Abstract

This document classifies polymer-based crown and veneering materials used in dentistry and specifies their requirements. It also specifies the test methods to be used to determine conformity to these requirements.
This document is applicable to polymer-based crown and veneering materials for laboratory fabricated permanent veneers or crowns. It also applies to polymer-based dental crown and veneering materials for which the manufacturer claims adhesion to the substructure without macro-mechanical retention such as beads or wires.

Status
Published
Public Enquiry End Date
30-May-2025
Publication Date
29-Sep-2026
Technical Committee
VAZ - Healthcare
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
24-Sep-2026
Due Date
29-Nov-2026
Completion Date
30-Sep-2026

Buy Documents

Standard

SIST EN ISO 10477:2026

English language (34 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN ISO 10477:2026 is the Slovenian adoption of EN ISO 10477:2026 and is identical to ISO 10477:2026. It classifies polymer-based crown and veneering materials used in dentistry, specifies their requirements, and gives the test methods used to check conformity. It is intended for laboratory fabricated permanent veneers or crowns, including materials for which the manufacturer claims adhesion to the substructure without macro-mechanical retention such as beads or wires.

What does SIST EN ISO 10477:2026 specify?

SIST EN ISO 10477:2026 sets out the scope, vocabulary, classification, requirements, sampling, test methods, and packaging and labelling rules for polymer-based crown and veneering materials. In practice, that means it tells manufacturers and test laboratories what material families are covered, which properties must be checked, and how those checks are carried out.

The document applies to polymer-based crown and veneering materials for permanent veneers or crowns made in a laboratory. It also applies when the manufacturer claims adhesion to a substructure without macro-mechanical retention, which matters for products that bond chemically or by special surface treatment rather than by beads or wires.

The structure is straightforward:

  • Clauses 1-4 define the scope, references, terms, and classification.
  • Clause 5 states the performance requirements.
  • Clause 6 covers sampling.
  • Clause 7 gives the measurement and test methods.
  • Clause 8 covers packaging, labelling, and instructions for use.
  • Table 1 links the material type or class to the tests that apply, and Table 5 lists the information the manufacturer must provide.

What are the key requirements of SIST EN ISO 10477:2026?

The standard is built around classification first, then testing. Which tests apply depends on the material type and class, so users need to identify the product correctly before trying to show conformity.

Classification drives the test plan

Clause 4 classifies materials by how they set or are manufactured:

  • Type 1 - self-curing
  • Type 2 - externally energy activated
  • Class 1 - no photopolymerization initiator
  • Class 2 - has a photopolymerization initiator and is not for additive manufacturing
  • Class 3 - intended for additive manufacturing
  • Type 3 - dual-cure
  • Type 4 - intended for subtractive manufacturing

This matters because Table 1 uses the classification to decide which requirements apply. For example, depth of cure is only checked for type 2 class 2 materials, while type 2 class 3 and type 4 materials are treated differently for flexural strength.

Mechanical performance must match the material type

Clause 5.4 sets the flexural strength requirement. Type 1, type 2 classes 1 and 2, and type 3 materials must reach at least 50 MPa. Type 2 class 3 and type 4 materials must reach at least 80 MPa. For a buyer or lab, this is the main indicator of whether the material is suitable for the intended restoration workflow.

Clause 5.2 also requires depth of cure checks for type 2 class 2 materials. The hardness of the bottom surface has to be at least 70% of the top surface. That helps confirm that light or heat can cure the material through its thickness.

Bonding is controlled when a special bonding system is used

Clause 5.5 applies to materials used with a special bonding system without macro-mechanical retention. If the manufacturer recommends such a system, the bond strength to the substructure material must be at least 5 MPa. If the manufacturer claims a value above 5 MPa, the tested bond strength must reach at least 80% of the claimed value, with a floor of 5 MPa.

This is especially relevant for products intended to adhere to frameworks without beads or wires, because the bond itself becomes part of the safety and performance claim.

Surface quality, water uptake, and solubility are checked as material behaviour

Clause 5.3 requires a polished specimen to have a glossy surface, which is a practical way of checking finishability. Clauses 5.6 and 5.7 limit water sorption and solubility for cured material. Those checks matter because water uptake and leaching can affect appearance, fit, and long-term stability.

Opaque resins are treated differently in several clauses: the depth of cure, surface finish, water sorption, and solubility requirements are not applied to them, while bond strength remains relevant.

Colour consistency is part of conformity

Clauses 5.8 and 5.9 require shade consistency between batches and colour stability after ageing. The comparison is made in accordance with ISO 7491, using specimens from different batches and specimens exposed to water and xenon irradiation.

For a laboratory or purchaser, this is important because colour mismatch is a common reason for remakes even when the mechanical properties are acceptable.

Sampling and test conditions are controlled

Clause 6 sets the sampling rules. The test sample must come from one selected shade from a single batch, with additional samples from another batch for shade consistency and further shades for colour stability. Clause 7 fixes the test environment at room conditions and specifies the water grades to use.

That means results are meant to be repeatable across laboratories, not dependent on local handling habits.

Packaging and instructions for use are part of conformity

Clause 8 requires packaging that protects the material until the marked expiry date. It also requires clear marking and instructions for use, including the material type and class, shade, storage conditions, lot number, polymerization procedure, application range, finishing and polishing method, limitations, side effects, and the date of issue of the instructions.

For users, this is not just administrative: the wrong curing source, milling device, or finishing method can directly affect test results and clinical performance.

What terms does SIST EN ISO 10477:2026 define?

  • Polymer-based crown and veneering material - a dental material supplied as powders and liquids, pastes, or pre-polymerized blocks or discs, intended for permanent crowns or veneers after polymerization or processing.
  • Dentine resin - a slightly translucent, pigmented material used to simulate natural dentine.
  • Enamel resin - a translucent, lightly pigmented material used to simulate enamel, including the incisal portion.
  • Cervical resin - a more strongly pigmented, slightly translucent material used to simulate cervical tooth areas.
  • Opaque resin - a material that masks the underlying colour when bonded to a substructure.
  • Additive manufacturing (AM) - a layer-by-layer process of joining materials from 3D model data; the standard also uses the term printing.
  • Subtractive manufacturing - milling or machining a larger bulk object down to a smaller 3D object.
  • Vat photopolymerization (VPP) - an additive manufacturing process in which liquid photopolymer in a vat is selectively cured.

Who uses SIST EN ISO 10477:2026?

SIST EN ISO 10477:2026 is used by manufacturers of dental crown and veneering materials, dental laboratories, and test laboratories that verify mechanical, optical, and bonding performance. It is also relevant to quality managers and buyers who need to compare products by type, class, and claimed performance.

The standard is particularly relevant where products are processed by conventional laboratory methods, additive manufacturing, or subtractive manufacturing. It is also used where a manufacturer claims adhesion to a substructure without macro-mechanical retention.

What changed in SIST EN ISO 10477:2026 from the previous edition?

This fifth edition cancels and replaces ISO 10477:2020, and EN ISO 10477:2026 supersedes EN ISO 10477:2020. The stated technical changes are:

  • materials for additive manufacturing were added to Clause 4 as type 2 class 3;
  • materials for subtractive manufacturing were added to Clause 4 as type 4;
  • editorial updates were made.

Which standards are used with SIST EN ISO 10477:2026?

StandardWhat it contributes
ISO 1942Core dental vocabulary used in the terms and definitions
ISO 18739Vocabulary for the CAD/CAM process chain
ISO 3696:1987Water quality for laboratory and test use
ISO 5139Related guidance for polymer-based composite machinable blanks
ISO 6344-2Abrasive grain size designation for test specimen preparation
ISO 6344-3Fine abrasive grain size designation for polishing
ISO 6507-1Vickers hardness test used for depth of cure
ISO 7491Colour stability method used for shade and colour checks
ISO 7500-1Calibration of the force-measuring system on test machines
ISO 8601-1Year-month date format for expiry dates
ISO 22674Reference for suitable alloy or metal framework materials
ISO 10993-1Biological safety evaluation route mentioned in the introduction
ISO 7405Dentistry biocompatibility evaluation route mentioned in the introduction

What does the SIST EN ISO 10477:2026 document contain?

The document contains a classification table, a test protocol table, physical and chemical requirement limits, specimen preparation procedures, and detailed apparatus descriptions for hardness, flexural, bond strength, water sorption, solubility, and colour testing. It also includes formulas for calculating flexural strength, bond strength, water sorption, and solubility, plus result-handling rules for first and repeat tests.

Figures show the specimen moulds and the bond-strength test setup. Table 5 gives the manufacturer information that must appear on the outer pack, containers, machinable blanks, and instructions for use.

Relations

Effective Date
01-Nov-2026
Effective Date
28-Oct-2026
Effective Date
17-Sep-2026

Buy Documents

Standard

SIST EN ISO 10477:2026

English language (34 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

BSI Group

BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

UKAS United Kingdom Verified

TÜV Rheinland

TÜV Rheinland is a leading international provider of technical services.

DAKKS Germany Verified

TÜV SÜD

TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.

DAKKS Germany Verified

Sponsored listings

Frequently Asked Questions

SIST EN ISO 10477:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Dentistry - Polymer-based crown and veneering materials (ISO 10477:2026)". This standard covers: This document classifies polymer-based crown and veneering materials used in dentistry and specifies their requirements. It also specifies the test methods to be used to determine conformity to these requirements. This document is applicable to polymer-based crown and veneering materials for laboratory fabricated permanent veneers or crowns. It also applies to polymer-based dental crown and veneering materials for which the manufacturer claims adhesion to the substructure without macro-mechanical retention such as beads or wires.

This document classifies polymer-based crown and veneering materials used in dentistry and specifies their requirements. It also specifies the test methods to be used to determine conformity to these requirements. This document is applicable to polymer-based crown and veneering materials for laboratory fabricated permanent veneers or crowns. It also applies to polymer-based dental crown and veneering materials for which the manufacturer claims adhesion to the substructure without macro-mechanical retention such as beads or wires.

SIST EN ISO 10477:2026 is classified under the following ICS (International Classification for Standards) categories: 11.060.10 - Dental materials. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN ISO 10477:2026 has the following relationships with other standards: It is inter standard links to SIST EN ISO 10477:2020, SIST ISO 3696:1995, SIST EN 1641:2010. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN ISO 10477:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 polymer-based crown and veneering material
  • 3.2 dentine resin
  • 3.3 enamel resin
  • 3.4 cervical resin
  • 3.5 opaque resin
  • 3.6 subtractive manufacturing
  • 3.7 additive manufacturing
  • 3.8 vat photopolymerization
  • 3.9 vat
  • 3.10 computer-aided milling machine
  • 4 Classification
  • 5 Requirements
  • 5.1 General
  • 5.2 Depth of cure — — + — — —
  • 5.2 Depth of cure
  • 5.3 Surface finish
  • 5.4 Flexural strength
  • 5.2 Depth of cure
  • 5.4 Flexural strength
  • 5.5.2 ≥5 MPa
  • 5.6 Water sorption ≤40 µg/mm
  • 5.7 Solubility ≤7,5 µg/mm
  • 5.5 Bond strength
  • 5.6 Water sorption
  • 5.7 Solubility
  • 5.8 Shade consistency
  • 5.9 Colour stability
  • 6 Sampling
  • 6.1 For all tests
  • 6.2 For test of shade consistency
  • 6.3 For test of colour stability
  • 7 Measurement and test methods
  • 7.1 General
  • 7.2 Visual inspection
  • 7.3 Depth of cure (only for type 2, class 2 if not opaque resin)
  • 7.4 Surface finish
  • 7.5 Flexural strength
  • 3 Repeat test
  • 5 Yes
  • 7.6 Bond strength (only type 1, type 2 classes 1 and 2 and type 3 materials)
  • 7.7 Water sorption and solubility
  • 3 Repeat test
  • 7.8 Shade consistency and colour stability
  • 8 Packaging and labelling
  • 8.1 Packaging
  • 8.2 Labelling and instructions for use
  • 7 M M
  • 8 Lot number (batch code) M M M
  • 10 Range of application M
  • Bibliography

Introduction

Specific qualitative and quantitative test methods for demonstrating freedom from unacceptable biological hazards are not included in this document, but, for the assessment of possible biological hazards, reference [1] [2] should be made to ISO 10993-1 and ISO 7405 .

SIST EN ISO 10477:2026 International Standard ISO 10477:2026(en) Dentistry — Polymer-based crown and veneering materials

1 Scope

This document classifies polymer-based crown and veneering materials used in dentistry and specifies their requirements. It also specifies the test methods to be used to determine conformity to these requirements. This document is applicable to polymer-based crown and veneering materials for laboratory fabricated permanent veneers or crowns. It also applies to polymer-based dental crown and veneering materials for which the manufacturer claims adhesion to the substructure without macro-mechanical retention such as beads or wires.

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 1942, Dentistry — Vocabulary ISO 3696:1987, Water for analytical laboratory use — Specification and test methods ISO 5139, Dentistry — Polymer-based composite machinable blanks ISO 6344-2, Coated abrasives — Determination and designation of grain size distribution — Part 2: Macrogrit sizes P12 to P220 ISO 6344-3, Coated abrasives — Determination and designation of grain size distribution — Part 3: Microgrit sizes P240 to P5000 ISO 6507-1, Metallic materials — Vickers hardness test — Part 1: Test method ISO 7491, Dental materials — Determination of colour stability ISO 7500-1, Metallic materials — Calibration and verification of static uniaxial testing machines — Part 1:

Tension/compression testing machines — Calibration and verification of the force-measuring system ISO 8601-1, Date and time — Representations for information interchange — Part 1: Basic rules ISO 18739, Dentistry — Vocabulary of process chain for CAD/CAM systems ISO 22674, Dentistry — Metallic materials for fixed and removable restorations and appliances

3 Terms and definitions

For the purposes of this document, the terms and definitions given in ISO 1942, ISO 18739 as well as the following apply.

ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • IEC Electropedia: available at http:// www .electropedia .org/
  • ISO Online browsing platform: available at http:// www .iso .org/ obp

SIST EN ISO 10477:2026 ISO 10477:2026(en)

3.1 polymer-based crown and veneering material

dental material supplied as a composite of powders and liquids or pastes that can contain monomers, either inorganic fillers or polymeric fillers, or both, or pre-polymerized blocks or discs that can contain polymers and inorganic fillers, and that, when polymerized or processed, is suitable for use as permanent dental veneers or crowns Note 1 to entry: Polymerization is effected either by mixing initiator(s) and activator(s) (“self-curing” materials) or by external energy activation [by heat (“heat-curing” materials), photoactivated materials, either by visible light radiation (“light-curing” materials) or by UV radiation ("UV-curing" materials), or both], or both (“dual-cure” materials). Note 2 to entry: The polymer-based crown and veneering materials for laboratory-fabricated permanent veneers or crowns can be used without substructure or can be attached to a substructure.

3.2 dentine resin

pigmented and slightly translucent polymer-based crown and veneering material (3.1) used to simulate the natural appearance of the dentine in a resin-based restoration or dental prosthesis

3.3 enamel resin

translucent, lightly pigmented polymer-based crown and veneering material (3.1) used to simulate the natural appearance of enamel, including the incisal portion of a resin-based restoration or dental prosthesis

3.4 cervical resin

intensely pigmented slightly translucent polymer-based crown and veneering material (3.1) having colours simulating those of cervical parts of natural teeth

3.5 opaque resin

polymer-based crown and veneering material (3.1) which, when applied to a substructure in accordance with the manufacturer's instructions, bonds to the surface and forms a layer that masks the underlying colour Note 1 to entry: Opaque resins are only required to fulfil the requirement of 5.5.

3.6 subtractive manufacturing

milling process of machining, grinding or reducing a larger bulk object to create a smaller detailed three-dimensional object using computer-aided design software and computer-aided manufacturing methods Note 1 to entry: The term milling (3.6) is used in this document as it is a common term in dental technology and clinical dentistry for the processing of these materials.

3.7 additive manufacturing

AM printing process of joining materials to make parts from 3D model data, usually layer upon layer, as opposed to subtractive manufacturing (3.6) and formative manufacturing methodologies Note 1 to entry: The term printing (3.7) is used in this document as it is a common term in dental technology and clinical dentistry for the processing of these materials.

SIST EN ISO 10477:2026 ISO 10477:2026(en)

3.8 vat photopolymerization

VPP additive manufacturing (3.7) process in which liquid photopolymer in a vat (3.9) is selectively cured by photo-activated polymerization Note 1 to entry: The liquid photopolymer can consist of monomers and photo-polymerization initiators and contain fillers.

Note 2 to entry: The term printing (3.7) can be used instead of the term vat photopolymerization (3.8) in dental technology and clinical dentistry for the processing of these materials.

3.9 vat

small tub, part of the polymerization device that contains the liquid photopolymer

3.10 computer-aided milling machine

computer-aided machining device designed for subtractive manufacturing (3.6) of dental restorations and dental prostheses using rotary instruments for cutting and grinding

4 Classification

The polymer-based crown and veneering materials described in this document shall be classified according to their activation system for polymerization:

  • Type 1: polymer-based crown and veneering materials whose setting is effected by mixing initiator(s) and activator(s) (“self-curing” materials);
  • Type 2: polymer-based crown and veneering materials whose setting is effected by the application of energy from an external source (“external-energy-activated” materials), e.g. heat or radiation (visible or UV range) or both;
  • Class 1: polymer-based crown and veneering materials that do not contain a photo-polymerization initiator;
  • Class 2: polymer-based crown and veneering materials that contain a photopolymerization initiator and are not intended for additive manufacturing (printing);
  • Class 3: polymer-based crown and veneering materials that are intended for additive manufacturing, e.g. vat photopolymerization (printing);
  • Type 3: polymer-based crown and veneering materials whose setting is affected by mixing initiator(s) and activator(s) and also by the application of energy from an external source (“dual-cure” materials);
  • Type 4: polymer-based crown and veneering materials that are intended for subtractive manufacturing (e.g. milling).

5 Requirements

5.1 General

The tests required for a crown and veneering material depend on the classification according to type and class.

See Table 1 for the necessity of the specific tests described in 5.2 to 5.9.

SIST EN ISO 10477:2026 ISO 10477:2026(en) Table 1 — Test protocol Type 2 Subclause Property Type 1 Type 3 Type 4 Class 1 Class 2 Class 3 a b

5.2 Depth of cure — — + — — —

Surface a a a a 5.3 + + + + + + finish Flexural a a a a 5.4 + + + + + + strength Bond strength to c c 5.5 + + + — + — the framework Water sorption, sol- a a a a 5.6 to 5.9 ubility, shade + + + + + + consistency, colour Key + carry out test - do not test a If the material is opaque resin, do not test.

b Not required because the curing process is inherently defined in the vat photopolymerization device and process (see 5.2.2).

Not required as these materials are not intended for veneering of frameworks.

5.2 Depth of cure

5.2.1 General

Testing shall be carried out in accordance with 7.3.

5.2.2 Depth of cure (only type 2 class 2 materials)

For type 2 class 2 materials, the hardness of the bottom surface shall be not less than 70 % of that of the top surface (see Table 2). This requirement is not applicable to opaque resins. For type 1, type 2 class 1, and type 3 and type 4 materials, no requirement is specified. For type 2 class 3 materials, no requirement is specified as the curing process is inherently defined in the additive manufacturing process.

5.3 Surface finish

A test specimen polished in accordance with 7.4 shall have a glossy surface. Testing shall be carried out in accordance with 7.4. This requirement is not applicable to opaque resins.

5.4 Flexural strength

Flexural strength shall be at least 50 MPa for:

  • type 1;
  • type 2 classes 1 and 2;
  • type 3.

SIST EN ISO 10477:2026 ISO 10477:2026(en) Flexural strength shall be at least 80 MPa for type 2 class 3 and type 4 materials (see Table 2). This requirement is not applicable to opaque resins.

Testing shall be carried out in accordance with 7.5.

Table 2 — Physical and chemical requirements Subclause Property Requirement Hardness of bottom surface ≥70 %

5.2 Depth of cure

of top surface ≥50 MPa for type 1, type 2 classes 1 and 2 and type 3

5.4 Flexural strength

≥ 80 MPa for type 2 class 3 and type 4 5.5.1 ≥5 MPa Bond strength ≥80 % of the value claimed but

5.5.2 ≥5 MPa

5.6 Water sorption ≤40 µg/mm

5.7 Solubility ≤7,5 µg/mm

5.5 Bond strength

5.5.1 Special bonding system without macromechanical retention

If the manufacturer recommends a special bonding system without macromechanical retention, the strength of bond to the material used for the substructure shall be not less than 5 MPa (see Table 1 and Table 2). Testing shall be carried out in accordance with 7.6.

5.5.2 Values higher than 5 MPa

If the manufacturer claims a value higher than 5 MPa for the bond strength, then the bond strength shall be not less than 80 % of the value claimed with a minimum of 5 MPa. Testing shall be carried out in accordance with 7.6.

5.6 Water sorption

The water sorption of the cured polymer-based crown and veneering material shall be not more than 40 µg/

mm (see Table 2).

Testing shall be carried out in accordance with 7.7. This requirement is not applicable to opaque resins.

5.7 Solubility

The solubility in water of the cured polymer-based crown and veneering material shall be not more than 7,5

µg/mm (see Table 2).

Testing shall be carried out in accordance with 7.7. This requirement is not applicable to opaque resins.

5.8 Shade consistency

The colours of the cured polymer-based crown and veneering material from different batches (according to 6.1 and 6.2) shall show no more than a slight difference with the colour indicated by the manufacturer. Testing shall be carried out in accordance with 7.8 and ISO 7491.

SIST EN ISO 10477:2026 ISO 10477:2026(en)

5.9 Colour stability

The polymer-based crown and veneering material shall show no more than a slight change in colour. Testing shall be carried out in accordance with 7.8 and ISO 7491.

6 Sampling

6.1 For all tests

The test sample shall consist of one or more packages of one selected shade, corresponding to the purpose of the test, from a single batch and contain sufficient material to carry out the specified tests, plus an allowance for any necessary repetition of tests.

For type 1, type 2 classes 1 and 2 and type 3 materials, an amount of 20 ml of material is recommended.

6.2 For test of shade consistency

The sample for the test of shade consistency (5.8 and 7.8) shall consist of the same shade as in 6.1 but from another batch.

For type 1, type 2 classes 1 and 2, and type 3 materials, an amount of 1 ml of material is recommended.

6.3 For test of colour stability

The sample for the test of colour stability (5.9 and 7.8) shall consist of two further shades of the material. The shade of the resin sample shall consist of three different shades each of which correspond to one representative shade of enamel resin, dentine resin and cervical resin. They should be selected in consideration of its colouring components, if different colouring components are used. For type 1, type 2 classes 1 and 2 and type 3 materials, an amount of 1 ml of material is recommended.

7 Measurement and test methods

7.1 General

7.1.1 Ambient test conditions

Tests shall be carried out at room conditions (23 ± 2) °C and (50 ± 20) % relative humidity.

7.1.2 Water

Unless otherwise specified, the water to be used shall conform to ISO 3696:1987, Grade 3.

7.1.3 Preparation of test specimens

For the preparation of type 2 and type 3 polymer-based crown and veneering materials, reference shall be made to the instruction for use that state the external energy source or sources recommended for the materials to be tested. Care shall be taken to ensure that the energy source is fully functional. Mix or otherwise prepare the polymer-based crown and veneering material in accordance with the instruction for use and the test conditions specified in 7.1.1. Use only the quantity required to prepare one of the corresponding specimens. If fully cured specimens are required for testing (7.4 to 7.8), the specimens shall behomogeneous. There shall be no voids, clefts or air inclusions present by visual inspection without magnification.

SIST EN ISO 10477:2026 ISO 10477:2026(en) A separating medium which does not interfere with the setting reaction (e.g. 3 % solution of polyvinylstearyl ether wax in hexane) can be used to facilitate removal of the specimen. For the preparation of type 2 class 3 polymer-based crown and veneering materials, reference shall be made to the instructions for use that state the vat photopolymerization device and process specification. For the preparation of type 4 polymer-based crown and veneering materials, reference shall be made to the instructions for use that state the computer-aided milling machine and process specification. It shall be taking care to avoid excess heat generation.

7.2 Visual inspection

Use visual inspection to determine conformity to Clause 8. The colour comparison in 7.8 shall be performed in accordance with ISO 7491.

7.3 Depth of cure (only for type 2, class 2 if not opaque resin)

7.3.1 Apparatus

7.3.1.1 Split rings, such as shown in Figure 1, (15 ± 1) mm in diameter and (1,0 ± 0,1) mm in height.

SIST EN ISO 10477:2026 ISO 10477:2026(en) Dimensions in millimetres Key 1 glass or metal plates 2 split ring 3 retaining plate or former Figure 1 — Mould for the preparation of test specimens for depth of cure, surface finish, water sorption, solubility, shade consistency and colour stability 7.3.1.2 Two plates, e.g. polished metal or glass, measuring approximately 20 mm × 20 mm × 5 mm. 7.3.1.3 Radiation source, as recommended in the instructions for use. 7.3.1.4 Hardness testing instrument, for HV 0,5.

7.3.1.5 Oven, set at (37 ± 1) °C.

7.3.2 Materials

7.3.2.1 White filter paper.

7.3.2.2 Film, colourless, transparent, (50 ± 30) μm thick.

SIST EN ISO 10477:2026 ISO 10477:2026(en)

7.3.3 Procedure and specimen preparation

Cover one plate with a piece of white filter paper followed by the film and position the split ring upon it. Prepare the polymer-based crown and veneering material according to the instruction for use and place it into the split ring to a slight excess. Cover the polymer-based crown and veneering material and the split ring with a second piece of film and the second plate and extrude the excess material. Remove the upper plate and irradiate the test specimen in the split ring through the film in accordance with the instruction for use. Remove the test specimen from the split ring.

Prepare three specimens and store them in water at (37 ± 1) °C for (24 ± 2) h. Carry out the hardness test on the upper and lower surfaces of the specimens three times in accordance with ISO 6507-1.

7.3.4 Expression of results

Express the hardness of each surface as the mean of the three values obtained for it. All three specimens shall meet the requirement of 5.2. Otherwise the polymer-based crown and veneering material does not conform with the requirement of 5.2.

7.4 Surface finish

7.4.1 Apparatus (for type 2 class 3 and type 4 materials)

7.4.1.1 Vat photopolymerization device (for type 2 class 3), as recommended in the instructions for use.

7.4.1.2 Cleaning device (for type 2 class 3), for removing unreacted monomer as recommended in the

instructions for use.

7.4.1.3 Post curing device (for type 2 class 3), as recommended in the instructions for use. 7.4.1.4 Computer-aided milling machine (for type 4), as recommended in the instructions for use.

7.4.2 Materials

7.4.2.1 Abrasive paper, at P220 (in accordance with ISO 6344-2) or P320 (in accordance with ISO 6344-3). 7.4.2.2 Abrasive paper, at least P1000 or finer (in accordance with ISO 6344-3). 7.4.2.3 Polishing compound, precipitated calcium carbonate (CaCO ).

7.4.2.4 Muslin wheel, unstitched, 18-to 36-ply, having a diameter of 70 mm to 95 mm.

7.4.3 Specimen preparation

For type 1, type 2 classes 1 and 2 and type 3 materials, prepare a specimen according to 7.3.3. Polish the test specimen prepared in accordance with the instruction for use. If no specific procedure is given, polish in accordance with the instructions provided under 7.4.3.

...