Aerospace series - Elements of electrical and optical connection - Test methods - Part 100: General

This document specifies the general requirements for the methods of testing elements of electrical, optical and data transmission system connections used in aerospace applications.

Luft- und Raumfahrt - Elektrische und optische Verbindungselemente - Prüfverfahren - Teil 100: Allgemeines

Série aérospatiale - Organes de connexion électrique et optique - Méthodes d'essais - Partie 100 : Généralités

Le présent document spécifie les exigences générales relatives aux méthodes d'essais des organes de connexion des systèmes électriques, optiques et de transmission de données utilisés dans les applications aérospatiales.

Aeronavtika - Električni in optični spojni elementi - Preskusne metode - 100. del: Splošno

General Information

Status
Not Published
Public Enquiry End Date
02-Aug-2022
Technical Committee
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
19-May-2022
Due Date
06-Oct-2022
Completion Date
08-Aug-2022

Relations

Buy Standard

Draft
prEN 2591-100:2022
English language
27 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
oSIST prEN 2591-100:2022
01-julij-2022
Aeronavtika - Električni in optični spojni elementi - Preskusne metode - 100. del:
Splošno
Aerospace series - Elements of electrical and optical connection - Test methods - Part
100: General
Luft- und Raumfahrt - Elektrische und optische Verbindungselemente - Prüfverfahren -
Teil 100: Allgemeines
Série aérospatiale - Organes de connexion électrique et optique - Méthodes d'essais -
Partie 100 : Généralités
Ta slovenski standard je istoveten z: prEN 2591-100
ICS:
49.060 Letalska in vesoljska Aerospace electric
električna oprema in sistemi equipment and systems
oSIST prEN 2591-100:2022 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN 2591-100:2022

---------------------- Page: 2 ----------------------
oSIST prEN 2591-100:2022


DRAFT
EUROPEAN STANDARD
prEN 2591-100
NORME EUROPÉENNE

EUROPÄISCHE NORM

May 2022
ICS 49.060; 49.090 Will supersede EN 2591-100:2018
English Version

Aerospace series - Elements of electrical and optical
connection - Test methods - Part 100: General
Série aérospatiale - Organes de connexion électrique et Luft- und Raumfahrt - Elektrische und optische
optique - Méthodes d'essais - Partie 100 : Généralités Verbindungselemente - Prüfverfahren - Teil 100:
Allgemeines
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee ASD-
STAN.

If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 2591-100:2022 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
oSIST prEN 2591-100:2022
prEN 2591-100:2022 (E)
Contents Page
European foreword . 3
1 Scope . 4
2 Normative references . 4
3 Terms and definitions . 5
4 Standard test conditions . 8
5 Test main requirements . 9
5.1 Fibre end preparation . 9
5.1.1 General. 9
5.1.2 Parameters . 9
5.1.3 Methods . 12
5.1.4 Specimen examination and acceptance . 12
5.1.5 Termination cleaning . 13
5.2 Light Launch System (LLS) . 13
5.2.1 General. 13
5.2.2 Generating the correct launch conditions . 14
5.2.3 Launch conditions specification for 62,5 µm/125 µm fibres and cables (NA = 0,275) . 15
5.2.4 Launch conditions specification for 50 µm/125 µm fibres and cables (NA = 0,2) . 18
5.3 Light Detection System (LDS) . 20
5.3.1 General. 20
5.3.2 Method . 21
5.3.3 Special precautions . 21
5.3.4 Documentation . 21
6 List of test methods . 21
7 Test report . 26
Bibliography . 27

2

---------------------- Page: 4 ----------------------
oSIST prEN 2591-100:2022
prEN 2591-100:2022 (E)
European foreword
This document (prEN 2591-100:2022) has been prepared by the Aerospace and Defence Industries
Association of Europe — Standardization (ASD-STAN).
After enquiries and votes carried out in accordance with the rules of this Association, this document has
received the approval of the National Associations and the Official Services of the member countries of
ASD, prior to its presentation to CEN.
This document is currently submitted to the CEN Enquiry.

3

---------------------- Page: 5 ----------------------
oSIST prEN 2591-100:2022
prEN 2591-100:2022 (E)
1 Scope
This document specifies the general requirements for the methods of testing elements of electrical,
optical and data transmission system connections used in aerospace applications.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 2083, Aerospace series — Copper or copper alloys conductors for electrical cables — Product standard
EN 2084, Aerospace series — Cables, electrical, general purpose, with conductors in copper or copper
alloy — Technical specification
EN 2234, Aerospace series — Cables, electrical, fire-resistant — Technical specification
1
EN 2346, Aerospace series — Fire resistant electrical cables — Dimensions, conductor resistance and
mass
EN 3745-201, Aerospace series — Fibres and cables, optical, aircraft use — Test methods — Part 201:
Visual examination
EN 4641-100, Aerospace series — Cables, optical 125 μm diameter cladding — Part 100: Tight structure
62,5/125 μm core GI fibre 1,8 mm outside diameter — Product standard
2
EN 4641-301, Aerospace series — Cables, optical 125 μm diameter cladding — Part 301: Tight structure
50/125 μm GI, fibre nominal 1,8 mm outside diameter — Product standard
EN 60512-1, Connectors for electronic equipment — Tests and measurements — Part 1: General
(IEC 60512-1:2001)
EN 60793-43, Optical fibres — Part 1-43: Measurement methods and test procedures — Numerical
aperture measurement (IEC 60793-43)
EN/IEC 60793-45, Optical fibres — Part 1-45: Measurement methods and test procedures — Mode field
diameter (IEC 60793-45)
3
IEC 60050-581, International Electrotechnical Vocabulary — Chapter 581: Electromechanical
components for electronic equipment
4
IEC 61300-3-35, Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 3-35: Examinations and measurements — Visual inspection of fibre optic
connectors and fibre-stub transceivers

1
Published as ASD-STAN Standard at the date of publication of this document by AeroSpace and Defence
industries Association of Europe — Standardization (ASD-STAN), https://www.asd-stan.org/.
2
Published as ASD-STAN Technical Report at the date of publication of this document by AeroSpace and
Defence industries Association of Europe — Standardization (ASD-STAN), https://www.asd-stan.org/.
3
Published by: IEC International Electrotechnical Commission https://www.iec.ch/.
4
Published by: IEC International Electrotechnical Commission https://www.iec.ch/.
4

---------------------- Page: 6 ----------------------
oSIST prEN 2591-100:2022
prEN 2591-100:2022 (E)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 60050-581, EN 60512-1 and
the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• ISO Online browsing platform: available at https://www.iso.org/obp
• IEC Electropedia: available at https://www.electropedia.org/
3.1
)
5
element of electrical or optical connection
component such as connector, module, etc., the purpose of which is to ensure the connection of circuits
3.2
flight cover (or protective cover)
accessory designed to ensure, in flight, mechanical protection and sealing of front face of a non-coupled
connector
3.3
connector with built-in protection of contacts
connector with characteristics such that male or female contacts, mounted in a plug or receptacle,
cannot come into contact with the front of the connector to which it is coupled (scoop-proof) and in
which, in the event of accidental coupling of two parts or the connector equipped with male contacts, no
electrical contact can take place
3.4
contact pressure point
point at which a square ended gauge pin of the same basic diameter as the mating contact first engages
the female contact spring member
3.5
initial measurement
examination or measurement of characteristics carried out to determine the magnitude of the
variations produced by the stress or stresses applied
This examination or measurement is carried out at the end of pre-conditioning and under normal
atmospheric conditions for measuring
3.6
final measurement
examination or measurement of characteristics carried out at the end of the recovery to assess the
condition of the specimen after testing and to determine the magnitude of the variations in
characteristics in relation to the values recorded at initial measuring
3.7
flammability
a product is considered to be “non-flammable” when combustion due to exposure for a given duration
to a standard external flame remains localized and stops spontaneously after withdrawal of the flame

5)
In test standards the term "element of connection" shall be used.
5

---------------------- Page: 7 ----------------------
oSIST prEN 2591-100:2022
prEN 2591-100:2022 (E)
3.8
fire resistance
a product is considered to be “fire-resistant” when, subjected to a standard flame:
— it retains its electrical role for six minutes;
— the flame does not propagate to the other side of the support in the first twenty minutes
3.9
values of alternating voltage and current
unless otherwise indicated, alternating voltage and current are indicated in root mean square values
3.10
line data bus
pair of twisted wires, shielded, having a specified impedance, a matched impedance at its two ends and
used for data transport
3.11
branch line
section of twisted wires, shielded, with a specified impedance, which connects equipment to a bus line
3.12
line coupler
element of electrical or optical connection the purpose of which is to shunt the transmission signals
from a bus line to equipment
3.13
line coupler, single
coupler consisting of one line and one branch
3.14
line coupler, double
coupler consisting of one line and two branches
3.15
in-line splice
permanent element of electrical or optical connection for two-wire cables
3.16
line termination
end line component the purpose of which is to match the bus line to its characteristic impedance
3.17
branch termination
end branch termination the purpose of which is to eventually replace equipment
3.18
recovery
treatment of a specimen, after conditioning, so that the properties of the specimen may be stabilized
before measuring
3.19
optical fibre cable
certain number of optical fibres or bundles, coated separately and joined inside a common sheath
6

---------------------- Page: 8 ----------------------
oSIST prEN 2591-100:2022
prEN 2591-100:2022 (E)
3.20
beam splitter
device for dividing an optical beam into two separate beams
3.21
insertion loss (of an optical element)
extra optical attenuation caused by the insertion of an extra optical element into an optical system
3.22
launch angle
angle between the wave propagation vector of the incoming light and the normal vector of an optic fibre
end face
3.23
mode conditioner
device for adapting the light output from a source to produce a defined launch condition for testing an
optical system
3.24
multimode fibre
optical fibre having a large core diameter dimension in relation to the wavelength of the light, and in
which a large number of modes can propagate
3.25
optical port
port which radiates or accepts optical power at the interface
3.26
fibre optic branching device
device possessing three or more optical ports which shares optical power among its ports in a
predetermined fashion
3.27
patch cord
assembly where the cable or fibre is terminated at each end with either a plug or socket connector
3.28
pigtail
short length of fibre between a component and a transmission fibre, often permanently secured to the
component (LED, coupler, connection elements, .)
3.29
power meter
device for measuring the optical power in a fibre optic system. Power measurements are usually made
in Watts or dBm. Relative power measurements are made in dB
3.30
single mode fibre
optical fibre in which only one mode can propagate
3.31
passive coupler
passive branching device in which power from one or more incoming optical ports is distributed to one
or more outgoing optical ports
7

---------------------- Page: 9 ----------------------
oSIST prEN 2591-100:2022
prEN 2591-100:2022 (E)
3.32
tee coupler
an optical fibre tee coupler is a passive coupler or combiner with three optical ports
3.33
return loss
light energy reflected back from discontinuities in a fibre optic link
3.34
light launch system
LLS
device designed to create defined and repeatable light coupling conditions in a test setup
3.35
light detection system
LDS
device designed to take repeatable measurements of light transmitted by a test setup
3.36
temporary joint
non-permanent optical fibre connecting devices for use on equipment
3.37
terminator
non-reflective termination of an optical fibre
3.38
test cord
terminated optical fibre cord used to connect the test equipment to the optical span, or to provide a
suitable interfaces to the cabling under test
3.39
for the following terms, see EN 3745-100
optical fibre – Core – Cladding – Primary coating – Refractive index profile – Step index fibre – Graded
index fibre – Quasi-step index fibre – Core diameter – Cladding diameter – Concentricity error
core/cladding – Non circularity of core – Non circularity of cladding – Attenuation – Numerical
aperture – Bandwidth
4 Standard test conditions
4.1 The test methods are written so that the test may be carried out either individually or included in
a test sequence.
4.2 Unless otherwise indicated in the test method, technical specification or product standard, the
test conditions shall be as follows:
— temperature: (23 ± 5) °C;
— atmospheric pressure: 86 kPa to 106 kPa (860 mbar to 1 060 mbar);
— relative humidity: 45 % to 75 %.
The temperature and humidity shall remain constant throughout a series of measurements.
8

---------------------- Page: 10 ----------------------
oSIST prEN 2591-100:2022
prEN 2591-100:2022 (E)
Unless otherwise indicated in the technical specification, the cables used for tests shall be in accordance
with EN 2083 and EN 2084 or EN 2234 and EN 2346.
5 Test main requirements
5.1 Fibre end preparation
5.1.1 General
The aim of this section is to give recommendations on the acceptable end condition of fibres, whether
terminated or not. It is not intended to describe a precise method for fibre end preparation; instead it
gives the information necessary to describe and quantify fibre end quality.
This paragraph is applicable therefore to all tests which require the use of at least one optical interface
of this type. It applies to all types of fibre, silica, plastic or a combination of these and other materials,
generally up to a diameter of 125 µm. Comments are made for some other fibre sizes.
5.1.2 Parameters
The quality of a fibre end can be described in terms of the end face profile and the surface condition.
These terms are now described in more detail.
5.1.2.1 End face profile
If terminated in a connector ferrule or contact, the fibre/ferrule end-face will be required to have a
particular profile depending on the application.
The most common connector profiles are listed below:
The connector end face profile will determine the connector insertion loss and return loss (back
reflection). Minimizing back reflection is of great importance in certain high-speed and analogue fibre
optic links to prevent instability at the source.
Flat Polish — As the name suggests the fibre interface is essentially flat. Usually produced with a very
hard backing material during polishing. A flat polish of the connector surface will result in a back
reflection of about −16 dB (4 %).
PC Polish — A Physical Contact (PC) polish results in a slightly curved connector surface, forcing the
fibre ends of mating connector pairs into physical contact with each other. This produces much lower
back reflection of −30 dB to −40 dB. The PC polish is the most prevalent connector end face in most
applications.
SPC and UPC Polish — Super PC (SPC) and Ultra PC (UPC) polished connectors are also curved and
physically contact. An extended polishing process enhances the surface quality of the connector,
resulting in back reflections of −40 dB to −55 dB and < −55 dB, respectively. These polish types are used
in high-speed, digital fibre optic transmission systems.
APC Polish — The Angled PC (APC) polish uses an 8 degree angle to the connector end face. Back
reflections of < −60 dB can routinely be accomplished with this type of polish.
For cases where the fibre is not terminated into a connector ferrule, it may be prepared as a nominally
flat interface. This may require cleaving to produce an acceptable end although polishing to a flat profile
is also possible (within a suitable bare fibre adapter). For cases where a ‘flat’ fibre end is to be produced
the flatness of the end-face should be good. In quantitative terms this can be defined in terms of end
face angle (see 5.1.2.2).
It is useful to describe the industry standard parameters for a PC (Physical Contact) profile. These are
shown in Figure 1. This profile is characterized typically by three key parameters namely,
(1) fibre/ferrule radius of curvature, (2) fibre height (undercut or protrusion with respect to the
9

---------------------- Page: 11 ----------------------
oSIST prEN 2591-100:2022
prEN 2591-100:2022 (E)
ferrule) and (3) polish offset (essentially the difference between the fibre centre and any higher polish
apex of the polished end-face. If the system under test has a particular fibre interface profile, then the
light launch system should also have a similar profile.

Key
1 fibre
2 polish apex
Figure 1 — PC parameters for a fibre connection (a) Radius of curvature, (b) Fibre undercut
(planar) (c) Fibre protrusion (planar) (d) Polish offset
The industry standards are typically as follows to ensure a good connection. Radius of curvature values
of between 10 mm to 30 mm are recommended to avoid fibre damage and to ensure low reflectance
and insertion loss. The fibre height specification value is related to specific radius of curvature but the
typical maximum values for undercut and protrusion are ± 50 nm. Fibre apex offset values should be
less than or equal to 50 µm.
5.1.2.2 Surface condition
The requirements of EN 3745-201 shall be applied.
The face of the optical fibre shall be free from large scratches, defects and cracks. For cleaved fibres the
face of the optical fibre shall not exhibit any nicking or lips and internal defects such as cracks. Some
slight chipping may be observed at the cleave point but if it does not extend to the core this should be
acceptable. Typically, a good cleave will have an end face angle of 0,25 degrees (a limit of 0,5 degrees is
sensible). Surface roughness is sometimes used to define condition of a surface. Typical maximum
values for fibre (and ferrule if connectorised) are 50 nm (defined by roughness parameters Ra and Rq).
10

---------------------- Page: 12 ----------------------
oSIST prEN 2591-100:2022
prEN 2591-100:2022 (E)
For connectorised fibres quantitative descriptions of allowable defect and scratch sizes for different
fibre types and sizes can be found in document IEC 61300-3-35. For the purposes of setting
requirements on end face quality the end face of the fibre is divided into measurement regions. These
are reproduced from IEC 61300-3-35 in Table 1. The standard goes on to specify allowable numbers
and sizes of features in each region. Note that, in this document, scratches are defined as permanent
linear features. Defects are all nonlinear features detectable on the fibre. This includes particulates and
other debris, pits, chips, edge chipping, etc.
Table 1 — Measurement regions for single fibre connectors (reproduced from IEC 61300-3-35)
Zone Diameter for single mode Diameter for multimode
A: core 0 µm to 25 µm 0 µm to 65 µm
B: cladding 25 µm to 120 µm 65 µm to 120 µm
C: adhesive 120 µm to 130 µm 120 µm to 130 µm
D: contact 130 µm to 250 µm 130 µm to 250 µm
NOTE 1 All data above assumes a 125 µm cladding diameter.
NOTE 2 Multimode core zone diameter is set at 65 µm to accommodate all common core
sizes in a practical manner.
NOTE 3 A defect is defined as existing entirely within the inner-most zone which it touches.
Table 2 — Example of visual requirements (allowable surface features and sizes) for multimode
single fibre connectors (reproduced from IEC 61300-3-35)
Zone name Scratches Defects
No limit ≤ 3 µm 4 ≤ 5 µm
A: core
0 > 5 µm None > 5 µm
No limit ≤ 2 µm
No limit ≤ 5 µm
B: cladding 5 from 2 µm to 5 µm
0 > 5 µm
None > 5 µm
C: adhesive No limit No limit
D: contact No limit None ≥ 10 µm
NOTE 1 For scratches, the requirement refers to width.
NOTE 2 No visible subsurface cracks are allowed in the core or cladding zones.
NOTE 3 All lose particles should be removed. If defects are non-removable, it should be
within the criteria above to be acceptable for use.
NOTE 4 There are no requirements for the area outside the contact zone since defects in
this area have no influence on the performance. Cleaning loose debris beyond this region is
recommended good practice.
NOTE 5 The zone size for multimode fibres has been set 65 µm to accommodate both 50 µm
and 62,5 µm core size fibres. This is done to simplify the grading process.
NOTE 6 Structural features that are part of the functional design of the optical fibre, such as
microstructures, are not considered defects.
11

---------------------- Page: 13 ----------------------
oSIST prEN 2591-100:2022
prEN 2591-100:2022 (E)
Table 3 — Example of visual requirements (allowable surface features and sizes) for low
reflectance (return loss > 45 dB) singlemode fibre optic connectors (reproduced from
IEC 61300-3-35)
Zone name Scratches Defects
A: core None None
No limit ≤ 2 µm
No limit ≤ 3 µm
B: cladding 5 from 2 µm to 5 µm
None > 3 µm
None > 5 µm
C: adhesive No limit No limit
D: contact No limit None ≥ 10 µm
NOTE 1 For scratches, the requirement refers to width.
NOTE 2 No visible subsurface cracks are allowed in the core or cladding zones.
NOTE 3 All lose particles should be removed. If defects are non-removable, it should be
within the criteria above to be acceptable for use.
NOTE 4 There are no requirements for the area outside the contact zone since defects in
this area have no influence on the performance. Cleaning loose debris beyond this region is
recommended good practice.
NOTE 5 Structural features that are part of the functional design of the optical fibre, such as
microstructures, are not considered defects.

To provide clarity for automated systems, scratches are defined as being less than 4 µm wide, linear in
nature, and with a length that is at least 30 times their width. Defects size is defined as the diameter of
the smallest circle that can encompass the entire defect.
An example of allowable features for a multimode connector is shown in Table 2. As can be seen, no
scratches or defects larger than 5 µm are allowed in the core region. In comparison for a low reflectance
single-mode connector (see Table 3), no scratches are allowed in the much smaller single-mode core.
The reader is referred to this document for inspection criteria for other fibre types such as higher
reflectance single-mode and also angle polished connectors.
5.1.3 Methods
Any method of fibre end preparation is acceptable provided that the parameters defined in 5.1.2 are
within the range specified for the fibre type and end profile required. For cleaved fibres (essentially
flat), cleaving tools are widely available to produce this profile by putting the fibre under tension and
then scribing the fibre so it breaks to produce a mirror-like finish.
Connectorised fibres are usually prepared by polishing the end face either by manual or mechanical
means.
5.1.4 Specimen examination and acceptance
Any method, optical or otherwise, which enables defects of the size quoted in 5.1.2 (or more generally
in the cited standard reference IEC 61300-3-35) to be assessed, shall be acceptable.
The methods may use systems which are as simple as a microscope with appropriate magnification for
the measurement or as sophisticated as an interferometric system for three-dimensional end face
analysis. For any optical inspection system factors such as field of view, optical resolution and contrast
will be important in being able to detect defects.
12

---------------------- Page: 14 ----------------------
oSIST prEN 2591-100:2022
prEN 2591-100:2022 (E)
For optical inspection (e.g. of surface condition) the simplest techniques may involve direct-view
microscopy with human measurement of observed features. Video microscopy may be used where the
image is displayed on a monitor (after being detected on a sensor or camera). Again measurement may
be made on that image with a calibrated measuring system. Automated microscopy systems are also
available that can reduce human subjectivity by performing digital image capture and software analysis
(with appropriate algorithms). Pass/Fail acceptance can be performed by the software.
For fibre profile measurement, interferometric (non-contact) systems are now commonly available to
routinely measure the end face profile of fibre optic connectors. These can measure and analyse
connectors quickly and display values for the key PC parameters. Again Pass/Fail
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.