(Main)Conductors of insulated cables - First supplement: Guide to the dimensional limits of circular conductors
Conductors of insulated cables - First supplement: Guide to the dimensional limits of circular conductors
Specifies standardized nominal cross-section areas from 0.5 mm2 to 2 000 mm2, numbers and diameters of wires and resistance values of conductors in electric cables and flexible cords. Classifies conductors for: 1.Cables for fixed installations -Class 1, solid conductors; -Class 2, stranded conductors. 2.Flexible copper conductors -Class 5, -Class 6 (more flexible than Class 5). Includes table of temperature correction factors kt for conductor resistance to correct the measured resistance at t °C to 20°C. Does not apply to conductors for telecommunication purposes. Applies to conductors of special design only when stated in the specification for the type of cable. Conductors of special design are, for example. conductors for pressure cables, conductors in extra-flexible welding cables or in special types of flexible cables for having the cores twisted together with unusually short lays. Note: In this edition, the number of classes of conductors has been reduced from 6 to 4.
Leiter für Kabel und isolierte Leitungen - Richtlinie für die dimensionsmäßigen Grenzen von Rundleitern
Ames des câbles isolés - Premier complément: Guide pour les limites dimensionelles des âmes circulaires
Spécifie la section nominale normalisée, de 0,5 mm2 à 2 000 mm2, ainsi que le nombre et le diamètre des brins et les valeurs de résistance des âmes des conducteurs et câbles électriques isolés. Classifie les âmes pour: 1. Câbles pour installations fixes: - classe 1, âmes massives; - classe 2, âmes câblées. 2. Âmes souples en cuivre: - classe 5; - classe 6 (plus souples que classe 5). Inclut un tableau de facteurs de correction de température kt, à appliquer à la mesure de résistance de l'âme effectuée à t °C pour la ramener à 20 °C. Ne s'applique pas aux conducteurs de télécommunication, et ne s'applique aux âmes spéciales que lorsque cela est indiqué dans la spécification particulière. Les âmes spéciales sont par exemple les âmes de câbles à pression, les âmes de câbles de soudage extra-souples ou celles de certains types de câbles souples dont les conducteurs sont assemblés avec des pas exceptionnellement courts. Note: Dans cette édition, le nombre des classes de câbles a été réduit de 6 à 4.
Conductors of insulated cables - Guide to the dimensional limits of circular conductors (IEC 228:1978 + IEC 228A:1982 (Modified))
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST HD 383 S2:1998
01-februar-1998
Conductors of insulated cables - Guide to the dimensional limits of circular
conductors (IEC 228:1978 + IEC 228A:1982 (Modified))
Conductors of insulated cables - First supplement: Guide to the dimensional limits of
circular conductors
Leiter für Kabel und isolierte Leitungen - Richtlinie für die dimensionsmäßigen Grenzen
von Rundleitern
Ames des câbles isolés - Premier complément: Guide pour les limites dimensionelles
des âmes circulaires
Ta slovenski standard je istoveten z: HD 383 S2:1986
ICS:
29.060.20 Kabli Cables
SIST HD 383 S2:1998 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST HD 383 S2:1998
---------------------- Page: 2 ----------------------
SIST HD 383 S2:1998
---------------------- Page: 3 ----------------------
SIST HD 383 S2:1998
---------------------- Page: 4 ----------------------
SIST HD 383 S2:1998
---------------------- Page: 5 ----------------------
SIST HD 383 S2:1998
---------------------- Page: 6 ----------------------
SIST HD 383 S2:1998
---------------------- Page: 7 ----------------------
SIST HD 383 S2:199
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.