Aerospace series - Cables, electrical, aircraft use - Test methods - Part 810: Structural return loss

This standard specifies methods for measuring structural return loss for digital data transmission cable.
It shall be used together with EN 3475-100.

Luft- und Raumfahrt - Elektrische Leitungen für Luftfahrtverwendung - Prüfverfahren - Teil 810: Rückfluβdämpfung

Diese Norm legt Verfahren zur Messung der Rückflussdämpfung für Leitungen zur Digitaldatenübertragung fest.
Sie ist in Verbindung mit EN 3475-100 anzuwenden.

Série aérospatiale - Câbles électriques à usage aéronautique - Méthodes d'essais - Partie 810: Affaiblissement de réflexion structurel

Aeronavtika - Električni kabli za uporabo v zračnih plovilih - Preskusne metode - 810. del: Povratna izguba (SRL)

General Information

Status
Published
Publication Date
31-Mar-2009
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
18-Mar-2009
Due Date
23-May-2009
Completion Date
01-Apr-2009

Relations

Buy Standard

Standard
EN 3475-810:2009
English language
5 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Série aérospatiale - Câbles électriques à usage aéronautique - Méthodes d'essais - Partie 810: Affaiblissement de réflexion structurelAerospace series - Cables, electrical, aircraft use - Test methods - Part 810: Structural return loss49.060Aerospace electric equipment and systemsICS:Ta slovenski standard je istoveten z:EN 3475-810:2009SIST EN 3475-810:2009en01-maj-2009SIST EN 3475-810:2009SLOVENSKI
STANDARD



SIST EN 3475-810:2009



EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 3475-810February 2009ICS 49.060 English VersionAerospace series - Cables, electrical, aircraft use - Testmethods - Part 810: Structural return lossSérie aérospatiale - Câbles électriques à usageaéronautique - Méthodes d'essais - Partie 810:Affaiblissement de réflexion structurelLuft- und Raumfahrt - Elektrische Leitungen fürLuftfahrtverwendung - Prüfverfahren - Teil 810:RückflußdämpfungThis European Standard was approved by CEN on 11 July 2008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre:
Avenue Marnix 17,
B-1000 Brussels© 2009 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 3475-810:2009: ESIST EN 3475-810:2009



EN 3475-810:2009 (E) 2 Contents Page Foreword .31Scope .42Normative references .43Definition .44Preparation of specimens .45Apparatus .46Methods .47Requirements .5 SIST EN 3475-810:2009



EN 3475-810:2009 (E) 3 Foreword This document (EN 3475-810:2009) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of th
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.