Fibre optic interconnecting devices and passive components - Performance standard - Part 111-8: Sealed closures for category G - Ground (IEC 61753-111-8:2009)

This part of IEC 61753 contains the minimum test and measurement requirements and severities which a sealed fibre optic closure must satisfy in order to be categorised as meeting the IEC standard for category G - ground, as defined in Annex A of IEC 61753-1. Free breathing closures are not covered in this standard.

Lichtwellenleiter - Verbindungselemente und passive Bauteile - Betriebsverhalten - Teil 111-8: Druckdichte Muffen für die Kategorie G - Bodenverlegung (IEC 61753-111-8:2009)

Dispositifs d'interconnexion et composants passifs à fibres optiques norme de qualité de fonctionnement - Partie 111-8: Boîtiers scellés pour catégorie G - Au niveau du sol (CEI 61753-111-8:2009)

La CEI 61753-111-8:2009 contient les sévérités et les exigences minimales d'essai et de mesure auxquelles un boîtier à fibres optiques scellé doit satisfaire afin d'être classé comme conforme aux exigences de la norme CEI pour la catégorie G - au niveau du sol, telle qu'elle est définie à l'Annexe A de la CEI 61753-1. Les boîtiers à ventilation libre ne sont pas couverts par la présente norme.

Optični spojni elementi in pasivne komponente - Izvedbeni standard - 111-8. del: Zatesnjene spojnice za kategorijo G (Ground) - Talna uporaba (IEC 61753-111-8:2009)

Ta del IEC 61753 vsebuje minimalne zahteve za preskus in merjenje ter natančnost, ki jih mora izpolnjevati zatesnjena optična spojnica, da zadošča standardu IEC za kategorijo G (Ground) – Talna uporaba, kot je opredeljeno v Dodatku A IEC 61753-1. Ta standard ne zajema spojnic z zračenjem.

General Information

Status
Withdrawn
Publication Date
04-Mar-2010
Withdrawal Date
18-Jun-2024
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
19-Jun-2024
Due Date
12-Jul-2024
Completion Date
19-Jun-2024

Relations

Buy Standard

Standard
EN 61753-111-8:2010
English language
26 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Lichtwellenleiter - Verbindungselemente und passive Bauteile - Betriebsverhalten - Teil 111-8: Druckdichte Muffen für die Kategorie G - Bodenverlegung (IEC 61753-111-8:2009)Dispositifs d'interconnexion et composants passifs à fibres optiques norme de qualité de fonctionnement - Partie 111-8: Boîtiers scellés pour catégorie G - Au niveau du sol (CEI 61753-111-8:2009)Fibre optic interconnecting devices and passive components - Performance standard - Part 111-8: Sealed closures for category G - Ground (IEC 61753-111-8:2009)33.180.20Fibre optic interconnecting devicesICS:Ta slovenski standard je istoveten z:EN 61753-111-8:201SIST EN 61753-111-8:2010en,fr01-april-2010SIST EN 61753-111-8:2010SLOVENSKI
STANDARD
EUROPEAN STANDARD EN 61753-111-8 NORME EUROPÉENNE
EUROPÄISCHE NORM February 2010
CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2010 CENELEC -
All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61753-111-8:2010 E
ICS 33.180.20
English version
Fibre optic interconnecting devices and passive components
performance standard -
Part 111-8: Sealed closures for category G -
Ground (IEC 61753-111-8:2009)
Dispositifs d'interconnexion et composantspassifs à fibres optiques norme de qualité de fonctionnement -
Partie 111-8: Boîtiers scellés
pour catégorie G - Au niveau du sol (CEI 61753-111-8:2009)
Lichtwellenleiter -
Verbindungselemente und passive Bauteile -
Betriebsverhalten -
Teil 111-8: Druckdichte Muffen
für die Kategorie G - Bodenverlegung (IEC 61753-111-8:2009)
This European Standard was approved by CENELEC on 2010-02-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.
- 2 -
Foreword The text of document 86B/2905/FDIS, future edition 1 of IEC 61753-111-8, prepared by SC 86B, Fibre optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61753-111-8 on 2010-02-01. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates were fixed: – latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement
(dop)
2010-11-01 – latest date by which the national standards conflicting
with the EN have to be withdrawn
(dow)
2013-02-01 Annex ZA has been added by CENELEC. __________ Endorsement notice The text of the International Standard IEC 61753-111-8:2009 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60068-1 NOTE
Harmonized as EN 60068-1. IEC 60068-2 NOTE
Harmonized in EN 60068-2 series (not modified). IEC 60721-3-1 NOTE
Harmonized as EN 60721-3-1. IEC 60793-2 NOTE
Harmonized as EN 60793-2. IEC 60794-1-2 NOTE
Harmonized as EN 60794-1-2. IEC 60794-2 NOTE
Harmonized as EN 60794-2. IEC 60794-3 NOTE
Harmonized as EN 60794-3. IEC 61300 NOTE
Harmonized in EN 61300 series (not modified). IEC 62005 NOTE
Harmonized in EN 62005 series (not modified). __________
- 3 - EN 61753-111-8:2010
Annex ZA (normative)
Normative references to international publications with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
NOTE
When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies.
Publication Year Title EN/HD Year
IEC 60068-2-10 - Environmental testing -
Part 2-10: Tests - Test J and guidance:
Mould growth EN 60068-2-10 -
IEC 60721-3-2 - Classification of environmental conditions -
Part 3: Classification of groups of environmental parameters
and their severities - Section 2: TransportationEN 60721-3-2 -
IEC 60793-2-50 2008 Optical fibres -
Part 2-50: Product specifications - Sectional specification for class B single-mode fibres EN 60793-2-50 2008
IEC 61300-1 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures -
Part 1: General and guidance EN 61300-1 -
IEC 61300-2-1 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures -
Part 2-1: Tests - Vibration (sinusoidal) EN 61300-2-1 -
IEC 61300-2-4 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures -
Part 2-4: Tests - Fibre/cable retention EN 61300-2-4 -
IEC 61300-2-5 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures -
Part 2-5: Tests - Torsion EN 61300-2-5 -
IEC 61300-2-9 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures -
Part 2-9: Tests - Shock EN 61300-2-9 -
IEC 61300-2-11 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures -
Part 2-11: Tests - Axial compression EN 61300-2-11 -
IEC 61300-2-12 2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures -
Part 2-12: Tests - Impact EN 61300-2-12 2009
IEC 61300-2-22 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures -
Part 2-22: Tests - Change of temperature EN 61300-2-22 -
- 4 -
Publication Year Title EN/HD Year
IEC 61300-2-26 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures -
Part 2-26: Tests - Salt mist EN 61300-2-26 -
IEC 61300-2-33 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures -
Part 2-33: Tests - Assembly and disassembly of fibre optic closures EN 61300-2-33 -
IEC 61300-2-34 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures -
Part 2-34: Tests - Resistance to solvents and contaminating fluids of interconnecting components and closures EN 61300-2-34 -
IEC 61300-2-37 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures -
Part 2-37: Tests - Cable bending for fibre optic closures EN 61300-2-37 -
IEC 61300-2-38 2006 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures -
Part 2-38: Tests - Sealing for pressurized fibre optic closures EN 61300-2-38 2006
IEC 61300-3-1 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures -
Part 3-1: Examinations and measurements - Visual examination EN 61300-3-1 -
IEC 61300-3-3 2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures -
Part 3-3: Examinations and measurements - Active monitoring of changes in attenuation and return loss EN 61300-3-3 2009
IEC 61300-3-28 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures -
Part 3-28: Examinations and measurements - Transient loss EN 61300-3-28 -
IEC 61753-1 2007 Fibre optic interconnecting devices and passive components performance standard - Part 1: General and guidance for performance standards EN 61753-1 2007
IEC 61753-111-7 - Fibre optic interconnecting devices and passive components - Performance standard -Part 111-7: Sealed closures for category A - Aerial EN 61753-111-7 -
IEC 62134-1 - Fibre optic interconnecting devices and passive components - Fibre optic closures -
Part 1: Generic specification EN 62134-1 -
ISO 4892-3 2006 Plastics - Methods of exposure to laboratory light sources -
Part 3: Fluorescent UV lamps
EN ISO 4892-3 2006
IEC 61753-111-8Edition 1.0 2009-11INTERNATIONAL STANDARD NORME INTERNATIONALEFibre optic interconnecting devices and passive components performance standard –
Part 111-8: Sealed closures for category G – Ground
Dispositifs d'interconnexion et composants passifs à fibres optiques norme de qualité de fonctionnement –
Partie 111-8: Boîtiers scellés pour catégorie G – Au niveau du sol
INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ELECTROTECHNIQUE INTERNATIONALE SICS 33.180.20 PRICE CODECODE PRIXISBN 2-8318-1067-4
– 2 – 61753-111-8 © IEC:2009 CONTENTS FOREWORD.3 INTRODUCTION.5 1 Scope.6 2 Normative references.6 3 Terms, definitions and abbreviations.7 4 General requirements.7 4.1 Storage, transportation and packaging.7 4.2 Marking and identification.8 4.3 Materials.8 4.4 Closure overpressure safety.8 4.5 Test report.8 5 Test.9 5.1 General.9 5.2 Test specimen preparation.9 5.3 Test and measurement methods.9 5.4 Installation or intervention.10 5.5 Pass/fail criteria.10 6 Performance requirements.10 6.1 Sample size.10 6.2 Sealing, optical and appearance performance criteria.11 6.3 Mechanical sealing performance requirements.12 6.4 Environmental sealing performance requirements.14 6.5 Mechanical optical performance requirements.15 6.6 Environmental optical performance requirements.16 Annex A (normative)
Sample definition.17 Annex B (normative)
Sample size.19 Annex C (normative)
Intervention and reconfiguration/resplicing.20 Bibliography.22
Figure A.1 – Track joint configuration sample.17 Figure A.2 – Distribution joint configuration sample.18
Table 1 – Tightness, optical and appearance performance criteria.11 Table 2 – Mechanical sealing performance requirements.12 Table 3 – Environmental sealing performance requirements.14 Table 4 – Mechanical optical performance requirements.15 Table 5 – Environmental optical performance requirements.16 Table A.1 – Fibre type for testing.17 Table B.1 – Sample size.19
61753-111-8 © IEC:2009 – 3 – INTERNATIONAL ELECTROTECHNICAL COMMISSION ____________
FIBRE OPTIC INTERCONNECTING DEVICES
AND PASSIVE COMPONENTS PERFORMANCE STANDARD –
Part 111-8: Sealed closures for category G –
Ground