Abstract

This part of IEC 61300 describes a method for measuring the endface geometry of rectangular multifibre ferrules having an IEC defined optical interface. The primary attributes are fibre position relative to the endface, endface angle relative to the guide holes, fibre tip radii and core dip for multimode fibres.

Status
Published
Public Enquiry End Date
31-Mar-2025
Publication Date
24-Sep-2026
Technical Committee
MOC - Mobile Communications
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
16-Sep-2026
Due Date
21-Nov-2026
Completion Date
25-Sep-2026

Buy Documents

Standard

SIST EN IEC 61300-3-30:2026

English language (24 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN IEC 61300-3-30:2026 is SIST’s adoption of the IEC method for measuring the endface geometry of rectangular multifibre ferrules with an IEC defined optical interface. It specifies how to measure fibre position, endface angle relative to the guide holes, fibre tip radii, and core dip for multimode fibres. The standard is aimed at engineers, laboratories, manufacturers, and quality teams that need repeatable interferometric inspection of fibre optic connector ferrules.

What does SIST EN IEC 61300-3-30:2026 specify?

SIST EN IEC 61300-3-30:2026 specifies a test and measurement method for the endface geometry of rectangular multifibre ferrules. The method is built around a three-dimensional interferometry analysis of the ferrule endface, with results tied to the guide holes that locate the ferrule in the connector.

The document is organized into eight clauses and six normative annexes. The clauses cover scope, references, terms, the general measurement model, measurement regions, apparatus, procedure, and reporting. The annexes provide the geometry formulae, sign conventions, fibre counting convention, coplanarity analysis, core dip calculation, and GL calculation.

AnnexWhat it covers
AFormulae for approximating the endface geometry
BSurface angle sign convention
CFibre counting convention
DMinus coplanarity and fibre plane angle determination
ECalculation of core dip using the paraboloid method
FCalculation of GL parameter

What are the key requirements of SIST EN IEC 61300-3-30:2026?

Geometry model and measurement regions

Clause 4 models the ferrule endface as a rectangular surface with long and short axes and defines the measured angles SX and SY relative to the guide holes. In practice, this is what makes the measurements meaningful for mating connectors, because the endface has to be oriented correctly for physical contact.

Clause 5 defines the regions used in the analysis: the ROI, extracting region, averaging region, and core dip region. The ROI is centered on the fibre array and covers the intended contact zone, while Table 1 assigns the measurement areas and region sizes to each ferrule type. This matters because the software must use the right region geometry for the specific connector variant.

Apparatus and measurement quality

Clause 6 requires a ferrule holder, positioning stage, interferometric video microscope, PC-based fringe interpretation unit, and monitor. The three-dimensional interferometry analyser must measure fibre heights within ±50 nm and core dips within ±20 nm. That level of precision is needed because the geometry features being judged are very small and the results depend on stable surface metrology.

Clause 6 also requires calibration of microscope magnification, phase shift actuator travel, and ferrule holder tilt for angled ferrules. In practice, users need to verify the setup before measurement so the fitted surface and derived angles are traceable to the actual instrument geometry.

Step-by-step procedure and calculated outputs

Clause 7 sets out a staged analysis from data set A through G. It maps the ferrule surface, removes the extracting regions, fits a bi-parabolic surface, removes high outliers, keeps the highest 20 % of points, and then fits the best-fit plane used for SX and SY. This sequence matters because the method is designed to focus on the contact-relevant points and reduce the effect of isolated high spots.

Clause 7 then calculates fibre height H, adjacent fibre height differential HA, ferrule surface radii RX and RY, and fibre tip spherical radii RF. For multimode fibres, it also calculates core dip C using Annex E, with a 10 nm threshold that determines whether C is reported for an individual fibre. In practice, this gives the user both overall ferrule shape and fibre-level surface detail.

Annex D adds minus coplanarity CF and the fibre plane angles GX and GY. The annex gives separate analysis paths for single-row ferrules and multi-row ferrules, so the counting pattern of the ferrule affects the way the results are calculated. Clause 7 also calls for GL when core dip is reported for 50 % or fewer fibres, using the median RF of fibres with negative C.

Formulae and reporting

Annex A gives the least-squares formulae used to approximate the ferrule surface and the fibre tip as ideal geometric shapes. Annex B defines the sign convention for endface angles, and Annex C defines how fibres are counted across the array. These conventions are important because they keep results consistent between instruments and between ferrule layouts.

Clause 8 requires the relevant specification and test report to identify the DUT characteristics, measurement setup, uncertainty, the measured and calculated parameters, and any deviations from the procedure. That means a test report should be usable as a technical record of how the ferrule was measured, not just as a final pass/fail statement.

What terms does SIST EN IEC 61300-3-30:2026 define?

  • Region of interest (ROI) - the rectangular area on the ferrule surface that covers the intended contact zone and is centered on the fibre array.
  • Extracting region - the circular area around each fibre, including the fibre endface and associated adhesive region, that is removed before the ferrule surface fit.
  • Averaging region - the circular area on each fibre surface used to calculate fibre height H.
  • Core dip region - the circular area on each fibre surface used for the paraboloid fit that produces core dip C.
  • Minus coplanarity (CF) - the greatest parallel offset between the best-fit fibre plane or line and the lowest fibre end relative to that plane or line.
  • Geometry limit (GL) - a merit function used to quantify the acceptability of an endface geometry from SX, CF, and RF.
  • Fibre plane X-axis angle (GX) and fibre plane Y-axis angle (GY) - the tilt of the fitted fibre plane relative to the average guide hole axes.

Who uses SIST EN IEC 61300-3-30:2026?

SIST EN IEC 61300-3-30:2026 is used by manufacturers of fibre optic interconnecting devices and passive components, especially when working with rectangular multifibre ferrules and guide pin based connector plugs. It is also used by test laboratories, product development teams, and quality assurance staff who need a common measurement method for polish angle, fibre height, tip radius, and core dip.

Buyers and incoming inspection teams can use it to compare supplier measurements and to specify what must appear in a report. It is also relevant to anyone evaluating MT or MPO connector families and related ferrule types in manufacturing or certification work.

What changed in SIST EN IEC 61300-3-30:2026 from the previous edition?

SIST EN IEC 61300-3-30:2026 replaces SIST EN IEC 61300-3-30:2021. The foreword identifies these technical changes from the previous edition:

  • clarification of region diameter symbols;
  • introduction of x116 and x132 regions of interest to support MT-16 and MT-32 ferrule types;
  • preparation of GL parameter tables for 16-, 24- and 32-fibre ferrules;
  • clarification of the neighbouring fibres definition when computing adjacent height;
  • improved figures in the annexes.

Which standards are used with SIST EN IEC 61300-3-30:2026?

The bibliography links this method to the IEC 61300 family and to related connector-interface standards:

  • IEC 61300 (all parts) - the parent series of basic test and measurement procedures for fibre optic interconnecting devices and passive components.
  • IEC 61755-3-31:2015 - connector parameters for non-dispersion shifted single mode physically contacting fibres in angled polyphenylene sulphide rectangular ferrules.
  • IEC 61755-3-32:2015 - connector parameters for non-dispersion shifted single mode physically contacting fibres in angled thermoset epoxy rectangular ferrules.
  • IEC PAS 63267-3-30:2021 - end face geometry for angled PC end face PPS rectangular ferrule multimode A1b fibres.
  • IEC PAS 63267-3-31:2020 - end face geometry for flat PC PPS rectangular ferrule multimode fibres.
  • IEC 61754-5:2005 - Type MT connector family.
  • IEC 61754-7 (all parts) - Type MPO connector family.

What does the SIST EN IEC 61300-3-30:2026 document contain?

SIST EN IEC 61300-3-30:2026 contains the measurement regions, apparatus description, test sequence, and reporting items needed for interferometric inspection of rectangular ferrules. It also includes figures for the measurement setup, the region layout, surface angle sign convention, fibre counting, minus coplanarity, and the paraboloid core dip method.

The tables provide ferrule measurement areas and parameters for the covered ferrule types, plus GL parameter constants by fibre count. The annexes provide the formulae and conventions that software and test methods need for consistent design verification, laboratory testing, and inspection reporting.

Relations

Effective Date
01-Nov-2026
Effective Date
15-Sep-2026
Effective Date
15-Sep-2026
Effective Date
15-Sep-2026
Effective Date
15-Sep-2026
Effective Date
15-Sep-2026

Buy Documents

Standard

SIST EN IEC 61300-3-30:2026

English language (24 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

SIST EN IEC 61300-3-30:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-30: Examinations and measurements - Endface geometry of rectangular ferrule (IEC 61300-3-30:2026)". This standard covers: This part of IEC 61300 describes a method for measuring the endface geometry of rectangular multifibre ferrules having an IEC defined optical interface. The primary attributes are fibre position relative to the endface, endface angle relative to the guide holes, fibre tip radii and core dip for multimode fibres.

This part of IEC 61300 describes a method for measuring the endface geometry of rectangular multifibre ferrules having an IEC defined optical interface. The primary attributes are fibre position relative to the endface, endface angle relative to the guide holes, fibre tip radii and core dip for multimode fibres.

SIST EN IEC 61300-3-30:2026 is classified under the following ICS (International Classification for Standards) categories: 33.180.20 - Fibre optic interconnecting devices. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN IEC 61300-3-30:2026 has the following relationships with other standards: It is inter standard links to SIST EN IEC 61300-3-30:2021, SIST EN IEC 63267-3-81:2025, SIST EN 50377-11-1:2008, SIST EN 61755-3-31:2016, SIST EN 61300-1:2017, SIST EN 61755-3-32:2016. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN IEC 61300-3-30:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 General description
  • 5 Measurement regions
  • 6 Apparatus
  • 6.1 General
  • 6.2 Ferrule holder
  • 6.3 Positioning stage
  • 6.4 Three-dimensional interferometry analyser
  • 7 Procedure
  • 8 Details to be specified and reported
  • Annex A
  • Annex B
  • Annex C
  • Annex D
  • Annex E
  • Annex E describes the core dip parameter that shall be calculated and reported for
  • Annex F
  • Annex F describes the GL parameter that shall be calculated and reported for measurements
  • Bibliography

1 Scope

This part of IEC 61300 describes a method for measuring the endface geometry of rectangular multifibre ferrules having an IEC defined optical interface. The primary attributes are fibre position relative to the endface, endface angle relative to the guide holes, fibre tip radii and core dip for multimode fibres.

2 Normative references

There are no normative references in this document.

3 Terms and definitions

No terms and definitions are listed in this document.

ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • IEC Electropedia: available at https://www.electropedia.org/
  • ISO Online browsing platform: available at https://www.iso.org/obp

4 General description

Guide pin based multifibre connector plugs in IEC 61754-5 and all parts of IEC 61754-7 typically have a rectangular endface with a long axis and a short axis. Ideally a flat polish is desired on the endface with the fibres protruding slightly and all in the same plane to assure physical contact of the fibre cores when two connectors are intermated. In practice, the endface typically has two different curvatures across the surface along the long and short axis. Since mated ferrules are aligned by pins in the guide holes, the endface of the ferrule shall be properly oriented (SX and SY angles) with respect to the guide holes to achieve positive contact. The endface angle SX in the long axis (X-axis) and the endface angle SY in the short axis (Y-axis) (as defined in Annex B) are measured by finding the best fit plane (P ), based on a percentage J of the highest points in a specified region of interest. The highest points typically show the greatest modulation from an interferometric standpoint. This allows for more robust measurements and greater repeatability between different interferometers. The angle of the best fit plane P is calculated by comparing it to the reference plane P which J is perpendicular to the averaged axis of the guide holes. The height H (positive is a protrusion) of the fibres is a planar height defined as the distance between the fibre endface and the best fit plane. Core dip is only relevant to multimode fibres because the large core is softer than the cladding of the fibre and tends to polish away faster. Core dip is calculated using the paraboloid method described in Annex E.

One method is described for measuring the polish angle and fibre position for a single ferrule multifibre connector by analysing the endface with a three-dimensional interferometry type surface analyser.

SIST EN IEC 61300-3-30:2026

5 Measurement regions

The following regions shall be defined on the ferrule endface. a) Region of interest (ROI): the ROI is set on the ferrule surface and defined by a rectangular region having a long axis (X-axis) and a short axis (Y-axis). The region of interest is chosen to cover the intended contact zone of the ferrule endface when the ferrules are mated. The region of interest shall be centred on the fibre array. See Figure 1. Refer to Table 1 for measurement areas that shall be used for different connectors. b) Extracting region: the extracting region, which includes the fibre endface regions and the associated adhesive regions, is defined by circles having a diameter Ø , centred on each E fibre.

c) Averaging region: the averaging region is set on the fibre surfaces used to calculate the fibre height, and is defined by a circle having a diameter Ø . The averaging region is the F same for single-mode (SM) fibres and multimode (MM) fibres.

d) Core dip region: the core dip region is set on the fibre surfaces used to calculate the fibre core dip using the paraboloid method, and is defined by circles having a diameter Ø , CDIP centred on each fibre.

Additionally, core dip adjustment constant: the calculated core dip amplitude following the fit of a paraboloid function to the fibre endface is adjusted by means of constant R .

Figure 1 – Measurement regions on ferrule and fibre

SIST EN IEC 61300-3-30:2026

Table 1 – Ferrule measurement areas and parameters Ferrule Descrip- Region of % top Next % Extracting Averaging Core dip Core dip type tion interest ROI pixels top region region- fitting region adjustment (variant excluded pixels (diameter Ø ) SM+MM (diameter constant (X × Y) E number) used (diameter Ø ) Ø ) R (see F CDIP 1 a

Annex E) mm × mm mm mm mm 1104 MT-04 2,900 × 0,675 3 20 0,140 0,05 0,03 0,03 Y 1108 MT-08 2,900 × 0,675 3 20 0,140 0,05 0,03 0,03 Y 1112 MT-12 2,900 × 0,675 3 20 0,140 0,05 0,03 0,03 Y 1116 MT-16 3,900 × 0,675 3 20 0,140 0,05 0,03 0,03 Y 1124 MT-24 2,900 × 1,160 3 20 0,140 0,05 0,03 0,03 Y 1132 MT-32 3,900 × 1,160 3 20 0,140 0,05 0,03 0,03 Y 1002 MiniMT 0,900 × 0,675 3 20 0,140 0,05 0,03 0,03 Y a The first digit defines 1 for PPS ferrule materials; the second digit represents 2,45 mm × 4,4 mm with 0 and 2,45 mm × 6,4 mm with 1; the last two digits designates the number of fibres (see Table 1 of IEC 61755-3-31:2015, Table 1 of IEC PAS 63267-3-30:2021 and Table 1 of IEC PAS 63267-3-31:2020); and the subscript Y defines S for single-mode fibres and M for multimode fibres.

6 Apparatus

6.1 General

The apparatus shown in Figure 2 consists of a positioning stage, a ferrule holder, an interferometric video microscope, a PC-based fringe interpretation unit and a monitor to view the ferrule endface interferogram and display the analysis results.

Figure 2 – Measurement setup

SIST EN IEC 61300-3-30:2026

6.2 Ferrule holder

The ferrule holder is a suitable device to hold the ferrule in a fixed position, either vertical or horizontal, or in a tilted position in the case of an angled ferrule type. Methods such as mechanical alignment or interferometric measurement shall be used to determine the axis of each guide hole and the average plane perpendicular to the guide hole axes. This plane shall be considered as the reference plane P for reference to subsequent calculations.

6.3 Positioning stage

The ferrule holder is fixed to the positioning stage, which shall enable the ferrule holder to be moved to the appropriate position. The stage shall have sufficient rigidity to allow measurement of the ferrule endface parameters within the required uncertainties detailed in 6.4.

6.4 Three-dimensional interferometry analyser

The three-dimensional interferometry analyser shall have the ability to measure the fibre heights on the ferrule endface with an uncertainty within ±50 nm and the core dips with an uncertainty within ±20 nm. The analyser shall consist of an interferometric video microscope unit, a PC-based fringe interpretation (surface data processing) unit and a monitor. The interferometric video microscope unit shall consist of an interference microscope, a phase shift actuator, an image detector and an image acquisition and processing setup. The interference microscope equipped with an objective is arranged so as to view the endface of the ferrule.

The following parameters of the interference microscope shall be calibrated:

  • optical magnification of the microscope;
  • Z travel of the phase shift actuator;
  • ferrule holder tilt angle in the case of an angled ferrule type. The surface data processing unit shall be able to process the surface height information so as to measure the following parameters:

...