Thermal insulation products for buildings - Factory made rigid polyurethane foam (PU) products - Specification

This European Standard specifies the requirements for factory made rigid polyurethane foam (PU) products, with or without facings or coatings, which are used for the thermal insulation of buildings. PU includes both PIR and PUR products. The products are manufactured in the form of boards.
This standard includes PU multi-layered insulation products. Instructions of Annex D shall be followed.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required class/level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The classes/levels required for a given application are to be found in regulations or non conflicting standards.
Products with a declared thermal resistance lower than 0,25 m2 K/W or a declared thermal conductivity greater than 0,060 W/(m K) at 10 °C are not covered by this European Standard.
This standard does not cover in situ insulation products, products intended to be used for the insulation of building equipment and industrial installations.

Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Polyurethan-Hartschaum (PU) - Spezifikation

Produits isolants thermiques pour le bâtiment - Produits manufacturés en mousse rigide de polyuréthane (PU) - Spécification

Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz trde poliuretanske pene (PUR) - Specifikacija

General Information

Status
Not Published
Public Enquiry End Date
13-Nov-2014
Technical Committee
Current Stage
98 - Abandoned project (Adopted Project)
Start Date
17-Mar-2015
Due Date
22-Mar-2015
Completion Date
17-Mar-2015

Relations

Buy Standard

Draft
EN 13165:2013/kFprA1:2014
English language
17 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 13165:2013/kFprA1:2014
01-november-2014
Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz trde poliuretanske pene
(PUR) - Specifikacija
Thermal insulation products for buildings - Factory made rigid polyurethane foam (PU)
products - Specification
Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Polyurethan-
Hartschaum (PU) - Spezifikation
Produits isolants thermiques pour le bâtiment - Produits manufacturés en mousse rigide
de polyuréthane (PU) - Spécification
Ta slovenski standard je istoveten z: EN 13165:2012/FprA1
ICS:
91.100.60 0DWHULDOL]DWRSORWQRLQ Thermal and sound insulating
]YRþQRL]RODFLMR materials
SIST EN 13165:2013/kFprA1:2014 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 13165:2013/kFprA1:2014

---------------------- Page: 2 ----------------------

SIST EN 13165:2013/kFprA1:2014

EUROPEAN STANDARD
FINAL DRAFT
EN 13165:2012
NORME EUROPÉENNE

EUROPÄISCHE NORM
FprA1
August 2014
ICS 91.100.60
English Version
Thermal insulation products for buildings - Factory made rigid
polyurethane foam (PU) products - Specification
Produits isolants thermiques pour le bâtiment - Produits Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte
manufacturés en mousse rigide de polyuréthane (PU) - Produkte aus Polyurethan-Hartschaum (PU) - Spezifikation
Spécification
This draft amendment is submitted to CEN members for unique acceptance procedure. It has been drawn up by the Technical Committee
CEN/TC 88.

This draft amendment A1, if approved, will modify the European Standard EN 13165:2012. If this draft becomes an amendment, CEN
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of this amendment
into the relevant national standard without any alteration.

This draft amendment was established by CEN in three official versions (English, French, German). A version in any other language made
by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has
the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 13165:2012/FprA1:2014 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN 13165:2013/kFprA1:2014
EN 13165:2012/FprA1:2014 (E)
Contents Page
Foreword .3
1 Modification to the Foreword .4
2 Modifications to the Scope .4
3 Modification to 3.2, Symbols, units and abbreviated terms .4
4 Modification to 4.3.4, Compressive stress or compressive strength .5
5 Modification to 4.3.11, Release of dangerous substances .5
6 Modification to Clause 7, Evaluation of conformity .6
7 Modification to Clause 8, Marking and labelling .6
8 Modification to Annex B, Initial type testing (ITT) and factory production control (FPC) .6
9 Modification to Annex ZA, Clauses of this European Standard addressing the provisions
of the EU Construction Products Directive .7

2

---------------------- Page: 4 ----------------------

SIST EN 13165:2013/kFprA1:2014
EN 13165:2012/FprA1:2014 (E)
Foreword
This document (EN 13165:2012/FprA1:2014) has been prepared by Technical Committee CEN/TC 88
“Thermal insulating materials and products”, the secretariat of which is held by DIN.
This document is currently submitted to the Unique Acceptance Procedure.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Construction Products Regulation (CPR), see informative Annex ZA, which is an
integral part of this standard.
NOTE Due to fact that the Framework Partnership Agreement between the Commission and CEN & CENELEC is not
signed yet, there are currently no New Approach Consultants in place for 2014. Therefore the provisions of CEN-
CENELEC Guide 15 cannot be met.
This shall not prevent the processing of draft standards nor the offering of harmonized standards to the Commission. In
particular, draft standards can be sent to vote without Consultant assessment.
This note will be removed from the Foreword of the finalized publication.

This amendment (EN 13165:2012/FprA1:2014) modifies the European Standard EN 13165:2012 identifying
those clauses of the standard which are needed for the compliance of the European Standard with the
Construction Products Regulation (CPR).
This amendment introduces
a) an addition to the foreword;
b) an addition in 3.2;
c) a new subclause 4.3.11;
d) modification of Clause 7;
e) modification of Clause 8;
f) modification of Annex B;
g) a new Annex ZA.
3

---------------------- Page: 5 ----------------------

SIST EN 13165:2013/kFprA1:2014
EN 13165:2012/FprA1:2014 (E)
1 Modification to the Foreword
th
Replace the 6 paragraph with:
"For relationship with EU Construction Products Regulation (CPR), see informative Annex ZA, which is an
integral part of this standard.".
2 Modifications to the Scope
st
After the 1 paragraph, add:
"This European Standard includes PU multi-layered insulation products, see Annex D."
nd
In the 2 paragraph, replace "composite panels" with "composite insulation products".
3 Modification to 3.2, Symbols, units and abbreviated terms
Replace
"ITT is Initial Type Test" with
"PTD is Product Type Determination (previously named ITT for Initial Type Test)"
and add the following abbreviated terms:
"AVCP is Assessment and Verification of Constancy of Performance (previously named attestation of
conformity)
DoP is Declaration of Performance
ThIB is Thermal Insulation for Buildings
VCP is Verification of Constancy of Performance (previously named evaluation of conformity)".
4

---------------------- Page: 6 ----------------------

SIST EN 13165:2013/kFprA1:2014
EN 13165:2012/FprA1:2014 (E)
4 Modification to 4.3.4, Compressive stress or compressive strength
Replace Table 8 with the following:
"
Table 8 — Levels for compressive stress or compressive strength
Level Requirement
kPa
CS(10\Y)25 ≥ 25
CS(10\Y)50
≥ 50
CS(10\Y)100 ≥ 100
CS(10\Y)120 ≥ 120
CS(10\Y)130 ≥ 130
CS(10\Y)140 ≥ 140
CS(10\Y)150
≥ 150
CS(10\Y)175
≥ 175
CS(10\Y)200
≥ 200
CS(10\Y)225
≥ 225
CS(10\Y)250
≥ 250
Values higher than 250 kPa can be declared in steps of 50 kPa.
".
5 Modification to 4.3.11, Release of dangerous substances
Replace the text of 4.3.11 with:
"National regulations on dangerous substances may require verification and declaration on release, and
sometimes content, when construction products covered by this standard are placed on those markets.
In the absence of European harmonized test methods, verification and declaration on release/content should
be done taking into account national provisions in the place of use.
NOTE An informative database covering European and national provisions on dangerous substances is available at
the Construction web site on EUROPA accessed through: http://ec.europa.eu/enterprise/construction/cpd-ds/.".
5

---------------------- Page: 7 ----------------------

SIST EN 13165:2013/kFprA1:2014
EN 13165:2012/FprA1:2014 (E)
6 Modification to Clause 7, Evaluation of conformity
Replace Clause 7 with:
"
7 Assessment and Verification of the Constancy of Performance (AVCP)
7.1 General
The manufacturer or his authorized representative shall be responsible for the conformity of his product with
the requirements of this European Standard. The Assessment and Verification of Constancy of Performance
(AVCP) shall be carried out in accordance with EN 13172 and shall be based on Product Type Determination
(PTD), Factory Production Control (FPC) by the manufacturer, including product assessment and tests on
samples taken at the factory.
The compliance of the product with the requirements of this standard and with the stated values (including
classes) shall be demonstrated by:
 Product Type Determination (PTD),
 Factory Production Control (FPC) by the manufacturer, including product assessment.
If a manufacturer decides to group his products, it shall be done in accordance with EN 13172.
7.2 Product Type Determination (PTD)
All characteristics defined in 4.2 and those in 4.3 if declared, shall be subject to Product Type Determination
(PTD) in accordance with Annex B.
For the relevant characteristics, PTD on products corresponding also to EN 14308 may be used for the
purpose of PTD and Declaration of Performance (DoP) according to this standard.
7.3 Factory Production Control (FPC)
The minimum frequencies of tests in the factory production control (FPC) shall be in accordance with
Annex B. When indirect testing is used, the correlation to direct testing shall be established in accordance with
EN 13172.
For the relevant characteristics, FPC on products corresponding also to EN 14308 may be used for the
purpose of FPC and DoP according to this standard.".
7 Modification to Clause 8, Marking and labelling
Add the following indent: "
 the intended use of the rigid polyurethane foam for insulation of buildings is given by the abbreviation
ThlB.".
8 Modification to Annex B, Initial type testing (ITT) and factory production control
(FPC)
Replace "Initial type testing" with "Product type determination" and "ITT" with "PTD" within Annex B in:
 Annex B, title;
 Table B.1, title;
6

---------------------- Page: 8 ----------------------

SIST EN 13165:2013/kFprA1:2014
EN 13165:2012/FprA1:2014 (E)
rd st
 Table B.1, 3 column, 1 line, title;
rd
 Table B.1, 3 column, line 4.2.1;
 Table B.1, text of footnote b;
 Table B.1, text of footnote d.
9 Modification to Annex ZA, Clauses of this European Standard addressing the
provisions of the EU Construction Products Directive
Replace the existing Annex ZA with the following new Annex ZA:
"
Annex ZA
(informative)

Clauses of this European Standard addressing the provisions of the
EU Construction Products Regulation
ZA.1 Scope and relevant characteristics
1)
This European Standard has been prepared under Mandate M/103 "Thermal insulation products" given to CEN
by the European Commission and the European Free Trade Association.
If this European standard is cited in the Official Journal of the European Union (OJEU), the clauses of this
standard, shown in this annex, are considered to meet the provisions of the relevant mandate, under the
Regulation (EU) No. 305/2011.
This annex deals with the CE marking of the factory made rigid polyurethane foam intended for the use
indicated in Table ZA.1 and shows the relevant clauses applicable.
This annex has the same scope as Clause 1 of this standard related to the aspects covered by the mandate
and is defined by Table ZA.1.

1)
As amended by mandates M126, M130 and M367
7

---------------------- Page: 9 ----------------------

SIST EN 13165:2013/kFprA1:2014
EN 13165:2012/FprA1:2014 (E)
Table ZA.1 — Relevant clauses for factory made rigid polyurethane foam and intended use
Product: Factory made rigid polyurethane foam (PU) products
Intended use: Thermal insulation for buildings
Clauses in this and other European
Regulatory


Essential Characteristics standard(s) related to essential Notes
classes
a
characteristics
4.2.1 Thermal resistance and Declared R and λ
D D

thermal conductivity
Thermal resistance if possible
Declared d
4.2.3 Thickness —
N
4.2.6 Reaction to fire of the
Reaction to fire  product as placed on the Euroclasses —
market
4.2.7.2 Durability of reaction to fire
Durability of reaction to fire against
b
of the product as placed on Euroclasses
heat, weathering, ageing/degradation


the market
Declared R and λ
4.2.1 Thermal resistance and
D D


thermal conductivity
if possible
4.2.7.3 Durability characteristics — Declared R and λ
D D

c
— Declared DS
Durability of thermal resistance 4.3.2 Dimensional stability
against heat, weathering,
4.3.3 Deformation under specified
ageing/degradation

compressive load and — Declared DLT
temperature conditions
Annex C Determination of the aged
Declared λ
values of thermal resistance —
D
and thermal conductivity
4.3.4 Compressive stress or
Compressive strength — Declared CS
d
compressive strength
4.3.5 Tensile strength
Tensile/Flexural strength
— Declared TR

perpendicular to faces
Durability of compressive strength
4.3.6 Compressive creep — Declared CC
against ageing/degradation
Declared WS(P),
4.3.7.1 or Short term water absorption
— WL(P) and/ or
4.3.7.2 Long term water absorption
WL(T)
Water permeability
4.3.8 Flatness after one sided
— Declared FW
wetting
Water vapour permeability 4.3.9 Water vapour transmission — Declared MU and/ or Z
Acoustic absorption index 4.3.10 Sound absorption — Declared AP and AW
4.3.11 Release of dangerous
Release of dangerous substances to
— —
e
the indoor environment substances
4.3.13 Continuous glowing
Continuous glowing combustion — —
e
combustion
a
Also valid and applicable for multilayers.
b
The fire performance of PU does not deteriorate with time.
c
For dimensional stability thickness only.
d
This characteristic also covers handling and installation.
e
European test methods are under development.
The declaration of the product performance related to certain essential characteristics is not required in those
Member States (MS) where there are no regulatory requirements on these essential characteristics for the
intended use of the product. In this case, manufacturers placing their products on the market of these MS are
8

---------------------- Page: 10 ----------------------

SIST EN 13165:2013/kFprA1:2014
EN 13165:2012/FprA1:2014 (E)
not obliged to determine nor declare the performance of their products with regard to these essential
characteristics and the option “No performance determined” (NPD) in the information accompanying the CE
marking and in the declaration of performance (see ZA.3) may be used for those essential characteristics.
ZA.2 Procedures for AVCP of factory made rigid polyurethane foam products
ZA.2.1 Systems of AVCP
The AVCP systems of factory made rigid polyurethane foam indicated in Table ZA.1, established by EC
Decision 95/204/EC of 31.05.95 (OJ L 129) revised by decision 99/91/EC of 25.01.99 (OJ L 29) amended by
th
the decision 01/596/EC of 8 January 2001 (OJ L 209) is shown in Table ZA.2 for the indicated intended use
and relevant level(s) or class(es) of performance.
Table ZA.2 — Systems of AVCP
Level(s)
or class(es)
Product(s) Intended use(s) AVCP system(s)
(reaction to fire)
a
Thermal insulation products For uses subject to (A1, A2, B, C) 1
(Factory made products) regulations on reaction to fire
b
(A1, A2, B, C) , D, E 3
c
(A1 to E) , F 4
Any — 3
System 1: See Regulation (EU) No. 305/2011 (CPR) Annex V, 1.2
System 3: See Regulation (EU) No. 305/2011 (CPR) Annex V, 1.4
System 4: See Regulation (EU) No. 305/2011 (CPR) Annex V, 1.5
a
Products/materials for which a clearly identifiable stage in the production process results in an improvement of the reaction to fire
classification (e.g. an addition of fire retardants or a limiting of organic material).
a
b
Products/materials not covered by footnote ( ).
c
Products/materials that do not require to be tested for reaction to fire (e.g. products/materials of classes A1 according to