SIST EN 13170:2013/kFprA1:2014
(Amendment)Thermal insulation products for buildings - Factory made products of expanded cork (ICB) - Specification
Thermal insulation products for buildings - Factory made products of expanded cork (ICB) - Specification
This European Standard specifies the requirements for factory made products of expanded cork, which are used for the thermal insulation of buildings. The products are made with granulated cork agglomerated without additional binders and are delivered as boards without facings or coatings.
Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.
This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.
This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non conflicting standards.
Products with a declared thermal resistance lower than 0,25 m2 K/W, or a declared thermal conductivity greater than 0,060 W/(m K), at 10 °C, are not covered by this European Standard.
Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus expandiertem Kork (ICB) - Spezifikation
Produits isolants thermiques pour le bâtiment - Produits manufacturés en liège expansé (ICB) - Spécification
Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz ekspandirane plute (ICB) - Specifikacija
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 13170:2013/kFprA1:2014
01-november-2014
Toplotnoizolacijski proizvodi za stavbe - Proizvodi iz ekspandirane plute (ICB) -
Specifikacija
Thermal insulation products for buildings - Factory made products of expanded cork
(ICB) - Specification
Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus expandiertem
Kork (ICB) - Spezifikation
Produits isolants thermiques pour le bâtiment - Produits manufacturés en liège expansé
(ICB) - Spécification
Ta slovenski standard je istoveten z: EN 13170:2012/FprA1
ICS:
91.100.60 0DWHULDOL]DWRSORWQRLQ Thermal and sound insulating
]YRþQRL]RODFLMR materials
SIST EN 13170:2013/kFprA1:2014 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 13170:2013/kFprA1:2014
---------------------- Page: 2 ----------------------
SIST EN 13170:2013/kFprA1:2014
EUROPEAN STANDARD
FINAL DRAFT
EN 13170:2012
NORME EUROPÉENNE
EUROPÄISCHE NORM
FprA1
August 2014
ICS 91.100.60
English Version
Thermal insulation products for buildings - Factory made
products of expanded cork (ICB) - Specification
Produits isolants thermiques pour le bâtiment - Produits Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte
manufacturés en liège expansé (ICB) - Spécification Produkte aus expandiertem Kork (ICB) - Spezifikation
This draft amendment is submitted to CEN members for unique acceptance procedure. It has been drawn up by the Technical Committee
CEN/TC 88.
This draft amendment A1, if approved, will modify the European Standard EN 13170:2012. If this draft becomes an amendment, CEN
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of this amendment
into the relevant national standard without any alteration.
This draft amendment was established by CEN in three official versions (English, French, German). A version in any other language made
by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has
the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and
shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 13170:2012/FprA1:2014 E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
SIST EN 13170:2013/kFprA1:2014
EN 13170:2012/FprA1:2014 (E)
Contents Page
Foreword .3
1 Modification to the Foreword .4
2 Modifications to 3.2, Symbols, units and abbreviated terms .4
3 Modification to 4.3.13, Release of dangerous substances .4
4 Modification to Clause 7, Evaluation of conformity .4
5 Modification to Clause 8, Marking and labelling .5
6 Modifications to Annex B, Initial type testing (ITT) and factory production control (FPC) .5
7 Modification to Annex ZA, Clauses of this European Standard addressing the provisions
of the EU Construction Products Directive .5
2
---------------------- Page: 4 ----------------------
SIST EN 13170:2013/kFprA1:2014
EN 13170:2012/FprA1:2014 (E)
Foreword
This document (EN 13170:2012/FprA1:2014) has been prepared by Technical Committee CEN/TC 88
“Thermal insulating materials and products”, the secretariat of which is held by DIN.
This document is currently submitted to the Unique Acceptance Procedure.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Construction Products Regulation (CPR), see informative Annex ZA, which is an
integral part of this standard.
NOTE Due to fact that the Framework Partnership Agreement between the Commission and CEN & CENELEC is not
signed yet, there are currently no New Approach Consultants in place for 2014. Therefore the provisions of CEN-
CENELEC Guide 15 cannot be met.
This shall not prevent the processing of draft standards nor the offering of harmonized standards to the Commission. In
particular, draft standards can be sent to vote without Consultant assessment.
This note will be removed from the Foreword of the finalized publication.
This amendment (EN 13170:2012/FprA1:2013) modifies the European Standard EN 13170:2012 identifying
those clauses of the standard which are needed for the compliance of the European Standard with the
Construction Products Regulation (CPR).
This amendment introduces
a) an addition to the foreword;
b) an addition in 3.2;
c) a new subclause 4.3.13;
d) modification of Clause 7;
e) modification of Clause 8;
f) modification of Annex B;
g) a new Annex ZA.
3
---------------------- Page: 5 ----------------------
SIST EN 13170:2013/kFprA1:2014
EN 13170:2012/FprA1:2014 (E)
1 Modification to the Foreword
th
Replace the 6 paragraph with the following paragraph:
"For relationship with EU Construction Products Regulation (CPR), see informative Annex ZA, which is an
integral part of this standard.".
2 Modifications to 3.2, Symbols, units and abbreviated terms
Replace
"ITT is Initial Type Test" with
"PTD is Product Type Determination (previously named ITT for Initial Type Test)"
and add the following abbreviated terms:
"AVCP is Assessment and Verification of Constancy of Performance (previously named attestation of
conformity)
DoP is Declaration of Performance
ThI is Thermal Insulation for Buildings
VCP is Verification of Constancy of Performance (previously named evaluation of conformity)".
3 Modification to 4.3.13, Release of dangerous substances
Replace the text of 4.3.13 with:
"National regulations on dangerous substances may require verification and declaration on release, and
sometimes content, when construction products covered by this standard are placed on those markets.
In the absence of European harmonized test methods, verification and declaration on release/content should
be done taking into account national provisions in the place of use.
NOTE An informative database covering European and national provisions on dangerous substances is available at
the Construction web site on EUROPA accessed through: http://ec.europa.eu/enterprise/construction/cpd-ds/.".
4 Modification to Clause 7, Evaluation of conformity
Replace Clause 7 with:
"
7 Assessment and Verification of the Constancy of Performance (AVCP)
7.1 General
The manufacturer or his authorized representative shall be responsible for the conformity of his product with
the requirements of this European Standard. The Assessment and Verification of Constancy of Performance
(AVCP) shall be carried out in accordance with EN 13172 and shall be based on Product Type Determination
(PTD), Factory Production Control (FPC) by the manufacturer, including product assessment and tests on
samples taken at the factory.
The compliance of the product with the requirements of this standard and with the stated values (including
classes) shall be demonstrated by:
4
---------------------- Page: 6 ----------------------
SIST EN 13170:2013/kFprA1:2014
EN 13170:2012/FprA1:2014 (E)
Product Type Determination (PTD),
Factory Production Control (FPC) by the manufacturer, including product assessment.
If a manufacturer decides to group his products, it shall be done in accordance with EN 13172.
7.2 Product Type Determination (PTD)
All characteristics defined in 4.2 and those in 4.3 if declared, shall be subject to Product Type Determination
(PTD) in accordance with Annex B.
7.3 Factory Production Control (FPC)
The minimum frequencies of tests in the factory production control (FPC) shall be in accordance with
Annex B. When indirect testing is used, the correlation to direct testing shall be established in accordance with
EN 13172.".
5 Modification to Clause 8, Marking and labelling
Add the following indent: "
the intended use of the expanded cork for insulation of buildings is given by the abbreviation ThlB.".
6 Modifications to Annex B, Initial type testing (ITT) and factory production control
(FPC)
Replace "Initial type testing" with "Product type determination" and "ITT" with "PTD" within Annex B in:
Annex B, title;
Table B.1, title;
nd st
Table B.1, 2 column, 1 line, title;
rd
column;
Table B.1, line 4.2.1, 3
th
Table B.1, line 4.3.16, 4 column;
Table B.1, text of footnote b;
Table B.1, text of footnote d.
7 Modification to Annex ZA, Clauses of this European Standard addressing the
provisions of the EU Construction Products Directive
Replace the existing Annex ZA with the following new Annex ZA:
"
5
---------------------- Page: 7 ----------------------
SIST EN 13170:2013/kFprA1:2014
EN 13170:2012/FprA1:2014 (E)
Annex ZA
(informative)
Clauses of this European Standard addressing the provisions of the
EU Construction Products Regulation
ZA.1 Scope and relevant characteristics
1)
This European Standard has been prepared under Mandate M/103 "Thermal insulation products" given to CEN
by the European Commission and the European Free Trade Association.
If this European standard is cited in the Official Journal of the European Union (OJEU), the clauses of this
standard, shown in this annex, are considered to meet the provisions of the relevant mandate, under the
Regulation (EU) No. 305/2011.
This annex deals with the CE marking of the factory made expanded cork intended for the use indicated in
Table ZA.1 and shows the relevant clauses applicable.
This annex has the same scope as Clause 1 of this standard related to the aspects covered by the mandate
and is defined by Table ZA.1
Table ZA.1 — Relevant clauses for factory made expanded cork and intended use
Product: Factory made expanded cork (ICB) products
Intended use: Thermal insulation for buildings
Clauses in this and other European
Regulatory
Essential Characteristics standard(s) related to essential Notes
classes
f
characteristics
Declared R and λ
Thermal resistance and
D D
4.2.1 —
thermal conductivity
Thermal resistance
if possible
Declared d and T
4.2.3 Thickness —
N
Reaction to fire 4.2.6 Reaction to fire Euroclasses —
Durability of reaction to fire against
a
4.2.7 Euroclasses —
Durability characteristics
heat, weathering, ageing/degradation
Declared R and λ
Thermal resistance and
D D
Durability of thermal resistance
4.2.1 —
thermal conductivity
b
against heat, weathering, if possible
ageing/degradation
4.2.7 Durability characteristics —
c
Compressive stress or
4.3.3 —
Declared CS
compressive strength
Compressive strength
4.3.5 Point load —
Declared PL
—
Tensile strength
Tensile/Flexural strength
4.3.4 Declared TR
d
perpendicular to faces
Durability of compressive strength
4.3.6 Compressive creep — Declared CC
against ageing/degradation
Water permeability 4.3.7 Short term water absorption — Declared WS
Water vapour permeability 4.3.8 Water vapour transmission — Declared MU or Z
4.3.9 Dynamic stiffness — Declared SD
Impact noise transmission index (for
1)
As amended by mandates M126, M130 and M367
6
---------------------- Page: 8 ----------------------
SIST EN 13170:2013/kFprA1:2014
EN 13170:2012/FprA1:2014 (E)
Product: Factory made expanded cork (ICB) products
Intended use: Thermal insulation for buildings
Clauses in this and other European
Regulatory
standard(s) related to essential
Essential Characteristics Notes
classes
f
characteristics
floors) Declared d and class
4.3.10.2 Thickness —
L
4.3.10.4 Compressibility — Declared CP
Declared AF
4.3.12 Air flow resistivity —
r
Acoustic absorption index 4.3.11 Sound absorption — Declared AP and AW
Direct airborne sound insulation
Declared AF
4.3.12 Air flow resistivity —
r
index
Release of dangerous
Release of dangerous substances to
4.3.13 — —
e
the indoor environment
substances
Continuous glowing
Continuous glowing combustion 4.3.15 — —
e
combustion
a
No change in reaction to fire properties for ICB products.
The fire performance of ICB does not deteriorate with time.
b
Thermal conductivity of ICB products does not change with time, experience has shown the fibre structure to be stable and the
porosity contains no other gases than atmospheric air.
c
For dimensional stability thickness only.
d
This characteristic also covers handling and installation.
e
European test methods are under development.
f
Also valid and applicable for multilayers.
The declaration of the product performance related to certain essential characteristics is not required in those
Member States (MS) where there are no regulatory requirements on these essential characteristics for the
intended use of the product. In this case, manufacturers placing their products on the market of these MS are
not obliged to determine nor declare the performance of their products with regard to these essential
characteristics and the option “No performance determined” (NPD) in the information accompanying the CE
marking and in the declaration of performance (see ZA.3) may be used for those essential characteristics.
ZA.2 Procedures for AVCP of factory made expanded cork products
ZA.2.1 Systems of AVCP
The AVCP systems of factory made expanded cork indicated in Table ZA.1, established by EC Decision
95/204/EC of 31.05.95 (OJ L 129) revised by decision 99/91/EC of 25.01.99 (OJ L 29) amended by the
th
decision 01/596/EC of 8 January 2001 (OJ L 209) is shown in Table ZA.2 for the indicated intended use and
relevant level(s) or class(es) of performance.
7
---------------------- Page: 9 ----------------------
SIST EN 13170:2013/kFprA1:2014
EN 13170:2012/FprA1:2014 (E)
Table ZA.2 — Systems of AVCP
Level(s)
or class(es)
Product(s) Intended use(s) AVCP system(s)
(reaction to fire)
a
Thermal insulation products For uses subject to (A1, A2, B, C) 1
(Factory made products) regulations on reaction to fire
b
(A1, A2, B, C) , D, E 3
c
(A1 to E) , F 4
Any — 3
System 1: See Regulation (EU) No. 305/2011 (CPR) Annex V, 1.2
System 3: See Regulation (EU) No. 305/2011 (CPR) Annex V, 1.4
System 4: See Regulation (EU) No. 305/2011 (CPR) Annex V, 1.5
a
Products/materials for which a clearly identifiable stage in the production process results in an improvement of the reaction to fire
classification (e.g. an addition of fire retardants or a limiting of organic material).
a
b
Products/materials not covered by footnote ( ).
c
Products/materials that do not require to be tested for reaction to fire (e.g. products/materials of classes A1 according to
Commission Decision 96/603/EC, as amended).
The AVCP of the factory made expanded cork products in Table ZA.1 shall be according to the AVCP
procedures indicated in Table ZA.3.1, Table ZA.3.2 and Table ZA.3.3 resulting from application of the clauses
of this or other European Standard indicated therein. The content of tasks of the notified body shall be limited
to those essential characteristics as provided for, if any, in Annex III of the relevant mandate and to those that
the manufacturer intends to declare.
8
---------------------- Page: 10 ------------
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.