Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-8: Classification of environmental conditions; Stationary use at underground locations

The purpose of this sub-part of this standard is to define the classes of environmental conditions and their severities to which equipment may be exposed at specified locations below ground level. The severities specified are those which will have a low probability of being exceeded; generally less than 1 %. This sub-part applies to equipment installed for stationary use at underground locations during:
- normal operation;
- on site installation and lining up;
- repair, maintenance and restoration of functions failed.

Inženiring opreme (EE) – Okoljski pogoji in preskusi vplivov okolja na telekomunikacijsko opremo – 1-8. del: : Klasifikacija okoljskih pogojev – Fiksna uporaba na podzemnih lokacijah

General Information

Status
Published
Publication Date
31-Jan-2006
Withdrawal Date
30-Sep-2003
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Feb-2006
Due Date
01-Feb-2006
Completion Date
01-Feb-2006

Buy Standard

Standard
ETS 300 019-1-8 E1:2006
English language
15 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST ETS 300 019-1-8 E1:2006
01-februar-2006
Inženiring opreme (EE) – Okoljski pogoji in preskusi vplivov okolja na
telekomunikacijsko opremo – 1-8. del: : Klasifikacija okoljskih pogojev – Fiksna
uporaba na podzemnih lokacijah
Equipment Engineering (EE); Environmental conditions and environmental tests for
telecommunications equipment; Part 1-8: Classification of environmental conditions;
Stationary use at underground locations
Ta slovenski standard je istoveten z: ETS 300 019-1-8 Edition 1
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
SIST ETS 300 019-1-8 E1:2006 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST ETS 300 019-1-8 E1:2006

---------------------- Page: 2 ----------------------

SIST ETS 300 019-1-8 E1:2006
EUROPEAN ETS 300 019-1-8
TELECOMMUNICATION September 1997
STANDARD
Source: EE Reference: DE/EE-01019-1-8
ICS: 33.020
Key words: Environment, testing, underground
Equipment Engineering (EE);
Environmental conditions and environmental tests for
telecommunications equipment;
Part 1-8: Classification of environmental conditions
Stationary use at underground locations
ETSI
European Telecommunications Standards Institute
ETSI Secretariat
Postal address: F-06921 Sophia Antipolis CEDEX - FRANCE
Office address: 650 Route des Lucioles - Sophia Antipolis - Valbonne - FRANCE
X.400: c=fr, a=atlas, p=etsi, s=secretariat - Internet: secretariat@etsi.fr
Tel.: +33 4 92 94 42 00 - Fax: +33 4 93 65 47 16
Copyright Notification: No part may be reproduced except as authorized by written permission. The copyright and the
foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 1997. All rights reserved.

---------------------- Page: 3 ----------------------

SIST ETS 300 019-1-8 E1:2006
Page 2
ETS 300 019-1-8: September 1997
Whilst every care has been taken in the preparation and publication of this document, errors in content,
typographical or otherwise, may occur. If you have comments concerning its accuracy, please write to
"ETSI Editing and Committee Support Dept." at the address shown on the title page.

---------------------- Page: 4 ----------------------

SIST ETS 300 019-1-8 E1:2006
Page 3
ETS 300 019-1-8: September 1997
Contents
Foreword .5
1 Scope .7
2 Normative references.7
3 Definitions and abbreviations .7
3.1 Definitions .7
3.2 Abbreviations .7
4 Environmental class .8
4.1 Class 8.1: Partly weatherprotected underground locations .8
5 Environmental conditions .10
5.1 Climatic conditions.10
5.2 Biological conditions .10
5.3 Chemically active substances.11
5.4 Mechanically active substances.11
5.5 Mechanical conditions.12
5.6 Earthquake conditions .12
History.15

---------------------- Page: 5 ----------------------

SIST ETS 300 019-1-8 E1:2006
Page 4
ETS 300 019-1-8: September 1997
Blank page

---------------------- Page: 6 ----------------------

SIST ETS 300 019-1-8 E1:2006
Page 5
ETS 300 019-1-8: September 1997
Foreword
This multi-part European Telecommunication Standard (ETS) has been produced by the Equipment
Engineering (EE) Technical Committee of the European Telecommunications Standards Institute (ETSI).
This ETS consists of 2 parts as follows:
Part 1: "Classification of environmental conditions";
Part 2: "Specification of environmental tests".
Part 1 specifies different standardized environmental classes covering climatic and biological conditions,
chemically and mechanically active substances and mechanical conditions during storage, transportation
and in use.
Part 2 specifies the recommended test requirements for the different environmental classes.
Each part of the standard is divided into sub-parts. Sub-part 1-0 forms a general overview of part 1. This
sub-part 1-8, deals with stationary use at underground locations and supersedes the application of
class 3.2 in ETS 300 019-1-3 for such locations.
Transposition dates
Date of adoption: 5 September 1997
Date of latest announcement of this ETS (doa): 31 December 1997
Date of latest publication of new National Standard
or endorsement of this ETS (dop/e): 30 June 1998
Date of withdrawal of any conflicting National Standard (dow): 30 June 1998

---------------------- Page: 7 ----------------------

SIST ETS 300 019-1-8 E1:2006
Page 6
ETS 300 019-1-8: September 1997
Blank page

---------------------- Page: 8 ----------------------

SIST ETS 300 019-1-8 E1:2006
Page 7
ETS 300 019-1-8: September 1997
1 Scope
The purpose of this sub-part of this standard is to define the classes of environmental conditions and their
severities to which equipment may be exposed at specified locations below ground level. The severities
specified are those which will have a low probability of being exceeded; generally less than 1 %.
This sub-part applies to equipment installed for stationary use at underground locations during:
- normal operation;
- on site installation and lining up;
- repair, maintenance and restoration of functions failed.
2 Normative references
This ETS incorporates by dated and undated reference, provisions from other publications. These
normative references are cited at the appropriate places in the text and the publications are listed
hereafter. For dated references, subsequent amendments to or revisions of any of these publications
apply to this ETS only when incorporated in it by amendment or revision. For undated references the latest
edition of the publication referred to applies.
[1] [reserved]
[2] [reserved]
[3] IEC Publication 721-3-3: "Stationary use at weatherprotected locations".
[4] IEC Publication 68-2-27: "Test Ea: Shock".
[5] IEC Publication 721-2-6: "Earthquake vibration and shock".
[6] IEC Publication 68-3-3: "Guidance. Seismic test methods for equipment".
3 Definitions and abbreviations
3.1 Definitions
For the purposes of this ETS, the following definitions apply:
stationary use: The equipment is permanently placed at a certain site. It is not intended for portable use
but short periods of handling during erection work, down time, maintenance and repair at the location are
accepted.
totally weatherprotected location: Direct weather influences are totally excluded.
partly weatherprotected location: Direct weather influences are not completely excluded.
3.2 Abbreviations
For the purposes of this ETS, the following abbreviations apply:
RS Response Spectrum
ZPA Zero Period Acceleration

---------------------- Page: 9 ----------------------

SIST ETS 300 019-1-8 E1:2006
Page 8
ETS 300 019-1-8: September 1997
4 Environmental class
4.1 Class 8.1: Partly weatherprotected underground locations
At present no underground classes in IEC 721 Publication series exist.
This class is a combination of classes 3Z7/3B2/3C2(3C3)/3S3/3M3(3M5) in IEC Publication 721-3-3 [3].
No IEC Publication 721-3-3 [3] climatic class is applicable.
Seismic environment: zone 4 as defined in IEC Publication 721-2-6 [5].
Option zone 4 (modified Mercalli scale ≥ 9): if earthquake conditions are specified by the customer, the
conditions stated in subclause 5.6 apply.
This class applies to partly weatherprotected underground locations. The location has no temperature or
humidity control, but the variations in the temperature are limited due to the stabilizing influence of the
surroundings.
The climatogram is shown in figure 1.
This class applies to locations:
- where the installed equipment is normally protected from direct weather influences;
- where the surrounding medium is normally air, but the equipment may be immersed in water during
exceptional conditions;
- where mould growth or attacks by animals, except termites, may occur;
- with nor
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.