Thermal insulation products for buildings - In-situ formed expanded clay lightweight aggregate products - Part 2: Specification for the installed products

This European Standard specifies the requirements for loose-fill expanded clay lightweight aggregate (LWA) products installed in roofs, ceilings, floors and ground floors. This Part 2 is a specification for the installed product. Part 2 of this European Standard describes, when taken together with Part 1, the product characteristics that are linked to the essential requirements of the EU Construction Products Directive. Part 2 also specifies the checks and tests to be used for the declarations made by the installer of the product. Part 2 of this European Standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in national regulations or non conflicting standards. This European Standard does not cover factory made expanded clay lightweight aggregate products or in-situ products intended to be used for the insulation of building equipment and industrial installations. This European Standard does not specify performance requirements for airborne sound insulation and for acoustic absorption applications.

Wärmedämmstoffe für Gebäude - An der Verwendungsstelle hergestellte Wärmedämmung aus Blähton-Leichtzuschlagsstoffen (LWA) - Teil 2: Spezifikation für die eingebauten Produkte

Diese Europäische Norm legt die Anforderungen an Blähton-Leichtzuschlagsstoffe (LWA), eingebaut in Dächern, Decken, Fußböden und Böden in nicht unterkellerten Gebäuden, fest.
Teil 2 dieser Norm ist eine Spezifikation für das eingebaute Produkt.
Bei Anwendung mit Teil 1 dieser Norm beschreibt es die Merkmale, die im Zusammenhang stehen mit den grundlegenden Anforderungen der EU-Bauproduktenrichtlinie. Teil 2 dieser Norm beinhaltet die Überprüfungen und Prüfungen, die für die vom Monteur für das Produkt abzugebende Erklärung anzuwenden sind.
Teil 2 dieser Europäischen Norm legt keine Anforderungsniveaus für eine vorgegebene Eigenschaft fest, die ein Produkt erreichen muss, um für einen bestimmten Anwendungsfall tauglich zu sein. Für bestimmte Anwendungen benötigte Anforderungen können nationalen Regelwerken oder übereinstimmenden Normen entnommen werden.
Diese Europäische Norm gilt nicht für werksmäßig hergestellte Produkte aus Blähton-Leichtzuschlagsstoffen (LWA) oder an der Verwendungsstelle hergestellte Produkte, die für Anwendungen zur Dämmung von haustechnischen und betriebstechnischen Anlagen vorgesehen sind.
In dieser Europäischen Norm werden keine Funktionsanforderungen für Luftschalldämmung und an die akustische Schalldämmung festgelegt.

Produits isolants thermiques pour le bâtiment - Produits à base de granulats légers d'argile expansée formés en place - Partie 2: Spécifications relatives aux produits installés

La présente Norme européenne fixe les exigences concernant les produits en vrac de granulats légers d'argile expansée, installés dans les toitures, plafonds et planchers y compris sur terre-plein.
Cette Partie 2 est une spécification relative au produit installé.
La Partie 2 de cette Norme européenne décrit, conjointement avec la Partie 1, les caractéristiques du produit liées aux exigences essentielles de la Directive européenne relative aux produits de construction. Cette Partie 2 spécifie également les contrôles et les essais à utiliser pour les déclarations faites par l’installateur du produit.
Elle ne spécifie pas le niveau requis d'une propriété donnée devant être atteint par un produit pour en démontrer l'aptitude à la fonction dans une application particulière. Les niveaux requis pour une application donnée sont indiqués dans la règlementation nationale ou dans des normes non contradictoires.
La présente Norme européenne ne couvre ni les granulats légers d'argile expansée fabriqués en usine, ni les produits in situ destinés à l’isolation d’équipements de bâtiments et d’installations industrielles.
La présente Norme européenne ne spécifie pas d'exigences de performance pour les applications d'isolement aux bruits aériens et d'absorption acoustique.

Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz ekspandiranega glinenega agregatnega proizvoda (LWA), oblikovani na mestu vgradnje - 2. del: Specifikacija za vgrajene izolacijske proizvode

Ta standard določa zahteve za lahke polnilne proizvode iz ekspandiranega glinenega agregatnega proizvoda (LWA), nameščene v strehah, stropih, nadstropjih in tleh. 2. del je specifikacija nameščenega proizvoda. 2. del tega evropskega standarda skupaj s 1. delom opisuje lastnosti proizvoda, ki so povezane z osnovnimi zahtevami direktive o konstrukciji proizvodov. Določa tudi preglede in preskuse, ki se uporabijo za deklaracije, ki jih ustvari monter proizvoda. 2. del tega evropskega standarda ne določa zahtevane ravni določene lastnosti, ki jo mora proizvod doseči, da se dokaže njegova primernost za namen v okviru izbranega načina uporabe. Zahtevane ravni za posamezen način uporabe so določene v državnih uredbah ali standardih, ki niso v nasprotju s tem standardom. Ta evropski standard ne zajema proizvodov iz tovarniškega ekspandiranega glinenega agregatnega proizvoda (LWA) ali proizvodov, oblikovanih na mestu vgradnje, namenjenih za izolacijo opreme stavb in industrijskih inštalacij. Ta evropski standard ne določa zahtev za zmogljivost izolirnosti pred zvokom v zraku in aplikacij za absorpcijo zvoka.

General Information

Status
Published
Public Enquiry End Date
27-Feb-2013
Publication Date
10-Sep-2013
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
19-Jul-2013
Due Date
23-Sep-2013
Completion Date
11-Sep-2013

Buy Standard

Standard
EN 14063-2:2013
English language
13 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Draft
k FprEN 14063-2:2013
English language
13 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 14063-2:2013
01-oktober-2013
Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz ekspandiranega glinenega
agregatnega proizvoda (LWA), oblikovani na mestu vgradnje - 2. del: Specifikacija
za vgrajene izolacijske proizvode
Thermal insulation products for buildings - In-situ formed expanded clay lightweight
aggregate products - Part 2: Specification for the installed products
Wärmedämmstoffe für Gebäude - An der Verwendungsstelle hergestellte
Wärmedämmung aus Blähton-Leichtzuschlagsstoffen (LWA) - Teil 2: Spezifikation für die
eingebauten Produkte
Produits isolants thermiques pour le bâtiment - Produits à base de granulats légers
d'argile expansée formés en place - Partie 2: Spécifications relatives aux produits
installés
Ta slovenski standard je istoveten z: EN 14063-2:2013
ICS:
91.100.60 0DWHULDOL]DWRSORWQRLQ Thermal and sound insulating
]YRþQRL]RODFLMR materials
SIST EN 14063-2:2013 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 14063-2:2013

---------------------- Page: 2 ----------------------

SIST EN 14063-2:2013


EUROPEAN STANDARD
EN 14063-2

NORME EUROPÉENNE

EUROPÄISCHE NORM
July 2013
ICS 91.100.60
English Version
Thermal insulation products for buildings - In-situ formed
expanded clay lightweight aggregate products - Part 2:
Specification for the installed products
Produits isolants thermiques pour le bâtiment - Produits à Wärmedämmstoffe für Gebäude - An der
base de granulats légers d'argile expansée formés en place Verwendungsstelle hergestellte Wärmedämmung aus
- Partie 2: Spécifications relatives aux produits installés Blähton-Leichtzuschlagsstoffen (LWA) - Teil 2:
Spezifikation für die eingebauten Produkte
This European Standard was approved by CEN on 23 May 2013.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2013 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 14063-2:2013: E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN 14063-2:2013
EN 14063-2:2013 (E)
Contents Page
Foreword .3
1 Scope .4
2 Normative references .4
3 Terms, definitions, symbols, units and abbreviated terms .4
3.1 Terms and definitions .4
3.2 Symbols and units .5
3.3 Abbreviated terms .5
4 Requirements .5
4.1 General .5
4.2 Guidelines for installation .5
4.3 Declared installed thermal resistance, R .6
D
4.4 Declared installed insulation thickness, d .6
m
4.5 Declared moisture content .6
4.6 Settlement .6
4.7 Compaction .6
5 In-situ measurements and calculations .7
5.1 Calculation of the declared mean installed insulation thickness .7
5.2 Calculation of declared installed thermal resistance, R .7
D
6 Installer’s declaration .7
Annex A (normative) Method for the determination of density and degree of compaction of the
installed product .8
A.1 Principle .8
A.2 Apparatus .8
A.3 Test specimens, samples .9
A.4 Procedure .9
A.4.1 Test conditions .9
A.4.2 Test procedure .9
A.5 Calculation and expression of results .9
A.6 Precision . 10
A.7 Test report . 11
Annex B (normative) Installation guidelines . 12
B.1 Suitability of the building to receive the insulation product . 12
B.2 Tests made by the installer when preparing the product on site . 12
B.3 Installation procedure . 12
B.4 Installer's declaration . 12
Bibliography . 13

2

---------------------- Page: 4 ----------------------

SIST EN 14063-2:2013
EN 14063-2:2013 (E)
Foreword
This document (EN 14063-2:2013) has been prepared by Technical Committee CEN/TC 88 "Thermal
insulating materials and products", the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by January 2014, and conflicting national standards shall be withdrawn at
the latest by January 2014.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
This European standard consists of two parts. The first part is the harmonised part satisfying the mandate and
the CPD. It is the basis for the CE marking covering the products, which are placed on the market. The
second part, which is the non-harmonised part, covers the specification for the installed products. Both parts
need to be used for the application of the insulation products in the end-use applications covered by
EN 14063.
Part 1 of this European Standard has been prepared under a mandate given to CEN by the European
Commission and the European Free Trade Association and supports the essential requirements of EU
Directives. For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of Part 1.
Attention is drawn to the need to take into account any complementary member state rules (e.g. installation
rules) which together with this European Standard ensures the fitness for purpose of the installed product.
This European Standard is one of a series for mineral wool, expanded clay, expanded perlite, exfoliated
vermiculite, polyurethane/polyisocyanurate, cellulose, bound expanded polystyrene and expanded polystyrene
in-situ formed insulation products used in buildings, but this standard can be used in other areas where
appropriate.
The reduction in energy used and emissions produced during the installed life of insulation products exceeds
by far the energy used and emissions made during the production and disposal processes.
According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
3

---------------------- Page: 5 ----------------------

SIST EN 14063-2:2013
EN 14063-2:2013 (E)
1 Scope
This European Standard specifies the requirements for loose-fill expanded clay lightweight aggregate (LWA)
products installed in roofs, ceilings, floors and ground floors.
This Part 2 is a specification for the installed product.
Part 2 of this European Standard describes, when taken together with Part 1, the product characteristics that
are linked to the essential requirements of the EU Construction Products Directive. Part 2 also specifies the
checks and tests to be used for the declarations made by the installer of the product.
Part 2 of this European Standard does not specify the required level of a given property to be achieved by a
product to demonstrate fitness for purpose in a particular application. The levels required for a given
application are to be found in national regulations or non conflicting standards.
This European Standard does not cover factory made expanded clay lightweight aggregate products or in-situ
products intended to be used for the insulation of building equipment and industrial installations.
This European Standard does not specify performance requirements for airborne sound insulation and for
acoustic absorption applications.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
EN 823:2013, Thermal insulating products for building applications — Determination of thickness
EN 1097-3, Tests for mechanical and physical properties of aggregates — Par
...

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz ekspandiranega glinenega agregatnega proizvoda (LWA), oblikovani na mestu vgradnje - 2. del: Specifikacija za vgrajene izolacijske proizvodeWärmedämmstoffe für Gebäude - An der Verwendungsstelle hergestellte Wärmedämmung aus Blähton-Leichtzuschlagsstoffen (LWA) - Teil 2: Spezifikation für die eingebauten ProdukteProduits isolants thermiques pour le bâtiment - Produits à base de granulats légers d'argile expansée formés en place - Partie 2: Spécifications relatives aux produits installésThermal insulation products for buildings - In-situ formed expanded clay lightweight aggregate products - Part 2: Specification for the installed products91.100.60Thermal and sound insulating materialsICS:Ta slovenski standard je istoveten z:FprEN 14063-2kSIST FprEN 14063-2:2013en,fr,de01-februar-2013kSIST FprEN 14063-2:2013SLOVENSKI
STANDARD



kSIST FprEN 14063-2:2013



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
FINAL DRAFT
FprEN 14063-2
November 2012 ICS 91.100.60 English Version
Thermal insulation products for buildings - In-situ formed expanded clay lightweight aggregate products - Part 2: Specification for the installed products
Produits isolants thermiques pour le bâtiment - Produits à base de granulats légers d'argile expansée formés en place - Partie 2: Spécifications relatives aux produits installés
Wärmedämmstoffe für Gebäude - An der Verwendungsstelle hergestellte Wärmedämmung aus Blähton-Leichtzuschlagsstoffen (LWA) - Teil 2: Spezifikation für die eingebauten Produkte This draft European Standard is submitted to CEN members for unique acceptance procedure. It has been drawn up by the Technical Committee CEN/TC 88.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. FprEN 14063-2:2012: EkSIST FprEN 14063-2:2013



FprEN 14063-2:2012 (E) 2 Contents Page Foreword .31 Scope .42 Normative references .43 Terms, definitions, symbols, units and abbreviated terms .43.1 Terms and definitions .43.2 Symbols and units .53.3 Abbreviated terms .54 Requirements .54.1 General .54.2 Guidelines for installation .54.3 Declared installed thermal resistance, RD .64.4 Declared installed insulation thickness, dm .64.5 Declared moisture content .64.6 Settlement .64.7 Compaction .65 In-situ measurements and calculations .75.1 Calculation of the declared mean installed insulation thickness .75.2 Declared calculation of installed thermal resistance, RD .76 Installer’s declaration .7Annex A (normative)
Method for the determination of density and degree of compaction of the installed product .8A.1 Principle .8A.2 Apparatus .8A.3 Test specimens, samples .9A.4 Procedure .9A.4.1 Test conditions .9A.4.2 Test procedure .9A.5 Calculation and expression of results .9A.6 Precision . 10A.7 Test report . 11Annex B (normative)
Installation guidelines . 12B.1 Suitability of the building to receive the insulation product . 12B.2 Tests made by the installer when preparing the product on site . 12B.3 Installation procedure . 12B.4 Installer's declaration . 12Bibliography . 13 kSIST FprEN 14063-2:2013



FprEN 14063-2:2012 (E) 3 Foreword This document (FprEN 14063-2:2012) has been prepared by Technical Committee CEN/TC 88 “Thermal insulating materials and products”, the secretariat of which is held by DIN. This document is currently submitted to the Unique Acceptance Procedure. This European standard consists of two parts. The first part is the harmonised part satisfying the mandate and the CPD. It is the basis for the CE marking covering the products, which are placed on the market. The second part, which is the non-harmonised part, covers the specification for the installed products. Both parts need to be used for the application of the insulation products in the end-use applications covered by EN 14063. Part 1 of this European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association and supports the essential requirements of EU Directives. For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of Part 1. Attention is drawn to the need to take into account any complementary member state rules (e.g. installation rules) which together with this European Standard ensures the fitness for purpose of the installed product. Part 2 of this European Standard contains two annexes: − Annex A (normative)
Method for the determination of density and degree of compaction of the installed product − Annex B (normative)
Installation Guidelines
This European Standard is one of a series for mineral wool, expanded clay, expanded perlite, exfoliated vermiculite, polyurethane/polyisocyanurate, cellulose, bound expanded polystyrene and expanded polystyrene in-situ formed insulation products used in buildings, but this standard can be used in other areas where appropriate.
The reduction in energy used and emissions produced during the installed life of insulation products exceeds by far the energy used and emissions made during the production and disposal processes. kSIST FprEN 14063-2:2013



FprEN 14063-2:2012 (E) 4 1 Scope
This European Standard specifies the requirements for loose-fill expanded clay lightweight aggregate (LWA) products installed in roofs, ceilings, floors and ground floors.
This Part 2 is a specification for the installed product. Part 2 of this European Standard describes, when taken together with Part 1, the product characteristics that are linked to the essential requirements of the EU Construction Products Directive. Part 2 also specifies the checks and tests to be used for the declarations made by the installer of the product. Part 2 of this European Standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in national regulations or non conflicting standards. This European Standard does not cover factory made expanded clay lightweight aggregate products or in-situ products intended to be used for the insulation of building equipment and industrial installations. This European Standard does not specify performance requirements for airborne sound insulation and for acoustic absorption applications.
2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 823:1994, Thermal insulating products for building applications — Determination of thickness