Plastics piping systems for non-pressure underground drainage and sewerage - Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 3: Specifications for pipes and fittings with smooth internal and profiled external surface and the system, Type B

This part of EN 13476, together with EN 13476-1, specifies the definitions and requirements for pipes, fittings and the system based on unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) structured-wall piping systems that are intended to be used for non-pressure underground drainage and sewerage systems.
This part is applicable to pipes and fittings with smooth internal and profiled external surfaces, designated as Type B.
It specifies test methods and test parameters as well as requirements.
This part is applicable to:
a)   structured-wall pipes and fittings, which are intended to be used buried underground outside the building structure, reflected in the marking of products by "U";
b)   structured-wall pipes and fittings, which are intended to be used buried underground both outside (application area code "U") and within the building structure (application area code "D"), reflected in the marking of products by "UD".
This part is applicable to structured-wall pipes and fittings with or without an integral socket with elastomeric ring seal joints as well as welded and fused joints.
This part covers a range of pipe and fitting sizes, materials, pipe constructions, stiffness classes, application classes, and tolerance classes and gives recommendations concerning colours.
NOTE 1   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
NOTE 2   For dimensions larger than DN 1200 OD/ID this document may be applied regarding appearance, colour, physical and mechanical characteristics as well as performance requirements.

Kunststoff-Rohrleitungssysteme für erdverlegte drucklose Abwasserkanäle und -leitungen - Rohrleitungssysteme mit profilierter Wandung aus weichmacherfreiem Polyvinylchlorid (PVC-U), Polypropylen (PP) und Polyethylen (PE) - Teil 3: Anforderungen an Rohre und Formstücke mit glatter Innen- und profilierter Außenfläche und an das Rohrleitungssystem, Typ B

Dieser Teil von EN 13476 legt gemeinsam mit EN 13476-1 die Definitionen und Anforderungen für Rohre,
Formstücke und das Rohrleitungssystem aus weichmacherfreiem Polyvinylchlorid (PVC-U), Polypropylen
(PP) und Polyethylen (PE) mit profilierter Wandung fest, die für erdverlegte, drucklos betriebene
Abwasserkanäle und –leitungen verwendet werden.
Dieser Teil gilt für Rohre und Formstücke mit glatten Innen- und profilierten Außenflächen, bezeichnet als
Typ B.
Es werden sowohl Prüfverfahren und Prüfparameter als auch Anforderungen festgelegt.
Dieser Teil gilt für:
a) Rohre und Formstücke mit profilierter Wandung, die ausschließlich für erdverlegte Anwendungen
außerhalb einer Gebäudestruktur vorgesehen sind; gekennzeichnet mit Anwendungskennzeichen „U“.
b) Rohre und Formstücke mit profilierter Wandung, die sowohl für erdverlegte Anwendungen außerhalb der
Gebäudestruktur (Anwendungskennzeichen „U“) als auch innerhalb einer Gebäudestruktur
(Anwendungskennzeichen „D“) vorgesehen sind; gekennzeichnet mit Anwendungskennzeichen „UD“.
Dieser Teil gilt für Rohre und Formstücke mit profilierter Wandung sowohl mit glatten Enden als auch mit
angeformter Muffe, die mittels elastomerer Dichtringverbindungen bzw. durch Heizelement-Stumpf-,
Extrusions- oder Heizwendelschweißen miteinander verbunden sind.
Diese Norm enthält Festlegungen für Maße von Rohren und Formstücken, für Werkstoffe,
Rohrkonstruktionen, für Steifigkeitsklassen, Anwendungs- und Toleranzklassen und gibt Empfehlungen für die
Einfärbung.
ANMERKUNG 1 Der Anwender bzw. Auftraggeber ist unter Berücksichtigung der eigenen Anforderungen sowie der
geltenden nationalen Festlegungen und Verlegepraktiken oder -vorschriften für die entsprechende Auswahl dieser
Kriterien verantwortlich.
ANMERKUNG 2 Für Durchmesser größer DN 1 200 OD/ID kann dieses Dokument für Beschaffenheit, Farbe,
physikalische und mechanische Eigenschaften sowie Anforderungen an die Gebrauchstauglichkeit angewendet werden.

Systèmes de canalisations en plastique pour les branchements et les collecteurs d'assainissement sans pression enterrés - Systèmes de canalisations à parois structurées en poly(chlorure de vinyle) non plastifié (PVC-U), polypropylène (PP) et polyéthylène (PE) - Partie 3: Spécifications pour les tubes et raccords avec une surface interne lisse et une surface externe profilée et le système, de Type B

La présente partie de l’EN 13476, conjointement avec l’EN 13476-1, spécifie les définitions et les exigences pour les
tubes, les raccords et le système de canalisations fabriqués à partir de poly(chlorure de vinyle) non plastifié (PVC-U),
polypropylène (PP) et polyéthylène (PE), destinés à être utilisés en tant que systèmes de canalisations à parois
structurées dans le domaine des branchements et des collecteurs d'assainissement enterrés sans pression.
La présente partie s'applique aux tubes et raccords avec une surface interne lisse et une surface externe profilée,
désignés de Type B.
Elle spécifie les méthodes d'essai et les paramètres d'essai ainsi que les exigences.
La présente partie s'applique aux :
a) tubes et raccords à parois structurées, destinés à être utilisés enterrés à l'extérieur du bâtiment ; ce qui est reflété
par le marquage des produits par «U» ;
b) tubes et raccords à parois structurées, destinés à être utilisés enterrés, aussi bien à l'extérieur (code de la zone
d’application «U») de la structure des bâtiments, qu’à l'intérieur (code de la zone d’application «D») ; ce qui est
reflété par le marquage des produits par «UD».
La présente partie s'applique aux tubes et raccords à parois structurées qui comprennent des assemblages à bague
d'étanchéité en élastomère avec ou sans emboîture intégrée ainsi que des assemblages soudés et les assemblages
obtenus par fusion.
La présente partie couvre une gamme de dimensions de tubes et de raccords, de matières, de constructions de tube,
de classes de rigidité, de classes d'application et de classes de tolérance et donne des recommandations concernant
les couleurs.
NOTE 1 Il est de la responsabilité de l'acheteur ou du prescripteur de faire les sélections appropriées à partir de ces aspects,
en tenant compte des exigences particulières et des règles nationales concernées et des pratiques ou codes de pose.

Cevni sistemi iz polimernih materialov za odvodnjavanje in kanalizacijo, ki delujejo po težnostnem principu in so položeni v zemljo - Cevni sistemi s strukturirano steno iz nemehčanega polivinilklorida (PVC-U), polipropilena (PP) in polietilena (PE) - 3. del: Specifikacije za cevi, fitinge z gladko notranjo in profilirano zunanjo površino in sistem, tip B

General Information

Status
Withdrawn
Publication Date
04-May-2009
Withdrawal Date
16-May-2018
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
17-May-2018
Due Date
09-Jun-2018
Completion Date
17-May-2018

Relations

Buy Standard

Standard
EN 13476-3:2007+A1:2009
English language
46 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Kunststoff-Rohrleitungssysteme für erdverlegte drucklose Abwasserkanäle und -leitungen - Rohrleitungssysteme mit profilierter Wandung aus weichmacherfreiem Polyvinylchlorid (PVC-U), Polypropylen (PP) und Polyethylen (PE) - Teil 3: Anforderungen an Rohre und Formstücke mit glatter Innen- und profilierter Außenfläche und an das Rohrleitungssystem, Typ BSystèmes de canalisations en plastique pour les branchements et les collecteurs d'assainissement sans pression enterrés - Systèmes de canalisations à parois structurées en poly(chlorure de vinyle) non plastifié (PVC-U), polypropylène (PP) et polyéthylène (PE) - Partie 3: Spécifications pour les tubes et raccords avec une surface interne lisse et une surface externe profilée et le système, de Type BPlastics piping systems for non-pressure underground drainage and sewerage - Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 3: Specifications for pipes and fittings with smooth internal and profiled external surface and the system, Type B93.030Zunanji sistemi za odpadno vodoExternal sewage systems23.040.20Cevi iz polimernih materialovPlastics pipesICS:Ta slovenski standard je istoveten z:EN 13476-3:2007+A1:2009SIST EN 13476-3:2007+A1:2009en,fr,de01-junij-2009SIST EN 13476-3:2007+A1:2009SLOVENSKI
STANDARD



SIST EN 13476-3:2007+A1:2009



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13476-3:2007+A1
January 2009 ICS 93.030 Supersedes EN 13476-3:2007English Version
Plastics piping systems for non-pressure underground drainage and sewerage - Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 3: Specifications for pipes and fittings with smooth internal and profiled external surface and the system, Type B
Systèmes de canalisations en plastique pour les branchements et les collecteurs d'assainissement sans pression enterrés - Systèmes de canalisations à parois structurées en poly(chlorure de vinyle) non plastifié (PVC-U), polypropylène (PP) et polyéthylène (PE) - Partie 3: Spécifications pour les tubes et raccords avec une surface interne lisse et une surface externe profilée et le système, de Type B
Kunststoff-Rohrleitungssysteme für erdverlegte drucklose Abwasserkanäle und -leitungen - Rohrleitungssysteme mit profilierter Wandung aus weichmacherfreiem Polyvinylchlorid (PVC-U), Polypropylen (PP) und Polyethylen (PE) - Teil 3: Anforderungen an Rohre und Formstücke mit glatter Innen- und profilierter Außenfläche und an das Rohrleitungssystem, Typ B This European Standard was approved by CEN on 5 March 2007 and includes Amendment 1 approved by CEN on 27 November 2008.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36
B-1050 Brussels © 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13476-3:2007+A1:2009: ESIST EN 13476-3:2007+A1:2009



EN 13476-3:2007+A1:2009 (E) 2 Contents Page Foreword .41Scope .72Normative references .73Terms, Definitions, symbols and abbreviations .93.1Definitions .93.2Symbols .93.3Abbreviations . 104Material . 114.1General . 114.2Unplasticized poly(vinyl chloride) (PVC-U) . 114.2.1General . 114.2.2Pipe and fitting material characteristics . 114.2.3Utilisation of non-virgin materials . 124.3Polypropylene (PP) . 124.3.1General . 124.3.2Pipe and fitting material characteristics . 124.3.3Melt mass-flow rate classification. 134.3.4Utilisation of non-virgin materials . 144.4Polyethylene (PE). 144.4.1General . 144.4.2Material characteristics of pipes and injection-moulded fittings . 144.4.3Material characteristics of rotational-moulded fittings . 154.4.4Utilisation of non-virgin materials . 154.4.5Sealing ring retaining components. 154.5Sealing rings . 154.6Fused or welded joints . 154.7Adhesives for PVC-U . 165Designation of wall constructions and examples of typical jointing methods . 165.1Wall constructions designated as Type B . 165.1.1Ribbed or corrugated construction . 165.1.2Typical jointing methods for structured-wall type B . 175.2Designation and design of joints . 186Appearance and colour . 197Geometrical characteristics . 197.1General . 197.2Dimensions . 197.2.1Designation . 197.2.2Lengths of pipe . 197.2.3Diameters . 197.2.4Diameters and jointing dimensions of sockets and spigots . 217.2.5Wall thicknesses . 227.3Types of fittings . 257.4Design length of fittings . 258Physical characteristics . 258.1Unplastisized poly(vinyl chloride) (PVC-U) . 258.1.1Physical characteristics of PVC-U pipes . 258.1.2Physical characteristics of PVC-U fittings . 258.2Polypropylene (PP) . 268.2.1Physical characteristics of PP pipes . 268.2.2Physical characteristics of PP fittings . 268.3Polyethylene (PE). 278.3.1Physical characteristics of PE pipes . 27SIST EN 13476-3:2007+A1:2009



EN 13476-3:2007+A1:2009 (E) 3 8.3.2Physical characteristics of PE fittings . 279Mechanical characteristics . 289.1Mechanical characteristics of pipes . 289.1.1General requirements . 289.1.2Ring flexibility . 299.1.3Tensile strength . 309.2Mechanical characteristics of fittings . 3010Performance requirements . 3111Marking . 3311.1General . 3311.2Minimum required marking . 3311.2.1Pipes . 3311.2.2Fittings . 3411.3Additional marking . 3411.3.1General . 3411.3.2Third party certified pipes and fittings . 34Annex A (normative)
Virgin PVC-U material . 35Annex B (normative)
Utilisation of non-virgin PVC-U material . 36B.1Reprocessable and recyclable material from pipes and fittings . 36B.2External reprocessable and recyclable materials with agreed specification . 36B.3External reprocessable and recyclable materials not covered by an agreed specification . 36Annex C (normative)
Virgin PP material . 38Annex D (normative)
Utilisation of non-virgin PP material . 39D.1Reprocessable and recyclable material from pipes and fittings . 39D.2External reprocessable and recyclable materials with an agreed specification . 39D.3External reprocessable and recyclable materials not covered by an agreed specification . 39Annex E (normative)
Virgin PE material . 40Annex F (normative)
Utilisation of non-virgin PE material . 41F.1Reprocessable and recyclable material from pipes and fittings . 41F.2External reprocessable and recyclable materials with an agreed specification . 41F.3External reprocessable and recyclable materials not covered by an agreed specification . 41F.4External reprocessable and recyclable material from PE rotational-moulded fittings and other components . 42Annex G (normative)
Impact test at 23 °C . 43Annex H (normative)
Impact test at −−−−10 °C . 44Annex I (normative)
Ring flexibility test at 20 % diametric deflection . 45Annex J (informative)
Survey of possible use of reprocessable and recyclable material . 46 SIST EN 13476-3:2007+A1:2009



EN 13476-3:2007+A1:2009 (E) 4 Foreword This document (EN 13476-3:2007+A1:2009) has been prepared by Technical Committee CEN/TC 155 “Plastics piping systems and ducting systems”, the secretariat of which is held by NEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by July 2009, and conflicting national standards shall be withdrawn at the latest by July 2009. This document includes Amendment 1, approved by CEN on 2008-11-27. This document supersedes EN 13476-3:2007. The start and finish of text introduced or altered by amendment is indicated in the text by tags !"This standard is a Part of a System Standard for plastics piping systems of particular materials for a specified application. There are a number of such System Standards. System Standards are based on the results of the work being undertaken in ISO/TC 138 “Plastics pipes, fittings and valves for the transport of fluids”, which is a Technical Committee of the International Organization for Standardization (ISO). They are supported by separate standards on test methods to which references are made throughout the System Standard. The System Standards are consistent with general standards on functional requirements and on recommended practice for installation. EN 13476 consists of the following Parts under the general title Plastics piping systems for non-pressure underground drainage and sewerage - Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE):  Part 1: General requirements and performance characteristics;  Part 2: Specifications for pipes and fittings with smooth internal and external surface and the system, Type A;  Part 3: Specifications for pipes and fittings with smooth internal and profiled external surface and the system, Type B (this standard);  Part 4: Assessment of conformity (CEN/TS).  !deleted text" For pipes and fittings which have conformed to the relevant national standard before May 2007, as shown by the manufacturer or by a certification body, the national standard may continue to be applied until May 2009.
National standards specifically for pipes and fittings for the transport of surface water are not considered to be conflicting with this standard and may thus be allowed to coexist. SIST EN 13476-3:2007+A1:2009



EN 13476-3:2007+A1:2009 (E) 5 According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
SIST EN 13476-3:2007+A1:2009



EN 13476-3:2007+A1:2009 (E) 6 Introduction This standard provides optional choices for impact resistance (see Annex G and Annex H) and ring flexibility (see Annex I). As appropriate, the individual countries may select between those options in their national forewords. SIST EN 13476-3:2007+A1:2009



EN 13476-3:2007+A1:2009 (E) 7 1 Scope This part of EN 13476, together with EN 13476-1, specifies the definitions and requirements for pipes, fittings and the system based on unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) structured-wall piping systems that are intended to be used for non-pressure underground drainage and sewerage systems. This part is applicable to pipes and fittings with smooth internal and profiled external surfaces, designated as Type B. It specifies test methods and test parameters as well as requirements. This part is applicable to: a) structured-wall pipes and fittings, which are intended to be used buried underground outside the building structure, reflected in the marking of products by “U”; b) structured-wall pipes and fittings, which are intended to be used buried underground both outside (application area code “U”) and within the building structure (application area code “D”), reflected in the marking of products by “UD”. This part is applicable to structured-wall pipes and fittings with or without an integral socket with elastomeric ring seal joints as well as welded and fused joints. This part covers a range of pipe and fitting sizes, materials, pipe constructions, stiffness classes, application classes, and tolerance classes and gives recommendations concerning colours. NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
NOTE 2 For dimensions larger than DN 1200 OD/ID this document may be applied regarding appearance, colour, physical and mechanical characteristics as well as performance requirements. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 476, General requirements for components used in discharge pipes, drains and sewers for gravity systems EN 580, Plastics piping systems  Unplasticized poly(vinyl chloride) (PVC-U) pipes  Test method for the resistance to dichloromethane at a specified temperature (DCMT) EN 681-1, Elastomeric seals  Materials requirements for pipe joint seals used in water and drainage applications  Part 1: Vulcanized rubber EN 681-2, Elastomeric seals  Materials requirements for pipe joint seals used in water and drainage applications  Part 2: Thermoplastic elastomers EN 681-4, Elastomeric seals  Materials requirements for pipe joint seals used in water and drainage applications  Part 4: Cast polyurethane sealing elements EN 727, Plastics piping and ducting systems  Thermoplastics pipes and fittings  Determination of Vicat softening temperature (VST) SIST EN 13476-3:2007+A1:2009



EN 13476-3:2007+A1:2009 (E) 8 EN 728, Plastics piping and ducting systems  Polyolefin pipes and fittings  Determination of oxidation induction time EN 744, Plastics piping and ducting systems  Thermoplastics pipes  Test method for resistance to external blows by the round-the-clock method EN 922, Plastics piping and ducting systems  Pipes and fittings of unplasticized poly(vinyl chloride) (PVC-U)  Specimen preparation for determination of the viscosity number and calculation of the K-value EN 1053, Plastics piping systems  Thermoplastics piping systems for non-pressure applications  Test method for watertightness EN 1055:1996, Plastics piping systems  Thermoplastics piping systems for soil and waste discharge inside buildings  Test method for resistance to elevated temperature cycling EN 1277, Plastics piping systems  Thermoplastics piping systems for buried non-pressure applications  Test methods for leaktightness of elastomeric sealing ring type joints EN 1401-1, Plastics piping systems for non-pressure underground drainage and sewerage  Unplasticized poly(vinyl chloride) (PVC-U)  Part 1: Specifications for pipes, fittings and the system EN 1411, Plastics piping and ducting systems  Thermoplastics pipes  Determination of resistance to external blows by the staircase method EN 1437, Plastics piping systems  Piping systems for underground drainage and sewerage  Test method for resistance to combined temperature cycling and external loading EN 1446, Plastics piping and ducting systems  Thermoplastics pipes  Determination of ring flexibility EN 1852-1, Plastics piping systems for non-pressure underground drainage and sewerage  Polypropylene (PP)  Part 1: Specifications for pipes, fittings and the system EN 1905, Plastics piping systems  Unplasticized poly(vinyl chloride) (PVC-U) pipes, fittings and material — Method for assessment of the PVC content based on total chlorine content EN 1979, Plastics piping and ducting systems  Thermoplastics spirally-formed structured-wall pipes  Determination of the tensile strength of a seam EN 12061, Plastics piping systems  Thermoplastics fittings  Test method for impact resistance EN 12256, Plastics piping systems  Thermoplastics fittings  Test method for mechanical strength or flexibility of fabricated fittings EN 12666-1, Plastics piping systems for non-pressure underground drainage and sewerage  Polyethylene (PE)  Part 1: Specifications for pipes, fittings and the system EN 13476-1:2007, Plastics piping systems for non-pressure underground drainage and sewerage  Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE)  Part 1: General requirements and performance characteristics EN 13476-2:2007,
Plastics piping systems for non-pressure underground drainage and sewerage  Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE)  Part 2: Specifications for pipes and fittings with smooth internal and external surface and the system, Type A CEN/TS 14541:2007, Plastics pipes and fittings for non-pressure applications  Utilisation of non-virgin PVC-U, PP and PE materials SIST EN 13476-3:2007+A1:2009



EN 13476-3:2007+A1:2009 (E) 9 EN 14741, Thermoplastics piping and ducting systems  Joints for buried non-pressure applications  Test method for the long-term sealing performance of joints with elastomeric seals by estimating the sealing pressure EN 14758-1, Plastics piping systems for non-pressure underground drainage and sewerage  Polypropylene with mineral modifiers (PP-MD)  Part 1: Specifications for pipes, fittings and the system EN ISO 580, Plastics piping and ducting systems  Injection-moulded thermoplastics fittings  Methods for visually assessing the effects of heating (ISO 580:2005) EN ISO 1133:2005, Plastics  Determination of the melt mass-flow rate (MFR) and the melt volume-flow rate (MVR) of thermoplastics (ISO 1133:2005) EN ISO 1167-1, Thermoplastics pipes, fittings and assemblies for the conveyance of fluids  Determination of the resistance to internal pressure  Part 1: General method (ISO 1167-1:2006) EN ISO 1167-2, Thermoplastics pipes, fittings and assemblies for the conveyance of fluids  Determination of the resistance to internal pressure  Part 2: Preparation of pipe test pieces (ISO 1167-2:2006) EN ISO 1183-1, Plastics  Methods for determining the density of non-cellular plastics  Part 1: Immersion method, liquid pyknometer and titration method (ISO 1183-1:2004) EN ISO 3126, Plastics piping systems  Plastics piping components  Determination of dimensions
(ISO 3126:2005) EN ISO 3451-1, Plastics  Determination of ash  Part 1: General methods (ISO 3451-1:1997) EN ISO 9967, Plastics pipes  Determination of creep ratio (ISO 9967:1994) EN ISO 9969, Thermoplastics pipes  Determination of ring stiffness (ISO 9969:1994) ISO 12091, Structured-wall thermoplastics pipes  Oven test ISO 13967, Thermoplastics fittings  Determination of ring stiffness 3 Terms, Definitions, symbols and abbreviations 3.1 Definitions For the purposes of this document, the terms and definitions given in EN 13476-1:2007 apply. 3.2 Symbols A length of engagement, or maximum pull-out whilst maintaining tightness C length of the sealing zone de outside diameter dem mean outside diameter dim mean inside diameter dn nominal diameter SIST EN 13476-3:2007+A1:2009



EN 13476-3:2007+A1:2009 (E) 10 dsm,min minimum mean inside diameter of socket e wall thickness (at any point) ec construction height emin minimum wall thickness of pipe or spigot e2 wall thickness at any point of the cylindrical part of a socket e3 wall thickness at any point of a sealing ring groove of a socket e4 wall thickness of the inside layer (waterway wall thickness) e5 wall thickness of the inside layer under a hollow section F distance from the end of a spigot to the effective sealing point l effective length of a pipe L1,min minimum length of a spigot
Sso actual stiffness of the cylindrical part of the socket Ssp actual stiffness of the spigot IMP 23C impact resistance determined at +23 °C 7 impact resistance determined at −10 °C 3.3 Abbreviations CaCO3 calcium carbonate CT close tolerance DN nominal size DN/ID nominal size related to inside diameter DN/OD nominal size related to outside diameter H50 value for impact resistance of a pipe MgCO3 magnesium carbonate MFR melt mass-flow rate Mg3Si4O10(OH)2 magnesiumsilicate, talcum OIT oxidation induction time PE polyethylene SIST EN 13476-3:2007+A1:2009



EN 13476-3:2007+A1:2009 (E) 11 PP polypropylene PP-MD mineral modified PP
PVC-U unplasticized poly(vinyl chloride) RF ring flexibility performance S pipe series S SDR standard dimension ratio SN nominal ring stiffness TIR true impact rate TPE thermoplastic elastomer VST Vicat softening temperature 4 Material 4.1 General The material
...