SIST EN 13758-1:2002
(Main)Textiles - Solar UV protective properties - Part 1: Method of test for apparel fabrics
Textiles - Solar UV protective properties - Part 1: Method of test for apparel fabrics
This European Standard specifies a method for the determination of the erythemally weighted ultraviolet (UV) radiation transmittance of standard conditioned apparel fabrics to assess their solar UV protective properties.
This method is not suitable for fabrics which offer protection at a distance such as umbrellas, shade structures or artificial sources.
NOTE This standard may not be appropriate for fabrics with small colour and construction variations.
Textilien - Schutzeigenschaften gegen ultraviolette Sonnenstrahlung - Teil 1: Prüfverfahren für Bekleidungstextilien
Diese Europäische Norm legt ein Verfahren zur Bestimmung der Durchlässigkeit der hinsichtlich Erythem gewichteten ultravioletten Strahlung für normgerecht konditionierte Bekleidungstextilien zur Feststellung ihrer Schutzeigenschaften gegen ultraviolette Sonnenstrahlung fest.
Dieses Verfahren ist nicht für Textilien geeignet, die einen Schutz aus einem Abstand bieten, wie zum Beispiel Schirme, Konstruktionen zur Abschattung oder Vergleichbares.
ANMERKUNG Diese Norm braucht nicht für Textilien mit kleinen Variationen in der Farbe und im Aufbau geeignet zu sein.
Textiles - Propriétés de protection contre le rayonnement UV solaire - Partie 1: Méthode d'essai pour étoffes destinées a l'habillement
La présente Norme européenne spécifie une méthode pour la détermination du facteur de transmission du rayonnement ultraviolet (UV) pondéré par la courbe d'érytheme d'étoffes pour vetements en conditionnement normal en vue 'évaluer leurs propriétés de protection contre le rayonnement UV solaire.
La présente méthode ne convient pas aux étoffes offrant une protection a distance telles que les parasols, les structures destinées a créer de l'ombre ou les sources de rayonnement artificielles.
NOTE La présente norme peut s'avérer inappropriée pour des étoffes comportant de petites variations de couleur et de structure.
Tekstilije - Zaščitne lastnosti pred sončnimi ultravijoličnimi žarki - 1. del: Metoda preskušanja za oblačilne tekstilije
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Textiles - Solar UV protective properties - Part 1: Method of test for apparel fabricsTextiles - Propriétés de protection contre le rayonnement UV solaire - Partie 1: Méthode d'essai pour étoffes destinées a l'habillementTextilien - Schutzeigenschaften gegen ultraviolette Sonnenstrahlung - Teil 1: Prüfverfahren für BekleidungstextilienTa slovenski standard je istoveten z:EN 13758-1:2001SIST EN 13758-1:2002en61.0202EODþLODClothes59.080.30TkanineTextile fabricsICS:SLOVENSKI
STANDARDSIST EN 13758-1:200201-junij-2002
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13758-1November 2001ICS 59.080.30; 61.020English versionTextiles - Solar UV protective properties - Part 1: Method of testfor apparel fabricsTextilien - Schutzeigenschaften gegen ultravioletteSonnenstrahlung - Teil 1: Prüfverfahren fürBekleidungstextilienThis European Standard was approved by CEN on 5 October 2001.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2001 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13758-1:2001 E
EN 13758-1:2001 (E)2ForewordThis European Standard has been prepared by Technical Committee CEN/TC 248, "Textiles andtextile products", the secretariat of which is held by BSI.This European Standard shall be given the status of a national standard, either by publication of anidentical text or by endorsement, at the latest by May 2002, and conflicting national standards shall bewithdrawn at the latest by May 2002.This standard includes a normative annex A and informative annexes B and C.According to the CEN/CENELEC Internal Regulations, the national standards organizations of thefollowing countries are bound to implement this European Standard: Austria, Belgium, CzechRepublic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg,Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom.
EN 13758-1:2001 (E)31 ScopeThis European Standard specifies a method for the determination of the erythemally weightedultraviolet (UV) radiation transmittance of standard conditioned apparel fabrics to assess their solarUV protective properties.This method is not suitable for fabrics which offer protection at a distance such as umbrellas, shadestructures or artificial sources.NOTEThis standard may not be appropriate for fabrics with small colour and construction variations.2 Normative referencesThis European Standard incorporates by dated or undated reference, provisions from otherpublications. These normative references are cited at the appropriate place in the text, and thepublications are listed hereafter. For dated references, subsequent amendments to or revisions of anyof these publications apply to this European Standard only when incorporated in it by amendment orrevision. For undated references the latest edition of the publication referred to applies (includingamendments).EN 20139:1992, Textiles — Standard atmospheres for conditioning and testing (ISO 139:1973).3 Terms, definitions and abbreviationsFor the purposes of this European Standard the following terms and definitions apply.3.1.1wavelength ()spatial period of radiation expressed in nanometres3.1.2ultraviolet radiation (UVR)electromagnetic radiation with wavelength between 180 and 400 nmUV-A: ultraviolet radiation with wavelength between 315 and 400 nmUV-B: ultraviolet radiation with wavelength between 280 and 315 nm3.1.3solar irradiance (E())quantity of energy emitted by the sun received at the surface of the earth per unit wavelength and perunit area. It is expressed as W m-2 nm-1. The solar UVR spectrum as measured at the earth’s surfaceextends between 290 nm and 400 nm3.1.4erythemareddening of the skin caused by various physical or chemical agents3.1.5erythema action spectrum ()relative erythemal effectiveness of radiation with wavelength
EN 13758-1:2001 (E)43.1.6spectral transmittance T()ratio of transmitted radiation and incident radiation at a wavelength 3.1.7integrating spherehollow sphere whose internal surface is a non-selective diffuse reflector3.1.8fluorescenceabsorption of radiation of a particular wavelength and its re-emission within a short time as opticalradiation of greater wavelength3.1.9spectral bandwidthwidth in nanometres at half peak intensity of optical radiation emerging from a monochromator3.1.10sample recess errorerror introduced when the sample is recessed from the port of the integrating sphere (e.g. by using afilter between the port and the sample). In this case part of the diffused transmitted radiation isintercepted and will not enter the sphere. The sample recess error depends on sample construction,distance of sample from port and ratio of port and illumination patch dimensions3.1.11shadeparticular hue, depth or lightness of colour3.1.12constructionset of parameters such as materials, interlacing, pattern, … which describe the fabric3.1.13Ultraviolet Protection Factor (UPF)expression of the level of protection as attained by the method described in this standard4 PrincipleThe UPF of a textile material is determined from the total spectral transmittance)(T as follows:)()()(290400)()(290400TEEUPFwith:)(E:the solar irradiance (see annex A);)(:the erythema action spectrum (see annex A);:the wavelength interval of the measurements;T():the spectral transmittance at wavelength .
EN 13758-1:2001 (E)5The total spectral transmittance is measured by irradiating the sample with monochromatic orpolychromatic UV radiation and collecting the total (diffuse and direct) transmitted radiation. In thecase of polychromatic incident radiation, the transmitted radiation is collected monochromatically. Theapparatus shall either irradiate the sample with a parallel beam and collect all transmitted radiationwith an integrating sphere or irradiate the sample hemispherically and collect a parallel beam oftransmitted radiation.5 ApparatusThe measurement device consists of the following:5.1A UV source, providing UV radiation throughout the wavelength range 290 nm to 400 nm.Suitable UV sources include Xenon arc lamps, Deuterium lamps and Solar simulators.5.2An integrating sphere, having total openings representing not more than 10 % of the internalspherical surface. The internal surface shall be lined with a highly reflective matt surface, e.g. bariumsulphate paint. It shall be fitted with baffles to shield the inner detector or the inner source from thespecimen port and, if applicable, the sphere wall where the incident flux is measured.5.3A monochromator, suited for measurements with a spectral bandwidth of 5 nm or less in thewavelength region 290 nm to 400 nm.5.4UV transmitting filter, which transmits significantly only at wavelengths less thanapproximately 400 nm and which does not fluoresce.5.5A specimen holder to hold a specimen in a flat, tensionless or in a predefined stretched state.This device shall not obstruct the entrance port of the integrating sphere and shall ideally position thefabric in the plane of the integrating sphere port.In the case where a parallel incident beam is used, the surface of the beam should be at least 25 mm2and should cover at least 3 times the repeat fabric construction. Moreover, in the case of amonochromatic incident beam and for reducing the sample recess error, the ratio of the smallestdimension of the port of the integrating sphere to the largest dimension of the illumination patch shallalso be larger than 1,5. The beam should be normal to the fabric to within ± 5 degrees. The angulardivergence of the beam should be less then 5 degrees about the beam axis. These conditions shouldapply to the collected beam if diffuse illumination is used.A suitable UV transmitting filter shall be positioned between the sample and the detector if theinstrument monochromates before the sample. When this
...