AC motor capacitors - Part 2: Motor start capacitors

Ta del IEC 60252 velja za zaganjalne kondenzatorje, namenjene povezavi z navitji asinhronih motorjev, napajanih iz enofaznega sistema, ki imajo frekvenco javnega omrežja. Ta standard zajema zaganjalne kondenzatorje motorjev, ki so ali niso impregnirani in ki imajo dielektrik iz papirja ali plastičnega filma ali kombinacije obeh, ter elektrolitske zaganjalne kondenzatorje, ki nimajo trdnih elektrolitov, z ocenjeno napetostjo do in vključno 660 V.

Wechselspannungsmotorkondensatoren - Teil 2: Motoranlaufkondensatoren

Condensateurs des moteurs à courant alternatif - Partie 2: Condensateurs de démarrage de moteurs

Izmenični kondenzatorji za motorje - 2. del: Zaganjalni kondenzatorji

Ta del IEC 60252 velja za zaganjalne kondenzatorje, namenjene povezavi z navitji asinhronih motorjev, napajanih iz enofaznega sistema, ki imajo frekvenco javnega omrežja.
Ta standard zajema zaganjalne kondenzatorje motorjev, ki so ali niso impregnirani in ki imajo dielektrik iz papirja ali plastičnega filma ali kombinacije obeh, ter elektrolitske zaganjalne kondenzatorje, ki nimajo trdnih elektrolitov, z ocenjeno napetostjo do in vključno 660 V.

General Information

Status
Published
Publication Date
05-Dec-2013
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
03-Dec-2013
Due Date
07-Feb-2014
Completion Date
06-Dec-2013

Relations

Buy Standard

Amendment
EN 60252-2:2011/A1:2014 - BARVE
English language
11 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60252-2:2011/A1:2014
01-januar-2014
,]PHQLþQLNRQGHQ]DWRUML]DPRWRUMHGHO=DJDQMDOQLNRQGHQ]DWRUML
AC motor capacitors - Part 2: Motor start capacitors
Wechselspannungsmotorkondensatoren - Teil 2: Motoranlaufkondensatoren
Condensateurs des moteurs à courant alternatif - Partie 2: Condensateurs de démarrage
de moteurs
Ta slovenski standard je istoveten z: EN 60252-2:2011/A1:2013
ICS:
31.060.70 0RþQRVWQLNRQGHQ]DWRUML Power capacitors
SIST EN 60252-2:2011/A1:2014 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60252-2:2011/A1:2014

---------------------- Page: 2 ----------------------

SIST EN 60252-2:2011/A1:2014

EUROPEAN STANDARD
EN 60252-2/A1

NORME EUROPÉENNE
November 2013
EUROPÄISCHE NORM

ICS 31.060.30; 31.060.70


English version


AC motor capacitors -
Part 2: Motor start capacitors
(IEC 60252-2:2010/A1:2013)


Condensateurs des moteurs à courant Wechselspannungsmotorkondensatoren -
alternatif - Teil 2: Motoranlaufkondensatoren
Partie 2: Condensateurs de démarrage de (IEC 60252-2:2010/A1:2013)
moteurs
(CEI 60252-2:2010/A1:2013)




This amendment A1 modifies the European Standard EN 60252-2:2011; it was approved by CENELEC on 2013-
10-03. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate
the conditions for giving this amendment the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.

This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
CEN-CENELEC Management Centre has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels


© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60252-2:2011/A1:2013 E

---------------------- Page: 3 ----------------------

SIST EN 60252-2:2011/A1:2014
EN 60252-2:2011/A1:2013 - 2 -
Foreword
The text of document 33/533/FDIS, future IEC 60252-2:2010/A1, prepared by IEC/TC 33, "Power
capacitors and their applications" was submitted to the IEC-CENELEC parallel vote and approved by
CENELEC as EN 60252-2:2011/A1:2013.
The following dates are fixed:
(dop) 2014-07-03
• latest date by which the document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2016-10-03
• latest date by which the national
standards conflicting with the
document have to be withdrawn

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.

This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment
Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC).
Endorsement notice
The text of the International Standard IEC 60252-2:2010/A1:2013 was approved by CENELEC as a
European Standard without any modification.

---------------------- Page: 4 ----------------------

SIST EN 60252-2:2011/A1:2014
- 3 - EN 60252-2:2011/A1:2013
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE  When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Replace the reference to IEC 60529 and ISO 4046 by the following:

Publication Year Title EN/HD Year

IEC 60529 2001 Degrees of protection provided by enclosures - -
(IP Code)


ISO 4046 2002 Paper, board, pulps and related terms - - -
Vocabulary

---------------------- Page: 5 ----------------------

SIST EN 60252-2:2011/A1:2014

---------------------- Page: 6 ----------------------

SIST EN 60252-2:2011/A1:2014




IEC 60252-2

®


Edition 2.0 2013-08




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE
colour

inside



AMENDMENT 1

AMENDEMENT 1





AC motor capacitors –

Part 2: Motor start capacitors




Condensateurs des moteurs à courant alternatif –

Partie 2: Condensateurs de démarrage de moteurs
















INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE

PRICE CODE
INTERNATIONALE

CODE PRIX J


ICS 31.060.30; 31.060.70 ISBN 978-2-8322-1057-4



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 7 ----------------------

SIST EN 60252-2:2011/A1:2014
– 2 – 60252-2 Amend.1 © IEC:2013
FOREWORD
This amendment has been prepared by subcommittee 33: Power capacitors and their
applications.
The text of this amendment is based on the following documents:
FDIS Report on voting
33/533/FDIS 33/539/RVD

Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the stability date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

IMPORTANT – The 'colour inside' logo on the cover page of this publication indicates
that it contains colours which are considered to be useful for the correct
understanding of its contents. Users should therefore print this document using a
colour printer.


_____________

2 Normative references
Replace the reference to IEC 60529 by the following:
IEC 60529:2001, Degrees of protection provided by enclosures (IP Code)
Replace the reference to ISO 4046 by the following:
ISO 4046:2002, Paper, board, pulps and related terms – Vocabulary
3 Terms and definitions
3.29
class of safety protection
Replace definition 3.29 by the following:

---------------------- Page: 8 ----------------------

SIST EN 60252-2:2011/A1:2014
60252-2 Amend.1 © IEC:2013 – 3 –
3.29
class of safety protection
degree of safety protection identified by one of four codes to be marked on the capacitor
Note 1 to entry: This definition does not apply to electrolytic capacitors.
3.29.1
(SO) class of safety protection
degree of safety protection indicating that the capacitor type has no specific failure protection
Note 1 to entry: Formerly referred to as P0.
3.29.2
(S1) class of safety protection
degree of safety protection indicating that the capacitor type may fail in the open-circuit or
short-circuit mode and is protected against fire or shock hazard
Note 1 to entry: Compliance is verified by the test described in 5.1.16.3 and 5.1.16.5.
Note 2 to entry: Formerly referred to as P1.
3.29.3
(S2) class of safety protection
degree of safety protection indicating that the capacitor type has been designed to fail in the
open-circuit mode only and is protected against fire or shock hazard.
Note 1 to entry: Compliance is verified by the test described in 5.1.16.3 and 5.1.16.5.
Note 2 to entry: Formerly referred to as P2.
3.29.4
(S3) class of safety protection
degree of safety protection indicating that the capacitor is of segmented film construction as
defined in 3.6
Note 1 to entry: This capacitor type is required to fail with low residual capacitance (<1 % C ) and has protection
N
against fire and shock hazard. Compliance is verified by the test described in 5.1.16.4 and 5.1.16.6.

5.1.16 Destruction test
Replace Subclause 5.1.16 by the following:
5.1.16 Destruction test
5.1.16.1 General
This test is optional.
Refer to revised definition 3.29 for the appropriate test for each class of safety protection.
Capacitors marked S0 are not required to be tested in accordance with this subclause.
Capacitors fitted with overpressure disconnect device designated S1 and S2 shall be
subjected to the sequential DC and AC test described in 5.1.16.3 and 5.1.16.5.
Capacitors with segmented film as defined in 3.6 and designated S3 class of safety protection
shall be subjected to the simultaneous DC and AC test described in 5.1.16.4 and 5.1.16.6.

---------------------- Page: 9 ----------------------

SIST EN 60252-2:
...

Questions, Comments and Discussion