SIST EN 12312-5:2005
(Main)Aircraft ground support equipment - Specific requirements - Part 5: Aircraft fuelling equipment
Aircraft ground support equipment - Specific requirements - Part 5: Aircraft fuelling equipment
This part of EN 12312 specifies the minimum essential safety requirements for the design and construction of "Aircraft refuellers, hydrant dispensers and fuelling equipment" used for the delivery of aviation fuels to aircraft. It applies to both rigid vehicles (with or without drawbar trailers) and to articulated tractor and trailer combinations, vehicles classed as hydrant dispensers, hydrant pit servicing vehicles and any other type of equipment which is used directly for servicing aircraft with aviation fuels.
Luftfahrt-Bodengeräte - Besondere Anforderungen - Teil 5: Betankungseinrichtungen für Luftfahrzeuge
Dieses Dokument legt die technischen Anforderungen zur Minimierung der in Abschnitt 4 aufgelisteten
Gefährdungen fest, die bei der Inbetriebnahme, Betrieb und Wartung von Betankungseinrichtungen für
Luftfahrzeuge auftreten können, wenn diese in Übereinstimmung mit den Anweisungen des Herstellers oder
seines Beauftragten ausgeführt werden. Sie berücksichtigt auch einige Funktions- und Gestaltungs-
anforderungen, die von offiziellen Stellen, Luftfahrzeug- und Bodengeräteherstellern sowie von Luftverkehrs-
gesellschaften, Flughafenbetreibern und Betankungsgesellschaften als wesentlich erachtet wurden.
Dieses Dokument gilt für alle Betankungsgeräte-Typen:
- Flugfeldtankfahrzeuge;
- Dispenser;
- Rücktankfahrzeuge;
- Hydrantenwartungsfahrzeuge;
- stationäre Betankungseinheiten,
die dazu bestimmt sind, Luftfahrzeuge mit Flugkraftstoff zu versorgen, und die für den Betrieb auf Flugfeldern,
Hubschrauberlandeplätzen und anderen Bereichen für die Luftfahrzeugbetankung wie Wartungsplätzen
vorgesehen sind.
ANMERKUNG 1 Im Allgemeinen ist das Europäische Übereinkommen über die internationale Beförderung gefährlicher
Güter auf der Straße (ADR) nicht auf die Luftfahrzeug-Betankungseinrichtungen anwendbar, da diese nicht für die
Benutzung auf öffentlichen Straßen konzipiert sind. Bei der Ausarbeitung der vorliegenden Norm wurden jedoch
verschiedene Anforderungen aus dem ADR berücksichtigt.
Der Betrieb von AFE auf öffentlichen Straßen ist nicht vorgesehen, mit folgenden Ausnahmen:
- Transport von Kraftstoff zwischen Tanklagern und Betankungsbereichen;
- Wartungszwecke mit leeren Ladungstanks.
ANMERKUNG 2 Dies kann das Erfordernis einschließen, nationale Verkehrsbeschränkungen zu beachten (siehe
Abschnitt 0 von EN 1915-1:2001 ? Vereinbarungen).
Matériel au sol pour aéronefs - Exigences particulieres - Partie 5: Matériels d'avitaillement en carburant
Le présent document définit les exigences techniques pour minimiser les dangers listés a l'Article 4 qui
peuvent intervenir durant la mise en service, l?exploitation et la maintenance des AFE, lorsqu?elles sont
effectuées en accord avec les spécifications fournies par le fabricant ou son représentant autorisé. Elle tient
compte de plus d?exigences reconnues essentielles par les autorités, les fabricants d?aéronefs et de matériels
de service au sol (GSE) ainsi que les compagnies aériennes, les aéroports et les sociétés pétrolieres.
Le présent document est applicable a tous types de matériels d?avitaillement d?aéronefs :
.avitailleurs d?aéronefs,
.oléoserveurs ,
.véhicules de reprise,
.véhicules de service des prises d'oléoréseau,
.unités de distribution fixes,
destinés a l?approvisionnent des aéronefs en carburants aviation et a l?utilisation sur les aéroports, héliports et
autres zones d?avitaillement telles que les bases de maintenance.
NOTE 1 D?une maniere générale, l?Accord Européen sur le Transport Routier International des Produits Dangereux
(ADR) n?est pas applicable aux AFE car ils ne sont pas sensés etre utilisés sur la voie publique. Toutefois, certaines
exigences ont été prise en compte en développant la présente norme.
L?utilisation des AFE sur la voie publique n?est pas prévu sauf exceptions suivantes :
.transport entre les parcs de réservoirs de stockage et les aérodromes ;
.opérations d'entretien effectuées citernes vides.
NOTE 2 Ceci peut créer un besoin de dérogation locale au trafic (voir Article 0 de l?EN 1915-1:2001 ? négociation).
Podporna oprema na tleh za letalski promet - Posebne zahteve - 5. del: Oprema za oskrbo letal z gorivom
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 12312-5:2005
01-maj-2005
Podporna oprema na tleh za letalski promet - Posebne zahteve - 5. del: Oprema za
oskrbo letal z gorivom
Aircraft ground support equipment - Specific requirements - Part 5: Aircraft fuelling
equipment
Luftfahrt-Bodengeräte - Besondere Anforderungen - Teil 5: Betankungseinrichtungen für
Luftfahrzeuge
Matériel au sol pour aéronefs - Exigences particulieres - Partie 5: Matériels
d'avitaillement en carburant
Ta slovenski standard je istoveten z: EN 12312-5:2005
ICS:
49.100 Oprema za servis in Ground service and
vzdrževanje na tleh maintenance equipment
SIST EN 12312-5:2005 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
EUROPEAN STANDARD
EN 12312-5
NORME EUROPÉENNE
EUROPÄISCHE NORM
February 2005
ICS 49.100
English version
Aircraft ground support equipment - Specific requirements - Part
5: Aircraft fuelling equipment
Matériel au sol pour aéronefs - Exigences particulières - Luftfahrt-Bodengeräte - Besondere Anforderungen - Teil 5:
Partie 5: Matériels d'avitaillement en carburant Betankungseinrichtungen für Luftfahrzeuge
This European Standard was approved by CEN on 3 January 2005.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Central Secretariat or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,
Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,
Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36 B-1050 Brussels
© 2005 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 12312-5:2005: E
worldwide for CEN national Members.
---------------------- Page: 2 ----------------------
EN 12312-5:2005 (E)
Contents
page
Foreword.3
Introduction .4
1 Scope .5
2 Normative references .6
3 Terms and definitions .7
4 List of hazards.12
5 Safety requirements and/or measures .12
5.1 General requirements.12
5.2 Chassis, Engine .12
5.3 Additional requirements for trailers.14
5.4 Vehicle electrical system .14
5.5 Driver’s cabin .17
5.6 Fuelling platforms.18
5.7 Specific fuelling equipment.18
6 Information for use .26
6.1 General marking.26
6.2 Additional marking .26
6.3 Warnings.26
6.4 Instructions .27
7 Verification of requirements.27
Annex A (informative) Aircraft fuelling equipment: brief description.29
A.1 Aircraft refueller.29
A.2 Hydrant dispenser .29
A.3 Pressure control .29
A.4 Metering.30
A.5 Platforms .30
A.6 Hoses .30
A.7 Typical fuel circuit diagrams .30
Annex B (normative) Aircraft fuelling equipment: basic requirements .33
B.1 Pressure definitions .33
B.2 Filtration.33
B.3 Pipes, fittings and joints .33
B.4 Calculation of emergency venting requirements in case of fire engulfment .33
Annex C (normative) List of hazards in addition to those of EN 1915-1 .35
Annex ZA (informative) Relationship between this European Standard and the Essential
Requirements of EU Directive 98/37/EC, amended by Directive 98/79/EC.37
Bibliography .38
2
---------------------- Page: 3 ----------------------
EN 12312-5:2005 (E)
Foreword
This document (EN 12312-5:2005) has been prepared by Technical Committee CEN/TC 274 "Aircraft ground support
equipment" the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an identical text or
by endorsement, at the latest by August 2005, and conflicting national standards shall be withdrawn at the latest by
August 2005.
This document has been prepared under a mandate given to CEN by the European Commission and the European
Free Trade Association and supports essential requirements of EU Directive(s).
For relationship with EU Directives, see informative Annex ZA, which is an integral part of this document.
The Parts of EN 12312 — Aircraft ground support equipment — Specific requirements — are:
Part 1: Passenger stairs
Part 2: Catering vehicles
Part 3: Conveyor belt vehicles
Part 4: Passenger boarding bridges
Part 5: Aircraft fuelling equipment
Part 6: Deicers and deicing/antiicing equipment
Part 7: Aircraft movement equipment
Part 8: Maintenance stairs and platforms
Part 9: Container/Pallet loaders
Part 10: Container/Pallet transfer transporters
Part 11: Container/Pallet dollies and loose load trailers
Part 12: Potable water service equipment
Part 13: Lavatory service equipment
Part 14: Disabled/Incapacitated passenger boarding equipment
Part 15: Baggage and equipment tractors
Part 16: Air start equipment
Part 17: Air conditioning equipment
Part 18: Nitrogen or Oxygen units
Part 19: Aircraft jacks, axle jacks and hydraulic tail stanchions
Part 20: Ground power equipment
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following coun-
tries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Esto-
nia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
3
---------------------- Page: 4 ----------------------
EN 12312-5:2005 (E)
Introduction
This document specifies health and safety requirements, as well as some functional and performance requirements
for aircraft fuelling equipment (AFE) intended for use on all aircraft types commonly in service in civil air transport.
The minimum essential criteria are considered to be of primary importance in providing safe, serviceable, economical
and practical AFE. Deviations from the recommended criteria should occur only after careful consideration, extensive
testing, risk assessment and thorough service evaluation have shown alternative methods or conditions to be satisfac-
tory.
This document is a Type C standard as stated in EN ISO12100-1 and EN ISO 12100-2.
The machinery concerned and the extent to which hazards, hazardous situations and events are covered are indi-
cated in the scope of this document.
When provisions of this type C standard are different from those which are stated in type A or B standards, the pro-
visions of this type C standard take precedence over the provisions of the other standards, for machines that have
been designed and built according to the provisions of this type C standard.
4
---------------------- Page: 5 ----------------------
EN 12312-5:2005 (E)
1 Scope
This document specifies the technical requirements to minimise the hazards listed in Clause 4 which can arise dur-
ing the commissioning, operation and maintenance of AFE when carried out in accordance with the specifications
given by the manufacturer or his authorised representative. It also takes into account some performance require-
ments recognised as essential by authorities, aircraft and ground support equipment (GSE) manufacturers as well
as airlines, airports and fuelling companies.
This document applies to all types of aircraft fuelling equipment:
aircraft refuellers;
hydrant dispensers;
defuellers;
hydrant pit servicing vehicles;
stationary dispensing units,
intended to service aircraft with aviation fuels and to be operated on airfields, heliports and other aircraft refuelling
related areas such as maintenance bases.
NOTE 1 In general, the European Agreement concerning the International Carriage of Dangerous Goods by Road (ADR) is
not applicable to AFE as they are not deemed to be used on public roads. However, certain requirements have been considered
when developing this standard.
The use of AFE on public roads is not intended with the following exceptions:
transportation of fuel from tank farms to refuelling areas;
maintenance purposes with empty cargo tanks.
NOTE 2 This may include the need of local traffic derogation (see Clause 0 of EN 1915-1:2001 — negotiation).
The intended functions of AFE are:
loading fuel from the tank farm and/or a hydrant system to the AFE;
storage and transportation of fuel;
fuelling from the AFE to the aircraft;
filtration of the fuel;
metering the fuel for a transfer of custody;
defuelling the aircraft to the AFE;
flushing fuel from hydrant systems;
unloading AFE to the tank farm after defuelling of an aircraft;
transferring fuel from one AFE to another.
This document does not apply to:
AFE whose only power source for aircraft refuelling is directly applied manual effort;
hydrant systems, tank farms, pipework and underground tanks;
specific hazards due to the operation of the AFE in a potentially explosive atmosphere;
5
---------------------- Page: 6 ----------------------
EN 12312-5:2005 (E)
built-in fire extinguisher systems.
This document does not establish requirements for noise and vibration.
Noise and vibration are dealt with respectively in EN 1915-4 and EN 1915-3.
This document does not deal with hazards in respect to a standard automotive chassis and from other vehicles on
the apron.
This document is not applicable to AFE which are manufactured before the date of publication of this document by
CEN.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references,
only the edition cited applies. For undated references, the latest edition of the referenced document (including any
amendments) applies.
EN 418:1992, Safety of machinery — Emergency stop equipment, functional aspects — Principles for design.
EN 764, Pressure equipment — Terminology and symbols — Pressure, temperature, volume.
EN 954-1, Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design.
EN 1050:1996, Safety of machinery — Principles for risk assessment.
EN 1361, Rubber hoses and hose assemblies for aviation fuel handling - Specification.
EN 1915-1:2001, Aircraft ground support equipment - General requirements — Part 1: Basic safety requirements.
EN 1915-2, Aircraft ground support equipment - General requirements — Part 2: Stability and strength
requirements, calculations and test methods.
EN 50020, Electrical apparatus for potentially explosive atmospheres — Intrinsic safety "i".
EN 60079-0:2004, Electrical apparatus for explosive gas atmospheres – Part 0: General requirements (IEC 60079-
0:2004).
EN 60079-1:2004, Electrical apparatus for potentially explosive atmospheres – Part 1: Flameproof enclosure “d”
(IEC 60079-1:2003).
EN 60079-2:2004, Electrical apparatus for explosive gas atmospheres – Part 2: Pressurized enclosure “p” (IEC
160079-2:2001).
EN 60079-7, 2003, Electrical apparatus for explosive gas atmospheres – Part 7: Increased safety “e” (IEC 60079-
7:2001).
EN 60079-14:2003, Electrical apparatus for explosive gas atmospheres – Part 14: Electrical installations in hazard-
ous areas (other than mines) (IEC 60079-14:2002).
EN 60079-15:2003, Electrical apparatus for explosive gas atmospheres – Part 15: Type of protection “n” (IEC
60079-15:2001, modified).
EN 60079-18:2004, Electrical apparatus for explosive gas atmospheres – Part 18: Construction, test, and marking
of type of protection encapsulation “m” electrical apparatus (IEC 60079-18:2004).
EN 60529, Degrees of protection provided by enclosures (IP code) (IEC 60529:1989).
EN ISO 12100-1:2003, Safety of machinery - Basic concepts, general principles for design - Part 1: Basic terminol-
ogy, methodology (ISO 12100-1:2003).
EN ISO 12100-2:2003, Safety of machinery - Basic concepts, general principles for design - Part 2: Technical prin-
ciples (ISO 12100-2:2003).
6
---------------------- Page: 7 ----------------------
EN 12312-5:2005 (E)
ISO 45, Aircraft - Pressure refuelling connections.
ISO 46:1973, Aircraft - Fuel nozzle grounding plugs and sockets.
1)
ISO 102:1990, Aircraft - Gravity filling orifices.
ISO 1102, Commercial road vehicles —50 mm drawbar eye — Interchangeability.
ISO 1728, Road vehicles — Pneumatic braking connections between motor vehicles and towed vehicles — Inter-
1)
changeability.
ISO 2883, Rubber, vulcanized — Antistatic and conductive products for industrial use — Electrical resistance limits.
ISO 3584, Road vehicles — Drawbar couplings — Interchangeability.
ISO 3795, Road vehicles, and tractors and machinery for agriculture and forestry — Determination of burning be-
haviour of interior materials.
ISO 4009, Commercial vehicles — Location of electrical and pneumatic connections between towing vehicles and
trailers.
ISO 8755, Commercial road vehicles — 40 mm drawbar eye — Interchangeability.
IEC 60079-5:1997, Electrical apparatus for explosive gas atmospheres — Part 5: Powder filling "q".
IEC 60079-6:1995, Electrical apparatus for explosive gas atmospheres — Part 6: Oil-immersion "o".
IEC 60079-11:1999, Electrical apparatus for explosive gas atmospheres — Part 11: Intrinsic safety "i".
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN ISO 12100-1:2003, EN ISO 12100-2:2003
and EN 1915-1:2001 and the following apply.
3.1
aircraft fuelling equipment (AFE)
equipment used to handle aviation fuels on an airfield, including
— aircraft refuellers,
— hydrant dispensers,
— defuellers,
— hydrant pit servicing vehicles,
— stationary dispensing units
3.2
aircraft fuel control panel
aircraft mounted panel, used to control fuel distribution and quantities in aircraft tanks
3.3
aircraft refueller
self-propelled or towable vehicle designed to carry aviation fuel and capable of refuelling aircraft by means of an
on-board pump. Most vehicles of this type are also capable of defuelling aircraft
3.4
aircraft refuelling adapter
aircraft mounted adapter to which the pressure refuelling coupling is connected
NOTE A similar adapter may be used to connect loading hoses to an aircraft refueller.
1) Revision in preparation at the time of publication of this document.
7
---------------------- Page: 8 ----------------------
EN 12312-5:2005 (E)
3.5
aircraft refuelling pressure
fuel pressure allowed by the aircraft manufacturer or airline operator at the aircraft manifold during fuel flow
3.6
aviation fuels
hydrocarbon type liquids used as fuel in an aircraft engine including
— Jet fuel
Kerosene type distillate fuel used in turbine engines
— Aviation gasoline — Avgas
Gasoline for use in piston type aircraft engines
3.7
baffle
non liquid tight, transverse partition in a cargo tank
NOTE If the baffle is fitted longitudinally it is called "a longitudinal baffle".
3.8
baffled area
part of the cargo tank between two baffles or between baffle and tank end
3.9
battery master switch
switch fitted close to the vehicle battery for isolating circuits of the AFE’s electrical system
3.10
bonding cable
electrically conducting cable/wire to equalise electrical potential, e.g. between AFE and aircraft, aircraft refueller
and loading facility
3.11
bonding point
designated attachment point for the bonding cable to ensure good electrical continuity
3.12
bottom loading
loading an aircraft refueller or cargo tank into the bottom of the tank through a closed system
3.13
bottom loading adapter
self-sealing device to which the loading hose or arm is connected
3.14
brake interlock
system fitted to ensure that the vehicle cannot be moved, if hoses and/or other equipment have not been
disconnected from aircraft or loading point and properly stowed, lowered or secured
3.15
bulkhead
liquid tight, transverse closure between compartments of a cargo tank
3.16
bulk meter
means of measuring the quantity of fuel passed through it
3.17
cargo tank
tank for the carrying of aviation fuels, having a liquid capacity of more than 1 000 litres, mounted permanently or
otherwise secured on an AFE
8
---------------------- Page: 9 ----------------------
EN 12312-5:2005 (E)
3.18
chassis
— self-propelled chassis: part of the vehicle which comprises the driver’s or operator’s cabin, the engine and
transmission including the fuel, intake and exhaust systems, the wheels, axles, suspension system, braking
system and other parts of the running gear, the fifth wheel assembly (for towing a semi-trailer) or the drawbar
coupling (for towing drawbar trailers), the lights and electrical system that are usually fitted by the manufac-
turer of the chassis and the frame on which it is built
— trailer chassis: part of the trailer which comprises the running gear (wheels, axles, suspension system and
braking system), the drawbar or A frame, that part of the assembly fitted to the trailer to connect to the tractor
fifth wheel (the rubbing plate), the lights and electrical system and the frame on which the tank and/or equip-
ment is fitted
3.19
closed circuit overwing/trigger nozzle
nozzle connected mechanically to the fuel filling orifice which is vented to the atmosphere
3.20
compartment
liquid tight division in a cargo tank
3.21
hold to run control ("deadman control")
device that requires permanent or pulsing operator input throughout an operation in order for the operation to
continue and which stops the operation if not properly activated
3.22
hold to run valve ("deadman valve")
on-off valve to start and stop the flow of fuel, controlled by the hold to run control
3.23
defueller
vehicle designed to defuel but not to refuel aircraft
3.24
defuelling
function of removing fuel from an aircraft into a vehicle, usually through the aircraft refuelling adapters. This is
subdivided into:
— pressure defuelling: when aircraft pumps are used to pump the fuel from the tanks of the aircraft to the AFE;
— suction defuelling: when AFE’s pump is used to draw the fuel from the aircraft.
A combination of both may be used
3.25
filtration equipment
device installed on the AFE through which the aviation fuel passes for removal of particulate matter and water
3.26
fuel sense pressure
pressure measured in a refuelling system downstream of the pressure control device used as a reference for the
pressure control device (see also Pressure Control System)
3.27
hose end pressure control valve (HEPCV)
pressure regulator mounted on the refuelling coupling to limit pressure at its outlet and to control surge pressure
limits at the aircraft fuelling adapter
3.28
hydrant dispenser
self-propelled or towable vehicle used to refuel aircraft requiring an external fuel supply. The pressure source is the
hydrant system
9
---------------------- Page: 10 ----------------------
EN 12312-5:2005 (E)
NOTE Hydrant dispensers may be fitted with a boost pump where hydrant pressure is insufficient to provide adequate flow
rates into the aircraft.
3.29
hydrant pit box
box set in the operational area which contains the hydrant pit valve or the low point or vent valve
3.30
hydrant pit coupler
device fitted to the intake hose to connect the hose to the hydrant pit valve
NOTE The coupler may be fitted with additional devices such as deadman control, pressure control and an excess flow
limiter.
3.31
hydrant pit servicing vehicle
AFE designed to flush and test hydrant pit valves in situ as well as to flush and vent low and high points on the
hydrant system
3.32
hydrant pit valve
valve set in a hydrant pit box, equipped with an emergency shut-off device, to which the hydrant pit coupler can be
attached
NOTE The hydrant pit valve may be fitted with additional devices such as deadman control, pressure control valve or
excess flow limiter.
3.33
hydrant system
system of tanks, stationary pumps, valves, filters and pipework to supply fuel to the operational area where aircraft
are refuelled
3.34
in-line pressure control valve
valve installed in the AFE pipework or at the hydrant pit coupler to control fuel pressure
NOTE It may also incorporate the deadman function.
3.35
intake hose
hose for fuel flow from the hydrant pit valve to the AFE
3.36
interlock override switch
device to render the brake interlock inoperative in emergency situations
3.37
brake interlock
device which prevents a vehicle being moved when components are not in their secured positions
3.38
internal stop valve
valve designed for loading or discharging of fuel fitted in the bottom of a cargo tank
3.39
operational area
part of an airfield used for servicing aircraft
3.40
overwing/trigger nozzle
nozzle used for non-pressure fuelling and hand held in an open fuel filling orifice giving access to the aircraft fuel
tank
10
---------------------- Page: 11 ----------------------
EN 12312-5:2005 (E)
3.41
power take-off
device fitted to the vehicle to provide power to auxiliary services such as a hydraulic pump or fuel pump
3.42
pressure control system
system fitted to AFE or hydrant pit valves to limit the pressure of fuel delivered to aircraft
3.43
pressure refuelling coupling
quick disconnect device, used in pressure refuelling, fitted to the hose end, connecting hose and aircraft fuelling
adapter
3.44
refuelling
— underwing or pressure refuelling: refuelling under positive pressure through a coupling directly connected to
the aircraft fuelling adapter;
— overwing or non-pressure refuelling: refuelling at atmospheric pressure through an overwing/trigger nozzle and
entered into a fuel filling orifice
3.45
refuelling platform
fixed or moveable platform to enable the operator to gain access to the aircraft fuel control panel and aircraft
refuelling adapters
NOTE This may be an elevating platform, an extending structure or both, and may be part of or remote from an AFE.
3.46
rigid vehicle
self-propelled road chassis to which an aviation fuel tank is permanently attached
3.47
self-loading/dual purpose refueller
vehicle equipped to be self-loaded from the hydrant system or fitted out as a dual purpose vehicle that can also be
used as a hydrant dispenser, i.e. hydrant sourced fuel is delivered directly to the aircraft and not via the cargo tank.
In both cases, the refuellers are fitted with an intake hose and coupler to connect to the hydrant pit valve
3.48
specific fuelling equipment
part of the AFE comprising the fuel handling components, including, but not limited to
— cargo tank,
— deadman systems,
— filtration,
— hoses,
— metering equipment,
— pipework,
— pressure control,
— pumps,
— sampling devices,
— valves
3.49
static dissipator additive (SDA)
additive added to the fuel to increase its electrical conductivity
NOTE Also known as conductivity improver or anti static additive.
3.50
stationary dispensing unit
underground rising platform and/or fixed unit designed to refuel aircraft
11
---------------------- Page: 12 ----------------------
EN 12312-5:2005 (E)
3.51
surge pressure
pressure generated by the sudden deceleration of a liquid within a hydraulic or fuel system
3.52
vacuum breaker
valve mounted in a system to allow automatic or manual relief of negative pressures
4 List of hazards
The list of risks and hazards (see Annex C) is based on EN 1050 and contains the hazards and hazardous situa-
tions, as far as they are dealt with in this document, identified by risk assessment as significant for aircraft fuelling
equipment and which require action to eliminate or reduce risks.
5 Safety requirements and/or measures
5.1 General requirements
5.1.1 Aircraft fuelling equipment shall conform to the requirements of EN 1915-1, unless otherwise specified in
this standard. It shall also conform to the specific requirements of this document.
5.1.2 Vehicles shall not exceed an overall height of 3,6 m and an overall width of 3,6 m in driving configuration.
Devices which protrude outside of the contour of the vehicle, e.g. intake hose holders, support brackets etc., shall
be of removable construction.
5.1.3 Stability and strength calculations shall be carried out in accordance with EN 1915-2.
5.1.4 AFE shall be designed for the intended fuel grade(s). They shall carry only one grade of aviation fuel.
5.1.5 For aircraft refuellers, the height of the centre of gravity of the rated load shall not be greater than 95 % of
the distance between the outer wall of the supporting tyres measured at the outside of their contact with the
ground.
5.1.6 Where built-in fire extinguisher systems are not provided, provision shall be made on all moveable AFE for
the fitting of at least two dry chemical type fire extinguishers of a minimum capacity of 6 kg, accessible from t
...
Questions, Comments and Discussion