Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation

Explosionsgefährdete Bereiche - Teil 19: Gerätereparatur, Überholung und Regenerierung

Atmosphères explosives - Partie 19: Réparation, révision et remise en état de l’appareil

Eksplozivne atmosfere - 19. del: Popravilo, obnova in remont opreme

General Information

Status
Not Published
Public Enquiry End Date
11-Jun-2024
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
09-Apr-2024
Due Date
27-Aug-2024

Relations

Buy Standard

Draft
prEN IEC 60079-19:2024
English language
86 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
oSIST prEN IEC 60079-19:2024
01-junij-2024
Eksplozivne atmosfere - 19. del: Popravilo, obnova in remont opreme
Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation
Explosionsgefährdete Bereiche - Teil 19: Gerätereparatur, Überholung und
Regenerierung
Atmosphères explosives - Partie 19: Réparation, révision et remise en état de l’appareil
Ta slovenski standard je istoveten z: prEN IEC 60079-19:2024
ICS:
29.260.20 Električni aparati za Electrical apparatus for
eksplozivna ozračja explosive atmospheres
oSIST prEN IEC 60079-19:2024 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN IEC 60079-19:2024

---------------------- Page: 2 ----------------------
oSIST prEN IEC 60079-19:2024
31J/363/CDV

COMMITTEE DRAFT FOR VOTE (CDV)
PROJECT NUMBER:
IEC 60079-19 ED5
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2024-03-22 2024-06-14
SUPERSEDES DOCUMENTS:
31J/344/CD, 31J/360/CC

IEC SC 31J : CLASSIFICATION OF HAZARDOUS AREAS AND INSTALLATION REQUIREMENTS
SECRETARIAT: SECRETARY:
Croatia Mr Marino Kelava
OF INTEREST TO THE FOLLOWING COMMITTEES: PROPOSED HORIZONTAL STANDARD:

TC 18
Other TC/SCs are requested to indicate their interest, if any, in
this CDV to the secretary.
FUNCTIONS CONCERNED:
EMC ENVIRONMENT QUALITY ASSURANCE SAFETY
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft for
Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.

This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of which they
are aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In Some Countries” clau ses
to be included should this proposal proceed. Recipients are reminded that the CDV stage is the final stage for submitting ISC
clauses. (SEE AC/22/2007 OR NEW GUIDANCE DOC).

TITLE:
Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation

PROPOSED STABILITY DATE: 2025

NOTE FROM TC/SC OFFICERS:

1
Copyright © 2024 International Electrotechnical Commission, IEC. All rights reserved. It is permitted to download this
electronic file, to make a copy and to print out the content for the sole purpose of preparing National Committee positions. You
may not copy or "mirror" the file or printed version of the document, or any part of it, for any other purpose without permis sion
in writing from IEC.

---------------------- Page: 3 ----------------------
oSIST prEN IEC 60079-19:2024
IEC CDV 60079-19 ED5 © IEC 2024 – 2 – 31J/363/CDV

2 CONTENTS
3
4 FOREWORD . 7
5 INTRODUCTION . 17
6 1 Scope . 18
7 2 Normative references . 18
8 3 Terms and definitions . 20
9 4 General . 25
10 4.1 General principles . 25
11 4.1.1 Related drawings . 26
12 4.2 Status of equipment after overhaul or repair . 27
13 4.2.1 General . 27
14 4.2.2 Repair using Schedule Drawings or related drawings . 27
15 4.2.3 Repair using relevant standards . 27
16 4.2.4 Repairs with expert evaluation . 27
17 4.2.5 Legacy Group II and III equipment repairs with user evaluation . 28
18 4.2.6 Repairs of equipment not in compliance with the relevant standards . 28
19 4.3 Instructions for the user .
...

Questions, Comments and Discussion