Aerospace series - Connectors, electrical, circular, scoop-proof, triple start threaded coupling, operating temperature 175 °C or 200 °C continuous - Part 003: Receptacle square flange mounting - Product standard

This European Standard specifies the characteristics of square flange mounted receptacles in the family of
circular electrical connectors with triple start threaded coupling.
It applies to models in Table 3.
For contacts, sealing plugs and cable outlet accessories associated with this receptacle see EN 3645-002. For
plugs and protective covers, see EN 3645-008, EN 3645-011, EN 3645-012 and EN 3645-006 respectively.
These connectors are derived from and are interchangeable with those in standard MIL-DTL-38999/20.

Luft- und Raumfahrt - Elektrische Rundsteckverbinder, kontaktgeschützt, dreigängige Gewinde-Schnellkupplung, Betriebstemperatur 175 °C oder 200 °C konstant - Teil 003: Fester Steckverbinder mit quadratischem Montageflansch - Produktnorm

Série aérospatiale - Connecteurs électriques circulaires à contacts protégés, à accouplement par filetage à pas rapide à trois filets, températures d'utilisation 175 °C ou 200 °C continu - Partie 003: Embase à fixation par collerette carrée - Norme de produit

Aeronavtika - Konektorji, električni, okrogli, zaščiteni kontakt, hitra spojka z navojem, stalna delovna temperatura 175 °C ali 200 °C - 003. del: Spojnik s kvadratno montažno prirobnico - Standard za proizvod

Ta evropski standard določa značilnosti spojnikov s kvadratno montažno prirobnico iz družine okroglih električnih konektorjev s hitro spojko z navojem.
Uporablja se za modele iz preglednice 3.
Za kontakte, tesnilne čepe in priključke izhodov kablov, povezane s tem spojnikom, glej standard EN 3645-002. Za čepe in zaščitna prekrivala glej ustrezne standarde EN 3645-008, EN 3645-011, EN 3645-012 in EN 3645-006. Ti konektorji izhajajo iz konektorjev v standardu MIL-DTL-38999/20 in so medsebojno zamenljivi z njimi.

General Information

Status
Published
Publication Date
17-Mar-2015
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
06-Mar-2015
Due Date
11-May-2015
Completion Date
18-Mar-2015

Relations

Buy Standard

Standard
EN 3645-003:2015
English language
9 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 3645-003:2015
01-april-2015
1DGRPHãþD
SIST EN 3645-003:2009
$HURQDYWLND.RQHNWRUMLHOHNWULþQLRNURJOL]DãþLWHQLNRQWDNWKLWUDVSRMND]
QDYRMHPVWDOQDGHORYQDWHPSHUDWXUDƒ&DOLƒ&GHO6SRMQLNV
NYDGUDWQRPRQWDåQRSULUREQLFR6WDQGDUG]DSURL]YRG
Aerospace series - Connectors, electrical, circular, scoop-proof, triple start threaded
coupling, operating temperature 175 °C or 200 °C continuous - Part 003: Receptacle
square flange mounting - Product standard
Luft- und Raumfahrt - Elektrische Rundsteckverbinder, kontaktgeschützt, dreigängige
Gewinde-Schnellkupplung, Betriebstemperatur 175 °C oder 200 °C konstant - Teil 003:
Fester Steckverbinder mit quadratischem Montageflansch - Produktnorm
Série aérospatiale - Connecteurs électriques circulaires à contacts protégés, à
accouplement par filetage à pas rapide à trois filets, températures d'utilisation 175 °C ou
200 °C continu - Partie 003: Embase à fixation par collerette carrée - Norme de produit
Ta slovenski standard je istoveten z: EN 3645-003:2015
ICS:
49.060 /HWDOVNDLQYHVROMVND Aerospace electric
HOHNWULþQDRSUHPDLQVLVWHPL equipment and systems
SIST EN 3645-003:2015 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 3645-003:2015

---------------------- Page: 2 ----------------------

SIST EN 3645-003:2015

EUROPEAN STANDARD
EN 3645-003

NORME EUROPÉENNE

EUROPÄISCHE NORM
February 2015
ICS 49.060 Supersedes EN 3645-003:2006
English Version
Aerospace series - Connectors, electrical, circular, scoop-proof,
triple start threaded coupling, operating temperature 175 °C or
200 °C continuous - Part 003: Receptacle square flange
mounting - Product standard
Série aérospatiale - Connecteurs électriques circulaires à Luft- und Raumfahrt - Elektrische Rundsteckverbinder,
contacts protégés, à accouplement par filetage à pas rapide kontaktgeschützt, dreigängige Gewinde-Schnellkupplung,
à trois filets, températures d'utilisation 175 °C ou 200 °C Betriebstemperatur 175 °C oder 200 °C konstant - Teil 003:
continu - Partie 003: Embase à fixation par collerette carrée Fester Steckverbinder mit quadratischem Montageflansch -
- Norme de produit Produktnorm
This European Standard was approved by CEN on 5 December 2014.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 3645-003:2015 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN 3645-003:2015
EN 3645-003:2015 (E)
Contents Page
Foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 4
4 Required characteristics . 5
5 Designation . 8
6 Marking . 9
7 Technical specification . 9

2

---------------------- Page: 4 ----------------------

SIST EN 3645-003:2015
EN 3645-003:2015 (E)

Foreword
This document (EN 3645-003:2015) has been prepared by the Aerospace and Defence Industries
Association of Europe - Standardization (ASD-STAN).
After enquiries and votes carried out in accordance with the rules of this Association, this Standard has
received the approval of the National Associations and the Official Services of the member countries of ASD,
prior to its presentation to CEN.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by August 2015, and conflicting national standards shall be withdrawn
at the latest by August 2015.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN 3645-003:2006.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus,
Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United
Kingdom.
3

---------------------- Page: 5 ----------------------

SIST EN 3645-003:2015
EN 3645-003:2015 (E)
1 Scope
This European Standard specifies the characteristics of square flange mounted receptacles in the family of
circular electrical connectors with triple start threaded coupling.
It applies to models in Table 3.
For contacts, sealing plugs and cable outlet accessories associa
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.