Abstract

The present document gives an introduction and overview of the complete Digital Enhanced Cordless Telecommunications (DECT) Common Interface (CI). This part of the DECT CI specifies the speech coding and transmission requirements. In order to ensure satisfactory interworking of different portable and fixed units, it is necessary to specify the transmission performance of the analogue information over the digital link. This requires not only use of a common speech algorithm, but also standardization of frequency responses, reference speech levels (or loudness) at the air interface and various other parameters. The present document applies to DECT equipment which includes all the necessary functions to provide real-time two-way speech conversation. A 3,1 kHz telephony teleservice conveyed over a DECT link (including Fixed Part (FP) and Portable Part (PP)) which is capable of being connected (directly or indirectly) to the public network access point should comply with the requirements in the present document. Tethered fixed point local loop applications are not required to comply with the requirements of the present document. The speech performance characteristics defined in the present document typically conform to TBR 008 (see bibliography), which specifies the overall performance between the handset acoustic interface and a 64 kbit/s A-law Pulse Code Modulated (PCM) digital network interface. The deviations from TBR 008 are mainly due to the consequences of non-PCM coding and transmission delay.
The additional features described in clause 8 are those which are not included in TBR 008, but which are likely to occur in a DECT system: analogue interface, loudspeaking and hand-free facilities, tandeming with a mobile radio network. Headsets are not covered by the present specifications. For the DECT systems which connect to the Public Switched Telephone Network (PSTN) via an analogue interface, the additional requirements, which are implemented in the FP, have as much as possible been aligned with TBR 038 (see bibliography).
A summary of the control and the use of the DECT echo control functions, to guide on need for options to manufacturers and installers, is found in annex A. Information concerning test methods can be found in EN 300 176 [3]. The test methods take into account that DECT is a digital system.

Status
Published
Publication Date
28-Feb-2006
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Mar-2006
Due Date
01-Mar-2006
Completion Date
01-Mar-2006

Buy Documents

Standard

SIST EN 300 175-8 V1.9.1:2006

English language (39 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN 300 175-8 V1.9.1:2006 is the Slovenian adoption of ETSI EN 300 175-8 V1.9.1 for Digital Enhanced Cordless Telecommunications (DECT) Common Interface (CI), Part 8: Speech coding and transmission. It specifies the speech coding, transmission performance, loudness, delay, echo control and related speech-quality requirements for DECT equipment that supports real-time two-way speech, especially equipment that connects to the public network.

What does SIST EN 300 175-8 V1.9.1:2006 specify?

SIST EN 300 175-8 V1.9.1:2006 specifies the speech coding and transmission requirements for DECT equipment. It focuses on the Portable Part (PP) and Fixed Part (FP) interface behavior so that different units can interwork in practice.

The scope covers DECT systems used for real-time two-way speech conversation and a 3,1 kHz telephony teleservice over a DECT link that can connect directly or indirectly to a public network access point. Tethered fixed point local loop applications are outside the compliance target for this part, and headsets are not covered.

The document is organized into clauses 1 to 8, with informative annexes A to F.

AnnexWhat it covers
Annex ADescription of "reference" echo control devices
Annex BLocal loop application
Annex CGSM Discontinuous Transmission (DTX) and Voice Activity Detection (VAD)
Annex DSpeech levels in relation to ambient room noise and examples of adaptive volume control settings
Annex EBibliography
Annex FChange history

What are the key requirements of SIST EN 300 175-8 V1.9.1:2006?

The key requirements define how DECT speech shall be coded, transmitted, measured and controlled across the PP, FP and network interfaces. They matter because they determine whether a handset sounds natural, avoids feedback and echo, and behaves predictably when connected to different fixed networks.

Speech coding and bit sequence

Clause 5 requires the speech coding algorithm to conform to ITU-T Recommendation G.726 for 32 kbit/s Adaptive Differential Pulse Code Modulation (ADPCM). The ADPCM words in each burst shall be sent in chronological order, with the most significant bit first.

In practice, this fixes the codec behavior at the air interface and helps ensure that different implementations interoperate. Clause 5 also says that if a new coding scheme is introduced, frequency response, distortion, delay, and possibly terminal coupling loss and network echo control need review.

Frequency response, loudness and volume control

Clause 7 sets masks for PP sending and receiving frequency response, and nominal values for Sending Loudness Rating (SLR) and Receiving Loudness Rating (RLR). The nominal values are SLR 8 dB and RLR 2 dB, with manufacturing tolerance on both.

A user-controlled volume control is required in the PP unless adaptive volume control is incorporated. The setting range has to change RLR by at least 6 dB from nominal to maximum, and the equipment has to meet the loudness requirements at one setting. This matters because users need enough receive level in noise, but not so much that the connection becomes distorted or unstable.

Clause 7.2 also allows adaptive volume control in the PP or FP, with the FP using environmental noise information from the PP. Annex D gives example settings related to room noise.

Sidetone, coupling loss, distortion, noise and delay

Clause 7 requires the talker sidetone path in the PP and gives a nominal Sidetone Masking Rating (STMR) of 13 dB. Listener sidetone is not mandatory, but the document gives recommended values, especially for PPs with declared noise rejection capability.

Clause 7.4 sets Weighted Terminal Coupling Loss (TCLw) requirements, including a 3,1 kHz service option for the PP and echo-control options for FPs. Clause 7.4.2 requires stability loss of at least 6 dB over 200 Hz to 4 000 Hz under the stated test conditions.

Clause 7.5 limits distortion, clause 7.7 limits noise, clause 7.8 limits acoustic shock, and clause 7.9 limits round-trip delay. These requirements matter together because they control intelligibility, feedback risk, comfort and speech timing.

Echo control and public network interfaces

Clause 7.10 defines network echo control requirements with two delay-dependent cases. The FP shall insert enough echo loss to meet the requirement, and the function shall be connectable or disableable depending on routing information and service type.

Clause 7.12 adds requirements for DECT systems with a 2-wire PSTN interface. These requirements are aligned as far as possible with TBR 038 and apply to complete systems or to a separate FP tested with a Reference Portable Part (RePP). The clause covers polarity independence, feed conditions, power supply, sensitivity and frequency response, SLR and RLR, distortion, noise and Echo Return Loss.

Additional features and special cases

Clause 8 covers optional or special configurations such as loudspeaking and hand-free facilities, tandeming with a mobile radio network, DECT connected to the GSM fixed network, and Wireless Relay Stations (WRS). For GSM tandem cases, the document sets echo control and Terminal Coupling Loss rules, including a Discontinuous Transmission (DTX) case.

For WRS cascades, clause 8.4 notes incremental delay and gives modified FP echo-control requirements when 2 or 3 Cordless Radio Fixed Part (CRFP) links are cascaded. This is important for planning multi-hop deployments.

What terms does SIST EN 300 175-8 V1.9.1:2006 define?

  • ADPCM - Adaptive Differential Pulse Code Modulation, the 32 kbit/s speech coding method required by this part.
  • PP - Portable Part, the DECT user unit that contains the handset-side speech functions.
  • FP - Fixed Part, the network-side DECT unit that handles the line interface and echo control.
  • SLR - Sending Loudness Rating, the sending-level measure used for speech transmission balance.
  • RLR - Receiving Loudness Rating, the receive-level measure used to set loudness and volume behavior.
  • TCLw - weighted Terminal Coupling Loss, the loss measure used to assess stability and echo performance.
  • STMR - Sidetone Masking Rating, the measure for how much the talker hears their own voice in the handset.
  • DTX - Discontinuous Transmission, the speech transmission mode used in GSM tandem cases.

Who uses SIST EN 300 175-8 V1.9.1:2006?

DECT handset and base-station manufacturers use this standard when designing codec behavior, acoustic interfaces, volume control and echo control. Test laboratories use it to verify speech performance, delay, noise, distortion and network-attachment behavior.

Network operators, system integrators and installers use it when DECT equipment must connect to PSTN, ISDN, GSM or local-loop environments. Quality managers and buyers use it to check that a DECT product supports the speech path and interface type they need, and that it can be tested as a complete system or as separate FP and PP equipment.

What changed in SIST EN 300 175-8 V1.9.1:2006 from the previous edition?

Annex F records that V1.9.1 aligns the document with ITU-T recommendations by using the Equipment Impairment Factor from the E-Model instead of quantization distortion, introduces more flexible rules for echo cancelling, and aligns PP sending and receiving loudness ratings with other wireless-terminal standards. The history table also records earlier updates in the series, including the addition of higher data-rate support with 16 QAM/64 QAM modulation and the Turbo Code Principle, and a later compatibility alignment with the other parts of the DECT series.

Which standards are used with SIST EN 300 175-8 V1.9.1:2006?

StandardWhat it contributes
ETSI EN 300 175-1Overview of the DECT Common Interface series
ETSI EN 300 175-5Network layer, including terminal capability and control information used by this part
ETSI EN 300 176 (all parts)Test specification for DECT, including speech tests
ITU-T G.701Vocabulary of digital transmission and PCM terms
ITU-T G.72632 kbit/s ADPCM codec requirement
ITU-T P.10Telephone transmission quality terminology
ITU-T P.340Hands-free terminal transmission characteristics
ITU-T G.111Loudness ratings in an international connection
ETSI ETS 300 540GSM speech transmission planning reference used for GSM tandem cases

What does the SIST EN 300 175-8 V1.9.1:2006 document contain?

The document contains reference configurations, functional block diagrams and test configurations for PP and FP speech paths. It also contains frequency masks, loudness values, echo-control conditions, delay limits, distortion limits, noise limits and out-of-band discrimination requirements.

Several clauses point to practical implementation choices, such as user volume control, adaptive volume control, artificial echo paths, soft suppressors and echo cancellers. Annex A gives guidance examples for echo control devices, Annex B explains a local loop replacement case, Annex C explains GSM DTX and VAD behavior, and Annex D gives example volume-control settings for noisy environments.

The figures and tables are used for design verification, type approval testing and transmission planning. In practice, the document tells engineers what to measure, how to compare the result with the required masks or limits, and how to configure the equipment during testing.

Buy Documents

Standard

SIST EN 300 175-8 V1.9.1:2006

English language (39 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

SIST EN 300 175-8 V1.9.1:2006 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI); Part 8: Speech coding and transmission". This standard covers: The present document gives an introduction and overview of the complete Digital Enhanced Cordless Telecommunications (DECT) Common Interface (CI). This part of the DECT CI specifies the speech coding and transmission requirements. In order to ensure satisfactory interworking of different portable and fixed units, it is necessary to specify the transmission performance of the analogue information over the digital link. This requires not only use of a common speech algorithm, but also standardization of frequency responses, reference speech levels (or loudness) at the air interface and various other parameters. The present document applies to DECT equipment which includes all the necessary functions to provide real-time two-way speech conversation. A 3,1 kHz telephony teleservice conveyed over a DECT link (including Fixed Part (FP) and Portable Part (PP)) which is capable of being connected (directly or indirectly) to the public network access point should comply with the requirements in the present document. Tethered fixed point local loop applications are not required to comply with the requirements of the present document. The speech performance characteristics defined in the present document typically conform to TBR 008 (see bibliography), which specifies the overall performance between the handset acoustic interface and a 64 kbit/s A-law Pulse Code Modulated (PCM) digital network interface. The deviations from TBR 008 are mainly due to the consequences of non-PCM coding and transmission delay. The additional features described in clause 8 are those which are not included in TBR 008, but which are likely to occur in a DECT system: analogue interface, loudspeaking and hand-free facilities, tandeming with a mobile radio network. Headsets are not covered by the present specifications. For the DECT systems which connect to the Public Switched Telephone Network (PSTN) via an analogue interface, the additional requirements, which are implemented in the FP, have as much as possible been aligned with TBR 038 (see bibliography). A summary of the control and the use of the DECT echo control functions, to guide on need for options to manufacturers and installers, is found in annex A. Information concerning test methods can be found in EN 300 176 [3]. The test methods take into account that DECT is a digital system.

The present document gives an introduction and overview of the complete Digital Enhanced Cordless Telecommunications (DECT) Common Interface (CI). This part of the DECT CI specifies the speech coding and transmission requirements. In order to ensure satisfactory interworking of different portable and fixed units, it is necessary to specify the transmission performance of the analogue information over the digital link. This requires not only use of a common speech algorithm, but also standardization of frequency responses, reference speech levels (or loudness) at the air interface and various other parameters. The present document applies to DECT equipment which includes all the necessary functions to provide real-time two-way speech conversation. A 3,1 kHz telephony teleservice conveyed over a DECT link (including Fixed Part (FP) and Portable Part (PP)) which is capable of being connected (directly or indirectly) to the public network access point should comply with the requirements in the present document. Tethered fixed point local loop applications are not required to comply with the requirements of the present document. The speech performance characteristics defined in the present document typically conform to TBR 008 (see bibliography), which specifies the overall performance between the handset acoustic interface and a 64 kbit/s A-law Pulse Code Modulated (PCM) digital network interface. The deviations from TBR 008 are mainly due to the consequences of non-PCM coding and transmission delay. The additional features described in clause 8 are those which are not included in TBR 008, but which are likely to occur in a DECT system: analogue interface, loudspeaking and hand-free facilities, tandeming with a mobile radio network. Headsets are not covered by the present specifications. For the DECT systems which connect to the Public Switched Telephone Network (PSTN) via an analogue interface, the additional requirements, which are implemented in the FP, have as much as possible been aligned with TBR 038 (see bibliography). A summary of the control and the use of the DECT echo control functions, to guide on need for options to manufacturers and installers, is found in annex A. Information concerning test methods can be found in EN 300 176 [3]. The test methods take into account that DECT is a digital system.

SIST EN 300 175-8 V1.9.1:2006 is classified under the following ICS (International Classification for Standards) categories: 33.070.30 - Digital Enhanced Cordless Telecommunications (DECT). The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 300 175-8 V1.9.1:2006 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 References
  • 8 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 3 Symbols and abbreviations
  • 3.1 Symbols
  • 3.2 Abbreviations
  • 9 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 4 Configurations
  • 4.1 Reference configuration
  • 10 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 11 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 0 A/D
  • 12 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 13 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 4.2 Test configurations
  • 5 Encoding
  • 5.2 Other codings
  • 14 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 6 Transmission aspects
  • 6.1 Relative level
  • 6.2 Acoustic reference level
  • 6.3 Volume control
  • 7 Speech performance characteristics
  • 7.1 PP frequency responses
  • 15 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 7.2 PP sending and receiving loudness ratings
  • 16 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 7.3 Sidetone
  • 17 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 7.4 Terminal coupling loss
  • 18 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 19 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 7.5 Distortion
  • 7.6 Out of band signals
  • 20 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 7.7 Noise
  • 7.8 Acoustic shock
  • 21 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 7.9 Delay
  • 7.10 Network echo control
  • 22 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 7.11 PP ambient noise rejection
  • 7.12 Additional requirements for DECT systems provided with a
  • 23 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 8 Additional features
  • 8.1 Loudspeaking and hand-free facilities
  • 8.2 Tandem with mobile radio network
  • 24 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 8.3 DECT connected to the GSM fixed network
  • 25 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 8.4 Wireless Relay Stations (WRS)
  • 26 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 27 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 28 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 29 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 30 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 31 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 32 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 33 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 34 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 35 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 36 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 37 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • Bibliography
  • 38 ETSI EN 300 175-8 V1.9.1 (2005-09)
  • 39 ETSI EN 300 175-8 V1.9.1 (2005-09)

1 Scope

The present document gives an introduction and overview of the complete Digital Enhanced Cordless Telecommunications (DECT) Common Interface (CI).

This part of the DECT CI specifies the speech coding and transmission requirements. In order to ensure satisfactory interworking of different portable and fixed units, it is necessary to specify the transmission performance of the analogue information over the digital link. This requires not only use of a common speech algorithm, but also standardization of frequency responses, reference speech levels (or loudness) at the air interface and various other parameters.

The present document applies to DECT equipment which includes all the necessary functions to provide real-time two-way speech conversation. A 3,1 kHz telephony teleservice conveyed over a DECT link (including Fixed Part (FP) and Portable Part (PP)) which is capable of being connected (directly or indirectly) to the public network access point should comply with the requirements in the present document.

Tethered fixed point local loop applications are not required to comply with the requirements of the present document. The speech performance characteristics defined in the present document typically conform to TBR 008 (see bibliography), which specifies the overall performance between the handset acoustic interface and a 64 kbit/s A-law Pulse Code Modulated (PCM) digital network interface. The deviations from TBR 008 are mainly due to the consequences of non-PCM coding and transmission delay.

The additional features described in clause 8 are those which are not included in TBR 008, but which are likely to occur in a DECT system: analogue interface, loudspeaking and hand-free facilities, tandeming with a mobile radio network. Headsets are not covered by the present specifications.

For the DECT systems which connect to the Public Switched Telephone Network (PSTN) via an analogue interface, the additional requirements, which are implemented in the FP, have as much as possible been aligned with TBR 038 (see bibliography).

A summary of the control and the use of the DECT echo control functions, to guide on need for options to manufacturers and installers, is found in annex A.

Information concerning test methods can be found in EN 300 176 [3]. The test methods take into account that DECT is a digital system.

2 References

The following documents contain provisions which, through reference in this text, constitute provisions of the present document.

  • References are either specific (identified by date of publication and/or edition number or version number) or non-specific.
  • For a specific reference, subsequent revisions do not apply.
  • For a non-specific reference, the latest version applies.

Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference.

[1] ETSI EN 300 175-1: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI); Part 1: Overview".

[2] ETSI EN 300 175-5: "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI); Part 5: Network (NWK) layer".

[3] ETSI EN 300 176 (all parts): "Digital Enhanced Cordless Telecommunications (DECT); Test specification; (Part 1: Radio; Part 2: Speech)".

ETSI

SIST EN 300 175-8 V1.9.1:2006

8 ETSI EN 300 175-8 V1.9.1 (2005-09)

[4] Void.

[5] Void.

[6] Void.

[7] Void.

[8] ITU-T Recommendation G.701: "Vocabulary of digital transmission and multiplexing, and pulse code modulation (PCM) terms".

[9] ITU-T Recommendation G.726: "40, 32, 24, 16 kbit/s Adaptive Differential Pulse Code Modulation (ADPCM)".

[10] Void.

[11] ITU-T Recommendation P.10: "Vocabulary of terms on telephone transmission quality and telephone sets".

[12] ITU-T Recommendation P.340: "Transmission characteristics and speech quality parameters of hands-free terminals".

[13] Void.

[14] ITU-T Recommendation G.111: "Loudness Ratings (LRs) in an international connection". [15] ETSI ETS 300 540: "Digital cellular telecommunications system (Phase 2) (GSM); Transmission planning aspects of the speech service in the GSM Public Land Mobile Network (PLMN) system (GSM 03.50)".

3 Symbols and abbreviations

3.1 Symbols

For the purposes of the present document, the symbols given in ITU-T Recommendations P.10 [11], G.701 [8], EN 300 175-1 [1] and the following apply:

dBm: absolute power level relative to 1 milliwatt, expressed in dB dBm0: absolute power level in dBm referred to a point of zero relative level (0 dBr point) dBPa: sound pressure level relative to 1 Pa, expressed in dB dBPa(A): a-weighted sound pressure level relative to 1 Pa, expressed in dB dBr: relative power level of a signal in a transmission path referred to the level at a reference point on the path (0 dBr point)

3.2 Abbreviations

For the purposes of the present document, the abbreviations given in ITU-T Recommendations P.10 [11], G.701 [8] and the following apply:

ADPCM Adaptive Differential Pulse Code Modulation BSS Base Station Sub-system CI Common Interface CLRR Circuit Loudness Rating, Receiving CLRS Circuit Loudness Rating, Sending CRFP Cordless Radio Fixed Part DECT Digital Enhanced Cordless Telecommunications DTX Discontinuous Transmission ETSI

SIST EN 300 175-8 V1.9.1:2006

9 ETSI EN 300 175-8 V1.9.1 (2005-09)

ERP Ear Reference Point ES End System EUT Equipment Under Test FP Fixed Part FT Fixed radio Termination GAP Generic Access Profile GSM Global System for Mobile communications IC Integrated Circuit I equipment Impairment factor e ISDN Integrated Services Digital Network LL Local echo Loss e LSTR Listener SideTone Rating MRP Mouth Reference Point MSC Mobile Switching Centre NLP Non-Linear Processor NWK NetWorK PABX Private (Automatic) Branch eXchange PCM Pulse Code Modulated PP Portable Part PSTN Public Switched Telephone Network PT Portable radio Termination REP REpeater Part RePP Reference Portable Part RF Radio Frequency RFP Radio Fixed Part RLR Receiving Loudness Rating RLR Receiving Loudness Rating of the Handset H SLR Sending Loudness Rating SLR Sending Loudness Rating of the Handset H STMR SideTone Masking Rating TA Terminal Adaptors TCLw weighted Terminal Coupling Loss TDMA Time Division Multiple Access TELR Talker's Echo Loudness Rating VAD Voice Activity Detection WBS Wireless Base Station WRS Wireless Relay Station

4 Configurations

4.1 Reference configuration

4.1.1 Basic configuration

The basic reference configuration for voice transmission over DECT is shown in figure 1. ETSI

SIST EN 300 175-8 V1.9.1:2006

10 ETSI EN 300 175-8 V1.9.1 (2005-09)

PP (handset) FP (fixed part) Acoustic Air Line interface interface Line MRP Acoustic interface Transcoder Transcoder 0 interface + + echo Uniform Uniform Volume control PCM PCM control + to/from to/from + Volume control air code air code ] coder + coder ERP Uniform Uniform PCM PCM reference reference point point

Figure 1: Basic reference configuration The PP and the FP are delimited by physical interfaces:

Acoustic: from the PP towards the speaker-listener, with the Ear and Mouth Reference Points (ERP and MRP).

Air(RF): the interface between PP and FP.

Line: the interface from the FP towards the network.

Uniform PCM reference points shall be introduced in both the PP and the FP to materialize the limits of the transmission segment which is affected by the air interface coding scheme. This allows the transmission requirements to be specified independently from the coding at the air interface. The various transcoding algorithms are level-transparent, i.e. with an encoder and decoder connected in tandem, the "levels" of the digital signals at the uniform PCM input of the encoder and output from the decoder are identical. In a particular implementation, the reference points may be embedded within an IC, and thus will not be physically accessible. Each of the three sections thus delimited deals with distinct functions:

a) the PP electro-acoustic section (between acoustic interface and PP uniform PCM reference point) which includes the acoustic interface, the volume control and the analogue to digital conversion; b) the air-code section (between PP and FP uniform PCM reference points) considers the transcoding between uniform PCM and the air-code, as well as the transmission over the air interface; c) the FP line interface section (between FP uniform PCM reference point and line interface) comprises the interface to the line, digital or analogue, and the FP voice processing, e.g. echo control. Typically, the transmission features conform to TBR 008 (see bibliography) for the PP electro-acoustic section, and the line interface section in the case of digital interface. In the case of analogue interface, the line interface section realizes in the FP the adaptation to clause 7.12 and to the relevant attachment requirements. ETSI

SIST EN 300 175-8 V1.9.1:2006

11 ETSI EN 300 175-8 V1.9.1 (2005-09)

4.1.2 Portable Part (PP)
4.1.2.1 Functional organization

Figure 2 represents the basic functional organization of a PP from the voice transmission point of view. Uniform PCM Air Acoustic reference point interface interface SLR H MRP

0 A/D

Transcoder Electro- Uniform PCM acoustic to/from interface air code D/A

ERP filter RLR H

Figure 2: PP functional organization The various functions represented in figure 2 are:

a) the electro-acoustic function, which performs the interface to the transducers and the volume control. The Handset Loudness Ratings (SLR ) and (RLR ) are defined between the acoustic interface and the uniform H H PCM reference point; b) the analogue to digital and digital to analogue coding to the uniform PCM reference point; c) the transcoder between uniform PCM and air-code.

4.1.2.2 Volume control

The volume control facility is optional, and can be implemented in a number of different ways:

1) in the simplest implementation, it affects only the receiving level and is under the manual control of the PP user; 2) the volume adjustment may also be adaptive, e.g. taking into account the average level of ambient noise at the MRP; 3) the volume control may affect both receiving and sending levels in opposite directions. This has the advantage of reducing the influence on the terminal coupling loss when the receive volume is increased. Such an implementation would fit a noisy environment, as the need for an increased receiving volume is likely to come from a loud ambient noise, and it is then combined with a loud speech level. ETSI

SIST EN 300 175-8 V1.9.1:2006

12 ETSI EN 300 175-8 V1.9.1 (2005-09)

4.1.3 Fixed Part (FP)
4.1.3.1 Digital interface

Figure 3 shows the functional organization of a FP with a digital interface. Uniform PCM Air Line interface reference point interface Control Transcoder of echo Transcoder Uniform PCM from Uniform PCM to/from handset to/from air code and A-law network

Figure 3: FP functional organization The various functions represented in figure 3 are:

a) a transcoder between air-code and uniform PCM; b) an echo control function which processes echoes coming back from both the handset and the network. It provides additional losses that compensate for the increased length of the echo path due to the DECT transmission delay over the air interface; c) a transcoder from uniform PCM to A-law PCM towards the line interface.

4.1.3.2 Analogue interface

The implementation of a FP with an analogue interface is shown in figure 4. Air Uniform PCM Line interface reference point interface CLRS D/A Control

filter of echo Transcoder from Uniform PCM network to/from including air code hybrid echo A/D CLRR

Figure 4: FP with an analogue interface The various functions represented in figure 4 are:

a) the line interface comprises the digital to analogue coder-decoder and the adaptation to the line, that can be either 2- or 4-wire. The Circuit Loudness Ratings (CLRR and CLRS) are defined between uniform PCM reference point and the line interface; ETSI

SIST EN 300 175-8 V1.9.1:2006

13 ETSI EN 300 175-8 V1.9.1 (2005-09)

b) in the case of a 2-wire line, the network echo controller deals both with the local hybrid echo and the far end network echo.

4.1.3.3 FP adaptive volume control

An adaptive dual volume adjustment, as described in clause 4.1.2.2, may optionally be implemented into the FP, for base stations where the associated PPs may be used in a noisy environment (e.g. public access).

4.2 Test configurations

A DECT system comprises a FP and a PP. As these parts are not always purchased together, it is a requirement that either the complete system or each of the two separate parts shall be capable of being tested (see EN 300 176 [3]).

5 Encoding

5.1 32 kbit/s full term (ADPCM)

5.1.1 Algorithm

The speech coding algorithm shall conform to ITU-T Recommendation G.726 [9] for 32 kbit/s Adaptive Differential Pulse Code Modulation (ADPCM).

The A-law companding and synchronous tandem adjustment maybe omitted in FPs with an analogue line interface and in PPs.

NOTE: ITU-T Recommendation G.726 [9] 32 kbit/s ADPCM codecs support the use of the voice channel for telefax of group 2 and group 3. For group 3 the data speed, which is automatically negotiated, is in practice normally limited to 9,6 kbit/s.

5.1.2 Bit sequence

The ADPCM words comprised in each burst shall be transmitted in chronological order, and with the most significant bit transmitted first within each word.

5.2 Other codings

No other coding scheme is specified at this time. When introducing a new coding the following speech performance characteristics shall be reviewed:

  • frequency response;
  • distortion;
  • delay; and
  • if the latter is widely affected, terminal coupling loss and network echo control. ETSI

SIST EN 300 175-8 V1.9.1:2006

14 ETSI EN 300 175-8 V1.9.1 (2005-09)

6 Transmission aspects

6.1 Relative level

The digital line interface is a 0 dBr point according to ITU-T Recommendation G.101 (see bibliography). As the various digital transcoding algorithms are essentially loss-less, the relative level is constant over the whole digital path in the PP and the FP.

6.2 Acoustic reference level

The acoustic reference level is defined as the acoustic level which corresponds to a level of -10 dBm0 at the digital interface.

6.3 Volume control

Unless stated otherwise, if a user-controlled volume control is provided at the PP, the requirements apply for all positions of the volume control, and the compliance tests shall be carried out at the maximum setting of this volume control.

NOTE: The testing of a PP with a dual or an adaptive volume control requires further study.

7 Speech performance characteristics

7.1 PP frequency responses

7.1.1 Sending

The sending sensitivity-frequency response (from MRP to the digital interface) shall be within a mask as defined in table 1.

Table 1: Sending sensitivity-frequency mask Frequency (Hz) Upper limit (dB) Lower limit (dB) 100 -9 200 0 300 0 -14 800 0 -10 2 000 4 -8 3 400 4 -11 4 000 4 8 000 -13 NOTE 1: The limits at intermediate frequencies lie on a straight line drawn between the given values on a log (frequency) - linear (dB) scale. NOTE 2: All dB levels are on an arbitrary scale.

ETSI

SIST EN 300 175-8 V1.9.1:2006

15 ETSI EN 300 175-8 V1.9.1 (2005-09)

7.1.2 Receiving

The receiving sensitivity-frequency response (from the digital interface to the ERP) shall be within a mask as defined in table 2.

Table 2: Receiving sensitivity-frequency mask Frequency (Hz) Upper limit (dB) Lower limit (dB) 100 -10 200 2 300 2 -9 1 000 2 -7 3 400 2 -12 4 000 2 8 000 -15 NOTE 1: The limits at intermediate frequencies lie on a straight line drawn between the given values on a log (frequency) - linear (dB) scale. NOTE 2: All dB levels are on an arbitrary scale.

7.2 PP sending and receiving loudness ratings

7.2.1 Nominal values

The nominal values are:

  • Sending Loudness Rating (SLR ) = 8 dB; and H
  • Receiving Loudness Rating (RLR ) = 2 dB.

H There is a manufacturing tolerance of ±3,5 dB on both RLR and SLR . H H NOTE: ITU-T test methods on loudness ratings are valid only for codecs that can transmit sinusoids without excessive distortion.

7.2.2 User-controlled volume control in PP

A user-controlled volume control shall be provided in all PP equipment, except where an adaptive volume control is incorporated in the PP.

When adjusting the volume control from nominal setting (where RLR is closest to its nominal value) to maximum H setting, the decrease in RLR shall be not less than 6 dB.

H A user-controlled volume control can be implemented either as a receiving volume control (where RLR is changed) or H as a "joint-acting" volume control (where SLR and RLR are simultaneously changed in opposite directions). For both H H types of volume control RLR and SLR shall simultaneously meet the values given in clause 7.2.1 (including the H H tolerances) for at least one setting of the volume control.

The RLR and SLR shall not exceed the limits given in tables 3 and 4. H H Table 3: Absolute limits for "joint-acting" volume control Volume setting Maximum Minimum RLR -13 dB 19 dB H SLR 17 dB 3 dB H

ETSI

SIST EN 300 175-8 V1.9.1:2006

16 ETSI EN 300 175-8 V1.9.1 (2005-09)

Table 4: Absolute limits for a receiving volume control Volume setting Maximum Minimum RLR -13 dB 19 dB H

NOTE 1: Minimum setting: The setting where the RLR has its maximum value. Maximum setting: The setting where the RLR has its minimum value. NOTE 2: A user-controlled volume control should include an automatic reset function that ensures that the default setting for each new call is no louder than the nominal setting. NOTE 3: The basic DECT requirements (echo control, signal levels for A/D converters, etc.) are optimized for digital (ISDN) transmission characteristics. Analogue networks (see TBR 038 - see bibliography) require higher receive levels (lower RLR) than digital networks (ISDN). This is to compensate for old long lossy analogue lines that still exist in many PSTNs. Most of the calls do not have lossy lines. Analogue transmissions over a modern network (from equipment using TBR 038 values of SLR and RLR) will thus often provide higher receive levels than a digital (ISDN) connection would. This gives an interworking problem between analogue networks and terminals that use digital codecs as in DECT systems and ISDN terminals, which could cause distortion in the A/D converters and also lower the margin for the wanted terminal echo loss. Therefore, noting that DECT PPs have a volume control with at least 6 dB gain to compensate for lossy connections, it should be allowed to design DECT FP equipment with a receive gain providing typical 4 dB to 6 dB higher nominal RLR (for FP + PP) than specified in relevant attachment requirements to the PSTN (see TBR 038). See clause 7.12.2.2. Some administrations have already implemented this principle.

7.2.3 PP adaptive volume control

The PP shall inform the FP if an adaptive volume control is implemented in the PP. Clause 7.7.41 in EN 300 175-5 [2] describes how this shall be done.

This function is for further study and may follow GSM, or other, specifications when available.

7.2.4 FP adaptive volume control

An adaptive volume control, depending on the level of environmental noise at the PP, may be implemented into the FP. The gain variation shall be symmetrical, i.e. the increase in the receiving direction shall be equal to the decrease in the sending direction.

If the PP adaptive volume control feature is implemented then the FP adaptive volume control feature shall be disabled. NOTE 1: The PP ambient noise level is calculated in the FP based upon the minimum ambient noise rejection requirement as specified in clause 7.11.

...