Thermal insulation products for buildings - Factory made wood wool (WW) products - Specification

This European Standard specifies the requirements for factory made products of wood wool, with or without facings, which are used for the thermal insulation of buildings.
This European Standard also specifies the requirements for the factory made composite products, made from wood wool in combination with other insulation materials. The products are manufactured in the form of boards or slabs.
This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
Products covered by this European Standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This European Standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels/classes required for a given application are to be found in regulations or non conflicting standards.
Products with a declared thermal resistance lower than 0,15 m2K/W or a declared thermal conductivity greater than 0,1 W/(mK) at 10 °C are not covered by this European Standard.
This European Standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations.
This European Standard does not cover the following acoustical aspects: direct airborne sound insulation and impact noise transmission.

Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Holzwolle (WW) - Spezifikation

Diese Europäische Norm legt die Anforderungen für werkmäßig hergestellte Produkte aus Holzwolle mit oder
ohne Kaschierung fest, die für die Wärmedämmung von Gebäuden benutzt werden.
Diese Europäische Norm beschreibt die Stoffeigenschaften und enthält die Prüfverfahren und Festlegungen
für die Konformitätsbewertung, die Kennzeichnung und die Etikettierung.
Diese Europäische Norm beschreibt auch die Anforderungen für werkseitig erzeugte Mehrschicht-Produkte,
gefertigt aus Holzwolle in Verbindung mit einem anderen Dämmmaterial. Die Produkte werden in Form von
Platten produziert.
In dieser Europäischen Norm beschriebene Produkte werden auch in vorgefertigten Wärmedämmsystemen
und Mehrschicht-Verbundplatten angewendet; die Eigenschaften von Systemen, in die diese Produkte
integriert sind, werden nicht behandelt.
Diese Europäische Norm legt keine Anforderungsniveaus für eine vorgegebene Eigenschaft fest, die ein
Produkt erreichen muss, um für einen bestimmten Anwendungsfall tauglich zu sein. Für bestimmte
Anwendungen benötigte Anforderungen können Regelwerken oder übereinstimmenden Normen entnommen
werden.
Diese Europäische Norm gilt nicht für Produkte, deren Nennwert des Wärmedurchlasswiderstandes niedriger
ist als 0,15 m2 ⋅ K/W oder deren Nennwert der Wärmeleitfähigkeit größer ist als 0,1 W/(m ⋅ K) bei 10 °C
Mitteltemperatur.
Diese Europäische Norm gilt nicht für in-situ-Dämmstoffe und für Produkte, die zur Dämmung von
haustechnischen und betriebstechnischen Anlagen bestimmt sind (oder Produkte, die zur Schalldämmung
bestimmt sind).
Diese Europäische Norm gilt nicht für die folgenden Schallschutzaspekte: direkte Luftschalldämmung und
Trittschallübertragung.

Produits isolants thermiques pour le bâtiment - Produits manufacturés en laine de bois (WW) - Spécification

La présente Norme européenne spécifie les exigences auxquelles doivent satisfaire les produits manufacturés en laine de bois, avec ou sans parements, utilisés pour l’isolation thermique des bâtiments. Les produits sont fabriqués sous forme de panneaux ou de plaques.
La présente norme décrit les caractéristiques de ces produits et comporte des modes opératoires d’essai, d’évaluation de conformité, de marquage et d’étiquetage.
La présente Norme européenne spécifie les exigences auxquelles doivent satisfaire les produits composites manufacturés à base de laine de bois en combinaison avec d’autres matériaux isolants.
Les produits couverts par la présente Norme européenne sont également utilisés dans les systèmes d’isolation thermique préfabriqués et les panneaux composites ; les performances des systèmes incorporant ces produits ne sont pas traitées.
La présente Norme ne spécifie pas de niveau à atteindre par le produit pour une propriété donnée, pour démontrer son aptitude à l’usage dans une application particulière. Les niveaux/classes requis pour une application donnée figurent dans les réglementations ou dans les normes non conflictuelles.
Les produits dont la résistance thermique déclarée à une température de 10 °C est inférieure à 0,15 m2K/W ou dont la conductivité thermique déclarée à une température de 10 °C est supérieure à 0,1 W/(mK) ne sont pas du domaine d’application de la présente Norme européenne.
Les produits mis en œuvre in situ et ceux destinés à être utilisés pour l’isolation des équipements du bâtiment et des installations industrielles ne sont pas du domaine d’application de la présente Norme européenne.
La présente norme ne couvre pas les critères acoustiques suivants : isolement aux bruits aériens directs et transmission des bruits de choc.

Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz lesne volne (WW) - Specifikacija

General Information

Status
Withdrawn
Public Enquiry End Date
30-Jul-2008
Publication Date
13-Jan-2009
Withdrawal Date
15-Jan-2013
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
14-Dec-2012
Due Date
06-Jan-2013
Completion Date
16-Jan-2013

Relations

Buy Standard

Standard
EN 13168:2009
English language
40 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz lesne volne (WW) - SpecifikacijaWärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Holzwolle (WW) - SpezifikationProduits isolants thermiques pour le bâtiment - Produits manufacturés en laine de bois (WW) - SpécificationThermal insulation products for buildings - Factory made wood wool (WW) products - Specification91.100.60Thermal and sound insulating materialsICS:Ta slovenski standard je istoveten z:EN 13168:2008SIST EN 13168:2009en,fr,de01-februar-2009SIST EN 13168:2009SLOVENSKI
STANDARDSIST EN 13168:2002/AC:2006SIST EN 13168:2002/A1:2004SIST EN 13168:20021DGRPHãþD



SIST EN 13168:2009



EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13168November 2008ICS 91.100.60Supersedes EN 13168:2001
English VersionThermal insulation products for buildings - Factory made woodwool (WW) products - SpecificationProduits isolants thermiques pour le bâtiment - Produitsmanufacturés en laine de bois (WW) - SpécificationWärmedämmstoffe für Gebäude - Werkmäßig hergestellteProdukte aus Holzwolle (WW) - SpezifikationThis European Standard was approved by CEN on 18 October 2008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2008 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13168:2008: ESIST EN 13168:2009



EN 13168:2008 (E) 2 Contents Page Foreword .4 1 Scope .6 2 Normative references .6 3 Terms, definitions, symbols, units and abbreviated terms .7 4 Requirements . 10 5 Test methods . 16 6 Designation code . 19 7 Evaluation of conformity . 20 8 Marking and labelling . 20 Annex A (normative)
Determination of the declared values of thermal conductivity and
thermal resistance . 21 Annex B (normative)
Factory production control . 23 Annex C (normative)
Specific test methods . 27 Annex D (normative)
Specific items concerning this standard . 30 Annex ZA (informative)
Clauses of this European Standard addressing the provisions of the EU Construction Products Directive. 33
Tables Table 1 — Classes for length and width tolerances . 12 Table 2 — Classes for thickness tolerances . 12 Table 3 — Levels for the deviation from squareness . 12 Table 4 — Levels for deviation from flatness . 13 Table 5 — Levels for compressive stress or compressive strength . 13 Table 6 — Levels for chloride content . 14 Table 7 — Levels for tensile strength perpendicular to faces . 14 Table 8 — Test methods, test specimens and conditions. 18 Table A.1 — Values for k for one sided 90 % tolerance interval with a confidence level of 90 % . 22 Table B.1 — Minimum product testing frequencies . 23 Table B.2 — Minimum product testing frequencies for the reaction to fire characteristics . 25 Table D.1 — Levels for bending strength . 31 Table ZA.1 — Relevant clauses for Wood wool and intended use . 34 Table ZA.2 — Systems of attestation of conformity . 35 Table ZA.3 — Assignment of evaluation of conformity tasks for products under system 1 . 36 Table ZA.4 — Assignment of evaluation of conformity tasks for products under system 3 or system 3 combined with system 4 for reaction to fire . 37 SIST EN 13168:2009



EN 13168:2008 (E) 3
Figures Figure C.1 — Test rig for load resistance of slabs . 28 Figure C.2 — Test rig for impact resistance of slabs . 29 Figure ZA.1 — Example CE marking information . 40
SIST EN 13168:2009



EN 13168:2008 (E) 4 Foreword This document (EN 13168:2008) has been prepared by Technical Committee CEN/TC 88 “Thermal insulating materials and products”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2009, and conflicting national standards shall be withdrawn at the latest by May 2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EC Directive(s). For relationship with EC Directive(s), see informative Annex ZA, which is an integral part of this document. This document supersedes EN 13168:2001. This document is one of a series of standards for insulation products used in buildings, but this standard may be used in other areas where appropriate. In pursuance of Resolution BT 20/1993 revised, CEN/TC 88 have proposed defining the standards listed below as a package of documents. The package of standards comprises the following group of interrelated standards for the specifications of factory made thermal insulation products, all of which come within the scope of CEN/TC 88: EN 13162, Thermal insulation products for buildings — Factory made mineral wool (MW) products — Specification EN 13163, Thermal insulation products for buildings — Factory made products of expanded polystyrene (EPS) — Specification EN 13164, Thermal insulation products for buildings — Factory made products of extruded polystyrene foam (XPS) — Specification EN 13165, Thermal insulation products for buildings — Factory made rigid polyurethane foam (PUR) products — Specification EN 13166, Thermal insulation products for buildings — Factory made products of phenolic foam (PF) — Specification EN 13167, Thermal insulation products for buildings — Factory made cellular glass (CG) products — Specification EN 13168, Thermal insulation products for buildings — Factory made wood wool (WW) products — Specification EN 13169, Thermal insulation products for buildings — Factory made products of expanded perlite (EPB) — Specification EN 13170, Thermal insulation products for buildings — Factory made products of expanded cork (ICB) — Specification SIST EN 13168:2009



EN 13168:2008 (E) 5 EN 13171, Thermal insulation products for buildings — Factory made wood fibre (WF) products — Specification According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
SIST EN 13168:2009



EN 13168:2008 (E) 6 1 Scope This European Standard specifies the requirements for factory made products of wood wool, with or without facings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or slabs. This European Standard specifies product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. This European Standard also specifies the requirements for the factory made composite products, made from wood wool in combination with other insulation materials. Products covered by this European Standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered. This European Standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels/classes required for a given application are to be found in regulations or non-conflicting standards. Products with a declared thermal resistance lower than 0,15 m2⋅K/W or a declared thermal conductivity greater than 0,1 W/(m⋅K) at 10 °C are not covered by this European Standard. This European Standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations. This European Standard does not cover the following acoustical aspects: direct airborne sound insulation and impact noise transmission. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
EN 822, Thermal insulating products for building applications — Determination of length and width EN 823, Thermal insulating products for building applications — Determination of thickness EN 824, Thermal insulating products for building applications — Determination of squareness EN 825, Thermal insulating products for building applications — Determination of flatness EN 826, Thermal insulating products for building applications — Determination of compression behaviour EN 1602, Thermal insulating products for building applications — Determination of the apparent density EN 1604, Thermal insulation products for building applications — Determination of dimensional stability under specified temperature and humidity conditions EN 1605, Thermal insulating products for building applications — Determination of deformation under specified load and temperature conditions EN 1606, Thermal insulating products for building applications — Determination of compressive creep EN 1607, Thermal insulating products for building applications — Determination of tensile strength perpendicular to faces SIST EN 13168:2009



EN 13168:2008 (E) 7 EN 1609, Thermal insulating products for building applications — Determination of short term water absorption by partial immersion EN 12086:1997, Thermal insulating products for building applications — Determination of water vapour transmission properties EN 12089, Thermal insulating products for building applications — Determination of bending behaviour EN 12430, Thermal insulating products for building application — Determination of behaviour under point load EN 12667, Thermal performance for building materials and products — Determination of thermal resistance by means of guarded hot plate and heat flow meter methods — Products of high and medium thermal resistance EN 12939, Thermal performance for building materials and products — Determination of thermal resistance by means of guarded hot plate and heat flow meter methods — Thick products of high and medium thermal resistance EN 13172:2008, Thermal insulating products — Evaluation of conformity EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification using data from reaction to fire test EN 13820, Thermal insulating materials for building applications — Determination of organic content EN 13823, Reaction to fire tests for building products — Building products excluding floorings exposed to the thermal attack by a single burning item EN ISO 354, Acoustics — Measurement of sound absorption in a reverberation room (ISO 354:2003) EN ISO 1182, Reaction to fire tests for building products — Non-combustibility test (ISO 1182:2002) EN ISO 1716, Reaction to fire tests for building products — Determination of he heat of combustion (ISO 1716:2002)
EN ISO 9229:2007, Thermal insulation — Vocabulary (ISO 9229:2007)
EN ISO 11654, Acoustics — Sound absorbers for use in buildings — Rating of sound absorption (ISO 11654:1997) EN ISO 11925-2, Reaction to fire tests — Ignitability of building products subjected to direct impingement of flame – Part 2: Single-flame source test (ISO 11925-2:2002) ISO 12491, Statistical methods for quality control of building materials and components 3 Terms, definitions, symbols, units and abbreviated terms 3.1 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1.1 Terms and definitions as given in EN ISO 9229:2007 3.1.1.1 wood wool long shavings of wood SIST EN 13168:2009



EN 13168:2008 (E) 8 3.1.1.2 board slab rigid or semi-rigid (insulation) product of rectangular shape and cross section in which the thickness is uniform and substantially smaller than the other dimensions NOTE Boards are usually thinner than slabs. They may also be supplied in tapered form. 3.1.2 Additional terms and definitions 3.1.2.1 level given value which is the upper or lower limit of a requirement
NOTE The level is given by the declared value of the characteristic concerned. 3.1.2.2 class combination of two levels of the same property between which the performance shall fall 3.1.2.3 inorganic cementing agent binder used for producing wood wool products are portland cement, magnesite and a combination of cement and lime 3.1.2.4 wood wool board wood wool slab rigid insulation product manufactured from loose wood wool, bonded with a mineral binder and compressed to its final thickness 3.1.2.5 composite wood wool slab composite insulation product in which wood wool is bonded with a mineral binder, on one or both face(s) to other insulating materials
EXAMPLE mineral wool, foamed rigid cellular plastics.
NOTE 1 The final thickness of the “two layer” or “three layer” products, produced in this way, is determined during manufacture.
NOTE 2 The wood wool layer(s) of composite wood wool slabs cover the bonded insulation layer completely. 3.2 Symbols, units and abbreviated terms 3.2.1 Symbols and units used in this standard: αp is the practical sound absorption coefficient – αw is the weighted sound absorption coefficient – b is the width mm D is the thickness mm dN is the nominal thickness of the product mm ∆εb is the relative change in width % SIST EN 13168:2009



EN 13168:2008 (E) 9 ∆εd is the relative change in thickness % ∆εl is the relative change in length % Fp is the point load at a given deformation N k is a factor related to the number of test results – l is the length mm λ90/90 is the 90 % fractile with a confidence level of 90 % for the thermal conductivity W/(m⋅K) λD is the declared thermal conductivity W/(m⋅K) λi is one test result of thermal conductivity W/(m⋅K) λmean is the mean thermal conductivity W/(m⋅K) µ is the water vapour diffusion resistance factor – n is the number of test results – R90/90 is the 90 % fractile with a confidence level of 90 % for the thermal resistance m2⋅K/W RD is the declared thermal resistance m2⋅K/W Ri is one test result of thermal resistance m2⋅K/W Rmean is the mean thermal resistance m2⋅K/W ρa is the apparent density kg/m3 Sb is the deviation from squareness on length and width mm/m Smax is the deviation from flatness mm sR is the estimate of the standard deviation of the thermal resistance m2⋅K/W sλ is the estimate of the standard deviation of the thermal conductivity W/(m⋅K) σ10 is the compressive stress at 10% deformation kPa σb is the bending strength kPa σc is the declared compressive stress kPa σm is the compressive strength kPa σmt is the tensile strength perpendicular to faces kPa Wp is the short term water absorption kg/m2 Xct is the compressive creep mm Xt is the deformation at time t (total thickness reduction) mm Z is the water vapour resistance m2⋅h⋅Pa/mg APi is the symbol of the declared level of practical sound absorption coefficient* AWi Is the symbol of the declared level of weighted sound absorption coefficient* BS(+) is the symbol of the declared level for bending strength for a specified span CC(i mm,y) σc is the symbol of the declared level for compressive creep* SIST EN 13168:2009



EN 13168:2008 (E) 10 Cl is the symbol of the declared level for cloride content CS(10\Y)i
is the symbol of the declared level for compressive stress or strength* DS(L) is the symbol of the declared value for dimensional stability under specified load andtemperature conditions DS(TH) is the symbol of the declared dimensional stability at specified temperature and relativehumidity conditions L is the symbol of the declared class for length tolerances MUi is the symbol of the declared value for water vapour diffusion resistance factor* P Is the symbol of the declared value for flatness tolerances PL(2)i is the symbol of the declared level of point load for 2 mm deformation* S is the symbol of the declared class for squareness tolerances Ti is the symbol of the declared class for thickness tolerances* Tri is the symbol of the declared level for tensile strength perpendicular to faces* W is the symbol of the declared class for width tolerances WS is the symbol of the declared level for short term water absorption Zi is the symbol of the declared value for water vapour resistance* * "i” is the relevant class or level, "1c” is the compressive stress, and "y” is the number of years 3.2.2 Abbreviated terms used in this standard: WW iWood Wool board, slab WW-C Composite Wood Wool board, slab WW-C/3 xx 3-layered Composite Wood Wool board, slab in combination with xx. NOTE xx stands for the suitable insulation material used. ITT Initial Type Test RTF Reaction To Fire FPC Factory Production Control 4 Requirements 4.1 General Product properties shall be assessed in accordance with Clause 5. To comply with this standard, products shall meet the requirements of 4.2, and the requirements of 4.3 as appropriate. NOTE Information on additional properties is given in Annex D.
One test result for a product property is the average of the measured values on the number of test specimens given in Table 8. SIST EN 13168:2009



EN 13168:2008 (E) 11 All thermal insulating products used for the manufacture of WW-C-slabs shall comply with the relevant European Product Standards. 4.2 For all applications 4.2.1 Thermal resistance and thermal conductivity Thermal resistance and thermal conductivity shall be based upon measurements carried out in accordance with EN 12667 or EN 12939 for thick products. The thermal resistance and thermal conductivity shall be determined in accordance with Annex A and declared by the manufacturer according to the following:  the reference mean temperature shall be 10 °C;  the measured values shall be expressed with three significant figures;  for products of uniform thickness, the thermal resistance, RD, shall always be declared. The thermal conductivity, λD, shall be declared where possible. Where appropriate, for products of non-uniform thickness (e.g. for sloped and tapered products) only the thermal conductivity, λD, shall be declared.  the declared thermal resistance, RD, and thermal conductivity, λD, shall be given as limit values representing at least 90 % of the production, determined with a confidence level of 90 %;  the value of thermal conductivity λ90/90, shall be rounded upwards to the nearest 0,001 W/(m⋅K) and declared as λD in levels with steps of 0,001 W/(m⋅K);  the declared thermal resistance, RD, shall be calculated from the nominal thickness dN, and the corresponding thermal conductivity λ90/90.  the value of the thermal resistance, R90/90, when calculated from the nominal thickness, dN, and the corresponding declared thermal conductivity, λ90/90, shall be rounded downwards to the nearest 0,05 m2⋅K/W, and declared as RD in levels with steps of 0,05 m2⋅K/W;  the value of R90/90, for those products for which only the thermal resistance is measured directly, shall be rounded downwards to the nearest 0,05 m2⋅K/W and declared as RD in levels with steps of 0,05 m2⋅K/W. 4.2.2 Length and width Length, l, and width, b, shall be determined in accordance with EN 822. No test result shall deviate from the nominal length and width by more than the tolerances given in Table 1 for the declared class. SIST EN 13168:2009



EN 13168:2008 (E) 12
Table 1 — Classes for length and width tolerances Class Tolerances mm L1 +5, –10 L2 +3, –5 L3 ± 1a; ± 2b W1 ± 3 W2 ± 1 a For nominal length ≤ 1 250 mm. b For nominal length > 1 250 mm.
4.2.3 Thickness Thickness, d, shall be determined in accordance with EN 823. No test result shall deviate from the nominal thickness, dN, by more than the tolerances given in Table 2 for the declared class. Table 2 — Classes for thickness tolerances Class Tolerances mm Nominal thickness mm T1 +3, –2 ≤ 100 T2 ± 1 T3 +4, –3 > 100 T4 ± 2
4.2.4 Squareness Squareness, Sb, shall be determined in accordance with EN 824. The deviation from squareness shall not exceed the requirements given in Table 3 for the declared level. Table 3 — Levels for the deviation from squareness Level Requirement mm/m S1 ≤ 6 S2 ≤ 4 S3 ≤ 2
SIST EN 13168:2009



EN 13168:2008 (E) 13 4.2.5 Flatness The property is only relevant for faced products. Flatness, Smax, shall be determined in accordance with EN 825. The deviation from flatness shall not exceed the requirements given in Table 4 for the declared level. Table 4 — Levels for deviation from flatness Level Requirement mm P1 ≤ 6 P2 ≤ 3
4.2.6 Compressive stress or compressive strength Compression stress at 10 % deformation, σ10, or the compressive strength, σm, shall be determined in accordance with EN 826. No test result for either the compressive stress or the compressive strength, which ever is the smaller, shall be less than the value, given in Table 5 for the declared level. Table 5 — Levels for compressive stress or compressive strength Level Requirement kPa CS(10/Y)20 ≥ 20 CS(10/Y)30 ≥ 30 CS(10/Y)50 ≥ 50 CS(10/Y)75 ≥ 75 CS(10/Y)100 ≥ 100 CS(10/Y)150 ≥ 150 CS(10/Y)200 ≥ 200 CS(10/Y)300 ≥ 300 CS(10/Y)500 ≥ 500 CS(10/Y)750 ≥ 750 CS(10/Y)1000 ≥ 1000
For handling purposes, all products shall have as a minimum level CS(10/Y)20 4.2.7 Apparent density and mass per unit area The apparent density of wood wool slabs, a, shall be determined in accordance with EN 1602. No test result shall differ from the declared value by more than ± 10 %. The mass per unit area of composite wood wool slabs shall be determined from measurements of mass and shall be determined in accordance with EN 1602. No test result shall differ from the declared value by more than ± 10 %. SIST EN 13168:2009



EN 13168:2008 (E) 14 4.2.8 Compatibility with other materials (chloride content) The compatibility of wood wool slabs and the wood wool layers of composite wood wool slabs with other building materials is assessed through measurements of chloride content, determined in accordance with C.1. No test result shall exceed the values given in Table 6 for the declared level. Table 6 — Levels for chloride content Level Requirement % Cl1 ≤ 0,35 Cl2 ≤ 0,15 Cl3 ≤ 0,06
4.2.9 Dimensional stability under specified temperature and humidity conditions Dimensional stability under specified temperature and humidity conditions of wood wool slabs shall be determined in accordance with EN 1604. The test shall be carried out after storage for 48 h at (70 ± 2) °C and (90 ± 5) % relative humidity. The relative change in thickness, ∆εd, shall not exceed 3,0 %. The relative changes in length, ∆εl, and width, ∆εb, shall not exceed 0,5 %. 4.2.10 Tensile strength perpendicular to faces Tensile strength perpendicular to faces, σmt, shall be determined in accordance with EN 1607. No test result shall be lower than the value given in Table 7 for the declared level. Table 7 — Levels for tensile strength perpendicular to faces Level Requirement kPa TR5
≥ 5,0 TR7,5
≥ 7,5 TR10
≥ 10 TR15
≥ 15 TR20
≥ 20 TR40
≥ 40 TR70
≥ 70 TR100
≥ 100
For handling purposes, all WW-C products shall have as a minimum level TR5. The tensile strength perpendicular to faces of wood wool slabs shall not be tested. 4.2.11 Reaction to fire Reaction to fire classification (Euroclasses) shall be determined in accordance with EN 13501-1. SIST EN 13168:2009



EN 13168:2008 (E) 15 4.2.12 Durability characteristics 4.2.12.1 General The appropriate durability characteristics have been considered and are covered in 4.2.12.2, 4.2.12.3 and 4.2.12.4. 4.2.12.2 Durability of reaction to fire against ageing/ degradation The reaction to fire performance of factory made products of wood wool does not change with time. 4.2.12.3 Durability of thermal resistance and thermal conductivity against ageing/ degradation The thermal conductivity of factory made products of wood wool does not change with time. This is covered by 4.2.1 thermal conductivity, 4.2.2 Length and width and 4.2.9 dimensional stability or 4.3.2 dimensional stability. 4.2.12.4 Durability of compressive strength against ageing/degradation The durability of compressive strength is covered by 4.3.7 Compressive creep. 4.3 For specific applications 4.3.1 General If there is no requirement for a property described in 4.3 for a product in use, then the property does not need to be determined and declared by the manufacturer. 4.3.2 Dimensional stability under specific load and temperature conditions Dimensional stability under specific load and temperature conditions shall be determined in accordance with EN 1605. The test shall be carried out for (48 ± 1) h at (23 ± 5) °C under loads of 20 kPa, 40 kPa and 80 kPa. The relative change in thickness, ∆εd, shall not exceed 2 %. 4.3.3 Point load Point load at 2 mm deformation shall be determined in accordance with EN 12430 and declared in levels with steps of 50 N. No test result shall be less than the declared level. 4.3.4 Bending strength The bending strength, σb, shall be determined in accordance with EN 12089. The calculation of bending strength shall take account the requirements of D.1. No test result shall be less than the declared level. 4.3.5 Water vapour transmission Water vapour transmission properties of wood wool products including facings and coatings shall be determined in accordance with EN 12086 and declared as the water vapour diffusion resistance factor, µ, for homogeneous products and as the water vapour resistance, Z, for faced or non-homogeneous products. No test result of µ shall be greater than the declared value and no test result of Z shall be less than the declared value. In the absence of measurements, the water vapour diffusion resistance factor, µ, of wood wool products, either unfaced or faced with
...