SIST EN 14064-1:2010
(Main)Thermal insulation products for buildings - In-situ formed loosefill mineral wool (MW) products - Part 1: Specification for the loose-fill products before installation
Thermal insulation products for buildings - In-situ formed loosefill mineral wool (MW) products - Part 1: Specification for the loose-fill products before installation
This European Standard specifies the requirements for blown loose-fill mineral wool products for in-situ installation in lofts, masonry cavity walls and frame constructions. This European standard is a specification for the insulation products before installation. It describes the product characteristics and includes procedures for testing, marking and labelling. This document does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards. This document does not cover factory made mineral wool (MW) insulation products or in-situ products intended to be used for the insulation of building equipment and industrial installations. Products with a declared thermal resistance lower than 0,25 m2ˇK/W or a declared thermal conductivity greater than 0,060 W/(mˇK) at 10 °C are not covered by this document. This document does not cover products intended for airborne sound insulation and for acoustic absorption applications.
Wärmedämmstoffe für Gebäude - An der Verwendungsstelle hergestellte Wärmedämmung aus Mineralwolle (MW) - Teil 1: Spezifikation für Schüttdämmstoffe vor dem Einbau
Diese Europäische Norm legt die Anforderungen an an der Verwendungsstelle einzubringende lose Einblas-dämm¬stoffe aus Mineralwolle zur Dämmung von Dachgeschossen sowie zur Kerndämmung in zweischaligem Mauerwerk und Rahmenkonstruktionen fest.
Diese Europäische Norm ist eine Spezifikation für die Dämmstoffe vor dem Einbau. Er beschreibt die Produktmerkmale und enthält Verfahren für die Prüfung, Kennzeichnung und Etikettierung.
Dieses Dokument legt keine Anforderungsstufen für eine bestimmte Eigenschaft fest, die ein Produkt erreichen muss, um für einen bestimmten Anwendungsfall gebrauchstauglich zu sein. Derartige Anforde-rungsstufen für einen bestimmten Anwendungsfall sind Regelwerken oder nicht entgegenstehenden Normen zu entnehmen.
ANMERKUNG Zur Vermeidung des Eindringens von Wasser ins Mauerwerk können gegebenenfalls spezielle Prü¬fungen in Anpassung an die örtlichen klimatischen Bedingungen erforderlich sein.
Dieses Dokument deckt keine werkmäßig hergestellten Dämmstoffe aus Mineralwolle (MW) oder an der Verwendungsstelle hergestellten Produkte ab, die für die Dämmung von Gebäudeaus¬rüstungsgegenständen und betriebstechnischen Anlagen vorgesehen sind.
Produkte mit einem Nennwert des Wärmedurchlasswiderstands unter 0,25 m2K/W oder einem Nennwert der Wärmeleitfähigkeit von mehr als 0,060 W/(m K) bei 10 °C werden von diesem Dokument nicht abgedeckt.
Dieses Dokument gilt nicht für Produkte für die Anwendung zur Luftschalldämmung und Schallabsorption.
Produits isolants thermiques pour le bâtiment - Isolation thermique formée sur chantier à base de laine minérale (MW) - Partie 1 : Spécification des produits en vrac avant l'installation
La présente Norme européenne spécifie les exigences concernant les produits de laine minérale en vrac destinés à être installés par soufflage dans les combles, les murs en maçonnerie à double paroi et les constructions à ossature.
Cette Norme européenne est une spécification pour les produits isolants avant installation. Elle décrit les caractéristiques du produit et comprend des modes opératoires d'essai, de marquage et d'étiquetage.
Ce document ne spécifie pas le niveau requis d'une propriété donnée devant être atteint par un produit pour en démontrer l'aptitude à la fonction dans une application particulière. Les niveaux requis pour une application particulière sont à trouver dans les réglementations ou dans des normes non contradictoires.
NOTE Pour éviter l’infiltration de l’eau dans les murs en maçonnerie, des essais spécifiques adaptés au climat local peuvent être nécessaires.
Ce document ne couvre pas les produits isolants en laine minérale (MW) manufacturés ou les produits en place conçus pour être utilisés pour l'isolation de l'équipement et des installations industrielles.
Les produits dont la résistance thermique déclarée est inférieure à 0,25 m2•K/W dont la conductivité thermique déclarée à 10 °C dépasse 0,060 W/(m•K) ne sont pas couverts par ce document.
Ce document ne couvre pas les produits ayant pour fonction l'isolement aux bruits aériens et l'absorption acoustique.
Toplotnoizolacijski proizvodi za stavbe - Razsuti proizvodi iz mineralne volne (MW) - 1. del: Specifikacija za vezane in razsute proizvode pred vgradnjo
Ta evropski standard določa zahteve za vpihane razsute proizvode iz mineralne volne za in situ vgradnjo na podstrešjih, votlih zidovih in ogrodnih konstrukcijah. Ta evropski standard predstavlja specifikacijo za izolacijske proizvode pred vgradnjo. Opisuje značilnosti proizvodov in vključuje postopke preskušanja, označevanja in uporabe nalepk. Ta standard ne določa zahtevane ravni določene lastnosti, ki jo mora doseči proizvod, da ustreza zahtevam za uporabnosti pri določenem načinu uporabe. Zahtevane ravni za določen način uporabe so navedene v predpisih ali nenasprotujočih si standardih. Ta dokument ne zajema tovarniško izdelanih izolacijskih proizvodov iz mineralne volne (MW) ali in situ proizvodov, ki so namenjeni za izolacijo opreme stavb in industrijskih inštalacij. Ta dokument ne zajema proizvodov z nazivno toplotno prevodnostjo pod 0,25 25 m2ˇK/W ali nazivno toplotno prevodnostjo nad 0,060 W/(mˇK) pri 10 °C. Ta dokument ne zajema proizvodov, namenjenih za izolacijo zvoka, ki se prenaša po zraku, in za akustično absorpcijo.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Toplotnoizolacijski proizvodi za stavbe - Razsuti proizvodi iz mineralne volne (MW) - 1. del: Specifikacija za vezane in razsute proizvode pred vgradnjoWärmedämmstoffe für Gebäude - An der Verwendungsstelle hergestellte Wärmedämmung aus Mineralwolle (MW) - Teil 1: Spezifikation für Schüttdämmstoffe vor dem EinbauProduits isolants thermiques pour le bâtiment - Isolation thermique formée sur chantier à base de laine minérale (MW) - Partie 1 : Spécification des produits en vrac avant l'installationThermal insulation products for buildings - In-situ formed loosefill mineral wool (MW) products - Part 1: Specification for the loose-fill products before installation91.100.60Thermal and sound insulating materialsICS:Ta slovenski standard je istoveten z:EN 14064-1:2010SIST EN 14064-1:2010en,fr,de01-maj-2010SIST EN 14064-1:2010SLOVENSKI
STANDARD
SIST EN 14064-1:2010
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 14064-1
February 2010 ICS 91.100.60 English Version
Thermal insulation products for buildings - In-situ formed loose-fill mineral wool (MW) products - Part 1: Specification for the loose-fill products before installation
Produits isolants thermiques pour le bâtiment - Isolation thermique formée sur chantier à base de laine minérale (MW) - Partie 1 : Spécification des produits en vrac avant l'installation
Wärmedämmstoffe für Gebäude - An der Verwendungsstelle hergestellte Wärmedämmung aus Mineralwolle (MW) - Teil 1: Spezifikation für Schüttdämmstoffe vor dem Einbau This European Standard was approved by CEN on 9 January 2010.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2010 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14064-1:2010: ESIST EN 14064-1:2010
EN 14064-1:2010 (E) 2 Contents Page Foreword .51Scope .72Normative references .73Terms, definitions, symbols and abbreviations .83.1Terms and definitions .83.2Symbols and abbreviations .84Requirements .94.1General .94.2For all applications . 104.2.1Thermal conductivity − Thermal resistance. 104.2.2Weight of the sale unit . 104.2.3Settlement . 104.2.4Reaction to fire . 124.2.5Durability characteristics . 124.3For specific applications . 134.3.1General . 134.3.2Airflow resistivity . 134.3.3Water absorption . 134.3.4Water vapour diffusion resistance . 134.3.5Reaction to fire of product in standardized assemblies simulating end-use applications. 134.3.6Release of dangerous substances . 134.3.7Continuous glowing combustion . 145Test methods . 145.1Sampling . 145.2Conditioning . 145.3Testing . 145.3.1General . 145.3.2Thermal resistance and thermal conductivity . 155.3.3Reaction to fire . 166Designation code . 167Evaluation of conformity . 167.1General . 167.2Initial type testing . 177.3Factory production control . 178Marking and labelling . 17Annex A (normative)
Determination of the declared values of thermal resistance and thermal conductivity . 20A.1Introduction . 20A.2Input data . 20A.3Declared values. 20A.3.1General . 20A.3.2Case where thermal resistance and thermal conductivity are declared . 21A.3.3Case where only thermal resistance is declared . 22Annex B (normative)
Factory production control . 23Annex C (normative)
Specimen preparation method for thermal resistance and thermal conductivity test . 25SIST EN 14064-1:2010
EN 14064-1:2010 (E) 3 C.1Principle. 25C.2Procedure . 25C.2.1Specimen preparation method for ventilated roof spaces application. . 25C.2.2Specimen preparation method for closed cavities application. . 26Annex D (normative)
Specimen preparation method for water absorption test . 27D.1Principle. 27D.2Procedure . 27Annex E (normative)
Specimen preparation method for airflow resistivity test . 28E.1Principle. 28E.2Procedure . 28Annex F (normative)
Testing for reaction to fire of products . 29F.1Scope . 29F.2Product and installation
parameters . 29F.3Standardized Mounting and fixing . 30F.3.1Test specimens for EN ISO 11925-2 (Ignitability) and EN 13823 (SBI) . 30F.3.2EN ISO 11925-2 (Ignitability) . 30F.3.3EN 13823 (SBI) . 30Annex G (normative)
Testing for reaction to fire of products in standardised assemblies simulating end-use application(s) . 31G.1Scope . 31G.2Product and installation parameters . 31G.3Standardized Mounting and fixing . 32G.3.1Test specimens for EN ISO 11925-2 (Ignitability) and EN 13823 (SBI) . 32G.3.2EN ISO 11925-2 (Ignitability) . 32G.3.3EN 13823 (SBI) . 32Annex H (normative)
Rules for creating performance charts for loose-fill insulation and examples of performance charts . 33H.1General . 33H.2Performance chart for loft insulation . 33H.3Performance chart for masonry cavity wall insulation and frame constructions insulation . 34Annex I (normative)
Verification of performance chart according to Annex H (normative) . 36I.1Principle. 36I.2Procedure . 36Annex J (normative)
Specimen preparation method for coverage and density measurement . 37J.1Principle. 37J.2Procedure for ventilated roof space application . 37J.3Procedure for closed construction . 38Annex K (normative)
Thermal insulating products for lofts - Determination of settlement for blown loose fill insulation. 39K.1Principle. 39K.2Apparatus . 39K.3Test specimens . 39K.4Test procedure . 39K.5Calculations and expression of results . 40K.6Test report . 40Annex L (informative)
Masonry cavity walls - Method for determining suitable spacings for blowing holes . 42L.1Test house . 42L.2Test method . 42L.3Observations . 42L.4Installation procedure . 42Annex ZA (informative)
Clauses of this European Standard addressing the provisions of the EU Construction Products Directive . 45ZA.1Scope and relevant characteristics . 45SIST EN 14064-1:2010
EN 14064-1:2010 (E) 4 ZA.2Procedures for attestation of conformity of in-situ formed loose-fill mineral wool (MW) products . 46ZA.2.1Systems of attestation of conformity . 46ZA.2.2EC certificate and declaration of conformity . 49ZA.3CE Marking and labelling . 51Bibliography . 54 SIST EN 14064-1:2010
EN 14064-1:2010 (E) 5 Foreword This document (EN 14064-1:2010) has been prepared by Technical Committee CEN/TC 88 “Thermal insulating materials and products”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2010, and conflicting national standards shall be withdrawn at the latest by November 2011. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. EN 14064, Thermal insulation products for buildings — In-situ formed loose-fill mineral wool (MW) products, consists of two parts which form a package. The first part (this European Standard), which is the harmonised part satisfying the mandate, the CPD and is the basis for the CE marking, covers the products, which are placed on the market. The second part, which is the non-harmonised part, covers the specification for the installed products. Both parts need to be used for the application of the insulation product in the end-use applications covered by EN 14064. This European Standard contains thirteen annexes: Annex A (normative) Determination of the declared values of thermal resistance and thermal conductivity Annex B (normative) Factory production control Annex C (normative) Specimen preparation for thermal resistance and thermal conductivity test Annex D (normative) Specimen preparation for water absorption test Annex E (normative) Specimen preparation for airflow resistivity test Annex F (normative) Testing for reaction to fire of products Annex G (normative) Testing for reaction to fire of products in standardised assemblies simulating end-use applications
Annex H (normative) Rules for creating performance charts for loose-fill insulation and examples of performance charts Annex I (normative) Verification of performance chart according to Annex H (normative) Annex J (normative) Specimen preparation method for coverage measurement
Annex K (normative) Thermal insulating products for lofts − Determination of settlement for blown loose fill insulation Annex L (informative) Masonry cavity walls − Method for determining suitable spacing for blowing holes SIST EN 14064-1:2010
EN 14064-1:2010 (E) 6 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Directive This European Standard is one of a series for mineral wool, expanded clay, expanded perlite, exfoliated vermiculite, polyurethane/polyisocyanurate, cellulose and bound expanded polystyrene in-situ formed insulation products used in buildings, but this standard may be used in other areas where appropriate. The reduction in energy used and emissions produced during the installed life of insulation products exceeds by far the energy used and emissions made during the production and disposal processes. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
SIST EN 14064-1:2010
EN 14064-1:2010 (E) 7 1 Scope This European Standard specifies the requirements for blown loose-fill mineral wool products for in-situ installation in lofts, masonry cavity walls and frame constructions. This European standard is a specification for the insulation products before installation. It describes the product characteristics and includes procedures for testing, marking and labelling. This document does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards. NOTE To avoid water penetration in masonry walls special tests adjusted to local climate might be needed. This document does not cover factory made mineral wool (MW) insulation products or in-situ products intended to be used for the insulation of building equipment and industrial installations. Products with a declared thermal resistance lower than 0,25 m2·K/W or a declared thermal conductivity greater than 0,060 W/(m·K) at 10 °C are not covered by this document. This document does not cover products intended for airborne sound insulation and for acoustic absorption applications. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 823, Thermal insulating products for building applications — Determination of thickness EN 1609:1996, Thermal insulating products for building applications — Determination of short term water absorption by partial immersion EN 12667, Thermal performance of building materials and products — Determination of thermal resistance by means of guarded hot plate and heat flow meter methods — Products of high and medium thermal resistance EN 13172:2008, Thermal insulation products — Evaluation of conformity EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification using data from reaction to fire tests EN 13820, Thermal insulating materials for building applications — Determination of organic content EN 13823, Reaction to fire tests for building products — Building products excluding floorings exposed to the thermal attack by a single burning item EN 15715:2009, Thermal insulation products — Instructions for mounting and fixing for reaction to fire testing — Factory made products EN 29053:1993, Acoustics — Materials for acoustical applications — Determination of air flow resistance
(ISO 9053:1991) EN ISO 1182, Reaction to fire tests for building products — Non-combustibility test (ISO 1182:2002) SIST EN 14064-1:2010
EN 14064-1:2010 (E) 8 EN ISO 1716, Reaction to fire tests for building products — Determination of the heat of combustion (ISO 1716:2002) EN ISO 11925-2, Reaction to fire tests — Ignitability of building products subjected to direct impingement of flame — Part 2: Single-flame source test (ISO 11925-2:2002) 3 Terms, definitions, symbols and abbreviations 3.1 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1.1 mineral wool insulation material having a woolly consistency, manufactured from molten rock, slag or glass 3.1.2 blowing hole hole, cut or formed, in a masonry cavity wall or frame construction, through which the mineral wool is blown 3.1.3 class combination of two levels of the same property between which the performance shall fall 3.1.4 coverage mass of insulation per unit area 3.1.5 frame construction walls with wood or metal studs, sloping roof with insulation between rafters 3.1.6 level given value, which is the upper or lower limit of a requirement, where the level is given by the declared value of the characteristic concerned 3.1.7 performance chart table giving thickness and coverage requirements for different values of declared thermal resistance 3.1.8 settlement decrease of installed insulation thickness in lofts or height in cavities and frame constructions with time, expressed as a percentage of the initial installed thickness or installed height 3.2 Symbols and abbreviations Symbols used in this document: λ90/90 is the 90 % fractile with a confidence level of 90 % for the thermal conductivity W/(m·K) λD is the declared thermal conductivity W/(m·K) λi is one test result of thermal conductivity W/(m·K) λmean is the mean thermal conductivity W/(m·K) SIST EN 14064-1:2010
EN 14064-1:2010 (E) 9 λ(ρ)
is the curve of thermal conductivity versus density a, b, c are constants used in the formula λ(ρ) = a + bρ + c/ρ
ρ90/90 is the 90 % fractile with a confidence level of 90 % for the density
kg/m3 ρI is one test result of density kg/m3
ρmean is the mean value of density
kg/m3 ρD is the declared density
kg/m3 A is the area of the test specimen
m² d is the thickness of the test specimen mm n is the number of test results – R90/90 is the 90 % fractile with a confidence level of 90 % for the thermal resistance m2·K/W RD is the declared thermal resistance m2·K/W Ri is one test result of thermal resistance m2·K/W sλ is the estimate of the standard deviation of the thermal conductivity W/(m·K) sR is the estimate of the standard deviation of the thermal resistance W/(m·K) sρ is the estimate of the standard deviation of the density kg/m3 Wp is the short-term water absorption kg/m2 Bnom is the nominal weight of the bag kg AF is the symbol of the declared level of airflow resistivity MU is the symbol for the declared value for water vapour diffusion resistance factor S is the symbol of the declared class for settlement WS is the symbol of the declared level for short-term water absorption Abbreviations used in this document: MW Mineral Wool ITT Initial Type Test 4 Requirements 4.1 General Product properties shall be assessed in accordance with Clause 5. To comply with this standard, products shall meet the requirements of 4.2, and the requirements of 4.3 as appropriate. This document gives performance charts for three different applications: loft insulation; masonry cavity wall insulation; frame insulation. SIST EN 14064-1:2010
EN 14064-1:2010 (E) 10 One test result on a product property is the average of the measured values on the number of test specimens given in Table 3. 4.2 For all applications 4.2.1 Thermal conductivity − Thermal resistance Thermal resistance and thermal conductivity shall be based upon measurements carried out in accordance with EN 12667. The thermal values shall be determined in accordance with Annex A and declared by the manufacturer, according to the following: the reference mean temperature shall be 10 °C; the measured values shall be expressed with three significant figures; if the calculation of the declared thermal conductivity value is based on the curve (), this curve shall be determined by the mean of the equation: a + bρ + c/ρ , where a, b and c are constants determined by a non-linear regression analysis; the thermal resistance, RD, shall always be declared. The thermal conductivity, λD, shall be declared where possible; the thermal resistance, RD, and the thermal conductivity, λD, shall be given as limit values representing at least 90 % of the production determined with a confidence level of 90 %; the value of thermal conductivity λ90/90 shall be rounded upwards to the nearest 0,001 W/(m·K) and declared in levels with steps of 0,001 W/(m·K); the declared thermal resistance, RD, shall be calculated from the insulation thickness and the corresponding thermal conductivity, λ90/90 (see Note below); The value of thermal resistance, RD, shall be rounded downward to the nearest 0,05 m2·K/W and declared in levels with steps of 0,05 m2·K/W. NOTE The declaration of the installed thermal resistance for blown mineral wool is described in EN 14064-2. 4.2.2 Weight of the sale unit The
...
Questions, Comments and Discussion