Poids et Mesures. Le terme
La position du ménisque doit être déterminée par l’une des
millilitre est généralement admis pour désigner les capacités de la verre-
deux méthodes décrites ci-dessous :
rie volumétrique dans les Normes internationales et il est, en particulier,
utilisé dans le présent texte.
ai Le ménisque est ajusté de telle facon que le plan hori-
zontal passant par le bord supérieur du trait repère soit tan-
3.2 Température de référence
gent au ménisque en son point le plus bas, la ligne de visée
étant dans le même plan.
La température normale de référence, c’est-à-dire la tempéra-
ture à laquelle la fiole jaugée doit contenir son volume nominal
b) Le ménisque est ajusté de telle facon que le plan hori-
(capacité nominale), doit être de 20 OC.
zontal passant par le centre du trait repère soit tangent au
ménisque en son point le plus bas. L‘œil de l‘observateur se
NOTE - Quand la fiole doit être utilisée dans un pays ayant adopté
lève vers ce plan et observe les parties avant et arrière du
une température normale de référence de 27 OC, cette valeur doit être
trait, qui
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.