Explosives for civil uses - Detonators and relays - Part 5: Determination of resistance to cutting damage of leading wires and shock tubes

This European Standard specifies a method for determining the resistance to failure of the plastic materials used in insulation of leading wires of electric detonators, or the tubing of shock tube non-electric detonators, when drawn over a sharp edge under specified loading conditions.

Explosivstoffe für zivile Zwecke - Zünder und Verzögerungselemente - Teil 5: Bestimmung der Widerstandsfähigkeit von Zünderdrähten und Zündschläuchen gegen Schnittbelastung

Explosifs a usage civil - Détonateurs et relais - Partie 5: Détermination de la résistance du fil d'amorçage et du tube a transmission d'ondes de choc aux dommages par coupes

Eksplozivi za civilno uporabo – Detonatorji in zakasnilniki – 5. del: Ugotavljanje odpornosti vodnikov in detonacijskih cevk proti urezu

General Information

Status
Published
Publication Date
31-Dec-2003
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Jan-2004
Due Date
01-Jan-2004
Completion Date
01-Jan-2004

Relations

Buy Standard

Standard
EN 13763-5:2004
English language
11 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Eksplozivi za civilno uporabo – Detonatorji in zakasnilniki – 5. del: Ugotavljanje odpornosti vodnikov in detonacijskih cevk proti urezuExplosivstoffe für zivile Zwecke - Zünder und Verzögerungselemente - Teil 5: Bestimmung der Widerstandsfähigkeit von Zünderdrähten und Zündschläuchen gegen SchnittbelastungExplosifs a usage civil - Détonateurs et relais - Partie 5: Détermination de la résistance du fil d'amorçage et du tube a transmission d'ondes de choc aux dommages par coupesExplosives for civil uses - Detonators and relays - Part 5: Determination of resistance to cutting damage of leading wires and shock tubes71.100.30Eksplozivi. PirotehnikaExplosives. PyrotechnicsICS:Ta slovenski standard je istoveten z:EN 13763-5:2003SIST EN 13763-5:2004en01-januar-2004SIST EN 13763-5:2004SLOVENSKI
STANDARD







EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13763-5November 2003ICS 71.100.30English versionExplosives for civil uses - Detonators and relays - Part 5:Determination of resistance to cutting damage of leading wiresand shock tubesExplosifs à usage civil - Détonateurs et relais - Partie 5:Détermination de la résistance du fil d'amorçage et du tubeà transmission d'ondes de choc aux dommages par coupesExplosivstoffe für zivile Zwecke - Zünder undVerzögerungselemente - Teil 5: Bestimmung derWiderstandsfähigkeit von Zünderdrähten undZündschläuchen gegen SchnittbelastungThis European Standard was approved by CEN on 7 September 2003.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and UnitedKingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2003 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13763-5:2003 E



EN 13763-5:2003 (E)2ContentspageForeword.3Introduction.51Scope.52Normative references.53Terms and definitions.54Apparatus.55Test pieces.86Procedure.97Test report.9Annex A (informative)
Range of applicability of the test method.10Annex ZA (informative)
Clauses of this European Standard addressing essential requirements or otherprovisions of EU Directives.11



EN 13763-5:2003 (E)3ForewordThis document (EN 13763-5:2003) has been prepared by Technical Committee CEN/TC 321 "Explosives for civiluses", the secretariat of which is held by AENOR.This European Standard shall be given the status of a national standard, either by publication of an identical text orby endorsement, at the latest by May 2004, and conflicting national standards shall be withdrawn at the latest byMay 2004.This document has been prepared under a mandate given to CEN by the European Commission and the EuropeanFree Trade Association, and supports essential requirements of EU Directive(s).For the relationship with EU Directive(s), see informative annex ZA, which is an integral part of this standard.This European Standard is one of a series of standards with the generic title Explosives for civil uses – Detonatorsand relays. The other parts of this series are listed below:prEN 13763-1Part 1: RequirementsEN 13763-2Part 2: Determination of thermal stabilityEN 13763-3Part 3: Determination of sensitiveness to impactEN 13763-4Part 4: Determination of resistance to abrasion of leading wires and shock tubesEN 13763-6Part 6: Determination of resistance to cracking at low temperatures of leading wiresEN 13763-7Part 7: Determination of the mechanical strength of leading wires, shock tubes, connections,crimps and closuresEN 13763-8Part 8: Determination of resistance to vibration of plain detonatorsEN 13763-9Part 9: Determination of resistance to bending of detonatorsEN 13763-11Part 11: Determination of resistance to damage by dropping of detonators and relaysEN 13763-12Part 12: Determination of resistance to hydrostatic pressureprEN 13763-13Part 13: Determination of resistance of electric detonators against electrostatic dischargeprEN 13763-15Part 15: Determination of equivalent initiating capabilityprEN 13763-16Part 16: Determination of delay accuracyprEN 13763-17Part 17: Determination of no-fire current of electric detonatorsprEN 13763-18Part 18: Determination of series firing current of electric detonatorsprEN 13763-19Part 19: Determination of firing impulse of electric detonatorsEN 13763-20Part 20: Determination of total electrical resistance of electric detonatorsprEN 13763-21Part 21: Determination of flash-over voltage of electric detonatorsprEN 13763-22Part 22: Determination of capacitance, insulation resistance and insulation breakdown of leadingwires



EN 13763-5:2003 (E)4EN 13763-23Part 23: Determination of the shock-wave velocity of shock tubesEN 13763-24Part 24: Determination of the electrical non-conductivity of shock tubesprEN 13763-25Part 25: Determination of transfer capability of surface connectors and coupling accessoriesprEN 13763-26Part 26: Definitions, methods and requirements for devices and accessories for reliable and safefunction of detonators and relaysCEN/TS 13763-27Part 27: Definitions, methods and requirements for electronic initiation systemsAnnex A is informative.According to the CEN/CENELEC Internal Regulations, the national standards organizations of the followingcountries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal,Slovakia, Spain, Sweden, Switzerland and the United Kingdom.



EN 13763-5:2003 (E)5IntroductionDuring usage on site, the insulation on the leading wires of electric detonators and the plastic tubing of shock tubeto be used in non-electric detonator ass
...