Thermal insulation products for buildings - In-situ formed loose fill cellulose (LFCI) products - Part 1: Specification for the products before installation

This European Standard specifies requirements for loose-fill cellulose insulation (LFCI) products for the thermal and/or sound insulation of buildings when installed into walls, floors, galleries, roofs and ceilings. This European Standard is a specification for the loose-fill cellulose insulation (LFCI) products before installation. This European Standard describes the product characteristics and includes procedures for testing, marking and labelling and the rules for evaluation of conformity. Products covered by this European Standard may also be used in prefabricated thermal insulation systems and composite panels; the structural performance of systems incorporating these products is not covered. Products with a declared thermal conductivity at 10 °C greater than 0,060 W/(m × K) or a declared thermal resistance lower than 0,25 m2 × K/W are not covered by this European Standard. This European Standard does not specify the required level of all properties to be achieved by a product to demonstrate fitness for purpose in a particular application. The required levels are to be found in local regulations or non-conflicting standards. This European Standard does not cover factory made cellulose products placed on the market as bats, mats or boards intended to be used for the insulation of buildings or loose-fill cellulose products for the insulation of building equipment and industrial installations.

Wärmedämmstoffe für Gebäude - An der Verwendungsstelle hergestellter Wärmedammstoff aus Zellulosefüllstoff (LFCI) - Teil 1: Spezifikation für die Produkte vor dem Einbau

Diese Europäische Norm legt Anforderungen für Produkte aus Zellulosefüllstoff (LFCI, en: Loose-Fill Cellulose Insulation) fest, die als Wärme- und/oder Schalldämmung von Gebäuden in Wände, Fußböden, Galerien, Dächer und Decken eingebaut werden.
Diese Europäische Norm ist eine Spezifikation für Wärmedämmprodukte aus Zellulosedämmstoff (LFCI) vor dem Einbau.
Diese Europäische Norm beschreibt die Produkteigenschaften und enthält Verfahren für die Prüfung, Kennzeichnung und Etikettierung sowie Festlegungen für die Konformitätsbewertung.
Die von dieser Europäischen Norm abgedeckten Produkte dürfen auch in vorgefertigten Wärmedämmsystemen und Mehrschicht-Verbundplatten verwendet werden; das Tragverhalten von Systemen, die diese Produkte enthalten, wird jedoch nicht behandelt.
Produkte mit einem Nennwert der Wärmeleitfähigkeit bei 10 °C von mehr als 0,060 W/(m  K) oder einem Nennwert des Wärmedurchlasswiderstands von weniger als 0,25 m2  K/W sind nicht Gegenstand dieser Europäischen Norm.
Diese Europäische Norm legt keine erforderlichen Leistungsstufen für die Eigenschaften fest, die ein Produkt für den Nachweis der Gebrauchstauglichkeit in einer bestimmten Anwendung erreichen muss. Die erforderlichen Stufen können örtlichen Regelwerken oder nicht entgegenstehenden Normen entnommen werden.
Diese Europäische Norm gilt weder für werkseitig hergestellte Zelluloseprodukte für die Wärmedämmung von Gebäuden, die in Form von Matten oder Platten in Verkehr gebracht werden, noch für Zellulosedämmstoff-produkte für die Wärmedämmung von haus- und betriebstechnischen Anlagen.

Produits isolants thermiques destinés aux applications du bâtiment - Isolation thermique formée en place à base de cellulose (LFCI) - Partie 1 : Spécification des produits en vrac avant la mise en oeuvre

La présente Norme européenne spécifie les exigences relatives aux produits d’isolation cellulosiques en vrac (LFCI) destinés à servir d’isolation thermique et/ou acoustique lorsqu'ils sont installés dans des parois, planchers, galeries, toitures et plafonds.
La présente Norme Européenne est une spécification des produits d'isolation cellulosiques en vrac (LFCI) avant la mise en place.
La présente Norme européenne décrit les caractéristiques des produits et inclut les modes opératoires pour les essais, le marquage et l'étiquetage, ainsi que les règles à respecter pour l'évaluation de la conformité.
Les produits concernés par la présente Norme européenne peuvent également être utilisés en systèmes préfabriqués d’isolation thermique et panneaux composites ; la performance structurelle des systèmes incorporant ces produits n’est pas couverte.
Les produits ayant une conductivité thermique à 10 °C (température moyenne) supérieure à 0,060 W/(m  K) ou une résistance thermique déclarée inférieure à 0,25 m2  K/W ne sont pas couverts par la présente Norme européenne.
La présente Norme européenne ne spécifie pas le niveau requis de toutes les propriétés que doit acquérir un produit pour démontrer son aptitude à l’emploi pour une application particulière. Les niveaux requis figurent dans les réglementations locales ou les normes qui ne sont pas en contradiction.
La présente Norme européenne ne couvre pas les produits cellulosiques fabriqués en usine et mis sur le marché sous forme de nattes, de matelas ou de panneaux destinés à être utilisés pour l’isolation de bâtiments ou les produits cellulosiques en vrac destinés à l’isolation des équipements du bâtiment et des installations industrielles.

Toplotnoizolacijski proizvodi za stavbe - Razsuti celulozni proizvodi (LFCI) za oblikovanje na mestu vgradnje - 1. del: Specifikacija za proizvode pred vgradnjo

Ta evropski standard določa zahteve za razsute celulozne izolacijske proizvode (LFCI) za toplotno in/ali zvočno izolacijo sten, tal, galerij, streh in stropov v zgradbah. Ta evropski standard je specifikacija za razsute celulozne izolacijske proizvode (LFCI) pred vgradnjo. Ta evropski standard opisuje lastnosti proizvoda in vključuje postopke za preskušanje, označevanje in etiketiranje ter pravila za ocenjevanje skladnosti. Proizvodi iz tega evropskega standarda se lahko uporabljajo tudi v predizdelanih sistemih toplotne izolacije in vezanih ploščah; strukturne lastnosti sistemov iz teh proizvodov niso opisane. Proizvodi z deklarirano toplotno prevodnostjo pri 10 °C, višjo od 0,060 W/(m×K), ali deklarirano toplotno upornostjo, nižjo od 0,25 m2×K/W, niso zajeti v tem evropskem standardu. Ta evropski standard ne določa zahtevane ravni vseh lastnosti, ki jo mora proizvod doseči, da se dokaže njegova primernost za namen v posamezni vrsti uporabe. Zahtevane ravni so določene v lokalnih uredbah ali standardih, ki niso v nasprotju s tem standardom. Ta evropski standard ne zajema tovarniških celuloznih proizvodov, ki so na voljo na trgu v obliki kopren, podlog ali plošč za izolacijo stavb, ali razsutih celuloznih proizvodov za izolacijo opreme stavb in industrijskih naprav.

General Information

Status
Withdrawn
Public Enquiry End Date
29-Apr-2013
Publication Date
08-Oct-2013
Withdrawal Date
13-May-2019
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
14-May-2019
Due Date
06-Jun-2019
Completion Date
14-May-2019

Relations

Buy Standard

Standard
EN 15101-1:2013
English language
64 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Toplotnoizolacijski proizvodi za stavbe - Razsuti celulozni proizvodi (LFCI) za oblikovanje na mestu vgradnje - 1. del: Specifikacija za proizvode pred vgradnjoWärmedämmstoffe für Gebäude - An der Verwendungsstelle hergestellter Wärmedammstoff aus Zellulosefüllstoff (LFCI) - Teil 1: Spezifikation für die Produkte vor dem EinbauProduits isolants thermiques destinés aux applications du bâtiment - Isolation thermique formée en place à base de cellulose (LFCI) - Partie 1 : Spécification des produits en vrac avant la mise en oeuvreThermal insulation products for buildings - In-situ formed loose fill cellulose (LFCI) products - Part 1: Specification for the products before installation91.100.60Thermal and sound insulating materialsICS:Ta slovenski standard je istoveten z:EN 15101-1:2013SIST EN 15101-1:2013en,fr,de01-november-2013SIST EN 15101-1:2013SLOVENSKI
STANDARD



SIST EN 15101-1:2013



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 15101-1
September 2013 ICS 91.100.60 English Version
Thermal insulation products for buildings - In-situ formed loose fill cellulose (LFCI) products - Part 1: Specification for the products before installation
Produits isolants thermiques destinés aux applications du bâtiment - Isolation thermique formée en place à base de cellulose (LFCI) - Partie 1 : Spécification des produits en vrac avant la mise en oeuvre
Wärmedämmstoffe für Gebäude - An der Verwendungsstelle hergestellter Wärmedammstoff aus Zellulosefüllstoff (LFCI) - Teil 1: Spezifikation für die Produkte vor dem Einbau This European Standard was approved by CEN on 8 August 2013.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15101-1:2013: ESIST EN 15101-1:2013



EN 15101-1:2013 (E) 2 Contents Page Foreword . 5 1 Scope . 6 2 Normative references . 6 3 Terms, definitions, symbols and abbreviations . 7 3.1 Terms and definitions . 7 3.2 Symbols . 8 3.3 Abbreviations . 9 4 Requirements . 9 4.1 General . 9 4.2 For all applications . 9 4.2.1 Thermal resistance and thermal conductivity . 9 4.2.2 Settlement . 10 4.2.3 Reaction to fire . 10 4.2.4 Durability . 10 4.3 For specific applications. 11 4.3.1 General . 11 4.3.2 Short-term water absorption. 11 4.3.3 Water vapour diffusion resistance factor . 11 4.3.4 Dangerous substances . 11 4.3.5 Corrosion resistance of the insulation material on certain metals . 11 4.3.6 Mould fungi resistance . 11 4.3.7 Airflow resistivity . 12 4.3.8 Continuous Glowing Combustion . 12 4.3.9 Sound absorption. 12 4.3.10 Reaction to fire of product in standardised assemblies simulating end-use applications . 12 5 Test methods . 13 5.1 Sampling . 13 5.2 Conditioning . 13 5.3 Testing . 13 5.3.1 General . 13 5.3.2 Thermal resistance and thermal conductivity . 15 6 Designation code . 15 7 Evaluation of conformity. 16 7.1 General . 16 7.2 Initial type testing . 16 7.3 Factory production control . 16 8 Marking and labelling . 16 Annex A (normative)
Determination of declared thermal resistance and thermal conductivity . 17 A.1 General . 17 A.2 Input data . 17 A.3 Declared values of thermal resistance and thermal conductivity . 17 Annex B (normative)
Laboratory methods for the determination of settlement . 19 B.1 Blown LFCI for ventilated attics (open blow) — determination of settlement under cyclic humidity . 19 B.1.1 Principle. 19 B.1.2 Apparatus . 19 B.1.3 Test specimens . 19 B.1.4 Test procedure . 19 SIST EN 15101-1:2013



EN 15101-1:2013 (E) 3 B.1.5 Test report . 21 B.2 Blown LFCI in timber and steel framed walls – determination of settlement under vibrations . 21 B.2.1 Principle . 21 B.2.2 Apparatus . 21 B.2.3 Test specimen . 23 B.2.4 Procedure . 23 B.2.5 Calculation and expression of test results. 24 B.2.6 Accuracy of measurements . 24 B.2.7 Test report . 24 B.3 Blown LFCI for ventilated attics — determination of settlement under impact excitation and under increased temperature and moisture (informative and for FPC only) . 25 B.3.1 Principle . 25 B.3.2 Apparatus . 25 B.3.3 Test specimens . 26 B.3.4 Test procedure . 27 B.3.5 Calculations and expression of results . 27 B.3.6 Test report . 28 Annex C (normative)
Testing for reaction to fire of products . 30 C.1 Scope . 30 C.1.1 General . 30 C.1.2 Product and installation parameters . 30 C.1.3 Ignitability (EN ISO 11925-2) . 31 C.1.4 Single Burning Item [SBI] (EN 13823) for loose-fill cellulose insulation products . 32 Annex D (normative)
Specimen preparation method for the water absorption test . 36 D.1 Principle . 36 D.2 Conditioning . 36 D.3 Procedure . 36 Annex E (normative)
Method of test for corrosion resistance . 37 E.1 Principle . 37 E.2 Conditioning . 37 E.3 Reagents and materials . 37 E.4 Apparatus . 37 E.5 Procedure . 38 E.6 Classification of the results . 38 E.7 Report . 38 Annex F (normative)
Method for determining mould fungi resistance . 39 F.1 Scope . 39 F.2 Significance and use . 39 F.3 Apparatus . 39 F.4 Reagents and materials . 39 F.4.1 Water . 39 F.4.2 Inoculum . 40 F.5 Specimens . 40 F.5.1 Viability control specimens . 40 F.5.2 Comparative material . 40 F.5.3 Test specimens . 40 F.6 Procedure . 40 F.6.1 Spore suspension . 40 F.6.2 Inoculation of test specimens, comparative material and control specimens . 41 F.6.3 Incubation . 41 F.7 Test analysis . 41 F.7.1 General . 41 F.7.2 Validation . 42 F.7.3 Classification . 42 F.8 Report . 42 F.9 Precision and bias . 42 SIST EN 15101-1:2013



EN 15101-1:2013 (E) 4 Annex G (normative)
Specimen preparation method for the airflow resistance test . 43 G.1 Principle. 43 G.2 Procedure . 43 Annex H (normative)
Specimen preparation method for thermal resistance and thermal conductivity test . 44 H.1 Principle. 44 H.2 Procedure . 44 H.2.1 Horizontal applications, loft and floors . 44 H.2.2 Cavity insulation, frame constructions and cavity walls . 45 Annex I (normative)
Factory production control . 47 Annex J (normative)
Testing for reaction to fire of products in standardised assemblies simulating end-use application(s) . 50 J.1 Scope . 50 J.2 Product and installation parameters . 50 J.3 Mounting and fixing . 51 J.3.1 Ignitability (EN ISO 11925-2) . 51 J.3.2 Single Burning Item [SBI] (EN 13823) . 51 J.4 Field of application . 54 Annex K (normative)
An example of a performance chart . 56 Annex ZA (informative)
Clause of this European Standard addressing the provisions of the EU Construction Products Directive . 57 ZA.1 Scope and relevant characteristics . 57 ZA.2 Procedure for attestation of conformity of in situ formed loose-fill cellulose . 59 ZA.2.1 System(s) of attestation of conformity . 59 ZA.2.2 EC Certificate and Declaration of conformity . 61 ZA.3 CE marking and labelling . 62 Bibliography. 64
SIST EN 15101-1:2013



EN 15101-1:2013 (E) 5 Foreword This document (EN 15101-1:2013) has been prepared by Technical Committee CEN/TC 88 “Thermal insulating materials and products”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by March 2014, and conflicting national standards shall be withdrawn at the latest by March 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. This European Standard consists of two parts which form a package. The first part is the harmonised part satisfying the mandate and the CPD and is the basis for the CE marking covering the products, which are placed on the market. The second part, which is the non-harmonised part, covers the installation checks for the installed products.
This European Standard is one of a series for mineral wool, expanded clay, expanded perlite, exfoliated vermiculite, polyurethane/polyisocyanurate, cellulose, bound expanded polystyrene and expanded polystyrene in-situ formed insulation products used in buildings, but this standard may be used in other areas where appropriate. The reduction in energy used and emissions produced during the installed life of insulation products exceeds by far the energy used and emissions made during the production and disposal processes. According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 15101-1:2013



EN 15101-1:2013 (E) 6 1 Scope This European Standard specifies requirements for loose-fill cellulose insulation (LFCI) products for the thermal and/or sound insulation of buildings when installed into walls, floors, galleries, roofs and ceilings. This European Standard is a specification for the loose-fill cellulose insulation (LFCI) products before installation. This European Standard describes the product characteristics and includes procedures for testing, marking and labelling and the rules for evaluation of conformity. Products covered by this European Standard may also be used in prefabricated thermal insulation systems and composite panels; the structural performance of systems incorporating these products is not covered. Products with a declared thermal conductivity at 10 °C greater than 0,060 W/(m × K) or a declared thermal resistance lower than 0,25 m2 × K/W are not covered by this European Standard. This European Standard does not specify the required level of all properties to be achieved by a product to demonstrate fitness for purpose in a particular application. The required levels are to be found in local regulations or non-conflicting standards. This European Standard does not cover factory made cellulose products placed on the market as bats, mats or boards intended to be used for the insulation of buildings or loose-fill cellulose products for the insulation of building equipment and industrial installations. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 312, Particleboards - Specifications EN 508-1, Roofing products from metal sheet — Specification for self-supporting products of steel, aluminium or stainless steel sheet — Part 1: Steel EN 520, Gypsum plasterboards — Definitions, requirements and test methods EN 1609, Thermal insulating products for building applications — Determination of short term water absorption by partial immersion EN 12086:2013, Thermal insulation products for building applications — Determination of water vapour transmission properties EN 12667, Thermal performance of building materials and products — Determination of thermal resistance by means of guarded hot plate and heat flow meter methods — Products of high and medium thermal resistance EN 13172:2012, Thermal insulating products — Evaluation of conformity EN 13238, Reaction to fire tests for building products — Conditioning procedures and general rules for selection of substrates EN 13501-1, Fire classification of construction products and building elements — Part 1 Classification using data from reaction to fire tests EN 13823:2010, Reaction to fire tests for building products — Building products excluding floorings exposed to the thermal attack by a single burning item SIST EN 15101-1:2013



EN 15101-1:2013 (E) 7 EN 29053, Acoustics — Materials for acoustical applications — Determination of airflow resistance (ISO 9053) EN ISO 354:2003, Acoustics — Measurement of sound absorption in a reverberation room (ISO 354:2003) EN ISO 10456 Building materials and products — Hygrothermal properties — Tabulated design values and procedures for determining declared and design thermal values (ISO 10456) EN ISO 11654, Acoustics — Sound absorbers for use in buildings — Rating of sound absorption (ISO 11654) EN ISO 11925-2, Reaction to fire tests — Ignitability of building products subjected to direct impingement of flame — Part 2: Single-flame source test (ISO 11925-2) ISO 12491, Statistical methods for quality control of building materials and components 3 Terms, definitions, symbols and abbreviations
3.1 Terms and definitions
For the purposes of this document, the following terms and definitions apply. 3.1.1 open blow applications all applications except cavity applications 3.1.2 declared insulation thickness: “open blow” applications installed insulation thickness minus the thickness loss according to the settlement class of the product 3.1.3 declared insulation thickness: cavity applications identical with the thickness of the cavity 3.1.4 floor horizontal division between two storeys, over a crawl space or a floor directly on the ground 3.1.5 frame construction walls with wood or metal studs, sloping roof with insulation between and above rafters, as well as stud girders and internal and external insulation on solid masonry construction 3.1.6 settlement decrease of installed insulation thickness in lofts or height in cavities and frame constructions either under vibration, humidity, cyclic conditions and time, expressed as a percentage of the initial installed insulation thickness (after compaction if required) 3.1.7 coverage mass of insulation per unit area 3.1.8 performance chart table giving thickness and coverage requirements for different values of declared thermal resistance SIST EN 15101-1:2013



EN 15101-1:2013 (E) 8 3.1.9 class combination of two levels of the same property between which the performance is to fall where the levels are given by the declared value of the characteristic concerned 3.1.10 loose-fill cellulose insulation (LFCI) fibre, fibrous or granulated insulation material derived from paper, paper stock and/or wood, leave or stalk strings with or without binders which are blown, injected or applied with or without
...