Thermal insulation products for buildings - In-situ formed loose fill cellulose (LFCI) products - Part 2: Specification for the installed products

This European Standard specifies requirements for in-situ formed loose-fill cellulose insulation (LFCI) products when installed as thermal insulation into walls, floors, galleries, roofs, lofts and ceilings. This Part 2 is a specification for the installation checks for the installed products.It specifies the checks and tests to be used for the declarations made by the installer of the product. This European Standard does not specify the required level of all properties to be achieved by a product to demonstrate fitness for purpose in a particular application. The required levels are to be found in regulations or non-conflicting standards. Products with a declared thermal conductivity at 10 °C (mean temperature) greater than 0,060 W/(m × K) or a declared thermal resistance lower than 0,25 m2 × K/W are not covered by this European Standard. This European Standard does not cover factory made cellulose mats, bats or quilts intended to be used for the insulation of buildings or in-situ cellulose products for the insulation of building equipment and industrial installations. Nor does it specify performance requirements.

Wärmedämmstoffe für Gebäude - An der Verwendungsstelle hergestellter Wärmedämmstoff aus Zellulosefüllstoff (LFCI) - Teil 2: Spezifikation für die eingebauten Produkte

Diese Europäische Norm legt Anforderungen für an der Verwendungsstelle hergestellte Produkte aus Zellulosedämmstoff (LFCI) fest, die als Wärmedämmung in Wände, Fußböden, Galerien, Dächer, Dachgeschosse und Decken eingebaut werden.
Der vorliegende Teil 2 ist eine Spezifikation für die Überprüfung der eingebauten Produkte.
Hierin werden auch die Kontrollen und Prüfungen festgelegt, die für die Erklärungen durch den Verarbeiter der Produkte anzuwenden sind.
Diese Europäische Norm legt keine erforderlichen Leistungsstufen für alle Eigenschaften fest, die ein Produkt für den Nachweis der Gebrauchstauglichkeit in einer bestimmten Anwendung erreichen muss. Die erforder-lichen Stufen können Regelwerken oder nicht entgegenstehenden Normen entnommen werden.
Produkte mit einem Nennwert der Wärmeleitfähigkeit bei 10 °C (mittlerer Temperatur) von mehr als 0,060 W/(m  K) oder einem Nennwert des Wärmedurchlasswiderstands von weniger als 0,25 m2  K/W sind nicht Gegenstand dieser Europäischen Norm.
Diese Europäische Norm gilt weder für werkseitig hergestellte Zelluloseprodukte für die Wärmedämmung von Gebäuden, die in Form von Matten oder Platten in Verkehr gebracht werden, noch für an der Verwendungsstelle hergestellte Zellulosedämmprodukte für die Wärmedämmung von haus  und betriebstechnischen Anlagen. Sie legt auch keine Leistungsanforderungen fest.

Produits isolants thermiques destinés aux applications du bâtiment - Isolation thermique formée en place à base de cellulose (LFCI) - Partie 2: Spécifications des produits mis en oeuvre

La présente Norme européenne spécifie les exigences pour les produits d'isolation formés en place à base de cellulose (LFCI) lorsqu'ils sont mis en œuvre en tant qu'isolants thermiques dans les murs, les sols, les galeries, les toits, les combles et les plafonds.
La présente partie 2 constitue une spécification des vérifications d'installation pour les produits mis en œuvre.
Elle spécifie également les contrôles et les méthodes d'essai à utiliser pour les déclarations faites par l'installateur du produit.
La présente Norme européenne ne spécifie pas le niveau requis de toutes les propriétés nécessaires pour qu'un produit démontre son aptitude à l'emploi dans une application particulière. Les niveaux requis figurent dans les réglementations ou normes non contradictoires.
Les produits ayant une conductivité thermique à 10 °C (température moyenne) supérieure à 0,060 W/(m  K) ou une résistance thermique déclarée inférieure à 0,25 m2  K/W ne sont pas couverts par la présente Norme européenne.
La présente Norme européenne ne couvre pas les nappes, rouleaux ou panneaux fabriqués en usine destinés à l'isolation des bâtiments ou les produits à base de cellulose formés en place pour l'isolation de l'équipement du bâtiment et les installations industrielles. Elle ne spécifie pas non plus d'exigences de performance.

Toplotnoizolacijski proizvodi za stavbe - Razsuti celulozni proizvodi (LFCI) za oblikovanje na mestu vgradnje - 2. del: Specifikacija za vgrajene proizvode

Ta evropski standard določa zahteve za razsute celulozne izolacijske proizvode (LFCI) za oblikovanje na mestu vgradnje, ko se uporabljajo za toplotno izolacijo sten, tal, galerij, streh, podstrešij in stropov. Ta 2. del je specifikacija za preglede namestitve nameščenih proizvodov. Določa preglede in preskuse, na podlagi katerih monter izdelka poda izjave. Ta evropski standard ne določa zahtevane ravni vseh lastnosti, ki jo mora proizvod doseči, da se dokaže njegova primernost za namen v posamezni vrsti uporabe. Zahtevane ravni so določene v uredbah ali standardih, ki niso v nasprotju s tem standardom. Proizvodi z deklarirano toplotno prevodnostjo pri 10 °C (povprečna temperatura), višjo od 0,060 W/(m×K), ali deklarirano toplotno upornostjo, nižjo od 0,25 m2×K/W, niso zajeti v tem evropskem standardu. Ta evropski standard ne zajema tovarniških celuloznih podlog, kopren ali polnil za izolacijo stavb, ali razsutih celuloznih proizvodov za oblikovanje na mesto vgradnje za izolacijo opreme stavb in industrijskih naprav. Prav tako ne določa zahtev glede lastnosti.

General Information

Status
Published
Public Enquiry End Date
29-Apr-2013
Publication Date
08-Oct-2013
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
03-Oct-2013
Due Date
08-Dec-2013
Completion Date
09-Oct-2013

Buy Standard

Standard
EN 15101-2:2013
English language
22 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
k FprEN 15101-2:2013
English language
21 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Toplotnoizolacijski proizvodi za stavbe - Razsuti celulozni proizvodi (LFCI) za oblikovanje na mestu vgradnje - 2. del: Specifikacija za vgrajene proizvodeWärmedämmstoffe für Gebäude - An der Verwendungsstelle hergestellter Wärmedämmstoff aus Zellulosefüllstoff (LFCI) - Teil 2: Spezifikation für die eingebauten ProdukteProduits isolants thermiques destinés aux applications du bâtiment - Isolation thermique formée en place à base de cellulose (LFCI) - Partie 2: Spécifications des produits mis en oeuvreThermal insulation products for buildings - In-situ formed loose fill cellulose (LFCI) products - Part 2: Specification for the installed products91.100.60Thermal and sound insulating materialsICS:Ta slovenski standard je istoveten z:EN 15101-2:2013SIST EN 15101-2:2013en,fr,de01-november-2013SIST EN 15101-2:2013SLOVENSKI
STANDARD



SIST EN 15101-2:2013



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 15101-2
September 2013 ICS 91.100.60 English Version
Thermal insulation products for buildings - In-situ formed loose fill cellulose (LFCI) products - Part 2: Specification for the installed products
Produits isolants thermiques destinés aux applications du bâtiment - Isolation thermique formée en place à base de cellulose (LFCI) - Partie 2: Spécifications des produits mis en oeuvre
Wärmedämmstoffe für Gebäude - An der Verwendungsstelle hergestellter Wärmedämmstoff aus Zellulosefüllstoff (LFCI) - Teil 2: Spezifikation für die eingebauten Produkte This European Standard was approved by CEN on 8 August 2013.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15101-2:2013: ESIST EN 15101-2:2013



EN 15101-2:2013 (E) 2 Contents Page Foreword .4 1 Scope .5 2 Normative references .5 3 Terms, definitions, symbols and abbreviations .5 3.1 Terms and definitions .5 3.2 Symbols and abbreviations .6 3.2.1 Symbols used in this standard: .6 3.2.2 Abbreviations used in this standard.6 4 Requirements .7 4.1 General .7 4.2 Declared installed insulation thickness and declared installed insulation density for open blow applications (e.g. lofts) .7 4.3 Declared installed insulation thickness and declared installed insulation density for cavity applications (e.g. frame wall, roof and floor constructions) .7 5 Test methods .7 5.1 General .7 5.2 Declared installed insulation thickness .8 5.3 Declared installed insulation density .8 5.4 Frame method for the determination of declared installed density .8 5.5 Declared installed declared insulation density of cavity applications .8 5.5.1 Average cavity width .8 5.5.2 Machine output .8 5.5.3 Declared installed insulation density .8 6 Guidelines for installation .9 7 Installer’s declaration .9 Annex A (normative)
Open blow applications (lofts) – Determination of installed insulation thickness – Pin and plate method . 10 A.1 Apparatus . 10 A.2 Procedure . 10 Annex B (normative)
Cavity applications – Calculation for determining the declared installed insulation density in a construction . 12 B.1 Procedure . 12 B.2 Calculation . 12 Annex C (normative)
Cavity applications – Determination of average cavity width . 13 C.1 Procedure . 13 C.2 Calculation . 13 C.3 Floors . 13 Annex D (normative)
Cavity applications – Test box density (method of checking the blown density before installation into the wall) . 14 D.1 Apparatus . 14 D.2 Procedure . 14 D.3 Calculation . 14 Annex E (informative)
Example for installation guidelines . 15 E.1 Lofts . 15 E.1.1 Control tests made by the installer when preparing the product on site . 15 E.1.2 Installation procedure . 15 E.1.3 Installer’s declaration . 16 SIST EN 15101-2:2013



EN 15101-2:2013 (E) 3 E.2 Walls . 17 E.2.1 Suitability of the building to receive the insulation . 17 E.2.2 An example of a declaration form for use by the installer . 18 E.3 Frame constructions . 18 E.3.1 Suitability of the building to receive the insulation . 18 E.3.2 An example of a declaration form for use by the installer . 19 E.4 Floors . 19 E.4.1 Suitability of the structure to receive the insulation . 19 E.4.2 An example of a declaration form for use by the installer . 21 Bibliography . 22
SIST EN 15101-2:2013



EN 15101-2:2013 (E) 4 Foreword This document (EN 15101-2:2013) has been prepared by Technical Committee CEN/TC 88 “Thermal insulating materials and products”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by March 2014, and conflicting national standards shall be withdrawn at the latest by March 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This European Standard consists of two parts which form a package. The first part, which is the harmonised part, satisfying the mandate and the Construction Products Directive (CPD) and is the basis for the CE marking, covers the products which are placed on the market. The second part, which is the non-harmonised part, covers the specification for the installation checks for the installed products. Part 1 has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports the essential requirements of EU Directives. Attention is drawn to the need to take into account any complementary member state rules (e.g. installation rules) which together with this European Standard ensures the fitness for purpose of the installed product. This European Standard is one of a series of standards that include mineral wool, expanded clay, expanded perlite, exfoliated vermiculite, polyurethane/polyisocyanurate, cellulose and bound expanded polystyrene in-situ formed insulation products used in buildings, but this standard may be used in other areas where appropriate. The reduction in energy used and emissions produced during the installed life of insulation products exceeds by far the energy used and emissions made during the production and disposal processes. According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
SIST EN 15101-2:2013



EN 15101-2:2013 (E) 5 1 Scope This European Standard specifies requirements for in-situ formed loose-fill cellulose insulation (LFCI) products when installed as thermal insulation into walls, floors, galleries, roofs, lofts and ceilings. This Part 2 is a specification for the installation checks for the installed products.It specifies the checks and tests to be used for the declarations made by the installer of the product. This European Standard does not specify the required level of all properties to be achieved by a product to demonstrate fitness for purpose in a particular application. The required levels are to be found in regulations or non-conflicting standards. Products with a declared thermal conductivity at 10 °C (mean temperature) greater than 0,060 W/(m × K) or a declared thermal resistance lower than 0,25 m2 × K/W are not covered by this European Standard. This European Standard does not cover factory made cellulose mats, bats or quilts intended to be used for the insulation of buildings or in-situ cellulose products for the insulation of building equipment and industrial installations. Nor does it specify performance requirements. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 15101-1, Thermal insulation products for buildings — In-situ formed loose-fill cellulose (LFCI) products — Part 1: Specification for the products before installation 3 Terms, definitions, symbols and abbreviations
3.1 Terms and definitions
For the purposes of this document, the following terms and definitions apply. 3.1.1 open blow applications all the horizontal applications where the final upper surface of the installed insulation products remains uncovered EXAMPLE Galleries, lofts, ceilings and floors. 3.1.2 cavity applications applications where the installed insulation product is created in an enclosed space EXAMPLE Frame wall, roof and floor constructions. 3.1.3 floor horizontal division between two storeys, over a crawl space or a floor directly on the ground 3.1.4 settlement decrease of installed insulation thickness in lofts or height in cavities and frame constructions with vibrations, humidity, cyclic climate conditions and time, expressed as a percentage of the initial installed thickness
SIST EN 15101-2:2013



EN 15101-2:2013 (E) 6 3.1.5 coverage mass of insulation per unit area 3.1.6 performance chart table giving thickness and coverage requirements for different values of declared thermal resistance 3.1.7 system particular type of loose-fill cellulose insulation used in conjunction with a blowing machine with a blowing hose and nozzle 3.1.8 blowing hole hole, cut or formed, in a wall or frame construction, through which the cellulose is blown 3.1.9 declared installed thickness for open blow applications thickness as installed by the installer, prior to any settlement 3.1.10 loose-fill cellulose insulation (LFCI) fibre, fibrous or granulated insulation products derived from paper, paper stock and/or wood, leave or stalk strings with or without binders which are blown, injected or applied with or without moisture 3.1.11 frame wall, roof and floor constructions walls with wood or metal studs, sloping roof with insulation between and above rafters, as well as stud girders and internal and external insulation on solid masonry construction 3.2 Symbols and abbreviations 3.2.1 Symbols used in this standard: K is the declared installed insulation density Kg/m3 R is the thermal resistance m2 × K/W SH is the declared class for settlement for open blow applications
SC is the declared class of settlement for cavity applications
RD is the declared installed thermal resis
...

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Toplotnoizolacijski proizvodi za stavbe - Razsuti celulozni proizvodi za oblikovanje na mestu vgradnje - 2. del: Specifikacija za vgrajene proizvodeWärmedämmstoffe für Gebäude - An der Verwendungsstelle hergestellter Wärmedämmstoff aus Zellulosefüllstoff (LFCI) - Teil 2: Spezifikation für die eingebauten ProdukteProduits isolants thermiques destinés aux applications du bâtiment - Isolation thermique formée en place à base de cellulose (LFCI) - Partie 2: Spécifications des produits mis en oeuvreThermal insulation products for buildings - In-situ formed loose fill cellulose (LFCI) products - Part 2: Specification for the installed products91.100.60Thermal and sound insulating materialsICS:Ta slovenski standard je istoveten z:FprEN 15101-2kSIST FprEN 15101-2:2013en,fr,de01-april-2013kSIST FprEN 15101-2:2013SLOVENSKI
STANDARD



kSIST FprEN 15101-2:2013



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
FINAL DRAFT
FprEN 15101-2
February 2013 ICS 91.100.60 English Version
Thermal insulation products for buildings - In-situ formed loose fill cellulose (LFCI) products - Part 2: Specification for the installed products
Produits isolants thermiques destinés aux applications du bâtiment - Isolation thermique formée en place à base de cellulose (LFCI) - Partie 2: Spécifications des produits mis en oeuvre
Wärmedämmstoffe für Gebäude - An der Verwendungsstelle hergestellter Wärmedämmstoff aus Zellulosefüllstoff (LFCI) - Teil 2: Spezifikation für die eingebauten Produkte This draft European Standard is submitted to CEN members for unique acceptance procedure. It has been drawn up by the Technical Committee CEN/TC 88.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. FprEN 15101-2:2013: EkSIST FprEN 15101-2:2013



FprEN 15101-2:2013 (E) 2 Contents Page Foreword .41 Scope .52 Normative references .53 Terms, definitions, symbols and abbreviations .53.1 Terms and definitions .53.2 Symbols and abbreviations .63.2.1 Symbols used in this standard: .63.2.2 Abbreviations used in this standard.64 Requirements .64.1 General .64.2 Declared installed insulation thickness and declared installed insulation density for open blow applications (e.g. lofts) .74.3 Declared installed insulation thickness and declared installed insulation density for cavity applications (e.g. frame wall, roof and floor constructions) .75 Test methods .75.1 General .75.2 Declared installed insulation thickness .85.3 Declared installed insulation density .85.4 Frame method for the determination of declared installed density .85.5 Declared installed declared insulation density of cavity applications (e.g. wall, floor and frame constructions) .85.5.1 Average cavity width .85.5.2 Machine output .85.5.3 Declared installed insulation density .86 Guidelines for installation .97 Installer’s declaration .9Annex A (normative)
Open blow applications (lofts) – Determination of installed insulation thickness – Pin and plate method . 10A.1 Apparatus . 10A.2 Procedure . 10Annex B (normative)
Cavity applications – Calculation for determining the declared installed insulation density in a construction . 12B.1 Procedure . 12B.2 Calculation . 12Annex C (normative)
Cavity applications – Determination of average cavity width . 13C.1 Procedure . 13C.2 Calculation . 13C.3 Floors . 13Annex D (normative)
Cavity applications – Test box density (method of checking the blown density before installation into the wall) . 14D.1 Apparatus . 14D.2 Procedure . 14D.3 Calculation . 14Annex E (informative)
Example for installation guidelines . 15E.1 Lofts . 15E.1.1 Control tests made by the installer when preparing the product on site . 15E.1.2 Installation procedure . 15kSIST FprEN 15101-2:2013



FprEN 15101-2:2013 (E) 3 E.1.3 Installer’s declaration . 15E.2 Walls . 16E.2.1 Suitability of the building to receive the insulation . 16E.2.2 An example of a declaration form for use by the installer . 18E.3 Frame constructions . 18E.3.1 Suitability of the building to receive the insulation . 18E.3.2 An example of a declaration form for use by the installer . 19E.4 Floors . 19E.4.1 Suitability of the structure to receive the insulation . 19E.4.2 An example of a declaration form for use by the installer . 20Bibliography . 21 kSIST FprEN 15101-2:2013



FprEN 15101-2:2013 (E) 4 Foreword This document (FprEN 15101-2:2013) has been prepared by Technical Committee CEN/TC 88 “Thermal insulating materials and products”, the secretariat of which is held by DIN. This document is currently submitted to the Unique Acceptance Procedure. This European Standard consists of two parts which form a package. The first part, which is the harmonised part, satisfying the mandate and the CPD and is the basis for the CE marking, covers the products which are placed on the market. The second part, which is the non-harmonised part, covers the specification for the installation checks for the installed products. Part 1 has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports the essential requirements of EU Directives. Attention is drawn to the need to take into account any complementary member state rules (e.g. installation rules) which together with this European Standard ensures the fitness for purpose of the installed product. This European Standard contains five Annexes: Annex A (normative) Open blow applications (lofts) – Determination of installed insulation thickness – Pin and plate method Annex B (normative) Cavity applications – Calculation for determining the declared installed insulation density in a construction Annex C (normative)
Cavity applications – Determination of average cavity width
Annex D (normative) Cavity applications – Test box density (method of checking the blown density before installation into the wall) Annex E (normative) Installation guidelines This European Standard is one of a series of standards that include mineral wool, expanded clay, expanded perlite, exfoliated vermiculite, polyurethane/polyisocyanurate, cellulose and bound expanded polystyrene in-situ formed insulation products used in buildings, but this standard may be used in other areas where appropriate. The reduction in energy used and emissions produced during the installed life of insulation products exceeds by far the energy used and emissions made during the production and disposal processes. kSIST FprEN 15101-2:2013



FprEN 15101-2:2013 (E) 5 1 Scope This European Standard specifies requirements for in-situ formed loose-fill cellulose insulation (LFCI) products when installed as thermal insulation into walls, floors, galleries, roofs, lofts and ceilings. This Part 2 is a specification for the installation checks for the installed products. It specifies the checks and tests to be used for the declarations made by the installer of the product. This European Standard does not specify the required level of all properties to be achieved by a product to demonstrate fitness for purpose in a particular application. The required levels are to be found in regulations or non-conflicting standards. Products with a declared thermal conductivity at 10 °C (mean temperature) greater than 0,060 W/(m × K) or a declared thermal resistance lower than 0,25 m2 × K/W are not covered by this European Standard. This European Standard does not cover factory made cellulose mats, bats or quilts intended to be used for the insulation of buildings or in-situ cellulose products for the insulation of building equipment and industrial installations. Nor does it specify performance requirements. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. FprEN 15101-1, Thermal insulation products for buildings — In-situ formed loose-fill cellulose (LFCI) products — Part 1: Specification for the products before installation 3 Terms, definitions, symbols and abbreviations
3.1 Terms and definitions
For the purposes of this document, the following terms and definitions apply. 3.1.1 open blow applications all the horizontal applications where the final upper surface of the installed insulation products remains uncovered, for example, galleries, lofts, ceilings and floors 3.1.2 cavity applications applications where the installed insulation product is created in an enclosed space, for example, frame wall, roof and floor constructions 3.1.3 floor horizontal division between two storeys, over a crawl space or a floor directly on the ground 3.1.4 settlement decrease of installed insulation thickness in lofts or height in cavities and frame constructions with vibrations, humidity, cyclic climate conditions and time, expressed as a percentage of the initial installed thickness
3.1.5 coverage mass of insulation per unit area kSIST FprEN 15101-2:2013



FprEN 15101-2:2013 (E) 6 3.1.6 performance chart table giving thickness and coverage requirements for different values of declared thermal resistance 3.1.7 system particular type of loose-fill cellulose insulation used in conjunction with a blowing machine with a blowing hose and nozzle 3.1.8 blowing hole hole, cut or formed, in a wall or frame construction, through which the cellulose is blown 3.1.9 declared installed thickness for open blow applications thickness as installed by the installer, prior to any settlement 3.1.10 loose-fill cellulose insulation (LFCI) fibre, fibrous or granulated insulation products derived from paper, paper stock and/or wood, leave or stalk strings with or without binders which are blown, injected or applied with or without moisture 3.1.11 frame wall, roof and floor constructions walls with wood or metal studs, sloping roof with insulation between and above rafters, as well as stud girders and internal and external insulation on solid masonry construction 3.2 Symbols and abbreviations 3.2.1 Symbols used in this standard: d is the declared installed insulation thickness m R is the thermal resistance m2 × K/W RD is the declared installed thermal resistance m2 × K/W s is the relative reduction in thickness, due to settlement % Wp is the short-term water absorption kg/m2 λD is the declared thermal c
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.