Paper and board -- Determination of CIE-whiteness, C/2 degree (indoor illumination conditions)

Papier et carton -- Détermination du degré de blanc CIE C/2 degrés (éclairage intérieur)

Papir, karton in lepenka – Določanje beline po CIE, C/2° (pogoji osvetlitve v prostoru)

General Information

Status
Withdrawn
Publication Date
29-Feb-2004
Withdrawal Date
06-Apr-2011
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
07-Apr-2011
Due Date
30-Apr-2011
Completion Date
07-Apr-2011

Relations

Buy Standard

Standard
ISO 11476:2000 - Paper and board -- Determination of CIE-whiteness, C/2 degree (indoor illumination conditions)
English language
13 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 11476:2004
English language
18 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
ISO 11476:2000 - Papier et carton -- Détermination du degré de blanc CIE C/2 degrés (éclairage intérieur)
French language
13 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 11476
First edition
2000-11-15
Paper and board — Determination of CIE
whiteness, C/2° (indoor illumination
conditions)
Papier et carton — Détermination du degré de blanc CIE, C/2° (éclairage
intérieur)
Reference number
ISO 11476:2000(E)
©
ISO 2000

---------------------- Page: 1 ----------------------
ISO 11476:2000(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall not
be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this
file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat accepts no liability in this
area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters
were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event
that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2000
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic
or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO's member body
in the country of the requester.
ISO copyright office
Case postale 56 � CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.ch
Web www.iso.ch
Printed in Switzerland
ii © ISO 2000 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 11476:2000(E)
Contents Page
Foreword.iv
1 Scope .1
2 Normative references .1
3 Terms and definitions .2
4 Principle.3
5 Apparatus and equipment .3
6 Calibration .4
7 Sampling.5
8 Preparation of test pieces.5
9 Procedure .5
10 Calculation and expression of results.5
11 Precision.6
12 Test report .7
Annex A (normative) Spectral characteristics of reflectometers for determining tristimulus values .8
Annex B (normative) UV-calibration service .11
Bibliography.13
© ISO 2000 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO 11476:2000(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO
member bodies). The work of preparing International Standards is normally carried out through ISO technical
committees. Each member body interested in a subject for which a technical committee has been established has
the right to be represented on that committee. International organizations, governmental and non-governmental, in
liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical
Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 3.
Draft International Standards adopted by the technical committees are circulated to the member bodies for voting.
Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this International Standard may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights.
International Standard ISO 11476 was prepared by Technical Committee ISO/TC 6, Paper, board and pulps.It is
based on the CIE-whiteness formula, published in CIE Publication 15.2-1986, Colorimetry.
Annexes A and B form a normative part of this International Standard.
iv © ISO 2000 – All rights reserved

---------------------- Page: 4 ----------------------
INTERNATIONAL STANDARD ISO 11476:2000(E)
Paper and board — Determination of CIE whiteness, C/2° (indoor
illumination conditions)
1 Scope
This International Standard specifies the procedure to be used for determining the whiteness of papers and boards,
in order to obtain values which correspond to the visual appearance of white papers and boards, with or without
fluorescent whitening agents, when they are viewed indoors. It is based on radiance factor data obtained over the
full visible spectral range (VIS) in contrast to the measurement of ISO brightness, which is limited to the blue region
of VIS.
[1] [2]
In addition, it specifies a method for adjustment of the UV-content to correspond to the CIE illuminant C ,since
the results obtained when fluorescent whitening agents are present are dependent upon the UV-content of the
radiation falling upon the sample. The CIE illumination C is taken to be representative of indoor illumination
[3] [4]
conditions because it contains a suitable proportion of UV-radiation . This method is not applicable to coloured
papers containing fluorescent dyes. It is specific for the situation where the fluorescence occurs in the blue region
of the visible spectral range.
This International Standard should be read in conjunction with ISO 2469.
NOTE 1 It is recognized that the CIE-whiteness equation was developed in the context of the CIE standard illuminant
[10]
D65 , but the similarity between the relative spectral power curves for the C and D65 illuminants within the visible region and
the closeness of their correlated colour temperatures (6 770 K and 6 500 K respectively) is taken as a justification for the use of
the analogous whiteness equation with the CIE illuminant C.
[13]
NOTE 2 A related International Standard, ISO 11475 specifies the procedure for obtaining values corresponding to the
appearance of papers viewed under the CIE illuminant D65.
2 Normative references
The following normative documents contain provisions which, through reference in this text, constitute provisions of
this International Standard. For dated references, subsequent amendments to, or revisions of, any of these
publications do not apply. However, parties to agreements based on this International Standard are encouraged to
investigate the possibility of applying the most recent editions of the normative documents indicated below. For
undated references, the latest edition of the normative document referred to applies. Members of ISO and IEC
maintain registers of currently valid International Standards.
ISO 186:1994, Paper and board — Sampling to determine average quality.
ISO 2469, Paper, board and pulps — Measurement of diffuse reflectance factor.
ISO 2470, Paper, board and pulps — Measurement of diffuse blue reflectance factor (ISO brightness).
© ISO 2000 – All rights reserved 1

---------------------- Page: 5 ----------------------
ISO 11476:2000(E)
3 Terms and definitions
For the purposes of this International Standard, the following terms and definitions apply.
3.1
reflectance factor
R
ratio of the radiation reflected by a body to that reflected by the perfect reflecting diffuser under the same conditions
NOTE The ratio is usually expressed as a percentage.
3.2
intrinsic reflectance factor
reflectivity
R

reflectance factor of a layer or pad of the material thick enough to be opaque, i.e. such that increasing the
thickness of the pad by doubling the number of sheets results in no change in the measured reflectance factor
3.3
radiance factor

ratio of the radiance of a body to that of the perfect reflecting diffuser under the same conditions of illumination and
viewing
NOTE For fluorescent (luminescent) materials, the total radiance factor, �, is the sum of two portions, the reflected
radiance factor,� , and the luminescent radiance factor,� ,so that
S L
�����
SL
For non-fluorescent materials, the reflected radiance factor,� is simply the reflectance factor, R.
S
3.4
intrinsic radiance factor


radiance factor of a layer or pad of the material thick enough to be opaque, i.e. such that increasing the thickness
of the pad by doubling the number of sheets results in no change in the measured radiance factor
NOTE For fluorescent (luminescent) materials, the intrinsic total radiance factor � , is the sum of two portions, the intrinsic

reflected radiance factor,� , and the intrinsic luminescent radiance factor,� ,sothat
�,S �,L
�����
��,S �,L
For non-fluorescent materials, the intrinsic reflected radiance factor,� , is simply the intrinsic reflectance factor R .
�,S �
3.5
CIE whiteness
W
measure of whiteness derived from the CIE tristimulus values determined under the conditions specified in this
International Standard, and expressed as whiteness units
3.6
green/red tint
T
w
measure of the deviation from whiteness of the test material towards the green or red region, and expressed as tint
units
NOTE A positive value of T indicates a greenish tint and a negative value indicates a reddish tint.
w
2 © ISO 2000 – All rights reserved

---------------------- Page: 6 ----------------------
ISO 11476:2000(E)
3.7
fluorescence component
W
F
measure of the extent to which the whiteness of the material is affected by excitation of the added fluorescent
whitening agent (FWA) under the conditions specified in this International Standard
4Principle
The diffuse radiance factor of the material is determined under standardized conditions after adjustment of the
instrument so that the relative UV-content of the illumination corresponds to that of the CIE illuminant C, and the
CIE whiteness and tint are calculated. The fluorescence component of the whiteness is calculated from the
difference between this diffuse-radiance-factor value and the value obtained when the fluorescence emission from
the material is eliminated, for instance by the introduction into the light beams of a sharp cut-off UV-absorbing filter.
5 Apparatus and equipment
5.1 Reflectometer or spectrophotometer, having the geometric, spectral and photometric characteristics
described in ISO 2469, calibrated in accordance with the provisions of ISO 2469, and equipped with a radiation
source having an adequate UV-content and a means of adjusting the relative UV-content so that the measured
ISO-brightness value agrees with the ISO-brightness value assigned to a fluorescent reference standard (5.2.2)
[2][5][6]
and corresponding to the CIE illuminant C . If a filter (the UV-adjustment filter) is used to make this
adjustment, it shall have a cut-off value of 395 nm so that it absorbs UV-radiation but does not at the same time
alter the visible spectrum within the sphere.
NOTE 1 In the 1994 edition of ISO 2469, the reflectometer characteristics are described in annex A and the calibration
service is described in annex B. When ISO 2469 is revised, the numbering may change; users of editions subsequent to 1994
should therefore determine which elements of text specify these characteristics and this service.
NOTE 2 In order to achieve concordance between the conditions for measuring both ISO brightness and CIE whiteness
(C/2°), an adjustment based on a reference standard having an assigned ISO-brightness value is preferred.
For the measurement of reflectance factors with the fluorescence effect eliminated, the instrument shall be
equipped with a sharp-cut-off, UV-absorbing filter (the UV-cut-off filter) having a transmittance not exceeding 5,0 %
at and below a wavelength of 410 nm and not exceeding 50 % at a wavelength of 420 nm. The cut-off filter shall
have characteristics such that a reliable reflectance-factor value is obtained at 420 nm. The reflectance-factor value
obtained at 420 nm shall then be considered for computational purposes to be the value, which applies at all lower
wavelengths, at which it is not possible to make any measurement.
For the measurement of fluorescent papers, photometric linearity up to a scale reading of at least 200 % is
necessary in the wavelength region corresponding to the fluorescent emission.
5.1.1 In the case of a filter reflectometer, pairs of filters giving the photoelectric detectors of the reflectometer
[7] [6]
responses equivalent to the CIE tristimulus values X, Y, Z of the test piece , evaluated for the CIE illuminant C
[8]
and CIE 1931 (2°) observer .
5.1.2 In the case of an abridged spectrophotometer, a means of calculating the weighted means according to the
requirements of the CIE illuminant C and CIE 1931 (2°) observer using the weighting functions given in annex A.
5.2 Reference standards for calibration of the instrument and working standards
5.2.1 Non-fluorescent reference standard for calibration, fulfilling the requirements for ISO reference standards of
level 3 as prescribed in ISO 2469.
5.2.2 Fluorescent reference standard for use in adjusting the UV-content of the radiation incident upon the
sample, having an assigned ISO-brightness value as specified in annex B and fulfilling the requirements for ISO
reference standards of level 3.
Use new reference standards sufficiently frequently to ensure satisfactory calibration and UV-adjustment.
© ISO 2000 – All rights reserved 3

---------------------- Page: 7 ----------------------
ISO 11476:2000(E)
5.3 Working standards
5.3.1 Two plates of flat opal glass or ceramic material, cleaned as described in ISO 2469.
5.3.2 A stable plastic or other tablet incorporating a fluorescent whitening agent.
5.4 Black cavity, having a reflectance factor which does not differ from its nominal value by more than 0,2 %, at
all wavelengths. The black cavity should be stored upside down in a dust-free environment or with a protective
cover.
NOTE The condition of the black cavity should be checked by reference to the instrument maker.
6 Calibration
6.1 Using the values assigned to the non-fluorescent reference standard (5.2.1), calibrate the instrument with the
UV-cut-off filters removed from the radiation beams. The setting of the UV-adjustment filter is not important at this
stage.
6.2 Using the appropriate measurement procedure, measure the reflectance of the fluorescent reference
standard (5.2.2), determine the ISO-brightness value as described in ISO 2470 and compare the value obtained
with that assigned to the fluorescent reference standard.
A measured ISO-brightness value higher than the assigned value indicates that the relative UV-content of the
illumination is too high and a lower value indicates that the relative UV-content is too low.
6.3 Using the UV-adjustment filter or other adjustment device, adjust the UV-content of the illumination until
measurement gives the correct ISO-brightness value.
6.4 Repeat the calibration as described in 6.1 using the non-fluorescent standard (5.2.1) with the UV-adjustment
in the position which gave the correct ISO-brightness value for the fluorescent reference standard. Repeat the
measurement of the brightness of the fluorescent standard (5.2.2) as described in 6.2. If the ISO-brightness value
obtained does not agree with the assigned value, adjust the position of the UV-adjustment filter until measurement
gives the correct ISO-brightness value as described in 6.3.
6.5 Repeat 6.4 until the correct value for the ISO brightness of the fluorescent standard is obtained wi
...

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.SURVWRUXPapier et carton -- Détermination du degré de blanc CIE C/2 degrés (éclairage intérieur)Paper and board -- Determination of CIE-whiteness, C/2 degree (indoor illumination conditions)85.060Papir, karton in lepenkaPaper and boardICS:Ta slovenski standard je istoveten z:ISO 11476:2000SIST ISO 11476:2004en01-marec-2004SIST ISO 11476:2004SLOVENSKI
STANDARD



SIST ISO 11476:2004



ReferencenumberISO11476:2000(E)©ISO2000INTERNATIONALSTANDARDISO11476Firstedition2000-11-15Paperandboard—DeterminationofCIEwhiteness,C/2°(indoorilluminationconditions)Papieretcarton—DéterminationdudegrédeblancCIE,C/2°(éclairageintérieur)SIST ISO 11476:2004



ISO11476:2000(E)PDFdisclaimerThisPDFfilemaycontainembeddedtypefaces.InaccordancewithAdobe'slicensingpolicy,thisfilemaybeprintedorviewedbutshallnotbeeditedunlessthetypefaceswhichareembeddedarelicensedtoandinstalledonthecomputerperformingtheediting.Indownloadingthisfile,partiesacceptthereintheresponsibilityofnotinfringingAdobe'slicensingpolicy.TheISOCentralSecretariatacceptsnoliabilityinthisarea.AdobeisatrademarkofAdobeSystemsIncorporated.DetailsofthesoftwareproductsusedtocreatethisPDFfilecanbefoundintheGeneralInforelativetothefile;thePDF-creationparameterswereoptimizedforprinting.EverycarehasbeentakentoensurethatthefileissuitableforusebyISOmemberbodies.Intheunlikelyeventthataproblemrelatingtoitisfound,pleaseinformtheCentralSecretariatattheaddressgivenbelow.©ISO2000Allrightsreserved.Unlessotherwisespecified,nopartofthispublicationmaybereproducedorutilizedinanyformorbyanymeans,electronicormechanical,includingphotocopyingandmicrofilm,withoutpermissioninwritingfromeitherISOattheaddressbeloworISO'smemberbodyinthecountryoftherequester.ISOcopyrightofficeCasepostale56CH-1211Geneva20Tel.+41227490111Fax+41227490947E-mailcopyright@iso.chWebwww.iso.chPrintedinSwitzerlandii©ISO2000–AllrightsreservedSIST ISO 11476:2004



ISO11476:2000(E)©ISO2000–AllrightsreservediiiContentsPageForeword.iv1Scope.12Normativereferences.13Termsanddefinitions.24Principle.35Apparatusandequipment.36Calibration.47Sampling.58Preparationoftestpieces.59Procedure.510Calculationandexpressionofresults.511Precision.612Testreport.7AnnexA(normative)Spectralcharacteristicsofreflectometersfordeterminingtristimulusvalues.8AnnexB(normative)UV-calibrationservice.11Bibliography.13SIST ISO 11476:2004



ISO11476:2000(E)iv©ISO2000–AllrightsreservedForewordISO(theInternationalOrganizationforStandardization)isaworldwidefederationofnationalstandardsbodies(ISOmemberbodies).TheworkofpreparingInternationalStandardsisnormallycarriedoutthroughISOtechnicalcommittees.Eachmemberbodyinterestedinasubjectforwhichatechnicalcommitteehasbeenestablishedhastherighttoberepresentedonthatcommittee.Internationalorganizations,governmentalandnon-governmental,inliaisonwithISO,alsotakepartinthework.ISOcollaboratescloselywiththeInternationalElectrotechnicalCommission(IEC)onallmattersofelectrotechnicalstandardization.InternationalStandardsaredraftedinaccordancewiththerulesgivenintheISO/IECDirectives,Part3.DraftInternationalStandardsadoptedbythetechnicalcommitteesarecirculatedtothememberbodiesforvoting.PublicationasanInternationalStandardrequiresapprovalbyatleast75%ofthememberbodiescastingavote.AttentionisdrawntothepossibilitythatsomeoftheelementsofthisInternationalStandardmaybethesubjectofpatentrights.ISOshallnotbeheldresponsibleforidentifyinganyorallsuchpatentrights.InternationalStandardISO11476waspreparedbyTechnicalCommitteeISO/TC6,Paper,boardandpulps.ItisbasedontheCIE-whitenessformula,publishedinCIEPublication15.2-1986,Colorimetry.AnnexesAandBformanormativepartofthisInternationalStandard.SIST ISO 11476:2004



INTERNATIONALSTANDARDISO11476:2000(E)©ISO2000–Allrightsreserved1Paperandboard—DeterminationofCIEwhiteness,C/2°(indoorilluminationconditions)1ScopeThisInternationalStandardspecifiestheproceduretobeusedfordeterminingthewhitenessofpapersandboards,inordertoobtainvalueswhichcorrespondtothevisualappearanceofwhitepapersandboards,withorwithoutfluorescentwhiteningagents,whentheyareviewedindoors.Itisbasedonradiancefactordataobtainedoverthefullvisiblespectralrange(VIS)incontrasttothemeasurementofISObrightness,whichislimitedtotheblueregionofVIS.Inaddition,itspecifiesamethodforadjustmentoftheUV-contenttocorrespondtotheCIEilluminantC[1][2],sincetheresultsobtainedwhenfluorescentwhiteningagentsarepresentaredependentupontheUV-contentoftheradiationfallinguponthesample.TheCIEilluminationCistakentoberepresentativeofindoorilluminationconditionsbecauseitcontainsasuitableproportionofUV-radiation[3][4].Thismethodisnotapplicabletocolouredpaperscontainingfluorescentdyes.Itisspecificforthesituationwherethefluorescenceoccursintheblueregionofthevisiblespectralrange.ThisInternationalStandardshouldbereadinconjunctionwithISO2469.NOTE1ItisrecognizedthattheCIE-whitenessequationwasdevelopedinthecontextoftheCIEstandardilluminantD65[10],butthesimilaritybetweentherelativespectralpowercurvesfortheCandD65illuminantswithinthevisibleregionandtheclosenessoftheircorrelatedcolourtemperatures(6770Kand6500Krespectively)istakenasajustificationfortheuseoftheanalogouswhitenessequationwiththeCIEilluminantC.NOTE2ArelatedInternationalStandard,ISO11475[13]specifiestheprocedureforobtainingvaluescorrespondingtotheappearanceofpapersviewedundertheCIEilluminantD65.2NormativereferencesThefollowingnormativedocumentscontainprovisionswhich,throughreferenceinthistext,constituteprovisionsofthisInternationalStandard.Fordatedreferences,subsequentamendmentsto,orrevisionsof,anyofthesepublicationsdonotapply.However,partiestoagreementsbasedonthisInternationalStandardareencouragedtoinvestigatethepossibilityofapplyingthemostrecenteditionsofthenormativedocumentsindicatedbelow.Forundatedreferences,thelatesteditionofthenormativedocumentreferredtoapplies.MembersofISOandIECmaintainregistersofcurrentlyvalidInternationalStandards.ISO186:1994,Paperandboard—Samplingtodetermineaveragequality.ISO2469,Paper,boardandpulps—Measurementofdiffusereflectancefactor.ISO2470,Paper,boardandpulps—Measurementofdiffusebluereflectancefactor(ISObrightness).SIST ISO 11476:2004



ISO11476:2000(E)2©ISO2000–Allrightsreserved3TermsanddefinitionsForthepurposesofthisInternationalStandard,thefollowingtermsanddefinitionsapply.3.1reflectancefactorRratiooftheradiationreflectedbyabodytothatreflectedbytheperfectreflectingdiffuserunderthesameconditionsNOTETheratioisusuallyexpressedasapercentage.3.2intrinsicreflectancefactorreflectivityRreflectancefactorofalayerorpadofthematerialthickenoughtobeopaque,i.e.suchthatincreasingthethicknessofthepadbydoublingthenumberofsheetsresultsinnochangeinthemeasuredreflectancefactor3.3radiancefactorratiooftheradianceofabodytothatoftheperfectreflectingdiffuserunderthesameconditionsofilluminationandviewingNOTEForfluorescent(luminescent)materials,thetotalradiancefactor,,isthesumoftwoportions,thereflectedradiancefactor,S,andtheluminescentradiancefactor,L,sothatSLFornon-fluorescentmaterials,thereflectedradiancefactor,Sissimplythereflectancefactor,R.3.4intrinsicradiancefactorradiancefactorofalayerorpadofthematerialthickenoughtobeopaque,i.e.suchthatincreasingthethicknessofthepadbydoublingthenumberofsheetsresultsinnochangeinthemeasuredradiancefactorNOTEForfluorescent(luminescent)materials,theintrinsictotalradiancefactor,isthesumoftwoportions,theintrinsicreflectedradiancefactor,,S,andtheintrinsicluminescentradiancefactor,,L,sothat,S,LFornon-fluorescentmaterials,theintrinsicreflectedradiancefactor,,S,issimplytheintrinsicreflectancefactorR.3.5CIEwhitenessWmeasureofwhitenessderivedfromtheCIEtristimulusvaluesdeterminedundertheconditionsspecifiedinthisInternationalStandard,andexpressedaswhitenessunits3.6green/redtintTwmeasureofthedeviationfromwhitenessofthetestmaterialtowardsthegreenorredregion,andexpressedastintunitsNOTEApositivevalueofTwindicatesagreenishtintandanegativevalueindicatesareddishtint.SIST ISO 11476:2004



ISO11476:2000(E)©ISO2000–Allrightsreserved33.7fluorescencecomponentWFmeasureoftheextenttowhichthewhitenessofthematerialisaffectedbyexcitationoftheaddedfluorescentwhiteningagent(FWA)undertheconditionsspecifiedinthisInternationalStandard4PrincipleThediffuseradiancefactorofthematerialisdeterminedunderstandardizedconditionsafteradjustmentoftheinstrumentsothattherelativeUV-contentoftheilluminationcorrespondstothatoftheCIEilluminantC,andtheCIEwhitenessandtintarecalculated.Thefluorescencecomponentofthewhitenessiscalculatedfromthedifferencebetweenthisdiffuse-radiance-factorvalueandthevalueobtainedwhenthefluorescenceemissionfromthematerialiseliminated,forinstancebytheintroductionintothelightbeamsofasharpcut-offUV-absorbingfilter.5Apparatusandequipment5.1Reflectometerorspectrophotometer,havingthegeometric,spectralandphotometriccharacteristicsdescribedinISO2469,calibratedinaccordancewiththeprovisionsofISO2469,andequippedwitharadiationsourcehavinganadequateUV-contentandameansofadjustingtherelativeUV-contentsothatthemeasuredISO-brightnessvalueagreeswiththeISO-brightnessvalueassignedtoafluorescentreferencestandard(5.2.2)andcorrespondingtotheCIEilluminantC[2][5][6].Ifafilter(theUV-adjustmentfilter)isusedtomakethisadjustment,itshallhaveacut-offvalueof395nmsothatitabsorbsUV-radiationbutdoesnotatthesametimealterthevisiblespectrumwithinthesphere.NOTE1Inthe1994editionofISO2469,thereflectometercharacteristicsaredescribedinannexAandthecalibrationserviceisdescribedinannexB.WhenISO2469isrevised,thenumberingmaychange;usersofeditionssubsequentto1994shouldthereforedeterminewhichelementsoftextspecifythesecharacteristicsandthisservice.NOTE2InordertoachieveconcordancebetweentheconditionsformeasuringbothISObrightnessandCIEwhiteness(C/2°),anadjustmentbasedonareferencestandardhavinganassignedISO-brightnessvalueispreferred.Forthemeasurementofreflectancefactorswiththefluorescenceeffecteliminated,theinstrumentshallbeequippedwithasharp-cut-off,UV-absorbingfilter(theUV-cut-offfilter)havingatransmittancenotexceeding5,0%atandbelowawavelengthof410nmandnotexceeding50%atawavelengthof420nm.Thecut-offfiltershallhavecharacteristicssuchthatareliablereflectance-factorvalueisobtainedat420nm.Thereflectance-factorvalueobtainedat420nmshallthenbeconsideredforcomputationalpurposestobethevalue,whichappliesatalllowerwavelengths,atwhichitisnotpossibletomakeanymeasurement.Forthemeasurementoffluorescentpapers,photometriclinearityuptoascalereadingofatleast200%isnecessaryinthewavelengthregioncorrespondingtothefluorescentemission.5.1.1Inthecaseofafilterreflectometer,pairsoffiltersgivingthephotoelectricdetectorsofthereflectometerresponsesequivalenttotheCIEtristimulusvaluesX,Y,Zofthetestpiece[7],evaluatedfortheCIEilluminantC[6]andCIE1931(2°)observer[8].5.1.2Inthecaseofanabridgedspectrophotometer,ameansofcalculatingtheweightedmeansaccordingtotherequirementsoftheCIEilluminantCandCIE1931(2°)observerusingtheweightingfunctionsgiveninannexA.5.2Referencestandardsforcalibrationoftheinstrumentandworkingstandards5.2.1Non-fluorescentreferencestandardforcalibration,fulfillingtherequirementsforISOreferencestandardsoflevel3asprescribedinISO2469.5.2.2FluorescentreferencestandardforuseinadjustingtheUV-contentoftheradiationincidentuponthesample,havinganassignedISO-brightnessvalueasspecifiedinannexBandfulfillingtherequirementsforISOreferencestandardsoflevel3.UsenewreferencestandardssufficientlyfrequentlytoensuresatisfactorycalibrationandUV-adjustment.SIST ISO 11476:2004



ISO11476:2000(E)4©ISO2000–Allrightsreserved5.3Workingstandards5.3.1Twoplatesofflatopalglassorceramicmaterial,cleanedasdescribedinISO2469.5.3.2Astableplasticorothertabletincorporatingafluorescentwhiteningagent.5.4Blackcavity,havingareflectancefactorwhichdoesnotdifferfromitsnominalvaluebymorethan0,2%,atallwavelengths.Theblackcavityshouldbestoredupsidedowninadust-freeenvironmentorwithaprotectivecover.NOTETheconditionoftheblackcavityshouldbecheckedbyreferencetotheinstrumentmaker.6Calibration6.1Usingthevaluesassignedtothenon-fluorescentreferencestandard(5.2.1),calibratetheinstrumentwiththeUV-cut-offfiltersremovedfromtheradiationbeams.ThesettingoftheUV-adjustmentfilterisnotimportantatthisstage.6.2Usingtheappropriatemeasurementprocedure,measurethereflectanceofthefluorescentreferencestandard(5.2.2),determinetheISO-brightnessvalueasdescribedinISO2470andcomparethevalueobtainedwiththatassignedtothefluorescentreferencestandard.AmeasuredISO-brightnessvaluehigherthantheassignedvalueindicatesthattherelativeUV-contentoftheilluminationistoohighandalowervalueindicatesthattherelativeUV-contentistoolow.6.3UsingtheUV-adjustmentfilterorotheradjustme
...

NORME ISO
INTERNATIONALE 11476
Première édition
2000-11-15
Papier et carton — Détermination du degré
de blanc CIE, C/2° (éclairage intérieur)
Paper and board — Determination of CIE whiteness, C/2° (indoor
illumination conditions)
Numéro de référence
ISO 11476:2000(F)
©
ISO 2000

---------------------- Page: 1 ----------------------
ISO 11476:2000(F)
PDF – Exonération de responsabilité
Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier peut
être imprimé ou visualisé, mais ne doit pas être modifiéà moins que l'ordinateur employéà cet effet ne bénéficie d'une licence autorisant
l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées acceptent de fait la
responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute responsabilité en la
matière.
Adobe est une marque déposée d'Adobe Systems Incorporated.
Les détails relatifs aux produits logiciels utilisés pour la créationduprésent fichier PDF sont disponibles dans la rubrique General Info du
fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir l'exploitation de
ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation, veuillez en informer le
Secrétariat central à l'adresse donnée ci-dessous.
© ISO 2000
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous quelque
forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit de l’ISO à
l’adresse ci-aprèsouducomité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 � CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax. + 41 22 749 09 47
E-mail copyright@iso.ch
Web www.iso.ch
Imprimé en Suisse
ii © ISO 2000 – Tous droits réservés

---------------------- Page: 2 ----------------------
ISO 11476:2000(F)
Sommaire Page
Avant-propos.iv
1 Domaine d’application .1
2Références normatives .1
3Termesetdéfinitions.2
4 Principe.3
5 Appareillage et équipement.3
6 Étalonnage.4
7 Échantillonnage .5
8Préparation des éprouvettes .5
9 Mode opératoire.5
10 Calcul et expression des résultats.6
11 Fidélité .7
12 Rapport d'essai .7
Annexe A (normative) Caractéristiques spectrales des réflectomètres pour la détermination des
composantes trichromatiques .8
Annexe B (normative) Service d'étalonnage UV.11
Bibliographie .13
© ISO 2000 – Tous droits réservés iii

---------------------- Page: 3 ----------------------
ISO 11476:2000(F)
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiéeaux
comités techniques de l'ISO. Chaque comité membre intéressé par une étude aledroit de fairepartie ducomité
technique créé à cet effet. Les organisations internationales, gouvernementales et non gouvernementales, en
liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec la Commission
électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI, Partie 3.
Les projets de Normes internationales adoptés par les comités techniques sont soumis aux comités membres pour
vote. Leur publication comme Normes internationales requiert l'approbation de 75 % au moins des comités
membres votants.
L’attention est appelée sur le fait que certains des éléments delaprésente Norme internationale peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable de
ne pas avoir identifié de tels droits de propriété et averti de leur existence.
La Norme internationale ISO 11476 a étéélaboréepar le comité technique ISO/TC 6, Papiers, cartons et pâtes.
Elle est basée sur la formule du degré de blanc CIE, donnée dans la publication CIE 15.2-1986, Colorimétrie.
Les annexes A et B constituent des éléments normatifs de la présente Norme internationale.
iv © ISO 2000 – Tous droits réservés

---------------------- Page: 4 ----------------------
NORME INTERNATIONALE ISO 11476:2000(F)
Papier et carton — Détermination du degré de blanc CIE, C/2°
(éclairage intérieur)
1 Domaine d’application
La présente Norme internationale spécifie le mode opératoire à utiliser pour déterminer le degré de blanc des
papiers et cartons, afin d’obtenir des valeurs correspondant à l'aspect visuel des papiers et cartons blancs, avec ou
sans agents d'azurage fluorescents, lorsqu'ils sont observés à l’intérieur. Elle est basée sur des valeurs de facteur
de rayonnement obtenues pour toute l'étendue du spectre visible, au contraire du mesurage de degré de blancheur
ISO qui est limitéà la région bleue du spectre visible.
En outre, elle prescrit une méthode permettant de régler la teneur en UV afin qu'elle corresponde à l'illuminant
[1] [2]
CIE C , puisque les valeurs obtenues avec les agents d'azurage fluorescents dépendent de la teneur en UV du
rayonnement arrivant sur l'échantillon. L'illuminant CIE C est considéré comme étant représentatif des conditions
[3] [4]
d’éclairage intérieur, puisqu’il contient une quantité adéquate de radiation UV . Cette méthode ne convient pas
aux papiers de couleur contenant des colorants fluorescents. Elle est applicable dans le cas où la fluorescence
intervient dans la région bleue de l’étendue du spectre visible.
La présente Norme internationale doit être lue conjointement avec l'ISO 2469.
NOTE 1 Il a été reconnu que l’équationdudegré de blanc CIE a été développée dans le contexte de l’illuminant normalisé
[10]
CIE D65 , mais la similarité entre les courbes de puissance spectrale relative pour les illuminants C et D65 dans le visible et
la proximité des températures de couleur correspondantes (6 770 K et 6 500 K respectivement) sont considérées comme
justifiant l’utilisation de l’équation analogue de degré de blanc avec l’illuminant CIE C.
[13]
NOTE 2 Une Norme internationale apparentée, l’ISO 11475 ,spécifie le mode opératoire pour obtenir les valeurs
correspondant à l’aspect des papiers sous l’illuminant CIE D65.
2Références normatives
Les documents normatifs suivants contiennent des dispositions qui, par suite de la référence qui y est faite,
constituent des dispositions valables pour la présente Norme internationale. Pour les références datées, les
amendements ultérieurs ou les révisions de ces publications ne s’appliquent pas. Toutefois, les parties prenantes
aux accords fondés sur la présente Norme internationale sont invitées à rechercher la possibilité d'appliquer les
éditions les plus récentes des documents normatifs indiqués ci-après. Pour les références non datées, la dernière
édition du document normatif en référence s’applique. Les membres de l'ISO et de la CEI possèdent le registre des
Normes internationales en vigueur.
ISO 186:1994, Papier et carton—Échantillonnage pour déterminer la qualité moyenne.
ISO 2469, Papier, carton et pâtes — Mesurage du facteur de réflectance diffuse.
ISO 2470, Papier, carton et pâtes — Mesurage du facteur de réflectance diffuse dans le bleu (degré de blancheur
ISO).
© ISO 2000 – Tous droits réservés 1

---------------------- Page: 5 ----------------------
ISO 11476:2000(F)
3 Termes et définitions
Pour les besoins de la présente Norme internationale, les termes et définitions suivants s'appliquent.
3.1
facteur de réflectance
R
rapport du rayonnement réfléchi par un corps au rayonnement réfléchi dans les mêmes conditions par le diffuseur
parfait par réflexion
NOTE Le facteur de réflectance est exprimé habituellement en pourcentage.
3.2
facteur de réflectance intrinsèque
R

facteur de réflectance d'une couche ou d'une liasse de matériau suffisamment épaisse pour être opaque, c'est-à-
dire telle que l'augmentation de l'épaisseur de la liasse, en doublant le nombre de feuilles la constituant,
n'engendre aucune modification du facteur de réflectance mesuré
3.3
facteur de rayonnement

rapport du rayonnement d’un corps à celui du diffuseur parfait par réflexion, dans les mêmes conditions d’éclairage
et d’observation
NOTE Pour les matériaux fluorescents (luminescents), le facteur de rayonnement total,�, est la somme de deux parties, le
facteur de rayonnement réfléchi,� , et le facteur de rayonnement luminescent,� :
S L
� =� +�
S L
Pour les matériaux non fluorescents, le facteur de rayonnement réfléchi,� , est simplement le facteur de réflectance, R.
S
3.4
facteur de rayonnement intrinsèque


facteur de rayonnement d'une couche ou d'une liasse de matériau suffisamment épaisse pour être opaque, c'est-à-
dire telle que l'augmentation de l'épaisseur de la liasse, en doublant le nombre de feuilles la constituant,
n'engendre aucune modification du facteur de rayonnement mesuré
NOTE Pour les matériaux fluorescents (luminescents), le facteur de rayonnement total intrinsèque, � , est la somme de

deux parties, le facteur de rayonnement réfléchi intrinsèque,� , et le facteur de rayonnement luminescent intrinsèque,� :
�,S �,L
� =� +�
� �,S �,L
Pour les matériaux non fluorescents, le facteur de rayonnement réfléchi intrinsèque, � , est simplement le facteur de
�,S
réflectance intrinsèque, R .

3.5
degré de blanc CIE
W
mesure de degré de blanc, dérivée des composantes trichromatiques CIE déterminées dans les conditions
spécifiées dans la présente Norme internationale, et expriméeen unités de degré de blanc
3.6
teinte vert/rouge
T
w
mesure de la déviation de degré de blanc du matériau soumis à l'essai vers la région du vert ou du rouge, et
expriméeenunités de teinte
NOTE Une valeur positive de T indique une teinte tirant sur le vert, et une valeur négative une teinte tirant sur le rouge.
w
2 © ISO 2000 – Tous droits réservés

---------------------- Page: 6 ----------------------
ISO 11476:2000(F)
3.7
composante de fluorescence
W
F
mesure de l'importance de la modification du degré de blanc du matériau par l'excitation des agents d'azurage
fluorescents ajoutés, dans les conditions spécifiées dans la présente Norme internationale
4Principe
On détermine le facteur de rayonnement diffus du matériau dans des conditions normalisées aprèsréglage de
l'appareil, de sorte que la teneur relative de l'éclairage en UV corresponde à celle de l'illuminant CIE C, et l'on
calculeledegré de blanc CIE et la teinte. La composante de fluorescence de degré de blanc est calculée comme
étant la différence entre la valeur du facteur de rayonnement diffus et la valeur obtenue après élimination de
l'émission fluorescente du matériau, par exemple en insérant dans les faisceaux lumineux un filtre absorbant les
UV, à coupure nette.
5 Appareillage et équipement
5.1 Réflectomètre ou spectrophotomètre, ayant les caractéristiques géométriques, spectrales et
photométriques décrites dans l'ISO 2469, étalonné conformément aux dispositions de l'ISO 2469, et équipé d'une
source de rayonnement à teneur adéquate en UV et d'un moyen de réglage de la teneur relative en UV, de sorte
que la valeur mesuréede degré de blancheur ISO concorde avec la valeur de degré de blancheur ISO assignée à
[2][5][6]
un étalonderéférence fluorescent (5.2.2), et correspondant à l'illuminant CIE C . Si un filtre (le filtre de
réglage de teneur en UV) est utilisé pour faire ce réglage, il doit avoir une coupure nette à 395 nm, afin d'absorber
toute radiation UV sans altérer le spectre visible à l’intérieur de la sphère.
NOTE 1 Dans l'édition 1994 de l'ISO 2469, les caractéristiques du réflectomètre sont décrites dans l'annexe A et le service
d'étalonnage dans l'annexe B. Quand l'ISO 2469 sera révisée, la numérotation pourrait changer; il convient que les utilisateurs
des éditions publiées après 1994 déterminent quelles parties du texte spécifient ces caractéristiques et ce service.
NOTE 2 Afin d'obtenir une concordance entre les conditions pour mesurer le degré de blancheur ISO et le degré de blanc
CIE (C/2°), un ajustement basé sur un étalon de référence qui a une valeur assignéededegré de blancheur ISO est préférable.
Pour le mesurage des facteurs de réflectance après élimination de la fluorescence, l'appareil doit être équipé d'un
filtre absorbant les UV, de coupure nette, dont le facteur de transmission n'excède pas 5,0 % à une longueur
d'onde inférieure ou égale à 410 nm, et pas plus de 50 % à une longueur d'onde de 420 nm. Le filtre à coupure doit
avoir des caractéristiques telles qu'une valeur sûre soit obtenue à 420 nm. La valeur du facteur de réflectance
obtenue à 420 nm doit alors être considérée pour les calculs comme la valeur applicable à toutes les longueurs
d'onde inférieures, pour lesquelles il est impossible de faire aucune mesure.
Pour le mesurage des papiers fluorescents, il est nécessaire d'avoir une linéarité photométrique, au moins jusqu'à
la graduation 200 % dans la région des longueurs d'onde correspondant à l'émission fluorescente.
5.1.1 Pour les réflectomètres à filtres, paires de filtres donnant aux cellules photoélectriques des réflectomètres
[7]
des réponses équivalentes aux composantes trichromatiques CIE X, Y, Z de l'éprouvette , évaluées pour
[6] [8]
l'illuminant normalisé CIE C et l’observateur CIE 1931 (2°) .
5.1.2 Pour les spectrophotomètres avec un nombre discret de longueurs d'onde, moyen permettant de calculer
les moyennes pondérées selon les prescriptions relatives à l'illuminant CIE C et à l'observateur CIE 1931 (2°)en
utilisant les fonctions de pondération données dans l'annexe A.
5.2 Étalons de référence pour l’étalonnage de l’appareil et des références de travail
5.2.1 Étalon de référence non fluorescent pour l'étalonnage, conforme aux exigences relatives aux références
ISO de niveau 3, comme prescrit dans l'ISO 2469.
5.2.2 Étalon de référence fluorescent destiné au réglage de la teneur en UV du rayonnement incident sur
l'échantillon, ayant une valeur de degré de blancheur ISO comme spécifié dans l'annexe B et conforme aux
exigences relatives aux références ISO de niveau 3.
© ISO 2000 – Tous droits réservés 3

---------------------- Page: 7 ----------------------
ISO 11476:2000(F)
Renouveler les étalons de référence suffisamment souvent, afin d'assurer un étalonnage et un réglage de la teneur
en UV satisfaisants.
5.3 Étalons de travail
5.3.1 Deux plaques planes de verre opale ou céramique, nettoyées conformément à l'ISO 2469.
5.3.2 Tablette de plastique stable ou d'un autre matériau stable contenant un agent d'azurage fluorescent.
5.4 Corps noir, dont le facteur de réflectance ne varie pas de plus de 0,2 % par rapport à la valeur nominale, à
toutes les longueurs d'onde. Il est recommandé d'entreposer le corps noir, côté supérieur en dessous, dans un
environnement exempt de poussière, ou sous un couvercle protecteur.
NOTE Il convient de vérifier l'état du corps noir en se conformant aux instructions du fabricant de l'appareil.
6 Étalonnage
6.1 En utilisant les valeurs assignées à l'étalonderéférence non fluorescent (5.2.1), étalonner l'appareil après
avoir retiré des faisceaux lumineux les filtres anti-UV. La position du filtre de réglage de la teneur en UV n'est pas
importante à ce stade.
6.2 En utilisant le mode opératoire de mesurage approprié, mesurer la réflectance de l'étalonderéférence
fluorescent (5.2.2), déterminer sa valeur de degré de blancheur ISO comme indiqué dans I'ISO 2470, et comparer
la valeur obtenue avec celle assignée à l'étalon de référence fluorescent.
Une valeur de degré de blancheur ISO mesurée, plus élevée que la valeur assignée, signifie que la teneur relative
en UV de l'éclairage est trop élevée, tandis qu'une valeur mesurée, inférieure à la valeur assignée, signifie que la
teneur relative en UV est trop basse.
6.3 En utilisant le filtre de réglage de la teneur en UV ou un autre dispositif de réglage, régler la teneur en UV de
l'éclairage de façon à obtenir la valeur correcte de degré de blancheur ISO.
6.4 Répéter l'étalonnage décrit en 6.1 en utilisant l'étalon non fluorescent (5.2.1), avec le filtre de réglage de la
teneur en UV dans la position pour laquelle la valeur correcte de degré de blancheur ISO a été obtenue pour
l'étalon de référence fluorescent. Répéter le mesurage de degré de blancheur de l'étalon fluorescent (5.2.2)
comme décrit en 6.2. Si la valeur de blancheur ISO obtenue ne concorde pas avec la valeur assignée, régler la
position du filtre jusqu'à obtention de la valeur correcte de blancheur ISO conformément à 6.3.
6.5 Répéter la procédure décriteen6.4 jusqu'à obtention de la valeur correcte de degré de blancheur ISO avec
l'appareil étalonné correctement avec l'étalon non fluorescent. La teneur en UV est maintenant réglée correctement
par rapport au degré de blancheur, à une teneur relative en UV équivalente à l'illuminant CIE C. Noter la position
de réglage de la teneur en UV.
NOTE 1
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.