This part of IEC 61300 describes the test procedure to test the wind resistance of a protective
housing and its mounting hardware using the fastening parts recommended by the
manufacturer. The protective housing is considered to have a cuboid shape.
The applied force in this test procedure simulates a steady wind load from each direction to a
protective housing and its mounting hardware fixed to a support.
Lichtwellenleiter - Verbindungselemente und passive Bauteile – Grundlegende Prüf- und Messverfahren – Teil 2-56: Prüfungen - Windfestigkeit von angebauten Gehäusen (IEC 61300-2-56:2020)
Dispositifs d’interconnexion et composants passifs fibroniques - Procédures fondamentales d'essais et de mesures - Partie 2-56: Essais - Résistance au vent des boîtiers installés (IEC 61300-2-56:2020)
IEC 61300-2-56:2020 décrit la procédure d'essai pour soumettre à des essais la résistance au vent d'un boîtier de protection et de son matériel d'installation utilisant les éléments de fixation recommandés par le fabricant. Le boîtier de protection est considéré comme étant de forme parallélépipédique. La force appliquée dans cette procédure d'essai simule une charge du vent régulière dans chaque direction appliquée à un boîtier de protection et son matériel d'installation fixés sur un support.
Optični spojni elementi in pasivne komponente - Osnovni preskusni in merilni postopki - 2-56. del: Preskusi - Vetrna odpornost pritrjenega ohišja (IEC 61300-2-56:2020)
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN IEC 61300-2-56:2020
01-december-2020
Optični spojni elementi in pasivne komponente - Osnovni preskusni in merilni
postopki - 2-56. del: Preskusi - Vetrna odpornost pritrjenega ohišja (IEC 61300-2-
56:2020)
Fibre optic interconnecting devices and passive components - Basic test and
measurement procedure - Part 2-56: Tests - Wind resistance of mounted housing (IEC
61300-2-56:2020)
Lichtwellenleiter - Verbindungselemente und passive Bauteile – Grundlegende Prüf- und
Messverfahren – Teil 2-56: Prüfungen - Windfestigkeit von angebauten Gehäusen (IEC
61300-2-56:2020)
Dispositifs d’interconnexion et composants passifs fibroniques - Procédures
fondamentales d'essais et de mesures - Partie 2-56: Essais - Résistance au vent des
boîtiers installés (IEC 61300-2-56:2020)
Ta slovenski standard je istoveten z: EN IEC 61300-2-56:2020
ICS:
33.180.20 Povezovalne naprave za Fibre optic interconnecting
optična vlakna devices
SIST EN IEC 61300-2-56:2020 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN IEC 61300-2-56:2020
---------------------- Page: 2 ----------------------
SIST EN IEC 61300-2-56:2020
EUROPEAN STANDARD EN IEC 61300-2-56
NORME EUROPÉENNE
EUROPÄISCHE NORM
October 2020
ICS 33.180.20
English Version
Fibre optic interconnecting devices and passive components -
Basic test and measurement procedures - Part 2-56: Tests -
Wind resistance of mounted housing
(IEC 61300-2-56:2020)
Dispositifs d'interconnexion et composants passifs Lichtwellenleiter - Verbindungselemente und passive
fibroniques - Procédures fondamentales d'essais et de Bauteile - Grundlegende Prüf- und Messverfahren - Teil 2-
mesures - Partie 2-56: Essais - Résistance au vent des 56: Prüfungen - Windfestigkeit von angebauten Gehäusen
boîtiers installés (IEC 61300-2-56:2020)
(IEC 61300-2-56:2020)
This European Standard was approved by CENELEC on 2020-09-22. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2020 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 61300-2-56:2020 E
---------------------- Page: 3 ----------------------
SIST EN IEC 61300-2-56:2020
EN IEC 61300-2-56:2020 (E)
European foreword
The text of document 86B/4300/FDIS, future edition 1 of IEC 61300-2-56, prepared by SC 86B "Fibre
optic interconnecting devices and passive components" of IEC/TC 86 "Fibre optics" was submitted to
the IEC-CENELEC parallel vote and approved by CENELEC as EN IEC 61300-2-56:2020.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2021-06-22
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2023-09-22
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
Endorsement notice
The text of the International Standard IEC 61300-2-56:2020 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following note has to be added for the standard indicated:
IEC 61753-1 NOTE Harmonized as EN IEC 61753-1
2
---------------------- Page: 4 ----------------------
SIST EN IEC 61300-2-56:2020
EN IEC 61300-2-56:2020 (E)
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments)
applies.
NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available
here: www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 61300-1 - Fibre optic interconnecting devices and EN 61300-1 -
passive components - Basic test and
measurement procedures - Part 1:
General and guidance
IEC 61300-3-1 - Fibre optic interconnecting devices and EN 61300-3-1 -
passive components - Basic test and
measurement procedures - Part 3-1:
Examinations and measurements - Visual
examination
3
---------------------- Page: 5 ----------------------
SIST EN IEC 61300-2-56:2020
---------------------- Page: 6 ----------------------
SIST EN IEC 61300-2-56:2020
IEC 61300-2-56
®
Edition 1.0 2020-08
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures –
Part 2-56: Tests – Wind resistance of mounted housing
Dispositifs d’interconnexion et composants passifs fibroniques – Procédures
fondamentales d'essais et de mesures –
Partie 2-56: Essais – Résistance au vent des boîtiers installés
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 33.180.20 ISBN 978-2-8322-8731-6
Warning! Make sure that you obtained this publication from an authorized distributor.
Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.
® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale
---------------------- Page: 7 ----------------------
SIST EN IEC 61300-2-56:2020
– 2 – IEC 61300-2-56:2020 © IEC 2020
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references . 7
3 Terms and definitions . 7
4 General description . 7
5 Apparatus . 8
5.1 Loading method . 8
5.1.1 General . 8
5.1.2 Method for pole-mounted housing . 8
5.1.3 Method for ground-mounted housing . 11
5.2 Force generator . 11
5.3 Force gauge . 12
5.4 Holding fixture . 12
5.5 Force applying device . 12
5.6 Timer . 12
6 Procedure . 12
6.1 General . 12
6.2 Pre-conditioning . 12
6.3 Initial examination . 12
6.4 Mounting DUT . 12
6.5 Conditioning . 13
6.6 Recovery . 13
6.7 Final examination . 13
7 Severity . 13
8 Details to be specified . 14
Annex A (normative) Testing pole-mounted protective housings with vertical load
application . 15
A.1 General . 15
A.2 Method for pole-mounted housing with vertical load application . 15
A.3 Severities . 16
Annex B (informative) Calculation of force resulting from wind load . 17
B.1 Formula of force resulting from wind load . 17
B.2 Example of force calculation . 17
B.3 Calculation of factor for frontal load application of pole-mounted housing . 18
B.4 Calculation of factor for lateral load application of pole-mounted housing . 19
B.5 Calculation of factor for vertical load application of pole-mounted housing . 20
B.6 Calculation of factor for frontal load application of ground-mounted housing . 20
B.7 Calculation of factor for lateral load application of ground-mounted housing . 20
Bibliography . 21
Figure 1 – Dimensions of pole-mounted and ground-mounted housing . 8
Figure 2 – Side view of frontal load application . 9
Figure 3 – Front view of frontal load application . 9
Figure 4 – Side view of lateral load application . 10
---------------------- Page: 8 ----------------------
SIST EN IEC 61300-2-56:2020
IEC 61300-2-56:2020 © IEC 2020 – 3 –
Figure 5 – Front view of lateral load application . 10
Figure 6 – Isometric view of frontal load application . 11
Figure 7 – Isometric view of lateral load application . 11
Figure A.1 – Side view of vertical load application . 15
Figure A.2 – Front view of vertical load application . 16
Figure B.1 – Worst-case situation for frontal load application . 18
Figure B.2 – Model with wind load on one side only . 18
Figure B.3 – Model for calculation of F from F . 19
T R
Table 1 – Recommended severity values for pole-mounted housing . 13
Table 2 – Recommended severity values for ground-mounted housing . 14
Table A.1 – Recommended severity value for pole-mounted housing and vertical load
application . 16
Table B.1 – Examples of drag coefficients . 17
---------------------- Page: 9 ----------------------
SIST EN IEC 61300-2-56:2020
– 4 – IEC 61300-2-56:2020 © IEC 2020
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
FIBRE OPTIC INTERCONNECTING
DEVICES AND PASSIVE COMPONENTS –
BASIC TEST AND MEASUREMENT PROCEDURES –
Part 2-56: Tests – Wind resistance of mounted housing
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent
rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61300-2-56 has been prepared by subcommittee 86B: Fibre optic
interconnecting devices and passive components, of IEC technical committee 86: Fibre optics.
The text of this International Standard is based on the following documents:
FDIS Report on voting
86B/4300/FDIS 86B/4325/RVD
Full information on the voting for the approval of this International Standard can be found in the
report on voting indicated in the above table.
This document has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts in the IEC 61300 series, published under the general title Fibre optic
interconnecting devices and passive components – Basic test and measurement procedures,
can be found on the IEC website.
---------------------- Page: 10 ----------------------
SIST EN IEC 61300-2-56:2020
IEC 61300-2-56:2020 © IEC 2020 – 5 –
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to
the specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
---------------------- Page: 11 ----------------------
SIST EN IEC 61300-2-56:2020
– 6 – IEC 61300-2-56:2020 © IEC 2020
INTRODUCTION
Outdoor protective housings are exposed to wind load. The housing fixings should be able to
withstand the force of the wind without damage to or movement of the housing or its fixings.
The method defined in this document provides reproducible conditions for testing the wind
resistance of protective housings and their mounting hardware, either pole-mounted or ground-
mounted, in two different horizontal directions (frontal and lateral). Additionally, the conditions
for optional testing the wind resistance of pole-mounted protective housings in vertical direction
are given.
Depending on the installation and the location, the wind speed can be very different. Even in
the same geographic location, the wind speed can vary considerably with height above the
ground (e.g. at the top of a mast). Recommended severities are included in this document and
considered as a minimum.
Annex A provides reproducible conditions for testing the wind resistance of pole-mounted
protective housings in vertical direction.
Annex B provides information for the calculation of the resulting force on the protective housing
from wind load.
---------------------- Page: 12 ----------------------
SIST EN IEC 61300-2-56:2020
IEC 61300-2-56:2020 © IEC 2020 – 7 –
FIBRE OPTIC INTERCONNECTING
DEVICES AND PASSIVE COMPONENTS –
BASIC TEST AND MEASUREMENT PROCEDURES –
Part 2-56: Tests – Wind resistance of mounted housing
1 Scope
This part of IEC 61300 describes the test procedure to test the wind resistance of a protective
housing and its mounting hardware using the fastening parts recommended by the
manufacturer. The protective housing is considered to have a cuboid shape.
The applied force in this test procedure simulates a stead
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.