Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 7-1: Type MPO connector family - One fibre row

This part of IEC 61754 defines the standard interface dimensions for type MPO family of connectors with one row of fibres.

Lichtwellenleiter - Verbindungselemente und passive Bauteile - Steckgesichter von Lichtwellenleiter-Steckverbindern - Teil 7-1: Steckverbinderfamilie der Bauart MPO - Eine Faserreihe

Dispositifs d'interconnexion et composants passifs à fibres optiques - Interfaces de connecteurs pour fibres optiques - Partie 7-1: Famille de connecteurs de type MPO - Une rangée de fibres

IEC 61754-7-1:2014 définit les dimensions d’interface normales pour la famille de connecteurs de type MPO à une rangée de fibres. Cette première édition de l’IEC 61754-7-1, conjointement avec la première édition de l’IEC 61754-7-2, annule et remplace la troisième édition de l’IEC 61754-7 parue en 2008. Cette première édition de l’IEC 61754-7-1 traite des variantes MPO à une rangée de fibres, ainsi que des embases de dispositif actif et de fiches angulaires vers le haut. La première édition de l’IEC 61754-7-2 traitera des variantes MPO à deux rangées de fibres et des embases de dispositif actif et de fiches angulaires vers le haut associées. A la suite de la publication de l’IEC 61754-7-1 et de l’IEC 61754-7-2, l’IEC 61754-7 sera supprimée.

Optični spojni elementi in pasivne komponente - Vmesniki optičnih konektorjev - 7-1. del: Družina konektorjev vrste MPO - Vlakna enoredno (IEC 61754-7-1:2014)

Ta del standarda IEC 61754 določa standardne dimenzije vmesnikov za družino konektorjev vrste MPO
z enorednimi vlakni.

General Information

Status
Published
Publication Date
23-Nov-2014
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
04-Nov-2014
Due Date
09-Jan-2015
Completion Date
24-Nov-2014

Relations

Buy Standard

Standard
EN 61754-7-1:2014
English language
33 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61754-7-1:2014
01-december-2014
1DGRPHãþD
SIST EN 61754-7:2008
2SWLþQLVSRMQLHOHPHQWLLQSDVLYQHNRPSRQHQWH9PHVQLNLRSWLþQLKNRQHNWRUMHY
GHO'UXåLQDNRQHNWRUMHYYUVWH0329ODNQDHQRUHGQR ,(&
Fibre optic interconnecting devices and passive components - Fibre optic connector
interfaces - Part 7-1: Type MPO connector family - One fibre row
Ta slovenski standard je istoveten z: EN 61754-7-1:2014
ICS:
33.180.20 3RYH]RYDOQHQDSUDYH]D Fibre optic interconnecting
RSWLþQDYODNQD devices
SIST EN 61754-7-1:2014 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 61754-7-1:2014

---------------------- Page: 2 ----------------------

SIST EN 61754-7-1:2014


EUROPEAN STANDARD EN 61754-7-1

NORME EUROPÉENNE

EUROPÄISCHE NORM
October 2014
ICS 33.180.20 Supersedes EN 61754-7:2008 (partially)
English Version
Fibre optic interconnecting devices and passive components -
Fibre optic connector interfaces - Part 7-1: Type MPO connector
family - One fibre row
(IEC 61754-7-1:2014)
Dispositifs d'interconnexion et composants passifs à fibres Lichtwellenleiter - Verbindungselemente und passive
optiques - Interfaces de connecteurs pour fibres optiques - Bauteile - Steckgesichter von Lichtwellenleiter-
Partie 7-1: Famille de connecteurs de type MPO - Une Steckverbindern - Teil 7-1: Steckverbinderfamilie der Bauart
rangée de fibres MPO - Eine Faserreihe
(CEI 61754-7-1:2014) (IEC 61754-7-1:2014)
This European Standard was approved by CENELEC on 2014-10-08. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.


European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN 61754-7-1:2014 E

---------------------- Page: 3 ----------------------

SIST EN 61754-7-1:2014
EN 61754-7-1:2014 - 2 -
Foreword
The text of document 86B/3794A/FDIS, future edition 1 of IEC 61754-7-1, prepared by SC 86B "Fibre
optic interconnecting devices and passive components" of IEC/TC 86 "Fibre optics" was submitted to
the IEC-CENELEC parallel vote and approved by CENELEC as EN 61754-7-1:2014.

The following dates are fixed:
(dop) 2015-07-08
• latest date by which the document has to be
implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2017-10-08
standards conflicting with the
document have to be withdrawn

This document supersedes EN 61754-7:2008 (Partially).

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.

Endorsement notice
The text of the International Standard IEC 61754-7-1:2014 was approved by CENELEC as a
European Standard without any modification.

---------------------- Page: 4 ----------------------

SIST EN 61754-7-1:2014



IEC 61754-7-1

®


Edition 1.0 2014-09




INTERNATIONAL



STANDARD



















Fibre optic interconnecting devices and passive components – Fibre optic

connector interfaces –

Part 7-1: Type MPO connector family – One fibre row


























INTERNATIONAL

ELECTROTECHNICAL

COMMISSION

PRICE CODE
V




ICS 33.180.20 ISBN 978-2-8322-1843-3



  Warning! Make sure that you obtained this publication from an authorized distributor.


® Registered trademark of the International Electrotechnical Commission

---------------------- Page: 5 ----------------------

SIST EN 61754-7-1:2014
– 2 – IEC 61754-7-1:2014 © IEC 2014
CONTENTS
FOREWORD . 3
1 Scope . 5
2 Description . 5
3 Interfaces . 5

Figure 1 – MPO connector configurations . 6
Figure 2 – MPO female plug, down-angled interface . 7
Figure 3 – MPO female plug, up-angled interface . 7
Figure 4 – Optical datum target location diagrams . 9
Figure 5 – Gauge pin . 10
Figure 6 – Gauge for plug . 10
Figure 7 – MPO male plug, down-angled interface . 11
Figure 8 – MPO male plug, up-angled interface . 12
Figure 9 – MPO adaptor interface, opposed keyway configuration . 14
Figure 10 – MPO female plug, flat interface . 16
Figure 11 – MPO male plug, flat interface . 18
Figure 12 – MPO backplane housing interface (1 of 2) . 20
Figure 13 – MPO printed board housing interface (1 of 2) . 23
Figure 14 – MPO adaptor interface, aligned keyway configuration . 26
Figure 15 – MPO active device receptacle, angled interface. 28
Figure 16 – MPO active device receptacle, flat interface . 30

Table 1 – Dimensions of the MPO female plug, down- or up-angled interfaces . 8
Table 2 – Dimensions of the gauge pin . 10
Table 3 – Dimensions of the gauge for plug . 11
Table 4 – Dimensions of the MPO male plug, down- or up-angled interfaces . 13
Table 5 – Dimensions of the MPO adaptor interface, opposed keyway configuration . 15
Table 6 – Dimensions of the MPO female plug, flat interface . 17
Table 7 – Dimensions of the MPO male plug, flat interface . 19
Table 8 – Dimensions of the MPO backplane housing . 22
Table 9 – Grade . 23
Table 10 – Dimensions of the MPO printed board housing interface . 25
Table 11 – Dimensions of the MPO adaptor interface, aligned keyway configuration. 27
Table 12 – Dimensions of the MPO active device receptacle, angled interface . 29
Table 13 – Dimensions of the MPO active device receptacle, flat interface . 31

---------------------- Page: 6 ----------------------

SIST EN 61754-7-1:2014
IEC 61754-7-1:2014 © IEC 2014 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

FIBRE OPTIC INTERCONNECTING
DEVICES AND PASSIVE COMPONENTS –
FIBRE OPTIC CONNECTOR INTERFACES –

Part 7-1: Type MPO connector family –
One fibre row

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61754-7-1 has been prepared by subcommittee 86B: Fibre optic
interconnecting devices and passive components, of IEC technical committee 86: Fibre optics.
This first edition of IEC 61754-7-1, along with the first edition of IEC 61754-7-2, cancels and
replaces the third edition of IEC 61754-7, published in 2008.
This first edition of IEC 61754-7-1 includes the one fibre row MPO variants, including the
addition of active device receptacles and up-angled plugs.
The first edition of IEC 61754-7-2 will include the two fibre row MPO variants and related active
device receptacles and up-angled plugs.

---------------------- Page: 7 ----------------------

SIST EN 61754-7-1:2014
– 4 – IEC 61754-7-1:2014 © IEC 2014
Following the publication of both IEC 61754-7-1 and IEC 61754-7-2, IEC 61754-7 will be
withdrawn.
The text of this standard is based on the following documents:
FDIS Report on voting
86B/3794A/FDIS 86B/3826/RVD

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all the parts in the IEC 61754 series, under the general title Fibre optic interconnecting
devices and passive components – fibre optic connector interfaces, can be found on the IEC
website.
The committee has decided that the contents of this publication will remain unchanged until the
stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data related to
the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
A bilingual version of this publication may be issued at a later date.

---------------------- Page: 8 ----------------------

SIST EN 61754-7-1:2014
IEC 61754-7-1:2014 © IEC 2014 – 5 –
FIBRE OPTIC INTERCONNECTING
DEVICES AND PASSIVE COMPONENTS –
FIBRE OPTIC CONNECTOR INTERFACES –

Part 7-1: Type MPO connector family –
One fibre row



1 Scope
This part of IEC 61754 defines the standard interface dimensions for type MPO family of
connectors with one row of fibres.
2 Description
The parent connector for type MPO connector family is a multiway plug characterized by a
rectangular ferrule normally 6,4 mm × 2,5 mm which utilizes two pins of 0,7 mm diameter as its
alignment. The variant in this standard provides a joint of 2 to 12 fibres by arraying them
between two pin-positioning holes in the ferrule in a one-layer, (one-row) arrangement. The
connector includes a push-pull coupling mechanism and a ferrule spring loaded in the direction
of the optical axis. The connector has a single male key which may be used to orient and limit
the relative position between the connector and the component to which it is mated.
Connector interfaces are configured using a female plug without pins, a male plug with pins
fixed and an adaptor as shown in Figure 1. The female plug is intermateable with the male plug.
There are two angled-interface plugs, one called down-angled and the other up-angled. They
are defined for both male and female plugs. The up and down descriptors refer to the tilt
direction of the ferrule’s angled end-face relative to the fibre axis when looking toward the end-
face with the plug’s key feature on the top. For down-angled plugs, the angled surface faces
slightly downward. For up-angled plugs, the angled surface faces slightly upward. These
different angles affect intermateability for the two adaptor types. An opposed keyway adaptor
mates two plugs with the keys in opposite orientations, for example one side keyway-up and
the other keyway-down. In contrast, an aligned keyway adaptor mates two plugs with the keys
at the same orientation. When using an opposed keyway adaptor with angled interfaces, two
down-angled plugs or two up-angled plugs are connected. For aligned keyway adaptors with
angled interfaces, one down-angled plug and one up-angled plug are connected.
Moreover, connector interfaces between the female plug and the male plug are configured by
applying a backplane housing and a printed board housing instead of the adaptor.
Additionally, the female plug interface is intermateable with the active device receptacle.
3 Interfaces
This standard contains the following standard interfaces:
Interface IEC 61754-7-1-1: MPO female plug, down-angled interface for 2 to 12 fibres
Interface IEC 61754-7-1-2: MPO male plug, down-angled interface for 2 to 12 fibres
Interface IEC 61754-7-1-3: MPO adaptor interface – Opposed keyway configuration
Interface IEC 61754-7-1-4: MPO female plug, flat interface for 2 to 12 fibres

---------------------- Page: 9 ----------------------

SIST EN 61754-7-1:2014
– 6 – IEC 61754-7-1:2014 © IEC 2014
Interface IEC 61754-7-1-5: MPO male plug, flat interface for 2 to 12 fibres
Interface IEC 61754-7-1-6: MPO backplane housing interface
Interface IEC 61754-7-1-7: MPO printed board housing interface
Interface IEC 61754-7-1-8: MPO adaptor interface – Aligned keyway configuration
Interface IEC 61754-7-1-9:  MPO active device receptacle, angled interface
Interface IEC 61754-7-1-10: MPO active device receptacle, flat interface
Interface IEC 61754-7-1-11: MPO female plug, up-angled interface for 2 to 12 fibres
Interface IEC 61754-7-1-12:  MPO male plug, up-angled interface for 2 to 12 fibres
The following interfaces are intermateable:
Female plugs Adaptors/housings/ Male plugs
receptacles
61754-7-1-1 61754-7-1-3 61754-7-1-2
61754-7-1-11 61754-7-1-3 61754-7-1-12
61754-7-1-1 61754-7-1-8 61754-7-1-12
61754-7-1-11 61754-7-1-8 61754-7-1-2
61754-7-1-4 61754-7-1-3 and 61754-7-1-8 61754-7-1-5
61754-7-1-1 or 61754-7-1-11 61754-7-1-6 and 61754-7-1-7 61754-7-1-2 or 61754-7-1-12
61754-7-1-4 61754-7-1-6 and 7-1-7 61754-7-1-5
61754-7-1-1 61754-7-1-9 N/A
61754-7-1-4 61754-7-1-10 N/A
NOTE Connector interfaces with 2 to 12 fibres will intermate and will correctly align the lower defined numbers of
optical datum targets (see Figure 4)
Figure 1 shows MPO connector configurations.
IEC

Figure 1 – MPO connector configurations

---------------------- Page: 10 ----------------------

SIST EN 61754-7-1:2014
IEC 61754-7-1:2014 © IEC 2014 – 7 –
Figures 2 and 3 show down-angled and up-angled interface of the MPO female plug. Table 1
gives the dimensions of the MPO female plug, down- or up-angled interfaces.
IEC

Figure 2 – MPO female plug, down-angled interface
IEC

Figure 3 – MPO female plug, up-angled interface

---------------------- Page: 11 ----------------------

SIST EN 61754-7-1:2014
– 8 – IEC 61754-7-1:2014 © IEC 2014
Table 1 – Dimensions of the MPO female plug, down- or up-angled interfaces
Dimensions
Reference
Maximum
Minimum
a
A 0,699 mm 0,701 mm
b
C 4,597 mm 4,603 mm
D 6,3 mm 6,5 mm
h
D1 6,7 mm –
E 8,34 mm 8,54 mm
F 9,49 mm 9,59 mm
G 10,85 mm 11,05 mm
H 12,19 mm 12,59 mm
c,f
I 8,8 mm
9,2 mm
J 7,9 mm 8,1 mm
K 1,4 mm –
d,e
L 0,2 mm
0,8 mm
M 2,4 mm 2,6 mm
N 2,8 mm 3,0 mm
O 4,89 mm 4,99 mm
P 5,59 mm 5,69 mm
Q 5,7 mm –
R – 7,7 mm
S 2,9 mm 3,1 mm
T – 0,8 mm
U 2,4 mm 2,5 mm
h
U1 2,7 mm –
AA 42° 45°
AB – 45°
AC – 45°
i,j
AD 7,5° 8,5°
a
 Each pin-hole shall accept a gauge pin as shown in Figure 5 to a depth of 5,5 mm with a maximum force of 1,7 N. In
addition, two pin-holes of a plug shall accept a gauge as shown in Figure 5 to a depth of 5,5 mm with a maximum
force of 3,4 N.
b
 Dimension C is defined as the distance between two pin-hole centres.
c
 Dimension I is given for a fibre endface centre of a plug end when not mated. It is noticed that a ferrule is
movable by a certain axial compression force, and therefore dimension I is variable. Ferrule compression force
shall be 7,8 N to 11,8 N when a position of the fibre endface from the datum Z is in the range of 8,2 mm to
8,4 mm.
d
 The coupling sleeve shall be movable by a certain axial compression force. Dimension L is given for a coupling
sleeve end when not mated. Coupling sleeve compression force shall be 2,9 N to 6,9 N when the position of the
coupling sleeve endface from datum Z is in the range of 0 mm to 0,1 mm to the right or to the left of datum Z.
e
 An adaptor coupling part shall be unlocked by a left-direction movement of a coupling sleeve, when it is separate
from an adaptor. When the coupling sleeve is moved for unlocking, the position of the coupling sleeve endface
shall be larger than 2,0 mm in the left direction from the datum Z.
f
 Dimension I is defined at the centre line between the two pin-hole centres.
g
 The mating/unmating force between an MPO plug and adaptor shall not exceed 30,0 N.
h
Dimensions D1 and U1 are defined only at the end of the plug as shown.
i
The down-angled and up-angled plugs shall be clearly marked to distinguish them from each other and flat
interfaces through the use of colour, labelling or other appropriate identification method. This identification
method shall be visible wh
...

Questions, Comments and Discussion