23.040.05 - Pipeline and its parts for external sewage systems
ICS 23.040.05 Details
Pipeline and its parts for external sewage systems
Cevovodi za zunanje sisteme za odpadno vodo in njihovi deli
General Information
This document specifies general requirements to be respected in product standards for components such as pipes, fittings, inspection chambers and manholes with their respective joints intended for use in drains and sewers inside and outside buildings which operate as gravity systems allowing for a maximum pressure of 40 kPa.
It also specifies general requirements for components used in hydraulically and pneumatically pressurized discharge pipes, drains and sewers.
NOTE 1 Where the term "inside buildings" is used in the context of components fixed inside buildings, it also includes discharge pipes and fittings fixed on external surfaces of buildings
NOTE 2 This document is not a product standard and therefore not intended for the direct evaluation of products.
This document covers components to be used in conveying in a satisfactory manner:
- domestic wastewater;
- rainwater and surface water; and
- other waste waters acceptable for discharge into the system (e.g. industrial wastewater).
This document applies to components of circular and other cross sections.
This document applies equally to components which are factory-made and to those constructed on site, where applicable.
NOTE 3 This document does not apply to components used for trenchless construction according to EN 14457 and for components used for renovation of drains and sewers according to EN 13380.
This document does not supersede the functional requirements of a complete system as defined in EN 752.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
- Draft30 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical Specification gives guidance for the assessment of conformity of compounds/formulations, products and assemblies in accordance with Parts 1 and 2 of EN 13598 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures.
NOTE In order to help the reader, a basic test matrix is given in Annexes A and B.
In conjunction with EN 13598- 1 and -2, this Technical Specification is applicable to ancillary underground drainage fittings including manholes and inspection chambers:
- for non-pressure underground drainage and sewerage outside the building structure (application area code "U"), reflected in the marking of products by "U", and
- for non-pressure underground drainage and sewerage for both buried in ground within the building structure (application area code "D") and outside the building structure (application area code "U"), reflected in the marking of products by "UD".
- Technical specification43 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the properties of piping system components made from glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester resin (UP). It is suited for all types of water supply, drainage and sewerage with or without pressure. Types of water supply include, but are not limited to, raw water, irrigation, cooling water, potable water, salt water, sea water, penstocks in power plants, processing plants and other water-based applications. This document is applicable to GRP UP piping systems, with flexible or rigid joints with or without end thrust load-bearing capability, primarily intended for use in direct buried installations.
- Standard69 pagesEnglish languagesale 10% offe-Library read for1 day
- Draft66 pagesEnglish languagesale 10% offe-Library read for1 day
2021-02-11 - TC decision is missing to skip FV.
- Amendment12 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment8 pagesEnglish languagesale 10% offe-Library read for1 day
This document gives the recommended practise for underground open trench installation and commissioning of thermoplastics piping systems to be used for the conveyance of water under pressure (in addition to EN 805) and for the discharge of wastewater under gravity (in addition to EN 1610) .
In the field of non-pressure underground drainage and sewerage this is reflected in the marking of products by application code "U" and "UD":
- outside the building structure (U);
- both buried in ground within the building structure (application area code "D") and outside the
building (application area code "UD").
This document covers also installation and/or connections to valves, manholes, inspection chambers, gullies and other ancillary components in piping systems.
NOTE 1 Code of practise for pipelines for gas supply is covered by EN 12007-series [21].
NOTE 2 Recommended practices for installation of plastic piping systems for soil and waste discharge within the building structure is covered by CEN/TR 13801 [12].
NOTE 3 Practices for underground installation of rainwater infiltration and storage attenuation systems are covered by CEN/TR 17179 [13].
NOTE 4 It is assumed that additional recommendations and/or requirements are detailed in the individual product standards.
NOTE 5 If non-plastic components are part of the plastic system the manufacturer's instructions should be taken into account.
Requirements and instructions concerning commissioning of systems can be found in EN 805 and EN 1610 and the relevant national and/or local regulations. This document gives specific additional recommendations for commissioning relevant for plastic piping systems.
Attention is drawn to any relevant local and/or national regulations (e.g. health, safety and hygienic requirements).
- Technical specification31 pagesEnglish languagesale 10% offe-Library read for1 day
- Technical specification31 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN 13476, together with EN 13476-1, specifies the definitions and requirements for pipes, fittings and the system based on unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) structured-wall piping systems that are intended to be used for non-pressure underground drainage and sewerage systems.
This part is applicable to pipes and fittings with smooth internal and external surfaces, designated as Type A.
It specifies test methods and test parameters as well as requirements.
This part is applicable to:
a) structured-wall pipes and fittings, which are intended to be used buried underground outside the building structure; reflected in the marking of products by "U";
b) structured-wall pipes and fittings, which are intended to be used buried underground both outside (application area code "U") and within the building structure (application area code "D"); reflected in the marking of products by "UD".
This part is applicable to structured-wall pipes and fittings with or without an integral socket with elastomeric ring seal joints as well as welded and fused joints.
This part covers a range of pipe and fitting sizes, materials, pipe constructions, stiffness classes, application classes, and tolerance classes and gives recommendations concerning colours.
NOTE It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
- Standard53 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN 13476, together with EN 13476-1, specifies the definitions and requirements for pipes, fittings and the system based on unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) structured-wall piping systems that are intended to be used for non-pressure underground drainage and sewerage systems.
This part is applicable to pipes and fittings with smooth internal and profiled external surfaces, designated as Type B.
It specifies test methods and test parameters as well as requirements.
This part is applicable to:
a) structured-wall pipes and fittings, which are intended to be used buried underground outside the building structure, reflected in the marking of products by "U";
b) structured-wall pipes and fittings, which are intended to be used buried underground both outside (application area code "U") and within the building structure (application area code "D"), reflected in the marking of products by "UD".
This part is applicable to structured-wall pipes and fittings with or without an integral socket with elastomeric ring seal joints as well as welded and fused joints.
This part covers a range of pipe and fitting sizes, materials, pipe constructions, stiffness classes, application classes, and tolerance classes and gives recommendations concerning colours.
NOTE It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
- Standard53 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the definitions and requirements for ancillary fittings and shallow chambers installed underground in non-pressure drainage and sewerage systems and manufactured from unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP), polypropylene with mineral modifier (PP-MD) or polyethylene (PE) intended for use for:
- non-pressure underground drainage and sewerage outside the building structure (application area code "U"), and
- non-pressure underground drainage and sewerage for both buried in ground within the building structure (application area code "D") and outside the building structure.
This is reflected in the marking of products by "U" and "UD".
It also covers the jointing of the ancillary fittings and shallow chambers to the pipework system.
The ancillary fittings covered by this standard are the following:
- sealed access fittings;
- rodding point covers;
- rodding tees;
- mechanical saddles.
Ancillary fittings according to this document are intended for use in pedestrian or vehicular traffic areas.
Ancillary fittings can be installed to a maximum depth of 6,0 m from ground level, with the exception of rodding point covers.
Shallow chambers according to this document are intended for use in private drains located in pedestrian areas above the ground water table, to a maximum depth of 2,0 m from ground level to the invert of the main channel. This document covers shallow chambers with flow profile bases, and their joints to the piping system.
NOTE 1 EN 124-series [1] and EN 1253-4 [2] covers may be used for shallow chambers.
NOTE 2 Manholes and inspection chambers are specified in EN 13598-2.
Ancillary fittings and shallow chambers complying with EN13598-1 comply with the general requirements given in EN 476.
Ancillary fittings and shallow chambers can be manufactured by various methods e.g. injection moulding, rotational moulding, spiral winding or fabricated from components made to other standards.
NOTE 3 Product complying with this document may be used with pipes, fittings and other components conforming to any of the plastics products standards listed in Clause 2, provided their dimension comply with the requirements for joint dimensions given in Clause 7 and to the requirements of Table 6.
NOTE 4 Products complying with this document can be installed in underground applications without additional static calculation.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the definitions and requirements for unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) manholes and inspection chambers intended for non-pressure underground drainage and sewerage systems to a maximum depth of 6 m from ground level to the invert of the manhole or inspection chamber.
This document covers manholes and inspection chambers with flow profile bases, and their joints to the piping system.
Manholes and inspection chambers are intended to be used in pedestrian or vehicular traffic areas outside the building structure.
NOTE 1 The intended use in underground installation outside the building structure is reflected in the marking of products by the application area code "U".
NOTE 2 Products complying with this document may also be used in non-traffic areas.
NOTE 3 Products complying with this standard can be installed in underground applications without additional static calculation.
NOTE 4 Shallow chambers are specified in EN 13598-1.
Manholes and inspection chambers complying with EN 13598-2 are made from a prescribed set of components that are manufactured from unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP), polypropylene with mineral modifier (PP-MD) or polyethylene (PE) and assembled together.
NOTE 5 The complete manhole or inspection chamber assembly may also include non-plastic items (near surface or surface components for example) which are not covered by this document.
NOTE 6 Manholes and inspection chambers may be supplied with covers, frame covers and gratings complying with the relevant part of EN 124 [1].
Manholes and inspection chambers complying with EN 13598-2 comply with the general requirements given in EN 476.
Manholes and inspection chambers complying with EN 13598-2 may be used for storm-water systems.
Manhole and inspection chamber components can be manufactured by various methods e.g. extrusion, injection moulding, rotational moulding, low-pressure moulding or fabricated.
NOTE 7 Manholes and inspection chambers can be site assembled from different components, but can also be manufactured as a single unit.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
This document gives requirements and guidance for the assessment of conformity of formulations, products and assemblies in accordance with EN 1401-1 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures.
NOTE 1 The quality management system is expected to conform to or is no less stringent than the relevant requirements to EN ISO 9001 [1].
NOTE 2 If third party certification is involved, the certification body is expected be compliant with either EN ISO/IEC 17065 [2] or EN ISO/IEC 17021-series [3], as applicable.
NOTE 3 In order to help the reader, a basic test matrix is given in Annex A.
In conjunction with EN 1401-1, this document is applicable to piping systems made of unplasticized poly(vinyl chloride) (PVC-U) intended for non-pressure underground drainage and sewerage:
— buried in ground outside the building structure (application area code “U”);
— both buried in ground within the building structure and outside the building structure (application area code “UD”).
- Technical specification24 pagesEnglish languagesale 10% offe-Library read for1 day
This document gives guidance for the assessment of conformity of materials, products, joints and assemblies in accordance with the applicable part(s) of EN 13476 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE 1 The quality management system is expected to conform to or be no less stringent than the relevant requirements to EN ISO 9001 [1].
NOTE 2 If third-party certification is involved, the certification body can be accredited to EN ISO/IEC 17065 [2] or EN ISO/IEC 17021 [3], as applicable.
NOTE 3 In order to help the reader, a basic test matrix is given in Annex A.
In conjunction with EN 13476 1, EN 13476 2 and EN 13476 3 this document is applicable to Plastics piping systems for non-pressure underground drainage and sewerage — Structural-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE):
- for non-pressure underground drainage and sewerage outside the building structure (application area code “U”) reflected in the marking of products by “U”, and
- for non-pressure underground drainage and sewerage for both buried in ground within the building structure (application area code “D” and outside the building structure (application area code “U”) reflected in the marking of products by “UD”.
- Technical specification25 pagesEnglish languagesale 10% offe-Library read for1 day
- Technical specification25 pagesEnglish languagesale 10% offe-Library read for1 day
This document gives guidance for the assessment of conformity of materials, products, joints and assemblies in accordance with the applicable part(s) of EN 1852 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE 1 The quality management system is expected to conform to or be no less stringent than the relevant requirements in EN ISO 9001 [1].
NOTE 2 If third-party certification is involved, the certification body is expected be accredited to EN ISO/IEC 17065 [2] or EN ISO/IEC 17021 [3], as applicable.
NOTE 3 In order to help the reader, a basic test matrix is given in Annex A.
In conjunction with EN 1852-1 this document is applicable to solid wall piping systems made of polypropylene (PP) intended to be used for:
- non-pressure underground drainage and sewerage outside the building structure (application area code “U”), and
- non-pressure underground drainage and sewerage for both buried in ground within the building structure (application area code “D”) and outside the building structure.
This is reflected in the marking of products by “U” and “UD”.
- Technical specification21 pagesEnglish languagesale 10% offe-Library read for1 day
- Technical specification21 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements for solid wall pipes with smooth internal and external surfaces, extruded from the same formulation throughout the wall, fittings and the system of unplasticized poly(vinyl chloride) (PVC U) piping systems in the field of non-pressure underground drainage and sewerage:
- buried in ground outside the building structure (application area code "U"), and
- both buried in ground, within the building structure (application area code "D") and outside the building.
This is reflected in the marking of products by "U" and "UD".
It also specifies the test parameters for the test methods referred to in this document.
NOTE 1 Solid wall multilayer pipes with different formulations throughout the wall and foamed core pipes are covered by EN 13476-2 [1] (see also CEN ISO/TR 27165 [2]).
This document covers a range of nominal sizes, a range of pipes and fittings series and a range of stiffness classes and gives recommendations concerning colours.
NOTE 2 It is the responsibility of the purchaser or specifier to make the appropriate selection from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
In conjunction with prCEN/TS 1401-2 [3], it is applicable to PVC U pipes and fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for buried piping systems for non-pressure underground drainage and sewerage.
NOTE 3 Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex C can be used with pipes and fittings conforming to this document, provided they conform to the requirements for joint dimensions given in Clause 7 and to the requirements of Table 15.
- Standard41 pagesEnglish languagesale 10% offe-Library read for1 day
This document, in conjunction with ISO 11296-1, specifies requirements and test methods for pipes
which are formed on site by spirally winding and jointing a pre-manufactured profiled plastics strip,
or a profiled plastics strip and integral locking joiner strip, and used for the renovation of underground
non-pressure drainage and sewerage networks.
It applies to spirally-wound pipes of fixed or variable diameter made of profiled plastics strips, with or
without steel stiffening elements, and installed by one of two methods.
The first method employs a dedicated winding machine in front of the open end of an existing pipeline,
e.g. in a manhole. The pipes thus formed are simultaneously inserted into the existing pipeline by the
winding forces, and by certain techniques can also be expanded in diameter after or during insertion.
The second method employs a dedicated winding machine which forms the pipe as it traverses the
existing pipeline from one manhole to the next.
It applies to profiled plastics strips of unplasticized poly(vinyl chloride) (PVC U) with integral locking
mechanism, or of high density polyethylene (HDPE) with integrally welded joints.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
This document, in conjunction with ISO 11296-1, specifies requirements and test methods for close-fit
lining systems used for the renovation of underground non-pressure drainage and sewerage networks.
It applies to pipes and fittings made of polyethylene (PE) or unplasticized poly(vinyl chloride) (PVC‑U)
as manufactured, as well to the installed lining system with its associated joints.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
This document, in conjunction with ISO 11297-1, specifies requirements and test methods for close-fit
lining systems intended to be used for the renovation of underground drainage and sewerage networks
under pressure.
It applies to pipes and fittings, as manufactured, as well as to the installed lining system. It is applicable
to polyethylene (PE) pipes of either solid wall single layer or co-extruded layer construction, which is
reduced in the factory or on site to provide a close-fitting independent or interactive pressure pipe liner,
as well as associated fittings and joints for the construction of the lining system. It is not applicable to
PE coated pipes having a peelable, contiguous, thermoplastic additional layer on the outside of the pipe.
It is applicable to PE pipes, fittings and assemblies intended to be used at an operating temperature of
20 °C as the reference temperature.
NOTE For applications operating at constant temperatures greater than 20 °C and up to 40 °C, see
ISO 4427-1:2007, Annex A.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements and test methods for plastics piping systems intended to be
used for the renovation of underground drainage and sewerage networks under pressure, including
both hydraulically and pneumatically pressurized systems. It is applicable to pipes and fittings, as
manufactured, as well as to the installed lining system. It is not applicable to the existing pipeline or
any non-structural sprayed coatings or annular filler.
This document gives the general requirements common to all relevant renovation techniques.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard, together with EN 13476 2 and EN 13476 3, specifies the definitions and general requirements for pipes, fittings and the system based on unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) structured-wall piping systems that are to be used for non-pressure underground drainage and sewerage systems.
This standard is applicable to:
a) structured-wall pipes and fittings, which are to be used buried in the ground outside a building structure only; reflected by the marking of products by “U”;
b) structured-wall pipes and fittings, which are to be used buried in ground both outside (application area code “U”) and within a building structure (application area code “D”); reflected in the marking of products by “UD”.
In conjunction with EN 13476 2 and EN 13476 3, it is applicable to structured-wall pipes and fittings with or without an integral socket with elastomeric ring seal joints, as well as welded and fused joints.
This part specifies general aspects and gives guidance concerning a national selection of requirement levels and classes where part 2 and part 3 of this standard provide options.
EN 13476 2 and EN 13476 3 specify material characteristics, dimensions and tolerances, test methods, test parameters and requirements for pipes with smooth internal and external surfaces, Type A, and pipes with smooth internal and profiled external surfaces, Type B.
This standard, together with EN 13476 2 and EN 13476 3, covers a range of pipe and fitting sizes, materials, pipe constructions, stiffness classes and tolerance classes and offers recommendations concerning colours.
NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
NOTE 2 Pipes, fittings and other components conforming to any plastic product standards referred to in Clause 2 can be used with pipes and fittings conforming to this standard, when they conform to the requirements for joint dimensions given in part 2 and part 3 of this standard and to the performance requirements given in Clause 9.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements and test methods for plastics piping systems intended to
be used for the renovation of underground non-pressure drainage and sewerage networks, which are
operated as gravity systems and subjected to a maximum surcharge pressure of 0,5 bar1). It is applicable
to pipes and fittings, as manufactured, as well as to the installed lining system. It is not applicable to the
existing pipeline or any non-structural sprayed coatings or annular filler.
This document gives the general requirements common to all relevant renovation techniques.
- Standard24 pagesEnglish languagesale 10% offe-Library read for1 day
This Part 2 of EN 13566, read in conjunction with Part 1, specifies requirements and test methods for pipes and fittings which are part of plastics piping systems installed as continuous pipes in the renovation of non-pressure drainage and sewerage networks. It covers;
- homogeneous-wall (HW) pipes made of polyethylene (PE) or polypropylene (PP),
- structured-wall (SW) pipes of the corrugated double-wall type of construction as defined in Annex B, whose structural layer(s) is (are) made of PE or PP,
- jointing of pipe lengths by means of butt fusion (HW) ) or electrofusion (SW),
- fabricated and injection-moulded fittings made of PE, PP and poly(vinyl chloride) (PVC-U).
NOTE The grouting procedure is outside the scope of this standard.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This document, in conjunction with ISO 11296-1, specifies requirements and test methods for cured-inplace
pipes and fittings used for the renovation of underground non-pressure drainage and sewerage
networks with service temperatures up to 50 °C.
It applies to the use of various thermosetting resin systems, in combination with compatible fibrous
carrier materials, reinforcement, and other process-related plastics components (see 5.3).
- Standard50 pagesEnglish languagesale 10% offe-Library read for1 day
This International Standard, in conjunction with ISO 11297-1, specifies requirements and test methods for cured-in-place pipes and fittings used for the renovation of underground drainage and sewerage networks under pressure.
It applies to the use of various thermosetting resin systems, in combination with compatible fibrous carrier materials and other process-related plastics components.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This International Standard, read in conjunction with Part 1, specifies requirements and test methods for pipes
and fittings which are part of plastics piping systems installed as continuous pipes in the renovation of
underground drainage and sewerage networks under pressure. It is applicable to PE pipes of three different
types:
- PE solid wall single layered pipes (nominal outside diameter, dn ), including any identification stripes;
- PE pipes with co-extruded layers on either or both the outside and inside of the pipe (total outside
diameter, dn), as specified in Annex A, where all layers have the same MRS rating;
- PE coated pipes (outside diameter, dn) having a peelable, contiguous, thermoplastics additional layer on
the outside of the pipe (“coated pipe”), see Annex A.
In addition it covers:
- jointing of pipe lengths by means of butt fusion;
- fabricated and injection-moulded fittings made of PE;
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical Report is applicable to the installation of rainwater infiltration and storage/attenuation systems under gravity.
This Technical Report covers installations including:
- reservoirs made by assembled cuboid shaped thermoplastic boxes;
- integral components;
- ancillary components (e.g. access provisions and connections);
- geotextiles and/or geomembranes;
- embedment and backfill.
These systems are intended for underground use in landscape, pedestrian or vehicular traffic areas and are used outside building structures.
This Technical Report is only applicable to systems containing boxes to create a reservoir where the manufacturer has clearly stated in the installation instructions how the components should be assembled.
This Technical Report is a guidance document. It provides a set of general guidelines which gives best practice for installation.
NOTE 1 It is anticipated that additional recommendations and/or requirements (e.g. design, dimensioning and structural aspects) will be detailed in the relevant standards.
NOTE 2 Attention is drawn to the need to comply with national or local regulations.
- Technical report20 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 11296-2:2018, in conjunction with ISO 11296-1, specifies requirements and test methods for pipes and fittings which are part of plastics piping systems installed as continuous pipes in the renovation of underground non-pressure drainage and sewerage networks. It is applicable to polyethylene (PE) pipes of three different types:
- PE solid wall single layered pipes (nominal outside diameter, dn), including any identification stripes;
- PE pipes with co-extruded layers on either or both the outside and inside of the pipe (total outside diameter, dn), as specified in Annex A, where all layers have the same MRS rating;
- PE coated pipes (outside diameter, dn) having a peelable, contiguous, thermoplastics additional layer on the outside of the pipe ("coated pipe"), see Annex A.
In addition, ISO 11296-2:2018 covers:
- jointing of pipe lengths by means of butt fusion;
- fabricated and injection-moulded fittings made of PE.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 11297-2:2018, in conjunction with ISO 11297‑1, specifies requirements and test methods for pipes and fittings which are part of plastics piping systems installed as continuous pipes in the renovation of underground drainage and sewerage networks under pressure. It is applicable to polyethylene (PE) pipes of three different types:
- PE solid wall single layered pipes (nominal outside diameter, dn), including any identification stripes;
- PE pipes with co-extruded layers on either or both the outside and inside of the pipe (total outside diameter, dn), as specified in Annex A, where all layers have the same MRS rating;
- PE coated pipes (outside diameter, dn) having a peelable, contiguous, thermoplastics additional layer on the outside of the pipe ("coated pipe"), see Annex A.
In addition, ISO 11297-2:2018 covers:
- jointing of pipe lengths by means of butt fusion;
- fabricated and injection-moulded fittings made of PE.
ISO 11297-2:2018 is applicable to PE pipes, fittings and assemblies intended to be used at an operating temperature of 20 °C as the reference temperature.
NOTE For applications operating at constant temperatures greater than 20 °C and up to 40 °C, see ISO 4427‑1:2007, Annex A.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN 1852 specifies the requirements for solid wall pipes, fittings and the system of polypropylene (PP) piping systems intended for use for:
non-pressure underground drainage and sewerage outside the building structure (application area code "U"), and
non-pressure underground drainage and sewerage for both buried in ground within the building structure (application area code "D") and outside the building structure.
This is reflected in the marking of products by "U" and "UD".
This standard covers PP materials without mineral modifiers.
It also specifies the test parameters for the test methods referred to in this standard.
This standard covers a range of nominal sizes, and pipe series and gives recommendations concerning colours.
NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selection from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
In conjunction with Part 2 of EN 1852, it is applicable to PP pipes and fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for buried piping systems for non-pressure underground drainage and sewerage.
This standard is applicable to PP pipes and fittings with or without an integral socket.
The fittings can be manufactured by injection-moulding or be fabricated from pipes and/or mouldings.
Requirements and limiting values for application area code "D" are given in Table 4, Table 7 and Table 14.
NOTE 2 Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex C can be connected to pipes and fittings conforming to this standard, when they conform to the requirements for joint dimensions given in Clause 6 and to the requirements of Table 14.
- Standard40 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical Report is applicable to the installation of rainwater infiltration and storage/attenuation systems under gravity.
This Technical Report covers installations including:
- reservoirs made by assembled cuboid shaped thermoplastic boxes;
- integral components;
- ancillary components (e.g. access provisions and connections);
- geotextiles and/or geomembranes;
- embedment and backfill.
These systems are intended for underground use in landscape, pedestrian or vehicular traffic areas and are used outside building structures.
This Technical Report is only applicable to systems containing boxes to create a reservoir where the manufacturer has clearly stated in the installation instructions how the components should be assembled.
This Technical Report is a guidance document. It provides a set of general guidelines which gives best practice for installation.
NOTE 1 It is anticipated that additional recommendations and/or requirements (e.g. design, dimensioning and structural aspects) will be detailed in the relevant standards.
NOTE 2 Attention is drawn to the need to comply with national or local regulations.
- Technical report20 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN 1852 specifies the requirements for solid wall pipes with smooth internal and external surfaces extruded from the same compound/formulation throughout the wall, fittings and the system of polypropylene (PP) piping systems intended for use for:
- non-pressure underground drainage and sewerage outside the building structure (application area code "U"), and
- non-pressure underground drainage and sewerage for both buried in ground within the building structure (application area code "D") and outside the building structure.
This is reflected in the marking of products by "U" and "UD".
This standard covers PP materials without mineral modifiers.
It also specifies the test parameters for the test methods referred to in this standard.
NOTE 1 Solid wall multilayer pipes with different formulation throughout the wall and foamed core pipes are covered by EN 13476-2 [1] (see also CEN ISO/TR 27165 [2]).
This standard covers a range of nominal sizes, and pipe series and gives recommendations concerning colours.
NOTE 2 It is the responsibility of the purchaser or specifier to make the appropriate selection from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
In conjunction with CEN/TS 1852-2, it is applicable to PP pipes and fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for buried piping systems for non-pressure underground drainage and sewerage.
The fittings can be manufactured by injection-moulding or be fabricated from pipes and/or mouldings.
NOTE 3 Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex C can be connected to pipes and fittings conforming to this standard, when they conform to the requirements for joint dimensions given in Clause 6 and to the requirements of Table 14.
- Standard40 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment7 pagesEnglish languagesale 10% offe-Library read for1 day
Corrigendum issued due to mistake from TC in Table B.1 and in Clause 2 (SV on 2017-06-02)
- Corrigendum2 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the objectives for drain and sewer systems outside buildings. It specifies the functional requirements for achieving these objectives and the principles for strategic and policy activities relating to planning, design, installation, operation, maintenance and rehabilitation.
It is applicable to drain and sewer systems from the point where wastewater leaves a building, roof drainage system, or paved area, to the point where it is discharged into a wastewater treatment plant or receiving water body.
Drains and sewers below buildings are included provided that they do not form part of the drainage system for the building.
- Standard90 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN 12200 gives guidance for the assessment of conformity of formulations, products, joints and assemblies in accordance with EN 12200 1:2016 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of third-party certification procedures.
NOTE In order to help the reader, a basic test matrix is given in Annex A.
In conjunction with EN 12200 1:2016, this document is applicable to piping systems made of unplasticized poly(vinyl chloride) (PVC-U) intended to be used for above ground external rainwater, and to fittings and brackets made of acrylic materials which may be used in combination with the pipes.
- Technical specification21 pagesEnglish languagesale 10% offe-Library read for1 day
- Technical specification20 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN 1453 specifies the requirements for structured-wall unplasticized poly(vinyl chloride) (PVC U) pipes and the system intended to be used for soil and waste discharge applications (low and high temperature) inside buildings (application area code "B")
NOTE 1 The intended use is reflected in the marking of products by "B".
This part of EN 1453 is also applicable to structured-wall unplasticized poly(vinyl chloride) (PVC U) pipes, and the system intended for the following purposes:
ventilating part of the pipework in association with discharge applications;
rainwater pipework inside building.
It also specifies the test parameters for the test methods referred to in this standard.
NOTE 2 Single layer foamed PVC U pipes and spirally-formed PVC U pipes are not covered by this standard.
This standard covers a range of nominal sizes and gives recommendations concerning colours.
NOTE 3 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
For external above ground application additional requirements depending on the climatic conditions should be agreed between the manufacturer and the user.
NOTE 4 Pipes conforming to this standard are normally associated with fittings conforming to EN 1329 1. Pipes, fittings and components conforming to any of the product standards listed in Annex C can also be used with pipes conforming to this standard, provided they conform to the requirements for joint dimensions given in Clause 6 and to the requirements in Table 11.
NOTE 5 Joints and adhesives are considered to be part of the system as covered in the scope.
NOTE 6 Products conforming to this standard may be submitted to national requirements on fire regulation.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical specification gives guidance for the assessment of conformity of materials, products, joints and assemblies in accordance with the applicable part(s) of EN 14758 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
In conjunction with EN 14758-1) this document is applicable to solid wall piping systems made of polypropylene modified with mineral(s) (PP-MD) intended to be used for:
- non-pressure underground drainage and sewerage outside the building structure (application area code "U"), and
- non-pressure underground drainage and sewerage for both buried in ground within the building structure (application area code "D") and outside the building structure.
This is reflected in the marking of products by "U" and "UD".
- Technical specification19 pagesEnglish languagesale 10% offe-Library read for1 day
- Technical specification21 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical Specification gives guidance for the assessment of conformity of materials, products, joints and assemblies in accordance with the applicable part(s) of EN 14758 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE In order to help the reader, a basic test matrix is given in Annex A.
In conjunction with EN 14758 1 this document is applicable to solid wall piping systems made of polypropylene modified with mineral(s) (PP-MD) intended to be used for:
— non-pressure underground drainage and sewerage outside the building structure (application area code “U”); and
— non-pressure underground drainage and sewerage for both buried in ground within the building structure (application area code “D”) and outside the building structure.
This is reflected in the marking of products by “U” and “UD”.
- Technical specification19 pagesEnglish languagesale 10% offe-Library read for1 day
- Technical specification21 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for pipes, fittings, brackets and the system of unplasticized poly(vinyl chloride) (PVC-U) intended for use as above-ground external rainwater piping systems.
It also specifies:
a) The requirements for metallic brackets.
b) Both solid wall pipes and fittings, (i.e. product manufactured from a single layer), as well as solid wall multi-layer pipes.
c) The test parameters for the test methods referred to in this standard.
Pipes can be used in conjunction with fittings and brackets of acrylic materials provided these polymers meet the performance requirements of this standard.
The products are usually used in conjunction with gutters conforming to EN 607 [1]. They are not intended for use with products conforming to EN 612 [2].
This standard is applicable to PVC-U rainwater systems of circular, square, rectangular or any other shape with sealed (rubber ring or solvent cement) or unsealed joints.
This standard covers a range of pipes and fittings sizes.
NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selections from the size range to take into account their particular requirements and any relevant national regulations and installation practices or codes.
NOTE 2 The term "rainwater" in this standard is used also to encompass "surface water" (as defined in EN 752 [6]) run-off from buildings.
- Standard34 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is applicable to the construction and testing of drains and sewers normally buried in the ground and usually operating under gravity. The construction of pipelines operating under pressure is covered by this European Standard together with EN 805 as appropriate. This European Standard is applicable to drains and sewers installed in trenches, under embankments or above ground. For trenchless construction EN 12889 applies. Additionally other local regulation should be taken into account e.g. concerning health and safety pavement reinstatement and requirements for tightness testing.
This standard does not apply for planning and design in accordance with EN 752.
- Standard38 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies performance requirements and describes test methods for pipes and fittings for the renovation of underground drain and sewer systems by lining with a single rigid annulus of structural cementitious grout formed behind a plastics inner layer. This plastics layer serves as permanent formwork anchored to the grout. It is applicable to plastics inner layers and grout systems with or without steel reinforcement.
This European Standard does not apply to the structural design of the lining system.
NOTE Systems with multiple annuli are available, but these are controlled by patent rights and not covered by this European Standard.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to pipes and fittings of longitudinally welded stainless steel pipes with spigot and socket for waste water systems and specifies dimensions and tolerances for pipes, fittings and pipe connectors and establishes a system of designations for the different pipe and fitting types that conform to the stated requirements.
This part of EN 1124 is only valid in connection with EN 1124 1.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN 12201 gives guidance for the assessment of conformity of compounds, products, joints and assemblies in accordance with the applicable part(s) of EN 12201 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures. It is recommended that the quality management system conforms to or is no less stringent than the relevant requirements to EN ISO 9001 [1]. NOTE 1 If certification is involved, the certification and inspection body is preferably compliant with EN ISO/IEC 17065 [5], EN ISO/IEC 17021 [3] or EN ISO/IEC 17020 [2], as applicable. In conjunction with Parts 1 to 5 of EN 12201 (see Foreword) this document is applicable to polyethylene (PE) plastics piping systems for water supply, and for drainage and sewerage under pressure. It is applicable to PE pipes, fittings, and valves, their joints and to joints with components of other materials intended to be used under the following conditions:
a) allowable operating pressure, PFA, up to 25 bar1);
b) an operating temperature of 20 °C as a reference temperature;
c) buried in the ground;
d) sea outfalls;
e) laid in water;
f) above ground, including pipes suspended below bridges.
NOTE 2 For applications operating at constant temperature greater than 20 °C and up to 40 °C, see EN 12201-1:2011, Annex A. NOTE 3 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.
- Technical specification40 pagesEnglish languagesale 10% offe-Library read for1 day
Dieser Teil der EN 12201 enthält Empfehlungen für die Beurteilung der Konformität von Formmassen, Erzeugnissen, Verbindungen und Bauteilkombinationen entsprechend dem/den zutreffenden Teil(en) der EN 12201, die als Teil des Qualitätsmanagementsystems im Qualitätssicherungsplan des Herstellers und für die Einführung von Zertifizierungsverfahren vorgesehen sind.
Es wird empfohlen, dass das Qualitätsmanagementsystem EN ISO 9001 [1] oder mindestens ebenso strengen Anforderungen entspricht.
ANMERKUNG 1 Bei Zertifizierung wird empfohlen, dass die Zertifizierungs- und die Überwachungsstelle in Abhängigkeit vom Anwendungsfall vorzugsweise EN ISO/IEC 17065 [5], EN ISO/IEC 17021 [3] oder EN ISO/IEC 17020 [2] entsprechen.
Dieses Dokument gilt in Zusammenhang mit den Teilen 1 bis 5 der EN 12201 (siehe Vorwort) für Kunststoff-Rohrleitungssysteme aus Polyethylen (PE) für die Wasserversorgung sowie für Entwässerungs- und Abwasserdruckleitungen. Es gilt für Rohre, Formstücke und Armaturen aus PE, deren Verbindungen sowie für Verbindungen mit Rohrleitungsteilen aus anderen Werkstoffen, die für die Verwendung unter den folgenden Bedingungen vorgesehen sind:
a) zulässiger Betriebsdruck PFA bis 25 bar1);
b) Betriebstemperatur von 20 °C als Bezugstemperatur;
c) erdverlegt;
d) Entwässerung ins Meer (Siele);
e) in Gewässern verlegt;
f) oberirdisch verlegt, einschließlich Düker und Brückenleitungen.
ANMERKUNG 2 Zu Anwendungen bei konstanter Betriebstemperatur oberhalb 20 °C bis 40 °C siehe EN 12201-1:2011, Anhang A.
ANMERKUNG 3 Die geeignete Auswahl aus diesen Aspekten unter Berücksichtigung der jeweiligen Anforderungen und aller nationalen Leitlinien oder Regelungen sowie Verfahren oder Vorschriften für die Verlegung liegt in der Verantwortung des Käufers oder Auftraggebers.
- Technical specification40 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN ISO 1452 gives guidance for the assessment of conformity of compounds/formulations, products, joints and assemblies in accordance with the applicable parts of EN ISO 1452 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures. NOTE 1 It is recommended that the quality management system conforms to or is no less stringent than the relevant requirements to EN ISO 9001 [1]. NOTE 2 If certification is involved, the certification body and inspection body is preferably compliant with EN ISO/IEC 17065 [5] or EN ISO/IEC 17021 [3], as applicable.
In conjunction with Parts 1 to 5 of EN ISO 1452 (see Foreword) this document is applicable to unplasticized poly(vinyl chloride) (PVC-U) plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure.
- Technical specification26 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN ISO 1452 gives guidance for the assessment of conformity of compounds/formulations, products, joints and assemblies in accordance with the applicable parts of EN ISO 1452 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
It is recommended that the quality management system conforms to or is no less stringent than the relevant requirements to EN ISO 9001 [1].
NOTE If certification is involved, the certification body and inspection body is preferably compliant with EN 45011 [2], EN 45012 [3] or EN ISO/IEC 17021 [4], as applicable.
In conjunction with Parts 1 to 5 of EN ISO 1452 (see Foreword) this document is applicable to unplasticized poly(vinyl chloride) (PVC-U) plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure.
- Technical specification26 pagesEnglish languagesale 10% offe-Library read for1 day
CEN/TS 14578 specifies recommended practices for the underground installation of piping systems made of glass-reinforced thermosetting plastics based on unsaturated polyester resin (GRP-UP), intended to be used for pressure or non-pressure water or sewerage applications and complying with, as applicable, EN 14364 and/or EN 1796. It is applicable to GRP-UP piping systems of nominal sizes from DN 100 to DN 4000 which are intended to be used for the conveyance of liquids at temperatures up to 50 °C and at pressures of 0,5 bar and greater. Design procedures, the determination of long-term safety factors based on a semi-probabilistic approach, surge allowance and allowable negative pressures for buried GRP pipe applications are addressed in CEN/TS 14807 [1]. Piping systems conforming to EN 1796 or EN 14364 can also be used for above-ground applications provided the influence of the environment and the supports is considered in the design of the pipes and joints. It is recommended to refer to ISO/TR 10986 [4] for guidelines for the installation of above-ground flexible jointed pipes.
- Technical specification8 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical Report gives guidance for the assessment of conformity of vitrified clay pipe systems for drains and sewers including pipes, fittings, manholes, perforated pipes, jacking pipes and associated products by the establishment of voluntary third-party certification procedures.
It is recommended that the quality management system conforms to or is no less stringent than the relevant requirements to EN ISO 9001.
- Technical report9 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to a) manholes, when made from glass-reinforced thermosetting plastics (GRP) based on polyester resin (UP); b) inspection chambers, when made from glass-reinforced thermosetting plastics (GRP) based on polyester resin (UP) which are intended to be used with inverts which are at a depth not exceeding 2 m. These products are intended to be used within a drain or sewer system operating without pressure or occasionally at a head of pressure up to 1 bar. It applies to products, and their joints, intended for use in buried installations and to be installed by open-trench techniques. The units have a circular shape with nominal sizes not exceeding the maximum nominal size specified in EN 14364. The intended use of these products is to provide access to, buried drain or sewer systems for the conveyance of waste water at temperatures up to 50 °C, without pressure or occasionally at a head of pressure up to 1 bar, outside buildings and installed in areas subjected to vehicle and/or pedestrian traffic. It specifies definitions including symbols, requirements and characteristics of manholes, inspection chambers, joints, materials, test methods and marking.
- Standard29 pagesEnglish languagesale 10% offe-Library read for1 day
This part of EN 12201 specifies the characteristics of pipes made from polyethylene (PE 100, PE 80 and PE 40) for buried and above ground applications, intended for the conveyance of water for human consumption, raw water prior to treatment, drainage and sewerage under pressure, vacuum sewer systems, and water for other purposes. It also specifies the test parameters for the test methods referred to in this standard. In conjunction with Part 1 and Parts 3 to 5 of EN 12201, it is applicable to PE pipes, their joints and to joints with components of PE and other materials intended to be used under the following conditions: a) allowable operating pressure, PFA, up to 25 bar; b) an operating temperature of 20 °C as a reference temperature; c) buried in the ground; d) sea outfalls; e) laid in water; f) above ground, including pipes suspended below bridges. EN 12201 covers a range of allowable operating pressures and gives requirements concerning colours and additives. It covers three types of pipe: - PE pipes (outside diameter dn) including any identification stripes; - PE pipes with co-extruded layers on either or both the outside and/or inside of the pipe (total outside diameter dn) as specified in Annex B, where all layers have the same MRS rating; - PE pipes (outside diameter dn) with a peelable, contiguous thermoplastics additional layer on the outside of the pipe (‘coated pipe’) as specified in Annex C.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements, dimensions and tolerances for pipes and fittings of longitudinally welded, stainless steel pipe with spigot and socket used for vacuum drainage systems inside and outside buildings and for gravity and vacuum drainage systems on ships and floating maritime structures ) :
- above freeboard deck as long as the heeling is taken into account in the event of damage when installed above freeboard deck on passenger ships;
- inside a watertight compartment below freeboard deck;
- with direct connection to the outboard (not permitted below freeboard deck);
- inside tanks as long as these are not filled with foreign media and are not cargo tanks.
On well-anchored maritime structures, this European Standard applies to pipes and fittings of longitudinally welded stainless steel pipe with spigot and socket used in drainage systems in the accommodation area.
Pipes and fittings according to this European Standard may also be used in central vacuum cleaning installations, in vacuum suction lifting installations, in chip transporting installations and in other waste water and process pipes as long as the media to be discharged do not damage the components or the health and safety of the personnel.
For other pipes, this European Standard only applies if agreed with the relevant operators and following prior consultation with the manufacturer.
This European Standard contains a designation system for the different types of pipes and fittings for easy identification of each component.
This European Standard is only applicable in conjunction with EN 1124-1.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day