Geosynthetic barriers - Test method for the determination of the influence of wetting-drying cycles on the permeability of clay geosynthetic barriers

This Technical Specification specifies an index test to determine the influence ratio of wetting-drying cycles on flux through saturated clay geosynthetic barriers.
This test is applicable to clay geosynthetic barrier products with a geotextile backing. It is not necessarily applicable to clay geosynthetic barrier products with a geomembrane backing.

Geosynthetische Dichtungsbahnen - Prüfverfahren zur Bestimmung des Einflusses von Nass-Trocken-Wechselbeanspruchungen auf die Durchlässigkeit von geosynthetischen Tondichtungsbahnen

Dieses Dokument legt ein Indexprüfverfahren zur Bestimmung des Einflussverhältnisses von Nass-Trocken-
Wechselbeanspruchungen auf den Durchfluss durch gesättigte geosynthetische Tondichtungsbahnen fest.
Diese Prüfung ist auf Produkte geosynthetischer Tondichtungsbahnen mit geotextiler Trägerschicht anwendbar.
Sie ist möglicherweise nicht anwendbar auf Produkte geosynthetischer Tondichtungsbahnen mit einer Geomem-
branträgerschicht.

Barrieres géosynthétiques - Méthode d'essai pour la détermination de l'influence de cycles secs-humides sur la perméabilité des barrieres géosynthétiques bentonitiques

Geosintetične ovire – Preskusna metoda za ugotavljanje vpliva ciklusov močenja-sušenja na prepustnost geosintetičnih bentonitnih ovir

General Information

Status
Withdrawn
Publication Date
28-Feb-2006
Withdrawal Date
21-Oct-2014
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
22-Oct-2014
Due Date
14-Nov-2014
Completion Date
22-Oct-2014

Relations

Buy Standard

Technical specification
TS CEN/TS 14417:2006
English language
11 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST-TS CEN/TS 14417:2006
01-marec-2006
*HRVLQWHWLþQHRYLUH±3UHVNXVQDPHWRGD]DXJRWDYOMDQMHYSOLYDFLNOXVRYPRþHQMD
VXãHQMDQDSUHSXVWQRVWJHRVLQWHWLþQLKEHQWRQLWQLKRYLU
Geosynthetic barriers - Test method for the determination of the influence of wetting-
drying cycles on the permeability of clay geosynthetic barriers
Geosynthetische Dichtungsbahnen - Prüfverfahren zur Bestimmung des Einflusses von
Nass-Trocken-Wechselbeanspruchungen auf die Durchlässigkeit von geosynthetischen
Tondichtungsbahnen
Barrieres géosynthétiques - Méthode d'essai pour la détermination de l'influence de
cycles secs-humides sur la perméabilité des barrieres géosynthétiques bentonitiques
Ta slovenski standard je istoveten z: CEN/TS 14417:2005
ICS:
59.080.70 Geotekstilije Geotextiles
SIST-TS CEN/TS 14417:2006 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST-TS CEN/TS 14417:2006

---------------------- Page: 2 ----------------------

SIST-TS CEN/TS 14417:2006
TECHNICAL SPECIFICATION
CEN/TS 14417
SPÉCIFICATION TECHNIQUE
TECHNISCHE SPEZIFIKATION
December 2005
ICS 59.080.70

English Version
Geosynthetic barriers - Test method for the determination of the
influence of wetting-drying cycles on the permeability of clay
geosynthetic barriers
Barrières géosynthétiques - Méthode d'essai pour la Geosynthetische Dichtungsbahnen - Prüfverfahren zur
détermination de l'influence de cycles secs-humides sur la Bestimmung des Einflusses von Nass-Trocken-
perméabilité des barrières géosynthétiques bentonitiques Wechselbeanspruchungen auf die Durchlässigkeit von
geosynthetischen Tondichtungsbahnen
This Technical Specification (CEN/TS) was approved by CEN on 3 April 2005 for provisional application.
The period of validity of this CEN/TS is limited initially to three years. After two years the members of CEN will be requested to submit their
comments, particularly on the question whether the CEN/TS can be converted into a European Standard.
CEN members are required to announce the existence of this CEN/TS in the same way as for an EN and to make the CEN/TS available
promptly at national level in an appropriate form. It is permissible to keep conflicting national standards in force (in parallel to the CEN/TS)
until the final decision about the possible conversion of the CEN/TS into an EN is reached.
CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,
Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2005 CEN All rights of exploitation in any form and by any means reserved Ref. No. CEN/TS 14417:2005: E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST-TS CEN/TS 14417:2006
CEN/TS 14417:2005 (E)
Contents Page
Foreword .3
Introduction.4
1 Scope .5
2 Normative references .5
3 Terms and definitions.5
4 Principle.5
5 Reagent.5
6 Apparatus .6
7 Procedure .8
8 Calculation and expression of results.10
9 Test report .10
Bibliography.11

2

---------------------- Page: 4 ----------------------

SIST-TS CEN/TS 14417:2006
CEN/TS 14417:2005 (E)
Foreword
This Technical Specification (CEN/TS 14417:2005) has been prepared by Technical Committee CEN/TC 189
“Geosynthetics”, the secretariat of which is held by IBN/BIN.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to announce this CEN Technical Specification: Austria, Belgium, Cyprus, Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland
and United Kingdom.

3

---------------------- Page: 5 ----------------------

SIST-TS CEN/TS 14417:2006
CEN/TS 14417:2005 (E)
Introduction
This Technical Specification defines a method for testing the influence ratio of wetting-drying cycles on the
permeability of clay geosynthetic barriers. Such resistance is a requirement for many uses of these products.
The influence ratio is an indication of the behaviour of the product when exposed to repeated wetting and
drying cycles in earth constructions. The permeability of saturated clay geosynthetic barriers may increase
after exposure to repeated wetting-drying cycles.
This Technical Specification does not purport to address all of the safety problems, if any, associated with its
use. It is the responsibility of the user of this document to establish appropriate safety and health practices
and to comply with any regulations or legislation regardless of the wording in the document.
The current Technical Specification has not yet been widely validated. The organisation of interlaboratory-
tests to acquire more experience is recommended.
4

---------------------- Page: 6 ----------------------

SIST-TS CEN/TS 14417:2006
CEN/TS 14417:2005 (E)
1 Scope
This Technical Specification specifies an index test to determine the influence ratio of wetting-drying cycles on
flux through saturated clay geosynthetic barriers.
This test is applicable to clay geosynthetic barrier products with a geotextile backing. It is not necessarily
applicable to clay geosynthetic barrier products with a geomembrane backing.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
EN ISO 10320, Geotextiles and geotextile-related products – Identification on site (ISO 10320:1999)
EN ISO 3696, Water for analytical laboratory use – Specification and test methods (ISO 3696:1987)
3 Terms and definitions
For the purposes of this Technical Specification, the following term and definition applies.
3.1
influence ratio
ratio of the flux value of a specimen exposed to wetting-drying cycles and divided by the flux through an
unexposed reference specimen, expressed in percent
4 Principle
The flux through 100 mm diameter clay geosynthetic barrier specimens is determined with a flexible wall
permeameter both on specimens exposed to wetting-drying cycles and on unexposed reference specimens.
Samples of 300 mm x 300 mm are saturated under a pressure of (4 ± 0,2) kPa for 48 h at constant room
temperature. After saturation, one sample is dried in an oven at 110 °C for 24 h, while the reference sample
remains at normal room temperature. After the drying period the first sample is allowed to cool to room
temperature for 24 h. Then the samples are submerged again for 24 h at room temperature. This wetting-
drying cycle is performed four times before cutting the test specimens.
The specimen is mounted in a flexible-wall permeameter, subjected to a total pressure of 550 kPa and a back
pressure of 515 kPa for a period of 48 h. Flow is initiated using de-ionized water by raising the pressure on the
inlet side of the test specimen to 530 kPa. The flux is determined when inflow and outflow are approximately
equal (within ± 25 %).
NOTE This test does not provide a hydraulic conductivity value. Hydraulic conductivity can be determined in a similar
way, but requires knowledge of the thickness of the specimen. This test does not include procedures for thickness
measurement of the clay geosynthetic barrier or of its clay component.
5 Reagent
De-aired, de-ionized water shall be in accordance with EN ISO 3696, grade 3.
5

---------------------- Page: 7 ----------------------

SIST-TS CEN/TS 14417:2006
CEN/TS 14417:2005 (E)
Water is used to permeate the test specimen and also to exert a back pressure on the test specimen. As the
flux can be substantially influenced by the nature of the test liquid, de-aired, de-ionized water shall be used in
this test method.
The water shall be de-aired as well as de-ionized. The water is usually de-aired by boiling, by spraying a fine
mist of water in a vessel connected to a vacuum source, or by forceful agitation of water in a container
connected to a vacuum source. The de-aired water shall not be exposed to air for prolonged periods to
prevent the dissolving of air back into water.
6 Apparatus
NOTE The apparatus used in this test method is commonly used to determine the hydraulic conductivity of soil
specimens. However, flux values measured in this test are typically much lower than those commonly measured for
natural soils. The leakage rate of the apparatus should be less than 10 % of the flux.
6.1 Hydraulic system
This system shall be designed to facilitate rapid and complete removal of free air bubbles from flow lines and
be capable of maintaining constant hydraulic pressures within ± 5 %. It may be one of the following types:
 method A: a constant head system, e.g. the system specified in ASTM D 5887:2003; provided that it
meets the criteria specified in this method;
 method B: a falling head method;
 method C: a constant rate of flow.
Pressures shall be measured by any device of suitable accuracy, e.g. a pressure gage or an electronic
pressure transducer.
The hydraulic system shall be capable to apply and to maintain a back pressure within ± 5 % on the specimen,
to facilitate saturation throughout the duration of the measurements.
The backpressure may be provided by a compressed gas supply, a dead-weight acting on a piston, or by any
other suitable means.
6.2 Flow measurement system
For the determination of flow volume within an accuracy of ± 5 % a system shall be used with a graduated
accumulator, a graduated pipette, a vertical standpipe in conjunction with an electronic pressure transducer or
any other suitable device.
Both inflow and outflow volumes shall be measured unless the absence of leakage, the continuity of the flow
and the cessation of consolidation or swelling can be verified by other means.
6.3 Permeameter cell
An apparatus shall be used in which the specimen and porous end pieces, enclos
...