SIST EN 1279-6:2004
(Main)Glass in building - Insulating glass units - Part 6: Factory production control and periodic tests
Glass in building - Insulating glass units - Part 6: Factory production control and periodic tests
This draft European Standard is the product standard for insulating glass units, which defines insulating glass units, and ensures by means of an adequate evaluation of conformity to this standard that: - energy savings are made because the U-value and solar factor do not change significantly; - health because sound reduction and vision do not change significantly; - safety is provided because mechanical resistance does not change significantly.
Glas im Bauwesen - Mehrscheiben-Isolierglas - Teil 6: Werkseigene Produktionskontrolle und Auditprüfungen
Diese europäische Norm ist die Produktnorm für Mehrscheiben-Isoliergläser, die Mehrscheiben-Isoliergläser definiert und durch eine adäquate Bewertung deren Übereinstimmung mit dieser Norm sicherstellt, dass:
3 Energieeinsparungen erzielt werden, da keine signifikanten Änderungen des U-Werts und des Solarfaktors auftreten;
3 die Gesundheitsvorsorge gefördert wird, da keine signifikanten Änderungen der Schalldämmung und der Durchsicht auftreten;
3 der Sicherheit gedient wird, da keine signifikanten Änderungen der mechanischen Beständigkeit auftreten.
Diese europäische Norm deckt zusätzliche Merkmale ab, die für den Handel von Bedeutung sind. Die Bedingungen für die Kennzeichnung werden ebenfalls erfasst.
Bei Glasprodukten mit elektrischer Verkabelung oder elektrischen Anschlüssen, z. B. für Alarmanlagen oder Heizsysteme, gilt diese Norm nur für Verkabelungen mit einem elektrischen Potentialunterschied zur Erde von weniger als 50 V Wechselstrom oder weniger als 75 V Gleichstrom.
Der Haupteinsatzbereich der Mehrscheiben-Isoliergläser sind Fenster, Türen, Vorhangfassaden, Dachkonstrukti-onen und Trennelemente, deren Kanten gegen direkte UV-Strahlung geschützt sind.
ANMERKUNG 1 Falls die Kanten nicht gegen direkte UV-Strahlung geschützt sind, wie z. B. bei geklebten lastabtragenden Glaskonstruktionen, sind zusätzliche europäische technische Spezifikationen zu befolgen (siehe Literaturhinweise [4] und [5]).
ANMERKUNG 2 Mehrscheiben-Isoliergläser rein künstlerischer Natur werden von dieser Norm nicht erfasst.
Dieser Teil der Norm, der nur in Verbindung mit den anderen Teilen der Norm gilt, umfasst die routinemäßige werkseigene Produktionskontrolle (Anhang A), die Auditprüfung (Anhang B) und die Fogging-Prü-fung (Anhang C), um zu verifizieren, dass die Produktion und das Produkt der Systembeschreibung entsprechen.
Verre dans la construction - Vitrage isolant préfabriqué scellé - Partie 6 : Contrôle de production en usine et essais périodiques
La présente Norme européenne est la norme de produit pour le vitrage isolant préfabriqué scellé qui définit les éléments de vitrage isolants et garantit, par le biais d'une évaluation adéquate de la conformité a la présente norme que, a terme :
3 des économies d'énergie sont réalisées du fait que le coefficient U et le facteur solaire ne changent pas de façon significative ;
3 la santé est préservée du fait que l'atténuation sonore et la vision ne changent pas de façon significative ;
3 la sécurité est assurée du fait que la résistance mécanique ne change pas de façon significative.
Cette norme traite en outre de certaines caractéristiques additionnelles qui ont de l'importance dans les échanges commerciaux. Elle comprend des conditions de marquage.
Pour les produits de verre comportant des câblages ou raccords électriques, par exemple pour des systemes d'alarme ou de chauffage, cette norme ne traite que des câblages susceptibles de faire l'objet d'une différence de potentiel électrique par rapport a la terre de moins de 50 V c.a. ou de moins de 75 V c.c.
Les principales utilisations prévues des éléments de vitrage isolants sont les installations dans les bâtiments et les constructions telles que fenetres, portes, murs rideaux, toits et parois de séparation ou il existe une protection périphérique contre le rayonnement ultraviolet direct.
NOTE 1 Lorsqu'il n'y a pas de protection périphérique contre le rayonnement ultraviolet direct, comme dans le cas des systemes de vitrage a mastic de scellement structurel, il convient de suivre les prescriptions techniques européennes supplémentaires.
NOTE 2 Les éléments de nature purement décorative ne font pas partie de la présente norme.
Cette partie de la norme, qui est intimement liée aux autres parties de la norme, traite des contrôles de routine de la production en usine (annexe A), des essais et contrôles périodiques (annexe B) et des essais de condensation (annexe C) afin de vérifier que la production est conform
Steklo v stavbah – Izolacijski stekleni elementi – 6. del: Kontrola proizvodnje v tovarni in periodični preskusi
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Glas im Bauwesen - Mehrscheiben-Isolierglas - Teil 6: Werkseigene Produktionskontrolle und AuditprüfungenVerre dans la construction - Vitrage isolant préfabriqué scellé - Partie 6 : Contrôle de production en usine et essais périodiquesGlass in building - Insulating glass units - Part 6: Factory production control and periodic tests81.040.20Steklo v gradbeništvuGlass in buildingICS:Ta slovenski standard je istoveten z:EN 1279-6:2002SIST EN 1279-6:2004en01-september-2004SIST EN 1279-6:2004SLOVENSKI
STANDARD
SIST EN 1279-6:2004
EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 1279-6July 2002ICS 81.040.20English versionGlass in building - Insulating glass units - Part 6: Factoryproduction control and periodic testsVerre dans la construction - Vitrage isolant préfabriquéscellé - Partie 6: Contrôle de production en usine et essaispériodiquesGlas im Bauwesen - Mehrscheiben-Isolierglas - Teil 6:Werkseigene Produktionskontrolle und AuditprüfungenThis European Standard was approved by CEN on 5 March 2002.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2002 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 1279-6:2002 ESIST EN 1279-6:2004
EN 1279-6:2002 (E)2ContentspageForeword 31Scope 32Normative references 43Terms and definitions 44Quality assurance and factory production control 55Factory production control requirements 56Handling, storage, packaging and delivery 87Training of personnel 9Annex A (normative) Inspection and testing tables of insulating glass units 9Annex B(normative)Periodic testing and inspections45Annex C(normative)Fogging test49Annex D(informative)Two component sealants, check on the thoroughness of mixing55Annex E(informative)Sealants, hardness measurements57Annex F(informative)Seals, adherence measurements60Annex G(informative)Volatile test64Annex H(informative)Tightness check of hollow spacer closed by welding on the back65Annex J(informative)Adhesion test for leaded light strip66Annex K(informative) Desiccant, adsorption capacity check68Bibliography69SIST EN 1279-6:2004
EN 1279-6:2002 (E)3ForewordThis document EN 1279-6:2002 has been prepared by Technical Committee CEN/TC 129"Glass in building", the secretariat of which is held by IBN.This European Standard shall be given the status of a national standard, either by publicationof an identical text or by endorsement, at the latest by January 2003, and conflicting nationalstandards shall be withdrawn at the latest by January 2003.The described testing and inspections are part of routine production of insulating glass units.This Part of the standard does not stand alone, it is part of one standard:–prEN 1279-1, Glass in building - Insulating glass units - Part 1: Generalities, dimensionaltolerances and rules for the system description.–prEN 1279-2, Glass in building - Insulating glass units - Part 2: Long term test methodand requirements on moisture vapour penetration.–prEN 1279-3, Glass in building - Insulating glass units - Part 3: Long term test methodand requirements for gas leakage rate and for gas concentration tolerances.–EN 1279-4, Glass in building - Insulating glass units - Part 4: Methods of test for thephysical attributes of edge seals.–prEN 1279-5, Glass in building - Insulating glass units - Part 5: Evaluation of conformity.–EN 1279-6, Glass in building - Insulating glass units - Part 6 Factory production controland periodic tests.The annexes A, B and C are normative. The annexes D, E, F, G, H, J and K are informative.This standard includes a Bibliography.According to the CEN/CENELEC Internal Regulations, the national standards organizationsof the following countries are bound to implement this European Standard: Austria, Belgium,Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy,Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and theUnited Kingdom.1ScopeThis European Standard is the product standard for insulating glass units, which definesinsulating glass units, and ensures by means of an adequate evaluation of conformity to thisstandard that over time:–energy savings are made because the U-value and solar factor do not change significantly;–health is preserved because sound reduction and vision do not change significantly;–safety is provided because mechanical resistance does not change significantly.It covers additional characteristics that are of importance for trade. Marking conditions areincluded.SIST EN 1279-6:2004
EN 1279-6:2002 (E)4For glass products with electrical wiring or connections for e.g. alarm or heating purposes,this standard covers only wiring subject for electrical potential difference to earth less than50 V a.c. or less than 75 V d.c.The main intended uses of the insulating glass units are installations in buildings andconstructions such as in windows, doors, curtain walling, roofs and partitions where thereexists protection against direct ultraviolet radiation at the edges.NOTE 1
In cases where there is no protection against direct ultraviolet radiation at the edges, such as structuralsealant glazing systems, additional European technical specifications should be followed.NOTE 2
Units where the nature is only artistic are not part of this standard.This Part of the standard, which is inextricably bound up with the other Parts of the standard,covers the routine factory production control (annex A), the periodic testing and inspection(annex B) and fogging test (annex C) to verify that production conforms with the systemdescription.2Normative referencesThis European Standard incorporates, by dated or undated reference, provisions from otherpublications. These normative references are cited at the appropriate places in the text and thepublications are listed hereafter. For dated references, subsequent amendments to or revisionsof any of these publications apply to this European Standard only when incorporated in it byamendment or revision. For undated references, the latest edition of the publication referredto applies (including amendments).prEN 1279-1, Glass in building - Insulating glass units - Part 1: Generalities, dimensionaltolerances and rules for the system description.prEN 1279-2, Glass in building - Insulating glass units - Part 2: Long term test method andrequirements on moisture vapour penetration.prEN 1279-3, Glass in building - Insulating glass units - Part 3: Long term test method andrequirements for gas leakage rate and for gas concentration tolerances.EN 1279-4, Glass in building - Insulating glass units - Part 4: Methods of test for thephysical attributes of edge seals.EN 10204, Metallic products - Types of inspection documents.prEN 13022, Glass in building - Structural sealant glazing.3Terms and definitionsFor the purposes of this European Standard, the terms and definitions in prEN 1279-1 apply,as well as the following terms and definitions.3.1factory production controlpermanent control of production exercised by the manufacturer. All the elements,requirements and provisions adopted by the manufacturer are documented in a systematicmanner in the form of written policies and procedures. This production controldocumentation system ensures a common understanding of quality assurance and enable theSIST EN 1279-6:2004
EN 1279-6:2002 (E)5achievement of the required product characteristics and the effective operation of theproduction control to be checked3.2information from the supplierinformation which is based on periodic measurements and on the fact that the supplieroperates a quality assurance system which ensures that no significant deviations occurbetween measurements. See 5.2.63.3lotamount of products of a continuous production run, which can be a fixed number (e.g. 5, 100,3 000) or manufactured in a fixed interval (e.g. 1 hour, half a day, a shift, one day)3.4periodic testsseries of tests for checking the continuing conformity of the product with the technicalspecifications4Quality assurance and factory production controlA manufacturer operating under a third party surveillance Quality Assurance Systemaccording to EN ISO 9001 (Bibliography [4]), in which the quality procedures cover to therelevant annex(es) of this Part of the standard has the benefit of being presumed to complywith this EN 1279-6.5Factory production control requirements5.1Organisation5.1.1Responsibility and authorityThe responsibility, authority and the interrelation of all personnel who manage, perform andverify work affecting quality shall be defined, particularly for personnel who need theorganizational freedom and authority to:a)initiate action to prevent the occurrence of product non-conformity;b)identify and record any product quality problems.5.1.2Management representative for factory production controlAt every factory unit, where the insulating glazing units are manufactured, the manufacturershall appoint a person who shall have defined authority, appropriate knowledge andexperience of the production of the insulating glass, to be responsible for the conduct andsupervision of factory production control procedures, including assessment of thequalifications of any subcontracted testing and inspection body.SIST EN 1279-6:2004
EN 1279-6:2002 (E)6NOTE
Accreditation to EN 45000 series would be a sufficient but not a necessary qualification for such a body(see Bibliography [1], [2] and [3]).It will also be the responsibility of the appointed person to ensure that the requirements givenin this standard are implemented and maintained.5.1.3Management reviewThe production control system shall be reviewed at appropriate intervals by themanufacturer's management staff to ensure its continuing suitability and effectiveness inrespect to this Part of the standard. Records of such reviews shall be maintained.5.2Quality system5.2.1GeneralThe manufacturer shall establish and maintain a documented system as a means of ensuringthat the product conforms to this standard. The following requirements hereafter shall befulfilled.5.2.2PersonnelThe manufacturer shall appoint personnel for the inspections and production control tests thatwill be carried out before, during and after production (e.g. incoming materials), or themanufacturer can subcontract to a testing or inspection body.5.2.3DocumentationThe manufacturer's documentation and procedures shall be relevant to the production andprocess control of the insulating glass unit, and in this quality manual and associateddocumentation shall describe adequately the following:a)the quality aims and the organizational structure, responsibilities and powers of themanagement, especially the management representative for the factory production control,with regard to product conformity;b)the procedures for specifying and verifying the raw and constituent materials orcomponents;c)the product, the production control and other techniques, processes and systematic actionsthat will be used;d)the inspections and tests that will be carried out before, during and after production, andthe frequency with which they will be carried out;e)provisions for defining, keeping and using the records of the results of inspections andtests;f)the test reports in accordance with all other relevant Parts of this standard;g)the provisions taken for control of products that fail the specified criteria;h)documents of conformity made available by suppliers.SIST EN 1279-6:2004
EN 1279-6:2002 (E)7The documents shall be maintained during a period which shall be laid down in the qualitymanual. Records may be in the form of any type of media, such as hard copy or electronic,e.g. by means of a declaration in accordance with EN 10204.5.2.4Test equipmentTest equipment necessary for factory production control shall be calibrated as described in thequality manual.NOTE
The precision of calibration required is implied by the accuracy of the test method and tolerancesspecified.5.2.5 Inspection and testingInspection and testing depends on the design of the insulating glass units. The differentinspection and testing schemes are described in the annex A and annex B.Annex A details the inspection and tests: the requirements and the records are normative, thefrequency and test methods are recommended and therefore only given as information. Thoserecommended frequencies are sufficient for production. If no testing scheme, method orfrequency is described in the annex A, and/or another testing scheme is used, it shall bedescribed in detail in the quality manual.Annex B describes the periodic, low frequency test.Annex C describes the fogging test.Annex D onwards describes the tests referred to in annex A as recommendations.5.2.6Quality contractsInspection and tests on incoming materials (the Material control part of the tables in theAnnex A) can be reduced on the basis of quality contracts between the supplier and theinsulating glass unit manufacturer, on condition that the contract refers to the appropriatetables in annex A.Quality contracts shall include the possibility of an audit of the supplier.The quality contracts can also include the documents demonstrating conformity to thisEuropean Standard. If so, and supplying manufacturers who comply with EN ISO 9001, theinspection and tests on incoming material may be further reduced, so that the inspection andtests are not unnecessarily duplicated.Where contractually requested, quality records shall be made available by suppliers forevaluation by the customer's representative for an agreed period.SIST EN 1279-6:2004
EN 1279-6:2002 (E)86Handling, storage, packaging and deliveryThe manufacturer shall establish, document and maintain procedures for handling, storage,packaging and delivery of the insulating glass units. The procedure shall be adequate toguarantee the quality of the product.Delivered individual products or product batches shall be identifiable and traceable withregard to their production data. For this purpose, the manufacturer shall establish andmaintain the records required in the relevant technical specification, and shall mark theinsulating glass units or their delivery documents correspondingly.7Training of personnelThe manufacturer shall establish and maintain procedures for the training of all personnelactivities affecting quality. Personnel performing specific assigned tasks shall be qualified onthe basis of appropriate education training and/or experience, as required. Appropriate recordsof training shall be maintained.SIST EN 1279-6:2004
EN 1279-6:2002 (E)9Annex A(normative)Inspection and testing tables of insulating glass unitsA.1GeneralThe tables in A.2 onwards in this annex deal with particular design of insulating glass units.When a modified or new design cannot find tables fitting with its production method,appropriate tables shall be defined. These new tables can be incorporated in the standardwhen revision of the standard takes place.NOTE 1
In the meantime, a CEN report containing the draft new tables can be elaborated, so that placing theproduct on the market may proceed without interruption.Each of A.2 till A.7 in this annex onwards, dealing with a particular design, consists of twoparts: additional definitions related to the specific design, and a table containing threesections:–first section: Material control;–second section: Production Control;–third section: Product control.Due to the nature of products used, it is reasonable to carry out some tests simultaneously online. This is acceptable providing sufficient controls are incorporated into the system to allowchange/replacement if a test failure occurs.Some inspections in the product control section can be, and therefore may be performedduring production (e.g the determination of the intended thickness of sealant on the back ofthe spacer can be performed during placing the spacer onto the glass). In those cases, and toprevent duplication of inspections, the production control documentation shall contain therelevant instructions.The product control section of the tables refer to a random sample inspection plan. Thatinspection plan is a recommended plan. See Table A.1 in NOTE 2. Use of this plan, or planswith the same statistical accuracy (e.g. based on ISO 2859, Bibliography [6]) can be helpfulfor passing successfully periodic inspections by independent bodies.SIST EN 1279-6:2004
EN 1279-6:2002 (E)10NOTE 2Table A.1 - Recommended random sample inspection plan for finishedinsulating glass units (decision is to be made by the manufacturer)Lot or day'sproductionNumber of test pieces forinspectionsMaximum number of units fallingoutside the system description2 – 152016 – 253026 – 905091 – 15081151 – 500131501 – 1 2002021 201 – 9 999323To be effective, Table A.1 should be used in the following way. When the inspection of a lot or a day'sproduction reveals more than the acceptable number of occurrences which exceed the absolute limits describedin the system description (for the rules of the system description, see prEN 1279-1), all the units of the lot orday's production should be re-inspected. Any units which exceed the absolute limit(s) should be repaired or re-manufactured. Decision is to be made by the manufacturer.SIST EN 1279-6:2004
EN 1279-6:2002 (E)11A.2Air filled organic sealed insulating glass units with hollow spacerThe listed inspections and tests relate to organic sealed (without hot melt butyl as outer seal)air-filled insulating glass units with hollow spacer. Figure 1 gives the principle of this systemof insulating glass units.Key1
Desiccant2
Spacer bar3
Diffusion openings4
Glass5
Inner seal6
Outer sealFigure A.1 - A principle of an organic sealed insulating glass units with hollow spacerWhen a manufacturing process is such that one or more of the listed inspections or tests arenot applicable or physically not possible, the relevant inspection or test shall be ignored.The inspections and/or tests on the raw materials should be carried out in time to react in thecase of non-conformance of the material.Volatile content tests are only to be carried out if the cavity of the unit is in contact with amaterial with a volatile content so high that condensation can occur, and if there is noinformation from the supplier that the volatile content is below a certain limit. This limit isdefined as 1,5 times the value for the volatile content of the material for use in construction ofthe samples which were prepared for the fogging test, and when the same adequate heatingprocedure is used for both. For the volatile test parameters, see annex G. In connection withthe volatile contents in Table A.2, one has to read "recommended limits" instead of"requirements".SIST EN 1279-6:2004
EN 1279-6:2002 (E)12No volatile content test is required when fogging tests are carried out.The required records in the following tables can be any documents such as order documents,production documents, logbook, etc. as described in the quality procedures and associateddocumentation. When no record is required, this is valid only if there are no complaints. Incase of complaint, records shall always be kept.Adjustments of machinery and equipment used for manufacturing insulating glass units areperiodically checked according to defined parameters for optimum results, and/or accordingto the recommendations of the manufacturer or the supplier of the machinery or equipmentand in any case when non conformity of the products occurs.SIST EN 1279-6:2004
EN 1279-6:2002 (E)13Table A.2 - Inspection and test table for air-filled organic sealed insulating glass units with hollow spacer (continued)Section 1: Material Control (See also 5.2.6)Ref.Material, inspection or testRecommended method(decision to be made bymanufacturer)RequirementRecommended frequency(decision to be made by manufacturer)Record1
Glass1.1packaging and labelVisualSee purchase specificationEach batch: 1No1.2identification (glass/coated glass, according to relevant standards)VisualSee purchase specificationEach batchYes1.3dimensions (length/width/shape when applicable)MeasurementSee purchase specificationEach batch, package and thickness: 1No2
Spacer bar:2.1packaging and labelVisualSee purchase specificationEach batch: 1No2.2straightnessVisualSee purchase specificationEach batch: 2No2.3dimensions (height, width)MeasurementSee purchase specificationEach batch: 1 samples/typeYes2.4shapeVisualsee purchase specificationeach batch: 1 sample/typeNo2.5surface conditionAdhesion test (e.g. annex F.)See product descriptionEach batch: 2 samples/typeYes2.6diffusion openingsVisualSee product descriptionPer shift and per type: 1 (See note 1)No2.7undesired openings (if relevant e.g. welded on back)Visual (see annex H)No openings2 samples of the amount used per shiftYes2.8volatile content (if no information from supplier is available)Weight lossSee purchase specificationEach batch: 2 samples/typeYes3
Spacer tape:3.1packaging and labelVisualSee purchase specificationEach batch: 1No3.2dimensionsMeasurementSee purchase specificationEach batch: 2 samples/typeYes3.3adhesionAdhesion test (annex F.3)See product descriptionEach batch: 2 samples/typeYes3.4volatile content (if no information from supplier is available)Weight lossSee product descriptionEach batch: 2 samples/typeYes4
Desiccant:4.1packaging and labelVisualSee purchase specificationEach batch: 1No4.2activity :
test method shall be in agreement with desiccant supplier, eg. DT measurementSee annex Kinitial H2O content £ 3 %Each batch: 1YesNOTE 1
Per shift means minimal 1 per day and maximal 3 per day and per typeSIST EN 1279-6:2004
EN 1279-6:2002 (E)14Table A.2 - Inspection and test table for air-filled organic sealed insulating glass units with hollow spacer (continued)Section 1: Material Control (See also 5.2.6)Ref.Material, inspection or testRecommended method(decision to be made bymanufacturer)RequirementRecommended frequency(decision to be made bymanufacturer)Record5
Inserts:5.1packaging and labelVisualSee purchase specificationEach batch: 1No5.2dimensionsMeasurementSee purchase specificationEach batch: 2 samples/typeYes5.3volatile content (if no information from supplier is available)Weight lossSee product descriptionEach batch: 2 samples/typeYes6
Leaded light strip:6.1packaging and labelVisualSee purchase specificationEach batch: 1No6.2dimensionsMeasurementSee purchase specificationEach batch: 2 samplesYes6.3adhesionAdhesion test (annex J)See product descriptionEach batch: 2 samplesYes6.4volatile content (if no information from supplier is available)Weight lossSee product descriptionEach batch: 2 samplesYes7
Outer seal:7.1packaging and labelVisualSee purchase specificationEach batch: 1No7.2shelf lifeVisualSuppliers' specificationEach batch: 1No7.3.aadhesion on glass and on spacer (not needed for structural seals)Adhesion test (F.3)Refer to F.3.3Each batch: 2 samplesYes7.3.badhesion on glass (edge seals for structural purposes)Tensile test EN 1279-4prEN 13022Each batch: 2 samplesYes7.4hardness: may be combined with, and see further, Section 2: Production control, line 7.5 of this tableEach batch: 2 samples/typeYes7.5volatile content (if no information from supplier is available)Weight lossSee product descriptionEach batch: 2 samples/typeYes8
Inner seal:8.1packaging and labelVisualSee purchase specificationEach batch: 1No8.2penetration (if there is no information from supplier)ISO 2137See purchase specificationEach batch: 2 samples/typeNo8.3volatile content (if no information from supplier is available)Weight lossSee purchase specificationEach batch: 2 samples/typeYes9
Marking materials:9.1packaging and labelVisualSee purchase specificationEach batch: 1NoSIST EN 1279-6:2004
EN 1279-6:2002 (E)15Table A.2 - Inspection and test table for Air-filled organic sealed insulating glass units with hollow spacer (continued)Section 1: Material Control (See also 5.2.6)Ref.Material, inspection or testRecommended method(decision to be made bymanufacturer)RequirementRecommended frequency(decision to be made bymanufacturer)Record10
Cutting oil:10.1packaging and labelVisualSee purchase specificationEach batch: 1No11
Washing machine liquid:11.1packaging and labelVisualSee purchase specificationEach batch: 1NoSection 2: Production controlRef.Material, inspection or testRecommended method(decision to be made bymanufacturer)RequirementRecommended frequency(decision to be made bymanufacturer)Record1
Cutting of glass (if relevant):1.1type of glassVisualSee relevant specificationsContinuallyNo1.2cutting qualityVisualSee relevant specificationsContinuallyNo1.3dimensionsMeasurementSee relevant specifications1 plate/shift and lineYes1.4thicknessVisualSee relevant specificationsContinuallyNo1.5stripping of coatingvisualSee relevant specificationsContinuallyNo2
Washing efficiency:2.1residue cutting lubricantVisualNo visible contaminationContinuallyNo2.2dry and clean glass surfaceVisualNo visible contaminationContinuallyNoSIST EN 1279-6:2004
EN 1279-6:2002 (E)16Table A.2 - Inspection and test table for Air-filled organic sealed insulating glass units with hollow spacer (continued)Section 2: Production controlRef.Material, inspection or testRecommended method(decision to be made bymanufacturer)RequirementRecommended frequency(decision to be made bymanufacturer)Record3
Spacer bar:3.1dimensions in relation to glass dimensionsMeasurementSee product descriptionPer shift and width of spacer: 1 frameYes3.2desiccant filling (quantity)MeasurementSee product descriptionPer shift and per type: 1Yes3.3contaminationVisualSee product descriptionPer shift and per type: 1No3.4bending qualityVisualContinuallyNo3.5junction(s)VisualSee product descriptionContinuallyNo3.6placing frame on glassVisualContinuallyNo4
Spacer tape:4.1applicationVisualSee product descriptionContinuallyNo5
Desiccant (taken from a frame just before sealing into a unit):5.1activity :
test method shall be in agreement with desiccant supplier, eg. DT measurementSee annex Kinitial H2O content £ 3 %Per shift: 1Yes6
Inner seal (if relevant)6.1continuityVisualSee product descriptionContinuallyNo6.2thread at cornersVisualSee product descriptionContinuallyNo6.3extruded behaviourVisualSee product descriptionContinuallyNo6.4contamination's in the bonding areaVisualSee product descriptionContinuallyNo6.5amount of inner seal material per extruder headmeasurementSee product descriptioneach dayYesSIST EN 1279-6:2004
EN 1279-6:2002 (E)17Table A.2 - Inspection and test table for Air-filled organic sealed insulating glass units with hollow spacer (continued)Section 2: Production controlRef.Material, inspection or testRecommended method(decision to be made bymanufacturer)RequirementRecommended frequency(decision to be made bymanufacturer)Record7
Outer seal:7.1adhesion (not needed for structural seals)Annex F (If possible, butterflytest)F.3 or F.4.1 or F.4.2Per day and at least per batch: 1Yes7.2adhesion (edge seals for structural purposes)Tensile test EN 1279-4prEN 13022Each batch: 2 samplesYes7.3mixing ratioSee equipment- and sealantspecificationsSee sealant specificationSee quality manualYes7.4thoroughness of mixingMixing check (annex D)No marblingPer shift: 1Yes7.5air inclusions (during 7.3, thoroughness of mixing)No air inclusionsNo7.6hardnessHardness test (annex E)See product descriptionPer shift: 2 samplesYes7.7contaminationVisualSee purchase specificationEach drumNoSection 3: Product controlRef.Inspection or testRecommended method(decision to be made bymanufacturer)RequirementRecommended frequency(decision to be made bymanufacturer)Record1
Inner seal: (if relevant)1.1dimensionsMeasurementSee product descriptionRandom inspection plan (Table A.1)Yes1.2occurrences exceeding absolute limitsVisualSee product descriptionRandom inspection plan (Table A.1)Yes2
Outer seal:2.1dimensionsMeasurementSee product descriptionRandom inspection plan (Table A.1)Yes2.2occurrences exceeding absolute limitsVisualSee product descriptionRandom inspection plan (Table A.1)YesSIST EN 1279-6:2004
EN 1279-6:2002 (E)18Table A.2 - Inspection and test table for air-filled organic sealed insulating glass units with hollow spacer (concluded)Section 3: Product controlRef.Inspection or testRecommended method(decision to be made bymanufacturer)RequirementRecommended frequency(decision to be made bymanufacturer)Record3Glass components or type of used glassesVisualSee labelRandom inspection plan (Table A.1)Yes4Dimensions of unit (length and width)MeasurementSee relevant specificationsRandom inspection plan (Table A.1)Yes5Glass blemishesVisualSee internal quality standardRandom inspection plan (Table A.1)Yes6StorageVisualSee product descriptionOnce per shiftNo7MarkingVisualSee product descriptionRandom inspection plan (Table A.1)Yes8Flatness (immediately after sealing the unit)VisualNo remarkable deviationRandom inspection plan (Table A.1)Yes9Fogging (This test is relevant when no information exist on thevolatile contents of the releva
...
Questions, Comments and Discussion