Cables of rated voltages up to and including 450/750 V and having cross-linked insulation -- Part 3: Heat resistant silicone rubber insulated cables

Superseded by EN 50525-2-41 (PR=21972)

Starkstromleitungen mit vernetzter Isolierhülle für Nennspannungen bis 450/750 V -- Teil 3: Wärmebeständige Silikonaderleitungen

Conducteurs et câbles isolés avec des matériaux réticulés de tension assignée au plus égale à 450/750 V -- Partie 3: Conducteurs isolés au silicone résistant à la chaleur

Kabli z omreženo izolacijo za naznačene napetosti do vključno 450/750 V – 3. del: Kabli s toplotno odporno silikonsko gumijasto izolacijo

General Information

Status
Withdrawn
Publication Date
30-Apr-2006
Withdrawal Date
06-Jan-2014
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
06-Jan-2014
Due Date
29-Jan-2014
Completion Date
07-Jan-2014

Relations

Buy Standard

Amendment
HD 22.3 S4:2004/A1:2006
English language
3 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI SIST HD 22.3 S4:2004/A1:2006

STANDARD
may 2006
Kabli z omreženo izolacijo za naznačene napetosti do vključno 450/750 V – 3.
del: Kabli s toplotno odporno silikonsko gumijasto izolacijo
Cables of rated voltages up to and including 450/750 V and having cross-linked
insulation – Part 3: Heat resistant silicone rubber insulated cables
ICS 29.060.20 Referenčna številka
SIST HD 22.3 S4:2004/A1:2006(en)
©  Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno

---------------------- Page: 1 ----------------------

HARMONIZATION DOCUMENT
HD 22.3 S4/A1

DOCUMENT D'HARMONISATION
February 2006
HARMONISIERUNGSDOKUMENT

ICS 29.060.20


English version


Cables of rated voltages up to and including 450/750 V
and having cross-linked insulation
Part 3: Heat resistant silicone rubber insulated cables



Conducteurs et câbles isolés  Starkstromleitungen mit vernetzter
avec des matériaux réticulés de tension Isolierhülle für Nennspannungen
assignée au plus égale à 450/750 V bis 450/750 V
Partie 3: Conducteurs isolés au silicone Teil 3: Wärmebeständige
résistant à la chaleur Silikonaderleitungen





This amendment A1 modifies the Harmonization Document HD 22.3 S4:2004; it was approved by CENELEC on
2005-12-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for implementation of this amendment at national level.

Up-to-date lists and bibliographical references concerning such national implementations may be obtained on
application to the Central Secretariat or to any CENELEC member.

This amendment exists in three official versions (English, French, German).

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Polan
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.